Industrial edge computers, network switches, and rack-mounted power equipment need an enclosure that supports installation as well as day-to-day operation. The TPS 24U rack cabinet, article RA1127, manufacturer code BJ9900098, combines a free-standing steel structure with lockable access and configurable equipment supports.
For system integrators, panel builders, electrical engineers, and procurement teams, the buying decision is the complete configuration: mounting arrangement, electrical options, cable space, service access, and delivery conditions. Confirm those details before placing an order.
Explore TPS industrial cabinet options and request configuration confirmation →
A typical planning scenario combines an industrial computer for local processing, network equipment for machine connectivity, and rack-mounted instruments for supporting functions. Keeping these devices in one defined enclosure can simplify the equipment plan, physical access arrangements, and handover documentation. The 24U format gives the project a common mechanical reference while leaving the actual installation to be developed around the selected devices. Start with an equipment list, convert it into a populated rack drawing, and then select the cabinet build against that drawing. This approach helps procurement request comparable quotations and helps the installer identify the intended configuration before assembly begins.
1. What the TPS 24U industrial rack cabinet offers
This industrial rack cabinet is intended for 19-inch equipment integration where a substantial steel enclosure and controlled access are useful. Published construction features include RAL 7035 powder-coated sheet steel, square-pipe-reinforced doors, and front/rear locking rods. The described hinges allow a 150° opening; stoppers can establish a defined opening position.
A lockable rack cabinet helps manage physical access to installed equipment, but it does not replace an operating procedure or electrical isolation. Plan how technicians reach connectors, remove equipment, and secure the cabinet after service. Match the arrangement to the installation site and the instruments inside it.
2. Compare the three described equipment configurations
The product description identifies the following builds. Use these selector cards to compare the supplied configuration descriptions; final contents and the orderable combination must be confirmed by TPS.
The electrical parts listed for one build should not be assumed to accompany another. In particular, distinguish the variant-specific grounded copper plate from the separately described grounding-bar and bonding arrangements.
3. Check the mechanical interface beyond the 24U label
For a 19 inch rack cabinet, nominal mounting width is only one interface. The supplied product data lists 482.6 mm width and 512.5 mm frame spacing. Confirm the drawing references for these dimensions, together with rail positions, equipment supports, mounting holes, and usable installation depth.
| Feature | Published information or required confirmation |
|---|---|
| Construction | Powder-coated sheet steel, RAL 7035; reinforced doors. |
| Shop depth options | 760 mm or 1070 mm external depth, subject to the selected combination. |
| Supports | 6 × 3U or 4 × 4U brackets per side, depending on configuration. |
| Hardware | TS007 lock-rod fasteners, including 4 × M6 × 12 screws; TS008 side connectors. |
| Transport | Wooden-box packaging; confirm packed dimensions and handling requirements. |
The IEC 60297 technical report explains the context of 19-inch mechanical structures. Sharing this format does not establish compatibility with every server rail or industrial chassis. Provide equipment drawings and check connector clearance at both ends.
Separate rack height from the supplied support layout
The 24U designation is not a promise that every described bracket arrangement provides 24U of contiguous usable mounting space. Six 3U positions represent 18U, while four 4U positions represent 16U. These counts describe the listed support arrangement, not a complete cabinet utilization drawing. Request the actual layout before allocating instruments.
For factory edge-computing projects, build a front and rear elevation before ordering. Show each chassis, support level, cable exit, and reserved space. Review this drawing with the installer so that the purchased support arrangement matches the assembly sequence, particularly when devices use different mounting methods.
4. Plan weight, access, and optional mobility
The listed net weights are 140–147 kg across the three builds. These are enclosure/configuration weights, not permissible equipment payloads. Obtain the supported load, load distribution, anchoring requirements, and any limits for extended equipment from TPS for the chosen assembly.
Optional four-piece GD-80 height-adjustable castor equipment is described with Fuma bearings. Confirm whether it is included in your quotation and how the installed cabinet is supported in operation. Do not assume a floor-standing description establishes stability under every load or while equipment is being removed.
Check access routes, floor conditions, door sweep, service clearance, and delivery handling. An external-depth choice affects both the installation footprint and the space left for connectors, not just the appearance of the cabinet. Include those site conditions in the purchase specification.
5. Treat rack cable management as part of equipment integration
The described package includes a cable tray and mounting bars, providing a starting point for rack cable management. Confirm the tray position, cable-entry arrangement, supports, and final bill of materials. Plan power, communication, and sensitive signal routes around the installed equipment and its instructions.
Provide room for connector bodies, bend limits, retention, and service loops. Door-mounted connections need a controlled movement path; cables should not be pinched at hinges or pulled by opening the door. Keep access to locking hardware and replaceable instruments clear.
For an industrial computer cabinet, include peripheral connections and maintenance tasks in the layout. A computer that fits mechanically can still be difficult to replace when the connector bundle or neighboring equipment blocks its removal. Review the complete assembly using representative cables.
6. Match the cabinet to the thermal and environmental conditions
A 24U network cabinet can house different combinations of switches, computing equipment, and power modules. Start thermal planning with the losses released inside the enclosure and the permitted inlet temperatures of each device. Rack height alone does not define a cooling capacity.
Map intake and exhaust directions, neighboring heat sources, and the airflow restrictions created by equipment and cables. Where ventilation or cooling accessories are needed, establish their mounting and operating conditions before finalizing the configuration. An open base or perforated door does not, by itself, demonstrate an adequate thermal result.
No specific IP rating is established by the supplied brief. If the industrial network enclosure must address dust or moisture, specify the required protection and request evidence for the completed arrangement. IEC 60529 addresses IP classification; doors, openings, cooling assemblies, and cable entries must be considered together.
Compare cabinet choices and discuss your installation environment →
7. Define electrical options and bonding scope explicitly
The shop selector distinguishes Frame, Cabling, and Cabling with Emergency Stop, alongside external-depth and 3U/4U reference choices. These selector fields and the descriptive build names require an agreed ordering configuration; not every displayed combination should be assumed available.
The Mixed build lists an M32-PV actuator and two Siemens door contacts. The 3U and 4U descriptions list different ABB breaker references and quantities. Those component names do not establish the complete protection scheme, emergency-stop function, or suitability for a particular supply network.
Confirm grounding-bar details, the applicable copper-plate arrangement, protective bonding, and electrical drawings. The supplied terminal notation “1 × 3V/V AC” needs clarification; do not infer a voltage or wiring system from it. Power supplies and output copper bars require project-specific consultation.
8. Request evidence for the configuration you will receive
Use a document checklist for the exact cabinet and installed electrical content. Identify the product reference, variant, drawing revision, intended market, and any required declarations, test reports, or certificate references. Where CE, UL, VDE, CCC, or SAA evidence is part of procurement, specify the document and covered assembly rather than relying on a list of marks.
The broader TPS 19-inch cabinet and chassis portfolio includes customizable projects. Its engineering options should not be transferred automatically to every RA1127 order. Confirm the agreed scope for your application.
UL’s explanation of control-panel certification scope also illustrates the distinction between a panel and the connected equipment. An enclosure purchase does not settle the assessment of the complete integrated system.
Make document ownership explicit: who supplies the cabinet drawing, who releases the installed electrical arrangement, and who assesses the final system. This prevents an unassigned interface from remaining open when the equipment reaches installation.
9. Decide whether 15U, 24U, or 42U best fits the project
Choose by the populated equipment plan and expansion allowance, not height alone. The TPS 15U cabinet is worth reviewing for a smaller layout. The TPS 42U cabinet provides an alternative when more rack height is needed.
Compare each model’s confirmed dimensions, support concept, payload, options, and access requirements independently. A larger model’s load rating or included castors should not be carried over to the 24U product. The right selection is the configuration that accommodates equipment, connections, maintenance, and the intended site.
10. Send an RFQ that can become an installation-ready order
- Product: RA1127 / BJ9900098, required depth, support arrangement, and quantity.
- Equipment: chassis dimensions, mass, support method, connector envelope, and removal access.
- Environment: ambient conditions, heat losses, cooling concept, and required enclosure protection.
- Electrical scope: frame-only or cabling requirements, protective devices, bonding, and optional safety functions.
- Documentation: assembly drawings, variant bill of materials, acceptance checks, and market-specific evidence.
- Delivery: wooden-box dimensions, empty or populated shipping condition, destination, and handling constraints.
Request a quotation that distinguishes the cabinet, optional hardware, electrical integration, and any special documentation or testing. Confirm availability, lead time, price basis, and the final orderable combination directly with TPS before ordering or payment. Keep a released configuration record for repeat purchases.
For a pilot order, agree what will be reviewed on receipt: supplied accessories, door operation, equipment fit, labels, and documentation. Assign responsibility for resolving deviations before the same build is repeated. This gives procurement a clear acceptance basis and gives engineering a repeatable reference.
11. FAQ
Is the 140–147 kg figure a load rating?
No. It is the published net-weight range for the described configurations. Request a separate payload and support specification for the selected build.
Are GD-80 castors standard?
They are described as optional. Confirm inclusion, support arrangement, and operating limitations in the quotation.
Does every configuration include the grounded copper plate?
The description includes it for the Mixed and 3U versions, but not the 4U version. Confirm the separate grounding-bar and bonding scope.
Does 760 mm external depth guarantee equipment compatibility?
No. Check usable depth, supports, connectors, bend space, and service access against the approved assembly drawing.