{"id":19376,"date":"2026-11-16T09:00:00","date_gmt":"2026-11-16T08:00:00","guid":{"rendered":"https:\/\/tps-elektronik.com\/?p=19376"},"modified":"2026-10-29T09:04:56","modified_gmt":"2026-10-29T08:04:56","slug":"how-to-assemble-iec-60320-c19-c20-high-current-power-cords-for-data-center-server-and-pdu-connections-with-tps","status":"publish","type":"post","link":"https:\/\/tps-elektronik.com\/fr\/how-to-assemble-iec-60320-c19-c20-high-current-power-cords-for-data-center-server-and-pdu-connections-with-tps\/","title":{"rendered":"Wie konfektioniert man IEC 60320 C19\/C20-Hochstrom-Netzkabel f\u00fcr Server- und PDU-Anschl\u00fcsse in Rechenzentren mithilfe von TPS?"},"content":{"rendered":"<article class=\"blog-post\" lang=\"de\"><header>\n<p>Systemintegratoren, Schaltschrankbauer und Beschaffungsteams in Rechenzentrumsprojekten verlieren selten Zeit, weil die Server- oder PDU-Spezifikation falsch ist. Sie verlieren sie, wenn ein Standard-1,8-Meter-Kabel 1,5 Meter \u00dcberschuss hinter einem 42-HE-Rack hinterl\u00e4sst, wenn ein generischer C19-Stecker unter Vibration in einem Hochdichterack locker wird, oder wenn der Kabelmantel die LSZH-Anforderung nicht erf\u00fcllt, die das Brandschutzkonzept der Anlage voraussetzt.<\/p>\n<p>Die <a href=\"https:\/\/tps-elektronik.com\/services\/ems\/kabelkonfektion\/\">Kabelkonfektionsdienste<\/a> von TPS Elektronik sind darauf ausgelegt, diese L\u00fccke zu schlie\u00dfen: IEC 60320 C19\/C20-Hochstromkabel mit individuellen L\u00e4ngen, LSZH- oder PVC-Mantelauswahl, korrektem Leiterquerschnitt f\u00fcr 16A- und 20A-Betrieb und dokumentierter Crimp- und elektrischer Pr\u00fcfung\u2014vom einzelnen Rack-Aufbau bis zum Multi-Standort-Rollout.<\/p>\n<p><a class=\"cta-primary\" href=\"https:\/\/tps-elektronik.com\/services\/ems\/kabelkonfektion\/\">Besprechen Sie Ihre C19\/C20-Kabelanforderungen mit TPS \u2192<\/a><\/p>\n<\/header><nav class=\"toc\" aria-label=\"Inhaltsverzeichnis\">\n<h2 id=\"toc\">Inhaltsverzeichnis<\/h2>\n<ol>\n<li><a href=\"#was-c19-c20-ist\">Was IEC 60320 C19\/C20 tats\u00e4chlich spezifiziert<\/a>\n<ol>\n<li><a href=\"#nennwerte\">16A versus 20A: der IEC- und UL\/CSA-Unterschied<\/a><\/li>\n<li><a href=\"#temperatur\">70\u00b0C Stifttemperatur und was sie f\u00fcr das Kabel bedeutet<\/a><\/li>\n<\/ol>\n<\/li>\n<li><a href=\"#warum-standardkabel-versagen\">Warum ein Standard-C19-Kabel in einem Hochdichterack versagt<\/a>\n<ol>\n<li><a href=\"#laenge\">L\u00e4nge und Kabelmanagement<\/a><\/li>\n<li><a href=\"#querschnitt\">Leiterquerschnitt und Spannungsabfall<\/a><\/li>\n<li><a href=\"#mantel\">Mantelmaterial: PVC versus LSZH<\/a><\/li>\n<\/ol>\n<\/li>\n<li><a href=\"#konfektionsprozess\">Wie TPS ein C19\/C20-Hochstromkabel konfektioniert<\/a>\n<ol>\n<li><a href=\"#schneiden\">Schneiden, Abisolieren und Leiteraufbereitung<\/a><\/li>\n<li><a href=\"#crimp\">Crimpanschluss und Zugpr\u00fcfungsverifikation<\/a><\/li>\n<li><a href=\"#pruefung\">Elektrische Pr\u00fcfung und Dokumentation<\/a><\/li>\n<\/ol>\n<\/li>\n<li><a href=\"#anwendung\">Anwendungshinweise: Server-, PDU- und USV-Anschl\u00fcsse<\/a><\/li>\n<li><a href=\"#rfq-checkliste\">RFQ-Checkliste<\/a><\/li>\n<li><a href=\"#faq\">FAQ<\/a><\/li>\n<\/ol>\n<\/nav>\n<section id=\"was-c19-c20-ist\">\n<h2>1. Was IEC 60320 C19\/C20 tats\u00e4chlich spezifiziert<\/h2>\n<p>IEC 60320-1 definiert das Normblatt f\u00fcr Ger\u00e4testecker. Der C19 ist die weibliche kabelmontierte Kupplung; der C20 ist der entsprechende m\u00e4nnliche Ger\u00e4testecker am Ger\u00e4t. Sie sind so kodiert, dass ein C19 nicht mit einem C14-Ger\u00e4testecker verbunden werden kann und umgekehrt\u2014eine physische Schutzma\u00dfnahme, die verhindert, dass ein 16A-Stecker an einem Stromkreis mit niedrigerer Bemessung verwendet wird.<\/p>\n<p>Das C19\/C20-Paar ist die Standard-Hochstromschnittstelle f\u00fcr Rack-PDUs, Hochleistungsserver, Storage-Arrays und USV-Ausg\u00e4nge. Es verwendet eine horizontale Stiftorientierung und einen rechteckigen K\u00f6rper, der es von der kleineren C13\/C14-Schnittstelle mit vertikalen Stiften unterscheidet.<\/p>\n<h3 id=\"nennwerte\">1.1 16A versus 20A: der IEC- und UL\/CSA-Unterschied<\/h3>\n<p>Nach IEC 60320-1 betr\u00e4gt der Nennwert des C19\/C20 <strong>16A bei 250VAC<\/strong>. Nach UL 60320-1 und CSA C22.2 Nr. 60320-1 wird dieselbe Steckerfamilie f\u00fcr <strong>20A bei 250VAC<\/strong> zertifiziert. Dies ist kein Widerspruch; es spiegelt unterschiedliche regionale Normen und Pr\u00fcfbedingungen wider. F\u00fcr einen Rechenzentrumseinsatz bedeutet dies, dass der Stromnennwert des Steckers mit dem Schutz des Abzweigstromkreises und der regionalen Zertifizierungsanforderung abgestimmt sein muss\u2014nicht einfach mit der IEC-Nummer des Steckers.<\/p>\n<p>Ein als 16A gekennzeichnetes Kabel kann f\u00fcr einen europ\u00e4ischen 16A-PDU-Abzweig v\u00f6llig ausreichend sein, aber dieselbe Kabelkonstruktion muss gegen die 20A-UL-Anforderung gepr\u00fcft werden, wenn sie in einem nordamerikanischen Rack mit 20A-Schutz eingesetzt wird. Die Zertifizierung des Steckers, der Leiterquerschnitt und der \u00dcberstromschutz m\u00fcssen konsistent sein.<\/p>\n<h3 id=\"temperatur\">1.2 70\u00b0C Stifttemperatur und was sie f\u00fcr das Kabel bedeutet<\/h3>\n<p>Standard-C19\/C20-Stecker sind f\u00fcr eine Stifttemperatur von <strong>70\u00b0C<\/strong> ausgelegt, in den Normen als \u201ef\u00fcr kalte Bedingungen\u201c bezeichnet. Die Stifttemperaturbewertung ist nicht identisch mit der Manteltemperaturbewertung des Kabels. Ein Kabel kann einen Mantel haben, der f\u00fcr 70\u00b0C oder h\u00f6her bewertet ist, aber die Steckerschnittstelle selbst ist das begrenzende Element in einem Schrank mit hoher Umgebungstemperatur.<\/p>\n<p>In einem Warmgang oder einer dicht gepackten PDU kann die Steckerstifttemperatur \u00fcber die Umgebungstemperatur steigen, verursacht durch Kontaktwiderstand und benachbarte Last. Die Kabelkonstruktion muss daher die 70\u00b0C-Grenze des Steckers respektieren, und die Installation muss vermeiden, stromf\u00fchrende Kabel so eng zu b\u00fcndeln, dass die Steckertemperatur ihre Bemessung \u00fcberschreitet. Dies ist eine technische Randbedingung, kein Beschaffungsdetail.<\/p>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-19480\" src=\"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/10\/C19-C20-Power-Cord-Assembly-Rack-PDU-Data-Center-1.jpg\" alt=\"C19 C20 Power Cord Assembly Rack PDU Data Center\" width=\"1920\" height=\"1079\" \/><\/p>\n<p><a class=\"cta-primary\" href=\"https:\/\/tps-elektronik.com\/services\/ems\/kabelkonfektion\/\">TPS-Kabelkonfektionsdienste erkunden \u2192<\/a><\/p>\n<\/section>\n<section id=\"warum-standardkabel-versagen\">\n<h2>2. Warum ein Standard-C19-Kabel in einem Hochdichterack versagt<\/h2>\n<p>Ein handels\u00fcbliches C19-Kabel ist f\u00fcr eine generische 1,8\u20132,5-Meter-Strecke ausgelegt. In einem Hochdichterack bricht diese Annahme in drei vorhersehbarer Weise.<\/p>\n<h3 id=\"laenge\">2.1 L\u00e4nge und Kabelmanagement<\/h3>\n<p>Ein 2,5-Meter-Kabel vom Server zur vertikalen PDU hinterl\u00e4sst \u00fcbersch\u00fcssiges Kabel, das aufgewickelt, gebunden und verwaltet werden muss. Der \u00dcberschuss blockiert den Luftstrom, erh\u00f6ht das Gewicht des Kabelmanagement-Arms und erschwert den Wartungszugang. Umgekehrt zwingt ein 10cm zu kurzes Kabel die PDU in eine suboptimale Montageposition und verschwendet H\u00f6heneinheiten. TPS fertigt Kabel in der gemessenen L\u00e4nge, die f\u00fcr das spezifische Rack-Layout erforderlich ist, mit definierter Serviceschlaufe wo n\u00f6tig.<\/p>\n<h3 id=\"querschnitt\">2.2 Leiterquerschnitt und Spannungsabfall<\/h3>\n<p>Die Standard-EU-Konstruktion f\u00fcr ein 16A-C19\/C20-Kabel ist <strong>3G1,5mm\u00b2<\/strong> (drei Leiter, je 1,5mm\u00b2) in einem H05VV-F- oder H05Z1Z1-F-Mantel. F\u00fcr 20A-Betrieb oder l\u00e4ngere Strecken, bei denen der Spannungsabfall z\u00e4hlt, wird <strong>12AWG<\/strong> verwendet. Die Querschnittswahl ist nicht austauschbar: Ein 1,5mm\u00b2-Leiter, der 20A kontinuierlich f\u00fchrt, wird hei\u00dfer als ein 12AWG-Leiter, und die Steckerstifttemperatur steigt entsprechend.<\/p>\n<p>Die Spannungsabfallberechnung ist einfach. Eine 3-Meter-Strecke aus 1,5mm\u00b2-Kupfer bei 16A hat einen Hin- und R\u00fcckwiderstand von etwa 0,07\u03a9, was einen Abfall von etwa 1,1V erzeugt\u2014weniger als 0,5% von 250V, was akzeptabel ist. Bei 20A \u00fcber eine l\u00e4ngere Strecke wird der Abfall signifikant und der Querschnitt muss erh\u00f6ht werden. Deshalb sollte das Kabel mit der tats\u00e4chlichen Last und L\u00e4nge spezifiziert werden, nicht aus einem Katalog kopiert.<\/p>\n<h3 id=\"mantel\">2.3 Mantelmaterial: PVC versus LSZH<\/h3>\n<p>PVC (H05VV-F) ist die kosteng\u00fcnstigere Option und mechanisch robust. LSZH (H05Z1Z1-F, low smoke zero halogen) ist die Spezifikation f\u00fcr Rechenzentren, deren Brandschutzkonzept begrenzte Rauchentwicklung und keine korrosive Halogenfreisetzung im Brandfall voraussetzt. Der LSZH-Mantel hat eine etwas andere Flexibilit\u00e4t und Biegeverhalten, und der Steckeranschluss muss f\u00fcr die spezifische Mantelmischung validiert werden. TPS bietet beide an und dokumentiert den Manteltyp auf dem Kabeletikett.<\/p>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-19475\" src=\"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/10\/IEC-60320-C19-C20-Connector-Rating-16A-20A-2.jpg\" alt=\"IEC 60320 C19 C20 Connector Rating 16A 20A\" width=\"1920\" height=\"1079\" \/><\/p>\n<p><a class=\"cta-primary\" href=\"https:\/\/tps-elektronik.com\/services\/ems\/kabelkonfektion\/\">Angebot f\u00fcr C19\/C20-Kabel anfordern \u2192<\/a><\/p>\n<\/section>\n<section id=\"konfektionsprozess\">\n<h2>3. Wie TPS ein C19\/C20-Hochstromkabel konfektioniert<\/h2>\n<p>Der Kabelkonfektions-Workflow von TPS folgt dem IPC\/WHMA-A-620-Standard f\u00fcr Kabel- und Kabelbaumkonfektionen. F\u00fcr ein C19\/C20-Hochstromkabel sind die kritischen Prozessschritte Leiteraufbereitung, Crimpanschluss und elektrische Verifikation.<\/p>\n<h3 id=\"schneiden\">3.1 Schneiden, Abisolieren und Leiteraufbereitung<\/h3>\n<p>Das Kabel wird auf die spezifizierte L\u00e4nge mit einer Toleranz geschnitten, die durch das Rack-Layout definiert ist. Der Au\u00dfenmantel wird auf das Ma\u00df abisoliert, das die Zugentlastung des Steckers erfordert, und die einzelnen Leiter werden auf die Crimph\u00fclsenl\u00e4nge abisoliert. Bei LSZH-M\u00e4nteln werden Abisolierkraft und Klingengeometrie angepasst, weil die halogenfreie Mischung sich anders verh\u00e4lt als PVC. Leiterlitzen d\u00fcrfen nicht gekerbt werden; eine gekerbte Litze reduziert den stromf\u00fchrenden Querschnitt und erzeugt einen lokalen Hotspot.<\/p>\n<h3 id=\"crimp\">3.2 Crimpanschluss und Zugpr\u00fcfungsverifikation<\/h3>\n<p>Die C19-Steckerklemmen werden mit einem kalibrierten Crimpwerkzeug und der vom Klemmenhersteller spezifizierten Crimph\u00f6he auf die Leiter gecrimpt. Der Crimp wird stichprobenartig durch Zugpr\u00fcfung verifiziert, und die Zugkraft muss der Spezifikation des Klemmenherstellers entsprechen. Ein visuell akzeptabler, aber untercrimpter Anschluss entwickelt mit der Zeit Kontaktwiderstand; ein \u00fcbercrimpter Anschluss bricht Litzen. Beide Fehlermodi werden durch Zugpr\u00fcfung erkannt, nicht durch Sichtpr\u00fcfung allein.<\/p>\n<p>Das Steckergeh\u00e4use wird dann montiert und die Zugentlastung eingerastet. Das Kabel muss die spezifizierte Zugkraft auf das Kabel aushalten, ohne die Last auf die Crimpklemmen zu \u00fcbertragen.<\/p>\n<h3 id=\"pruefung\">3.3 Elektrische Pr\u00fcfung und Dokumentation<\/h3>\n<p>Jedes Kabel wird elektrisch auf Durchgang, korrekte Polarit\u00e4t (Au\u00dfenleiter, Neutralleiter, Schutzleiter) und Isolationswiderstand zwischen den Leitern sowie zwischen Leitern und Schutzleiter gepr\u00fcft. Bei Hochstromkabeln liefert eine Kontaktwiderstandsmessung an jedem Leiter einen fr\u00fchen Hinweis auf einen schlechten Crimp. Das Pr\u00fcfprotokoll begleitet die Lieferung und kann in der Inbetriebnahmedokumentation des Rechenzentrums referenziert werden.<\/p>\n<p>Der breitere Kabelkonfektionsumfang von TPS umfasst <a href=\"https:\/\/tps-elektronik.com\/fr\/bnc-stecker-kompletter-ratgeber\/\">BNC-Steckerkonfektionen<\/a> f\u00fcr Test und Messung, <a href=\"https:\/\/tps-elektronik.com\/fr\/sma-steckverbinder-typen-anwendungen-spezifikationen\/\">SMA-Steckerkonfektionen<\/a> f\u00fcr HF und <a href=\"https:\/\/tps-elektronik.com\/ems-glasfaserkabelbaugruppen\/\">Glasfaserkabelbaugruppen<\/a> f\u00fcr Hochbandbreitenverbindungen. Die <a href=\"https:\/\/tps-elektronik.com\/ems-kabelkonfektion-geprueft-dokumentiert-rfq-ready\/\">Ressource zu gepr\u00fcften und dokumentierten Kabelkonfektionen<\/a> beschreibt den Qualit\u00e4ts-Workflow, der f\u00fcr diese Produktfamilien gilt.<\/p>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-19470\" src=\"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/10\/LSZH-C19-C20-Cable-3G1.5mm\u00b2-12AWG-Cross-Section-3.jpg\" alt=\"LSZH C19 C20 Cable 3G1.5mm\u00b2 12AWG Cross Section\" width=\"1920\" height=\"1079\" \/><\/p>\n<p><a class=\"cta-primary\" href=\"https:\/\/tps-elektronik.com\/services\/ems\/kabelkonfektion\/\">Ihre Kabelkonfektions-RFQ einreichen \u2192<\/a><\/p>\n<\/section>\n<section id=\"anwendung\">\n<h2>4. Anwendungshinweise: Server-, PDU- und USV-Anschl\u00fcsse<\/h2>\n<p>Dieselbe C19\/C20-Steckerfamilie wird in drei unterschiedlichen Verbindungsszenarien eingesetzt, und jedes hat eine andere Kabelanforderung.<\/p>\n<ul>\n<li><strong>Server zu Rack-PDU:<\/strong> Die h\u00e4ufigste Hochdichteverbindung. Die L\u00e4nge ergibt sich aus dem vertikalen Abstand zwischen Server-Eingang und PDU-Ausgang plus Serviceschlaufe. Farbkodierung (blau f\u00fcr Prim\u00e4rstrom, rot f\u00fcr Redundanz) ist eine praktische Ma\u00dfnahme zur Reduzierung von Wartungsfehlern.<\/li>\n<li><strong>PDU zu USV:<\/strong> Eine h\u00f6here Stromverbindung, oft 20A oder 32A je nach USV-Bemessung. Leiterquerschnitt und Steckerzertifizierung m\u00fcssen zum USV-Ausgangsschutz passen. Dies ist die Verbindung, bei der der regionale 16A\/20A-Unterschied am ehesten zu einem Compliance-Problem f\u00fchrt.<\/li>\n<li><strong>USV zu Wand oder Busway:<\/strong> Oft eine festverdrahtete oder spezialisierte Verbindung, kein C19\/C20-Kabel. Wenn hier ein C19\/C20 verwendet wird, m\u00fcssen der vorgelagerte Schutz und die Steckerbemessung koordiniert werden.<\/li>\n<\/ul>\n<p>F\u00fcr Hochdichteracks bietet eine verriegelnde C19-Variante (manchmal C19-Lock genannt) zus\u00e4tzliche Halterung, wo Vibration oder versehentliche Ber\u00fchrung ein Risiko darstellen. TPS kann verriegelnde und abgewinkelte Varianten liefern, wo die zertifizierte Version des Steckerherstellers verf\u00fcgbar ist.<\/p>\n<\/section>\n<section id=\"rfq-checkliste\">\n<h2>5. RFQ-Checkliste<\/h2>\n<p>Um Angebotserstellung und Engineering-Pr\u00fcfung f\u00fcr ein <strong>power cable for power supply<\/strong>\u00a0mit IEC 60320 C19\/C20-Steckern zu beschleunigen, geben Sie Folgendes an:<\/p>\n<ul>\n<li><strong>Anschlusspunkte:<\/strong> Welches Ende C19 und welches C20 ist, und ob eine verriegelnde oder abgewinkelte Variante erforderlich ist<\/li>\n<li><strong>Strom und Spannung:<\/strong> 16A- oder 20A-Betrieb und die regionale Zertifizierungsanforderung (IEC, UL, CSA)<\/li>\n<li><strong>Leiterquerschnitt:<\/strong> 3G1,5mm\u00b2, 12AWG oder ein spezifizierter Querschnitt basierend auf Last und L\u00e4nge<\/li>\n<li><strong>Mantelmaterial:<\/strong> PVC (H05VV-F) oder LSZH (H05Z1Z1-F) und jede Farbkodierungsanforderung<\/li>\n<li><strong>L\u00e4nge:<\/strong> Gemessene L\u00e4nge pro Rack-Layout, mit Toleranz und Serviceschlaufenanforderung<\/li>\n<li><strong>Pr\u00fcfdokumentation:<\/strong> Durchgangs-, Polarit\u00e4ts-, Isolationswiderstands- und Kontaktwiderstandsbericht<\/li>\n<li><strong>Volumen:<\/strong> Prototyp-Rack-Menge, Serien-Rollout-Volumen und Lieferplan<\/li>\n<\/ul>\n<p>Die Angabe dieser Details reduziert Kl\u00e4rungszyklen. Das Engineering-Team von TPS kann Steckerzertifizierungspr\u00fcfung, Querschnittsauswahl und L\u00e4ngenplanung als Teil des RFQ-Prozesses unterst\u00fctzen.<\/p>\n<p><a class=\"cta-primary\" href=\"https:\/\/tps-elektronik.com\/services\/ems\/kabelkonfektion\/\">Ihre C19\/C20-Kabel-RFQ einreichen \u2192<\/a><\/p>\n<\/section>\n<section id=\"faq\">\n<h2>6. FAQ<\/h2>\n<div>\n<h3>Welchen Stromnennwert haben IEC 60320 C19\/C20?<\/h3>\n<div>Nach IEC 60320-1 betr\u00e4gt der Nennwert 16A bei 250VAC. Nach UL 60320-1 und CSA C22.2 Nr. 60320-1 wird dieselbe Steckerfamilie f\u00fcr 20A bei 250VAC zertifiziert. Die Zertifizierung des Steckers, der Leiterquerschnitt und der Abzweigstromkreisschutz m\u00fcssen f\u00fcr die Einsatzregion konsistent sein.<\/div>\n<\/div>\n<div>\n<h3>Welchen Leiterquerschnitt sollte ein C19\/C20-Kabel verwenden?<\/h3>\n<div>Eine Standard-16A-EU-Konstruktion verwendet 3G1,5mm\u00b2 (H05VV-F oder H05Z1Z1-F). F\u00fcr 20A-Betrieb oder l\u00e4ngere Strecken, bei denen der Spannungsabfall z\u00e4hlt, wird 12AWG verwendet. Der Querschnitt sollte aus der tats\u00e4chlichen Last und L\u00e4nge gew\u00e4hlt werden, nicht aus einem Katalog kopiert.<\/div>\n<\/div>\n<div>\n<h3>Warum ist LSZH f\u00fcr Rechenzentrums-Netzkabel wichtig?<\/h3>\n<div>LSZH (H05Z1Z1-F) begrenzt die Rauchentwicklung und vermeidet korrosive Halogenfreisetzung im Brandfall. Es wird dort spezifiziert, wo das Brandschutzkonzept der Anlage begrenzte Rauchentwicklung und keine Halogens\u00e4uren voraussetzt. PVC (H05VV-F) ist kosteng\u00fcnstiger und mechanisch robust, bietet aber nicht dasselbe Brandschutzprofil.<\/div>\n<\/div>\n<div>\n<h3>Kann TPS C19\/C20-Kabel in individuellen L\u00e4ngen liefern?<\/h3>\n<div>Ja. Die L\u00e4nge wird aus dem Rack-Layout spezifiziert, mit Toleranz- und Serviceschlaufenanforderungen. Individuelle L\u00e4ngen eliminieren das \u00fcbersch\u00fcssige Kabel, das den Luftstrom blockiert, und das zu kurze Kabel, das eine suboptimale PDU-Position erzwingt.<\/div>\n<\/div>\n<div>\n<h3>Wie wird die Crimpqualit\u00e4t verifiziert?<\/h3>\n<div>Die Crimph\u00f6he wird durch ein kalibriertes Werkzeug und die Spezifikation des Klemmenherstellers kontrolliert. Die Zugpr\u00fcfung erfolgt stichprobenartig, und jedes Kabel erh\u00e4lt eine Durchgangs-, Polarit\u00e4ts- und Isolationswiderstandspr\u00fcfung. Die Kontaktwiderstandsmessung bietet eine zus\u00e4tzliche Pr\u00fcfung f\u00fcr Hochstromkonfektionen.<\/div>\n<\/div>\n<\/section>\n<footer style=\"background: #2d5797; padding: 30px; border-radius: 14px; margin-top: 40px;\">\n<p style=\"color: #ffffff; font-size: 16px; line-height: 1.6; margin: 0;\"><strong>N\u00e4chster Schritt:<\/strong> Senden Sie Anschlusspunkte, Stromnennwert, L\u00e4nge und Mantelanforderung. TPS best\u00e4tigt die Steckerzertifizierung, den Leiterquerschnitt und die Pr\u00fcfdokumentation f\u00fcr Ihren Rack-Aufbau. <a style=\"color: #ffffff; font-weight: 600; text-decoration: underline;\" href=\"https:\/\/tps-elektronik.com\/services\/ems\/kabelkonfektion\/\">Ihre C19\/C20-Kabelbewertung anfordern \u2192<\/a><\/p>\n<\/footer><\/article>\n\n<style id=\"wpforms-css-vars-4336-block-77b24620-5c4c-4faa-b148-acc889bdf8ce\">\n\t\t\t\t#wpforms-4336.wpforms-block-77b24620-5c4c-4faa-b148-acc889bdf8ce {\n\t\t\t\t--wpforms-field-size-input-height: 43px;\n--wpforms-field-size-input-spacing: 15px;\n--wpforms-field-size-font-size: 16px;\n--wpforms-field-size-line-height: 19px;\n--wpforms-field-size-padding-h: 14px;\n--wpforms-field-size-checkbox-size: 16px;\n--wpforms-field-size-sublabel-spacing: 5px;\n--wpforms-field-size-icon-size: 1;\n--wpforms-label-size-font-size: 16px;\n--wpforms-label-size-line-height: 19px;\n--wpforms-label-size-sublabel-font-size: 14px;\n--wpforms-label-size-sublabel-line-height: 17px;\n--wpforms-button-size-font-size: 17px;\n--wpforms-button-size-height: 41px;\n--wpforms-button-size-padding-h: 15px;\n--wpforms-button-size-margin-top: 10px;\n\t\t\t}\n\t\t\t<\/style><div class=\"wpforms-container wpforms-container-full wpforms-block wpforms-block-77b24620-5c4c-4faa-b148-acc889bdf8ce wpforms-render-modern\" id=\"wpforms-4336\"><form id=\"wpforms-form-4336\" class=\"wpforms-validate wpforms-form wpforms-ajax-form\" data-formid=\"4336\" method=\"post\" enctype=\"multipart\/form-data\" action=\"\/fr\/wp-json\/wp\/v2\/posts\/19376\" data-token=\"a0df22f68b057d8ad6ede508c1df5553\" data-token-time=\"1795225406\"><noscript class=\"wpforms-error-noscript\">Veuillez activer JavaScript dans votre navigateur pour remplir ce formulaire.<\/noscript><div id=\"wpforms-error-noscript\" style=\"display: none;\">Veuillez activer JavaScript dans votre navigateur pour remplir ce formulaire.<\/div><div class=\"wpforms-field-container\"><div id=\"wpforms-4336-field_1-container\" class=\"wpforms-field wpforms-field-name wpforms-one-half wpforms-first\" data-field-id=\"1\"><label class=\"wpforms-field-label\" for=\"wpforms-4336-field_1\">Name <span class=\"wpforms-required-label\" aria-hidden=\"true\">*<\/span><\/label><input type=\"text\" id=\"wpforms-4336-field_1\" class=\"wpforms-field-large wpforms-field-required\" name=\"wpforms[fields][1]\" aria-errormessage=\"wpforms-4336-field_1-error\" required><\/div><div id=\"wpforms-4336-field_2-container\" class=\"wpforms-field wpforms-field-email\" data-field-id=\"2\"><label class=\"wpforms-field-label\" for=\"wpforms-4336-field_2\">E-Mail <span class=\"wpforms-required-label\" aria-hidden=\"true\">*<\/span><\/label><input type=\"email\" id=\"wpforms-4336-field_2\" class=\"wpforms-field-large wpforms-field-required\" name=\"wpforms[fields][2]\" spellcheck=\"false\" aria-errormessage=\"wpforms-4336-field_2-error\" required><\/div><div id=\"wpforms-4336-field_4-container\" class=\"wpforms-field wpforms-field-text\" data-field-id=\"4\"><label class=\"wpforms-field-label\" for=\"wpforms-4336-field_4\"> Firma <span class=\"wpforms-required-label\" aria-hidden=\"true\">*<\/span><\/label><input type=\"text\" id=\"wpforms-4336-field_4\" class=\"wpforms-field-large wpforms-field-required\" name=\"wpforms[fields][4]\" aria-errormessage=\"wpforms-4336-field_4-error\" required><\/div><div id=\"wpforms-4336-field_3-container\" class=\"wpforms-field wpforms-field-textarea\" data-field-id=\"3\"><label class=\"wpforms-field-label\" for=\"wpforms-4336-field_3\">Kurzbeschreibung<\/label><textarea id=\"wpforms-4336-field_3\" class=\"wpforms-field-medium\" name=\"wpforms[fields][3]\" aria-errormessage=\"wpforms-4336-field_3-error\" ><\/textarea><\/div>\t\t<div id=\"wpforms-4336-field_5-container\"\n\t\t\tclass=\"wpforms-field wpforms-field-text\"\n\t\t\tdata-field-type=\"text\"\n\t\t\tdata-field-id=\"5\"\n\t\t\t>\n\t\t\t<label class=\"wpforms-field-label\" for=\"wpforms-4336-field_5\" >Firma Checkboxes Kurzbeschreibung<\/label>\n\t\t\t<input type=\"text\" id=\"wpforms-4336-field_5\" class=\"wpforms-field-medium\" name=\"wpforms[fields][5]\" >\n\t\t<\/div>\n\t\t<div id=\"wpforms-4336-field_6-container\" class=\"wpforms-field wpforms-field-checkbox\" data-field-id=\"6\"><fieldset><legend class=\"wpforms-field-label wpforms-label-hide\" aria-hidden=\"false\">Checkboxes <span class=\"wpforms-required-label\" aria-hidden=\"true\">*<\/span><\/legend><ul id=\"wpforms-4336-field_6\" class=\"wpforms-field-required\"><li class=\"choice-1 depth-1\"><input type=\"checkbox\" id=\"wpforms-4336-field_6_1\" name=\"wpforms[fields][6][]\" value=\"Ich stimme der Verarbeitung meiner Angaben zur Angebotserstellung zu.\" aria-errormessage=\"wpforms-4336-field_6_1-error\" aria-describedby=\"wpforms-4336-field_6-description\" required ><label class=\"wpforms-field-label-inline\" for=\"wpforms-4336-field_6_1\">Ich stimme der Verarbeitung meiner Angaben zur Angebotserstellung zu.<\/label><\/li><\/ul><div id=\"wpforms-4336-field_6-description\" class=\"wpforms-field-description\">Hinweise siehe Datenschutz.<\/div><\/fieldset><\/div><script>\n\t\t\t\t( function() {\n\t\t\t\t\tconst style = document.createElement( 'style' );\n\t\t\t\t\tstyle.appendChild( document.createTextNode( '#wpforms-4336-field_5-container { position: absolute !important; overflow: hidden !important; display: inline !important; height: 1px !important; width: 1px !important; z-index: -1000 !important; padding: 0 !important; } #wpforms-4336-field_5-container input { visibility: hidden; } #wpforms-conversational-form-page #wpforms-4336-field_5-container label { counter-increment: none; }' ) );\n\t\t\t\t\tdocument.head.appendChild( style );\n\t\t\t\t\tdocument.currentScript?.remove();\n\t\t\t\t} )();\n\t\t\t<\/script><\/div><!-- .wpforms-field-container --><div class=\"wpforms-recaptcha-container wpforms-is-turnstile\" ><div class=\"wpforms-turnstile\" data-sitekey=\"0x4AAAAAAFUTE-Rr1O4nxKnU\" data-action=\"FormID-4336\"><\/div><input type=\"text\" name=\"g-recaptcha-hidden\" class=\"wpforms-recaptcha-hidden\" style=\"position:absolute!important;clip:rect(0,0,0,0)!important;height:1px!important;width:1px!important;border:0!important;overflow:hidden!important;padding:0!important;margin:0!important;\" data-rule-turnstile=\"1\"><\/div><div class=\"wpforms-submit-container\" ><input type=\"hidden\" name=\"wpforms[id]\" value=\"4336\"><input type=\"hidden\" name=\"wpforms[time_token]\" value=\"1795225406.101be52e458f85454c7e88a3d8172c2193ea960e029c155f4d1b1b3aec437ea4\"><input type=\"hidden\" name=\"page_title\" value=\"\"><input type=\"hidden\" name=\"page_url\" value=\"https:\/\/tps-elektronik.com\/fr\/wp-json\/wp\/v2\/posts\/19376\"><input type=\"hidden\" name=\"url_referer\" value=\"\"><button type=\"submit\" name=\"wpforms[submit]\" id=\"wpforms-submit-4336\" class=\"wpforms-submit\" data-alt-text=\"Senden...\" data-submit-text=\"Anfrage senden\" aria-live=\"assertive\" value=\"wpforms-submit\">Anfrage senden<\/button><img decoding=\"async\" src=\"https:\/\/tps-elektronik.com\/wp-content\/plugins\/wpforms-lite\/assets\/images\/submit-spin.svg\" class=\"wpforms-submit-spinner\" style=\"display: none;\" width=\"26\" height=\"26\" alt=\"Chargement en cours\"><\/div><\/form><\/div>  <!-- .wpforms-container -->\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Systemintegratoren, Schaltschrankbauer und Beschaffungsteams in Rechenzentrumsprojekten verlieren selten Zeit, weil die Server- oder PDU-Spezifikation falsch ist. Sie verlieren sie, wenn ein Standard-1,8-Meter-Kabel 1,5 Meter \u00dcberschuss hinter einem 42-HE-Rack hinterl\u00e4sst, wenn ein generischer C19-Stecker unter Vibration in einem Hochdichterack locker wird, oder wenn der Kabelmantel die LSZH-Anforderung nicht erf\u00fcllt, die das Brandschutzkonzept der Anlage voraussetzt. Die\u2026 <a href=\"https:\/\/tps-elektronik.com\/fr\/how-to-assemble-iec-60320-c19-c20-high-current-power-cords-for-data-center-server-and-pdu-connections-with-tps\/\">Read More &raquo;<\/a><\/p>\n","protected":false},"author":9,"featured_media":19480,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[60],"tags":[],"class_list":["post-19376","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-nachrichten"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>TPS Power Cable For Power Supply - TPS<\/title>\n<meta name=\"description\" content=\"Power cable for power supply with IEC 60320 C19\/C20 connectors for data center servers and PDUs. Custom lengths, LSZH, 16\/20A.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/tps-elektronik.com\/fr\/how-to-assemble-iec-60320-c19-c20-high-current-power-cords-for-data-center-server-and-pdu-connections-with-tps\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"TPS Power Cable For Power Supply - TPS\" \/>\n<meta property=\"og:description\" content=\"Power cable for power supply with IEC 60320 C19\/C20 connectors for data center servers and PDUs. Custom lengths, LSZH, 16\/20A.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/tps-elektronik.com\/fr\/how-to-assemble-iec-60320-c19-c20-high-current-power-cords-for-data-center-server-and-pdu-connections-with-tps\/\" \/>\n<meta property=\"og:site_name\" content=\"TPS\" \/>\n<meta property=\"article:published_time\" content=\"2026-11-16T08:00:00+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/10\/C19-C20-Power-Cord-Assembly-Rack-PDU-Data-Center-1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1920\" \/>\n\t<meta property=\"og:image:height\" content=\"1079\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Tang Marcus\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u00c9crit par\" \/>\n\t<meta name=\"twitter:data1\" content=\"Tang Marcus\" \/>\n\t<meta name=\"twitter:label2\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data2\" content=\"8 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/fr\\\/how-to-assemble-iec-60320-c19-c20-high-current-power-cords-for-data-center-server-and-pdu-connections-with-tps\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/fr\\\/how-to-assemble-iec-60320-c19-c20-high-current-power-cords-for-data-center-server-and-pdu-connections-with-tps\\\/\"},\"author\":{\"name\":\"Tang Marcus\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/fr\\\/#\\\/schema\\\/person\\\/2c19fd053095d0c1ae253e8e62427b8c\"},\"headline\":\"Wie konfektioniert man IEC 60320 C19\\\/C20-Hochstrom-Netzkabel f\u00fcr Server- und PDU-Anschl\u00fcsse in Rechenzentren mithilfe von TPS?\",\"datePublished\":\"2026-11-16T08:00:00+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/fr\\\/how-to-assemble-iec-60320-c19-c20-high-current-power-cords-for-data-center-server-and-pdu-connections-with-tps\\\/\"},\"wordCount\":1799,\"image\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/fr\\\/how-to-assemble-iec-60320-c19-c20-high-current-power-cords-for-data-center-server-and-pdu-connections-with-tps\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/tps-elektronik.com\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/C19-C20-Power-Cord-Assembly-Rack-PDU-Data-Center-1.jpg\",\"articleSection\":[\"Nachrichten\"],\"inLanguage\":\"fr-FR\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/fr\\\/how-to-assemble-iec-60320-c19-c20-high-current-power-cords-for-data-center-server-and-pdu-connections-with-tps\\\/\",\"url\":\"https:\\\/\\\/tps-elektronik.com\\\/fr\\\/how-to-assemble-iec-60320-c19-c20-high-current-power-cords-for-data-center-server-and-pdu-connections-with-tps\\\/\",\"name\":\"TPS Power Cable For Power Supply - TPS\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/fr\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/fr\\\/how-to-assemble-iec-60320-c19-c20-high-current-power-cords-for-data-center-server-and-pdu-connections-with-tps\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/fr\\\/how-to-assemble-iec-60320-c19-c20-high-current-power-cords-for-data-center-server-and-pdu-connections-with-tps\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/tps-elektronik.com\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/C19-C20-Power-Cord-Assembly-Rack-PDU-Data-Center-1.jpg\",\"datePublished\":\"2026-11-16T08:00:00+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/fr\\\/#\\\/schema\\\/person\\\/2c19fd053095d0c1ae253e8e62427b8c\"},\"description\":\"Power cable for power supply with IEC 60320 C19\\\/C20 connectors for data center servers and PDUs. Custom lengths, LSZH, 16\\\/20A.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/fr\\\/how-to-assemble-iec-60320-c19-c20-high-current-power-cords-for-data-center-server-and-pdu-connections-with-tps\\\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/tps-elektronik.com\\\/fr\\\/how-to-assemble-iec-60320-c19-c20-high-current-power-cords-for-data-center-server-and-pdu-connections-with-tps\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/fr\\\/how-to-assemble-iec-60320-c19-c20-high-current-power-cords-for-data-center-server-and-pdu-connections-with-tps\\\/#primaryimage\",\"url\":\"https:\\\/\\\/tps-elektronik.com\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/C19-C20-Power-Cord-Assembly-Rack-PDU-Data-Center-1.jpg\",\"contentUrl\":\"https:\\\/\\\/tps-elektronik.com\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/C19-C20-Power-Cord-Assembly-Rack-PDU-Data-Center-1.jpg\",\"width\":1920,\"height\":1079,\"caption\":\"C19 C20 Power Cord Assembly Rack PDU Data Center\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/fr\\\/how-to-assemble-iec-60320-c19-c20-high-current-power-cords-for-data-center-server-and-pdu-connections-with-tps\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Startseite\",\"item\":\"https:\\\/\\\/tps-elektronik.com\\\/fr\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Wie konfektioniert man IEC 60320 C19\\\/C20-Hochstrom-Netzkabel f\u00fcr Server- und PDU-Anschl\u00fcsse in Rechenzentren mithilfe von TPS?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/fr\\\/#website\",\"url\":\"https:\\\/\\\/tps-elektronik.com\\\/fr\\\/\",\"name\":\"TPS\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/tps-elektronik.com\\\/fr\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/fr\\\/#\\\/schema\\\/person\\\/2c19fd053095d0c1ae253e8e62427b8c\",\"name\":\"Tang Marcus\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"TPS Power Cable For Power Supply - TPS","description":"Power cable for power supply with IEC 60320 C19\/C20 connectors for data center servers and PDUs. Custom lengths, LSZH, 16\/20A.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/tps-elektronik.com\/fr\/how-to-assemble-iec-60320-c19-c20-high-current-power-cords-for-data-center-server-and-pdu-connections-with-tps\/","og_locale":"fr_FR","og_type":"article","og_title":"TPS Power Cable For Power Supply - TPS","og_description":"Power cable for power supply with IEC 60320 C19\/C20 connectors for data center servers and PDUs. Custom lengths, LSZH, 16\/20A.","og_url":"https:\/\/tps-elektronik.com\/fr\/how-to-assemble-iec-60320-c19-c20-high-current-power-cords-for-data-center-server-and-pdu-connections-with-tps\/","og_site_name":"TPS","article_published_time":"2026-11-16T08:00:00+00:00","og_image":[{"width":1920,"height":1079,"url":"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/10\/C19-C20-Power-Cord-Assembly-Rack-PDU-Data-Center-1.jpg","type":"image\/jpeg"}],"author":"Tang Marcus","twitter_card":"summary_large_image","twitter_misc":{"\u00c9crit par":"Tang Marcus","Dur\u00e9e de lecture estim\u00e9e":"8 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/tps-elektronik.com\/fr\/how-to-assemble-iec-60320-c19-c20-high-current-power-cords-for-data-center-server-and-pdu-connections-with-tps\/#article","isPartOf":{"@id":"https:\/\/tps-elektronik.com\/fr\/how-to-assemble-iec-60320-c19-c20-high-current-power-cords-for-data-center-server-and-pdu-connections-with-tps\/"},"author":{"name":"Tang Marcus","@id":"https:\/\/tps-elektronik.com\/fr\/#\/schema\/person\/2c19fd053095d0c1ae253e8e62427b8c"},"headline":"Wie konfektioniert man IEC 60320 C19\/C20-Hochstrom-Netzkabel f\u00fcr Server- und PDU-Anschl\u00fcsse in Rechenzentren mithilfe von TPS?","datePublished":"2026-11-16T08:00:00+00:00","mainEntityOfPage":{"@id":"https:\/\/tps-elektronik.com\/fr\/how-to-assemble-iec-60320-c19-c20-high-current-power-cords-for-data-center-server-and-pdu-connections-with-tps\/"},"wordCount":1799,"image":{"@id":"https:\/\/tps-elektronik.com\/fr\/how-to-assemble-iec-60320-c19-c20-high-current-power-cords-for-data-center-server-and-pdu-connections-with-tps\/#primaryimage"},"thumbnailUrl":"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/10\/C19-C20-Power-Cord-Assembly-Rack-PDU-Data-Center-1.jpg","articleSection":["Nachrichten"],"inLanguage":"fr-FR"},{"@type":"WebPage","@id":"https:\/\/tps-elektronik.com\/fr\/how-to-assemble-iec-60320-c19-c20-high-current-power-cords-for-data-center-server-and-pdu-connections-with-tps\/","url":"https:\/\/tps-elektronik.com\/fr\/how-to-assemble-iec-60320-c19-c20-high-current-power-cords-for-data-center-server-and-pdu-connections-with-tps\/","name":"TPS Power Cable For Power Supply - TPS","isPartOf":{"@id":"https:\/\/tps-elektronik.com\/fr\/#website"},"primaryImageOfPage":{"@id":"https:\/\/tps-elektronik.com\/fr\/how-to-assemble-iec-60320-c19-c20-high-current-power-cords-for-data-center-server-and-pdu-connections-with-tps\/#primaryimage"},"image":{"@id":"https:\/\/tps-elektronik.com\/fr\/how-to-assemble-iec-60320-c19-c20-high-current-power-cords-for-data-center-server-and-pdu-connections-with-tps\/#primaryimage"},"thumbnailUrl":"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/10\/C19-C20-Power-Cord-Assembly-Rack-PDU-Data-Center-1.jpg","datePublished":"2026-11-16T08:00:00+00:00","author":{"@id":"https:\/\/tps-elektronik.com\/fr\/#\/schema\/person\/2c19fd053095d0c1ae253e8e62427b8c"},"description":"Power cable for power supply with IEC 60320 C19\/C20 connectors for data center servers and PDUs. Custom lengths, LSZH, 16\/20A.","breadcrumb":{"@id":"https:\/\/tps-elektronik.com\/fr\/how-to-assemble-iec-60320-c19-c20-high-current-power-cords-for-data-center-server-and-pdu-connections-with-tps\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/tps-elektronik.com\/fr\/how-to-assemble-iec-60320-c19-c20-high-current-power-cords-for-data-center-server-and-pdu-connections-with-tps\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/tps-elektronik.com\/fr\/how-to-assemble-iec-60320-c19-c20-high-current-power-cords-for-data-center-server-and-pdu-connections-with-tps\/#primaryimage","url":"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/10\/C19-C20-Power-Cord-Assembly-Rack-PDU-Data-Center-1.jpg","contentUrl":"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/10\/C19-C20-Power-Cord-Assembly-Rack-PDU-Data-Center-1.jpg","width":1920,"height":1079,"caption":"C19 C20 Power Cord Assembly Rack PDU Data Center"},{"@type":"BreadcrumbList","@id":"https:\/\/tps-elektronik.com\/fr\/how-to-assemble-iec-60320-c19-c20-high-current-power-cords-for-data-center-server-and-pdu-connections-with-tps\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Startseite","item":"https:\/\/tps-elektronik.com\/fr\/"},{"@type":"ListItem","position":2,"name":"Wie konfektioniert man IEC 60320 C19\/C20-Hochstrom-Netzkabel f\u00fcr Server- und PDU-Anschl\u00fcsse in Rechenzentren mithilfe von TPS?"}]},{"@type":"WebSite","@id":"https:\/\/tps-elektronik.com\/fr\/#website","url":"https:\/\/tps-elektronik.com\/fr\/","name":"TPS","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/tps-elektronik.com\/fr\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Person","@id":"https:\/\/tps-elektronik.com\/fr\/#\/schema\/person\/2c19fd053095d0c1ae253e8e62427b8c","name":"Tang Marcus"}]}},"_links":{"self":[{"href":"https:\/\/tps-elektronik.com\/fr\/wp-json\/wp\/v2\/posts\/19376","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/tps-elektronik.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/tps-elektronik.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/tps-elektronik.com\/fr\/wp-json\/wp\/v2\/users\/9"}],"replies":[{"embeddable":true,"href":"https:\/\/tps-elektronik.com\/fr\/wp-json\/wp\/v2\/comments?post=19376"}],"version-history":[{"count":3,"href":"https:\/\/tps-elektronik.com\/fr\/wp-json\/wp\/v2\/posts\/19376\/revisions"}],"predecessor-version":[{"id":19484,"href":"https:\/\/tps-elektronik.com\/fr\/wp-json\/wp\/v2\/posts\/19376\/revisions\/19484"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/tps-elektronik.com\/fr\/wp-json\/wp\/v2\/media\/19480"}],"wp:attachment":[{"href":"https:\/\/tps-elektronik.com\/fr\/wp-json\/wp\/v2\/media?parent=19376"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/tps-elektronik.com\/fr\/wp-json\/wp\/v2\/categories?post=19376"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/tps-elektronik.com\/fr\/wp-json\/wp\/v2\/tags?post=19376"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}