{"id":19211,"date":"2026-11-13T01:30:53","date_gmt":"2026-11-13T00:30:53","guid":{"rendered":"https:\/\/tps-elektronik.com\/?p=19211"},"modified":"2026-10-26T09:14:39","modified_gmt":"2026-10-26T08:14:39","slug":"how-to-convert-220vac-to-stable-24vdc-for-plc-and-i-o-circuits-in-industrial-control-cabinets-with-tps%ef%bc%9f","status":"publish","type":"post","link":"https:\/\/tps-elektronik.com\/fr\/how-to-convert-220vac-to-stable-24vdc-for-plc-and-i-o-circuits-in-industrial-control-cabinets-with-tps%ef%bc%9f\/","title":{"rendered":"Wie l\u00e4sst sich 220 V AC mithilfe von TPS in eine stabile 24-V-Gleichspannung (24 V DC) f\u00fcr SPS- und E\/A-Stromkreise in industriellen Schaltschr\u00e4nken umwandeln?"},"content":{"rendered":"<article class=\"product-blog\" lang=\"de\"><header>\n<p>F\u00fcr Systemintegratoren, Schaltschrankbauer und ingenieurgetriebene Beschaffungsteams ist die Umwandlung von 220VAC in 24VDC in einem industriellen Steuerungsschrank nicht nur die Auswahl eines Netzteils mit der richtigen Wattzahl.<\/p>\n<p>Es geht auch um Eingangsbereich, Ausgangsstabilit\u00e4t, Restwelligkeit, Schutzverhalten, SELV-Konformit\u00e4t und\u2014entscheidend\u2014darum, ob das gew\u00e4hlte Netzteil f\u00fcr den Dauerbetrieb im Schrank oder f\u00fcr Inbetriebnahme und Test ausgelegt ist.<\/p>\n<p>Das <a href=\"https:\/\/www.shop-tps.com\/de\/shop\/category\/leistungsmodule-zum-einbau-dcdc-bidirectional-194\" target=\"_blank\" rel=\"noopener noreferrer nofollow\"><strong>EA-PS 5080-20A<\/strong><\/a> ist ein programmierbares Tisch-DC-Netzteil mit <strong>90\u2013264VAC-Eingang<\/strong>, <strong>aktiver PFC &gt;0,99<\/strong> und einem Auto-Ranging-Ausgang <strong>0\u201380VDC \/ 0\u201320A \/ 640W<\/strong>. Es ist f\u00fcr Labor-, Test- und Inbetriebnahmeanwendungen konzipiert\u2014nicht als DIN-Schienen-Netzteil f\u00fcr die dauerhafte Schrankinstallation. Dieser Artikel erkl\u00e4rt, wo es passt, wie es f\u00fcr eine stabile 24VDC-Schiene f\u00fcr PLC- und I\/O-Kreise eingestellt wird und wann ein DIN-Schienen-Netzteil die richtige Wahl ist.<\/p>\n<p><a class=\"cta-primary\" href=\"https:\/\/www.shop-tps.com\/de\/shop\/category\/leistungsmodule-zum-einbau-dcdc-bidirectional-194\" target=\"_blank\" rel=\"noopener noreferrer nofollow\">Besprechen Sie Ihre 220VAC-zu-24VDC-Anforderungen mit TPS \u2192<\/a><\/p>\n<\/header><nav class=\"toc\" aria-label=\"Inhaltsverzeichnis\">\n<h2 id=\"toc-de\">Inhaltsverzeichnis<\/h2>\n<ol>\n<li><a href=\"#de-was-erforderlich\">Was 220VAC zu stabilen 24VDC im Steuerungsschrank tats\u00e4chlich erfordert<\/a>\n<ol>\n<li><a href=\"#de-zwei-faelle\">Zwei Anwendungsf\u00e4lle: Inbetriebnahme versus Dauerbetrieb im Schrank<\/a><\/li>\n<li><a href=\"#de-24v-stabilitaet\">Warum 24V-Stabilit\u00e4t f\u00fcr PLC- und I\/O-Kreise z\u00e4hlt<\/a><\/li>\n<\/ol>\n<\/li>\n<li><a href=\"#de-elektrisch\">Elektrische Leistung des EA-PS 5080-20A f\u00fcr 24VDC-PLC-Lasten<\/a>\n<ol>\n<li><a href=\"#de-eingang-pfc\">90\u2013264VAC-Eingang und aktive PFC<\/a><\/li>\n<li><a href=\"#de-ausgang\">Ausgangsregelung, Restwelligkeit und Lastsprungverhalten<\/a><\/li>\n<\/ol>\n<\/li>\n<li><a href=\"#de-integration\">Integration in Schaltschrankbau und Inbetriebnahme<\/a>\n<ol>\n<li><a href=\"#de-verdrahtung\">Verdrahtung, Erdung und SELV-Grenzen<\/a><\/li>\n<li><a href=\"#de-schutz\">Schutzeinstellungen f\u00fcr PLC- und I\/O-Lasten<\/a><\/li>\n<li><a href=\"#de-logging\">Fernsteuerung und Protokollierung w\u00e4hrend der Inbetriebnahme<\/a><\/li>\n<\/ol>\n<\/li>\n<li><a href=\"#de-wann-din\">Wann ein DIN-Schienen-Netzteil die richtige Wahl ist<\/a><\/li>\n<li><a href=\"#de-spezifikationen\">Produktspezifikationen<\/a><\/li>\n<li><a href=\"#de-rfq\">RFQ-Checkliste<\/a><\/li>\n<li><a href=\"#de-faq\">FAQ<\/a><\/li>\n<\/ol>\n<\/nav>\n<section id=\"de-was-erforderlich\">\n<h2>1. Was 220VAC zu stabilen 24VDC im Steuerungsschrank tats\u00e4chlich erfordert<\/h2>\n<p>Eine 24VDC-Schiene, die PLC-CPUs, I\/O-Module, Sensoren und Relais versorgt, muss unter allen Last- und Netzverh\u00e4ltnissen innerhalb der PLC-Eingangstoleranz bleiben. IEC 61131-2 definiert die elektrischen Betriebsbedingungen f\u00fcr speicherprogrammierbare Steuerungen, einschlie\u00dflich des zul\u00e4ssigen Eingangsspannungsbereichs und der \u00dcberbr\u00fcckungsanforderungen. Das Netzteil ist die Komponente, die die Schiene in diesem Fenster halten muss.<\/p>\n<p>Das Netzteil muss au\u00dferdem einen SELV-Ausgang bereitstellen, die anwendbare EMV-Norm f\u00fcr die Installationsumgebung erf\u00fcllen und\u2014bei dauerhafter Schrankinstallation\u2014f\u00fcr den Dauerbetrieb bei der inneren Umgebungstemperatur des Schranks ausgelegt sein.<\/p>\n<h3 id=\"de-zwei-faelle\">1.1 Zwei Anwendungsf\u00e4lle: Inbetriebnahme versus Dauerbetrieb im Schrank<\/h3>\n<p>Es ist wichtig, zwei Szenarien zu trennen, die in der Beschaffung oft verwechselt werden. Das erste ist der <strong>Dauerbetrieb im Schrank<\/strong>: Das Netzteil ist auf DIN-Schiene montiert, l\u00e4uft 24\/7 und muss die thermische und Vibrationsumgebung des Schranks \u00fcberstehen. Das zweite ist <strong>Inbetriebnahme, Test und Validierung<\/strong>: Das Netzteil wird auf einem Tisch oder einem Inbetriebnahmewagen verwendet, um das PLC-Rack und die I\/O-Kreise zu versorgen, w\u00e4hrend der Schrank gebaut, verdrahtet und getestet wird.<\/p>\n<p>Das EA-PS 5080-20A ist ein programmierbares Tischnetzteil. Es passt zum zweiten Szenario. Es hat einen weiten 90\u2013264VAC-Eingang, einen pr\u00e4zisen 24VDC-Sollwert, geringe Restwelligkeit und Fernsteuerung zur Protokollierung\u2014alles n\u00fctzlich w\u00e4hrend der Inbetriebnahme. Es ist kein DIN-Schienen-Netzteil und nicht f\u00fcr die dauerhafte Schrankinstallation vorgesehen.<\/p>\n<h3 id=\"de-24v-stabilitaet\">1.2 Warum 24V-Stabilit\u00e4t f\u00fcr PLC- und I\/O-Kreise z\u00e4hlt<\/h3>\n<p>Typische 24VDC-Eing\u00e4nge von PLC akzeptieren einen Bereich von etwa 20,4V bis 28,8V. Wenn die Schiene w\u00e4hrend eines Lastsprungs oder eines Netz-Einbruchs unter 20V f\u00e4llt, kann die PLC zur\u00fccksetzen oder ein I\/O-Modul einen falschen Eingang melden. Wenn die Schiene zu hoch steigt, k\u00f6nnen Eingangsschutzschaltungen klemmen oder das Modul besch\u00e4digt werden.<\/p>\n<p>Stabilit\u00e4t hat zwei Komponenten: station\u00e4re Genauigkeit und Transientenantwort. Das EA-PS 5080-20A spezifiziert &lt;0,08% Spannungslastregelung, &lt;0,02% Netzregelung und &lt;1ms Lastregelungszeit, was die Lastspr\u00fcnge durch Relais, Sch\u00fctze und I\/O-Bank-Umschaltungen w\u00e4hrend der Inbetriebnahme abdeckt.<\/p>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-19260\" src=\"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/10\/HEA3590-EA-PS-5080-20A-1-1.png\" alt=\"EA-PS 5080-20A\" width=\"1024\" height=\"576\" \/><\/p>\n<p><a class=\"cta-primary\" href=\"https:\/\/www.shop-tps.com\/de\/shop\/category\/leistungsmodule-zum-einbau-dcdc-bidirectional-194\" target=\"_blank\" rel=\"noopener noreferrer nofollow\">TPS-Leistungsmodule erkunden \u2192<\/a><\/p>\n<\/section>\n<section id=\"de-elektrisch\">\n<h2>2. Elektrische Leistung des EA-PS 5080-20A f\u00fcr 24VDC-PLC-Lasten<\/h2>\n<p>Das EA-PS 5080-20A ist f\u00fcr Labor- und industrielle Testanwendungen spezifiziert. Seine elektrische Leistung ist f\u00fcr die PLC- und I\/O-Inbetriebnahme relevant, weil sie bestimmt, wie sauber und stabil die 24VDC-Schiene w\u00e4hrend der Schrankvalidierung ist.<\/p>\n<h3 id=\"de-eingang-pfc\">2.1 90\u2013264VAC-Eingang und aktive PFC<\/h3>\n<p>Der 90\u2013264VAC-Eingang deckt nominale 220VAC-, 230VAC- und 240VAC-Versorgungen sowie 110VAC und 120VAC ab, wo erforderlich. Die aktive PFC mit einem Leistungsfaktor &gt;0,99 reduziert die Eingangsstromoberschwingungen, die das Netzteil in die Verteilung des Inbetriebnahmebereichs zur\u00fcckspeist. Das z\u00e4hlt, wenn der Pr\u00fcfplatz einen Stromkreis mit empfindlichen Testger\u00e4ten teilt.<\/p>\n<h3 id=\"de-ausgang\">2.2 Ausgangsregelung, Restwelligkeit und Lastsprungverhalten<\/h3>\n<p>F\u00fcr eine 24VDC-PLC-Schiene sind die relevanten Spezifikationen:<\/p>\n<ul>\n<li><strong>Spannungsgenauigkeit &lt;0,2%<\/strong>: Der angezeigte Sollwert ist der gelieferte Sollwert, innerhalb der spezifizierten Toleranz.<\/li>\n<li><strong>Restwelligkeit &lt;80mV pp \/ &lt;10mV RMS<\/strong>: niedrig genug, dass das Netzteilsrauschen die PLC-Eingangsmessung w\u00e4hrend der Validierung nicht dominiert.<\/li>\n<li><strong>Lastregelung &lt;0,08% und Lastregelungszeit &lt;1ms<\/strong>: Die Schiene erholt sich schnell nach Relais- oder Sch\u00fctzumschaltungen.<\/li>\n<\/ul>\n<p>Diese Werte werden an den Netzteil klemmen gemessen. An den PLC-Klemmen sind Fernabtastung oder kurze, ausreichend dimensionierte Leitungen erforderlich, um sie zu erhalten; sonst erscheint der Leitungsabfall als zus\u00e4tzlicher Fehler.<\/p>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-19250\" src=\"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/10\/220VAC-to-24VDC-Power-Supply-Block-Diagram-PLC-2.jpg\" alt=\"220VAC to 24VDC Power Supply Block Diagram PLC\" width=\"1920\" height=\"1079\" \/><\/p>\n<\/section>\n<section id=\"de-integration\">\n<h2>3. Integration in Schaltschrankbau und Inbetriebnahme<\/h2>\n<p>Ein Tischnetzteil f\u00fcr die Inbetriebnahme zu verwenden, ist ein praktischer Weg, einen Schrank in Betrieb zu nehmen, bevor das endg\u00fcltige DIN-Schienen-Netzteil installiert ist, oder die 24VDC-Verteilung unabh\u00e4ngig vom endg\u00fcltigen Netzteil zu validieren.<\/p>\n<h3 id=\"de-verdrahtung\">3.1 Verdrahtung, Erdung und SELV-Grenzen<\/h3>\n<p>Schlie\u00dfen Sie das Netzteil \u00fcber einen RCD-gesch\u00fctzten Stromkreis und einen geeigneten Leistungsschutzschalter an das 220VAC-Netz an. Halten Sie die 220VAC-Eingangsverdrahtung von der 24VDC-Ausgangsverdrahtung getrennt. Verbinden Sie den Schutzleiter des Netzteils mit der PE-Schiene des Schranks. Der Ausgang ist SELV; verbinden Sie den 24VDC-Minuspol nicht mit dem Schutzleiter, es sei denn, das Erdungskonzept des Schranks verlangt es ausdr\u00fccklich.<\/p>\n<h3 id=\"de-schutz\">3.2 Schutzeinstellungen f\u00fcr PLC- und I\/O-Lasten<\/h3>\n<p>Stellen Sie den Ausgang auf 24,0V und konfigurieren Sie OVP, OCP und OPP, bevor Sie das PLC-Rack bestromen. Stellen Sie OVP knapp \u00fcber der maximalen Eingangsspannung der PLC und OCP knapp \u00fcber dem erwarteten Gesamtlaststrom ein, damit ein Verdrahtungsfehler eine kontrollierte Abschaltung ausl\u00f6st, statt die I\/O-Module zu besch\u00e4digen. Das EA-PS 5080-20A bietet einstellbare OVP, OCP, OPP und \u00dcbertemperaturschutz.<\/p>\n<h3 id=\"de-logging\">3.3 Fernsteuerung und Protokollierung w\u00e4hrend der Inbetriebnahme<\/h3>\n<p>Die USB-Schnittstelle und die LabView VIs \/ Windows-Steuerungssoftware erm\u00f6glichen die Protokollierung der 24VDC-Schiene w\u00e4hrend der Inbetriebnahme: Start, Lastspr\u00fcnge und die Reaktion auf Relaisumschaltungen. Dieses Protokoll wird Teil der Inbetriebnahmeaufzeichnung und hilft sp\u00e4ter bei der Diagnose intermittierender I\/O-Fehler. Die <a href=\"https:\/\/tps-elektronik.com\/fr\/category\/produkte\/\">TPS-Produktkategorie<\/a> und die <a href=\"https:\/\/tps-elektronik.com\/fr\/category\/blog-content\/\">TPS-Blog-Inhalte<\/a> bieten verwandten Anwendungskontext.<\/p>\n<\/section>\n<section id=\"de-wann-din\">\n<h2>4. Wann ein DIN-Schienen-Netzteil die richtige Wahl ist<\/h2>\n<p>Wenn die Anforderung ein dauerhaftes 220VAC-zu-24VDC-Netzteil im Steuerungsschrank ist, ist die richtige Komponente ein DIN-Schienen-Netzteil, das f\u00fcr Dauerbetrieb ausgelegt ist, mit verifizierter innerer Umgebungstemperatur, Derating-Kurve und den anwendbaren Sicherheits- und EMV-Normen. Ein programmierbares Tischnetzteil ist kein Ersatz f\u00fcr diese Installation.<\/p>\n<p>Typische Entscheidungspunkte:<\/p>\n<ul>\n<li><strong>Dauerhafte Schrankinstallation:<\/strong> DIN-Schienen-Netzteil, 24VDC-Ausgang, Dauerbetrieb, Derating bei Schrankumgebungstemperatur verifiziert.<\/li>\n<li><strong>Inbetriebnahme und Test:<\/strong> programmierbares Tischnetzteil, einstellbare 24VDC, geringe Restwelligkeit, Protokollierungsf\u00e4higkeit.<\/li>\n<li><strong>Schrankbau vor Ankunft des endg\u00fcltigen Netzteils:<\/strong> Tischnetzteil tempor\u00e4r verwendet, endg\u00fcltiges DIN-Schienen-Netzteil in der St\u00fcckliste des Schranks dokumentiert.<\/li>\n<\/ul>\n<p>F\u00fcr verwandte Leistungsprodukte siehe die <a href=\"https:\/\/www.shop-tps.com\/de\/shop\/tps-dm570t1512kif-27873?category=194\" target=\"_blank\" rel=\"noopener noreferrer nofollow\">TPS-DM570T1512KIF<\/a> und <a href=\"https:\/\/www.shop-tps.com\/de\/shop\/tps-dm570t1512kirf-27874?category=194\" target=\"_blank\" rel=\"noopener noreferrer nofollow\">TPS-DM570T1512KIRF<\/a> bidirektionalen DC-DC-Module.<\/p>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-19245\" src=\"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/10\/Stable-24VDC-Output-PLC-IO-Load-Step-Response-3.jpg\" alt=\"Stable 24VDC Output PLC IO Load Step Response\" width=\"1920\" height=\"1079\" \/><\/p>\n<\/section>\n<section id=\"de-spezifikationen\">\n<h2>5. Produktspezifikationen<\/h2>\n<table>\n<thead>\n<tr>\n<th>Parameter<\/th>\n<th>EA-PS 5080-20A<\/th>\n<th>Typisches DIN-Schienen-24V-Netzteil<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Eingang<\/td>\n<td>90\u2013264VAC, 45\u201365Hz<\/td>\n<td>85\u2013264VAC<\/td>\n<\/tr>\n<tr>\n<td>Ausgang<\/td>\n<td>0\u201380VDC \/ 0\u201320A \/ 640W, Auto-Ranging<\/td>\n<td>24VDC fest, 10\u201340A<\/td>\n<\/tr>\n<tr>\n<td>Montage<\/td>\n<td>Tisch \/ Desktop<\/td>\n<td>DIN-Schiene 35mm<\/td>\n<\/tr>\n<tr>\n<td>Restwelligkeit<\/td>\n<td>&lt;80mV pp \/ &lt;10mV RMS<\/td>\n<td>Typisch 100\u2013200mV pp<\/td>\n<\/tr>\n<tr>\n<td>Lastregelung<\/td>\n<td>&lt;0,08%<\/td>\n<td>0,5\u20131%<\/td>\n<\/tr>\n<tr>\n<td>Fernsteuerung<\/td>\n<td>USB, LabView, Windows-Software<\/td>\n<td>Meist keine<\/td>\n<\/tr>\n<tr>\n<td>Typische Anwendung<\/td>\n<td>Inbetriebnahme, Test, Validierung<\/td>\n<td>Dauerbetrieb im Schrank<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Der Vergleich zeigt, warum die beiden Produkte nicht austauschbar sind: Sie dienen unterschiedlichen Installations- und Betriebsanforderungen.<\/p>\n<\/section>\n<section id=\"de-rfq\">\n<h2>6. RFQ-Checkliste<\/h2>\n<p>Um Angebotserstellung und Bewertung f\u00fcr ein <strong>ac 220v power supply<\/strong>\u00a0in der PLC- und I\/O-Inbetriebnahme zu beschleunigen, geben Sie Folgendes an:<\/p>\n<ul>\n<li><strong>Anwendungsfall<\/strong>: Inbetriebnahme-\/Testplatz oder dauerhafte DIN-Schienen-Schrankinstallation<\/li>\n<li><strong>Eingang<\/strong>: Nominale Netzspannung, Toleranz und ob 110VAC-Betrieb erforderlich ist<\/li>\n<li><strong>Ausgang<\/strong>: 24VDC-Sollwert, Gesamtlaststrom und Spitzenstrom bei Relais-\/Sch\u00fctzumschaltung<\/li>\n<li><strong>Lastliste<\/strong>: PLC-CPU, I\/O-Module, Sensoren, Relais und alle 24VDC-Hilfslasten<\/li>\n<li><strong>Stabilit\u00e4tsanforderung<\/strong>: Zul\u00e4ssiges Spannungsfenster und Transienten-Erholzeit<\/li>\n<li><strong>Schutzeinstellungen<\/strong>: OVP-, OCP-, OPP-Schwellen f\u00fcr die angeschlossenen Lasten<\/li>\n<li><strong>Montage<\/strong>: Tisch, Inbetriebnahmewagen oder DIN-Schiene<\/li>\n<li><strong>Dokumentation<\/strong>: Datenblatt, Testbericht und Compliance-Dokumentation<\/li>\n<\/ul>\n<p>Die Angabe dieser Details reduziert Kl\u00e4rungszyklen. Das Engineering-Team von TPS kann Auswahl, Schutzeinstellung und Inbetriebnahme-Protokollierung als Teil des RFQ-Prozesses unterst\u00fctzen.<\/p>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-19240\" src=\"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/10\/Control-Cabinet-PSU-DIN-Rail-vs-Bench-Supply-4.jpg\" alt=\"Control Cabinet PSU DIN Rail vs Bench Supply\" width=\"1920\" height=\"1079\" \/><\/p>\n<p><a class=\"cta-primary\" href=\"https:\/\/www.shop-tps.com\/de\/shop\/category\/leistungsmodule-zum-einbau-dcdc-bidirectional-194\" target=\"_blank\" rel=\"noopener noreferrer nofollow\">Ihre 220VAC-zu-24VDC-RFQ einreichen \u2192<\/a><\/p>\n<\/section>\n<section id=\"de-faq\">\n<h2>7. FAQ<\/h2>\n<div>\n<h3>Kann das EA-PS 5080-20A dauerhaft in einem Steuerungsschrank installiert werden?<\/h3>\n<div>Es ist ein programmierbares Tisch-\/Desktop-Netzteil, kein DIN-Schienen-Netzteil. Es ist f\u00fcr Labor-, Test- und Inbetriebnahmeanwendungen vorgesehen. F\u00fcr die dauerhafte Schrankinstallation ist ein DIN-Schienen-Netzteil zu w\u00e4hlen, das f\u00fcr Dauerbetrieb bei der inneren Umgebungstemperatur des Schranks ausgelegt ist.<\/div>\n<\/div>\n<div>\n<h3>Deckt der 90\u2013264VAC-Eingang 220VAC-Netz ab?<\/h3>\n<div>Ja. 220VAC liegt innerhalb des 90\u2013264VAC-Eingangsbereichs. Dasselbe Netzteil deckt auch nominale 110VAC-, 120VAC-, 230VAC- und 240VAC-Versorgungen ab.<\/div>\n<\/div>\n<div>\n<h3>Wie stabil ist der 24VDC-Ausgang f\u00fcr PLC- und I\/O-Lasten?<\/h3>\n<div>Das Netzteil spezifiziert &lt;0,08% Spannungslastregelung, &lt;0,02% Netzregelung, &lt;1ms Lastregelungszeit und &lt;0,2% Spannungsgenauigkeit. Die Restwelligkeit betr\u00e4gt &lt;80mV pp und &lt;10mV RMS. An den PLC-Klemmen sind Fernabtastung oder kurze, ausreichend dimensionierte Leitungen erforderlich, um diese Werte zu erhalten.<\/div>\n<\/div>\n<div>\n<h3>Ist der Ausgang SELV?<\/h3>\n<div>Die Produktdaten geben SELV-Konformit\u00e4t an, und das Netzteil erf\u00fcllt die EMV-Anforderungen nach EN 55022 Class B. Pr\u00fcfen Sie die f\u00fcr Ihre Installation geltende Sicherheitsnorm und das Zertifikat im Datenblatt und mit TPS vor der Freigabe.<\/div>\n<\/div>\n<div>\n<h3>Kann ich die 24VDC-Schiene w\u00e4hrend der Inbetriebnahme protokollieren?<\/h3>\n<div>Ja. Die USB-Schnittstelle mit LabView VIs und Windows-Steuerungssoftware erm\u00f6glicht die Protokollierung von Spannung und Strom w\u00e4hrend Start, Lastspr\u00fcngen und Relaisumschaltungen. Das Protokoll kann der Inbetriebnahmeaufzeichnung beigef\u00fcgt werden.<\/div>\n<\/div>\n<\/section>\n<footer style=\"background: #2d5797; padding: 30px; border-radius: 14px; margin-top: 40px;\">\n<p style=\"color: #ffffff; font-size: 16px; line-height: 1.6; margin: 0;\"><strong>N\u00e4chster Schritt:<\/strong> F\u00fcr Inbetriebnahme und Test liefert das <strong>EA-PS 5080-20A<\/strong> eine stabile, restwelligkeitsarme 24VDC-Schiene aus 220VAC. F\u00fcr die dauerhafte Schrankinstallation spezifiziert TPS ein geeignetes DIN-Schienen-Netzteil. <a style=\"color: #ffffff; font-weight: 600; text-decoration: underline;\" href=\"https:\/\/www.shop-tps.com\/de\/shop\/category\/leistungsmodule-zum-einbau-dcdc-bidirectional-194\" target=\"_blank\" rel=\"noopener noreferrer nofollow\">TPS-Leistungsmodule ansehen \u2192<\/a><\/p>\n<\/footer><\/article>\n\n<style id=\"wpforms-css-vars-4336-block-2042b290-9805-4ca6-b0f5-922c7f329cfe\">\n\t\t\t\t#wpforms-4336.wpforms-block-2042b290-9805-4ca6-b0f5-922c7f329cfe {\n\t\t\t\t--wpforms-field-size-input-height: 43px;\n--wpforms-field-size-input-spacing: 15px;\n--wpforms-field-size-font-size: 16px;\n--wpforms-field-size-line-height: 19px;\n--wpforms-field-size-padding-h: 14px;\n--wpforms-field-size-checkbox-size: 16px;\n--wpforms-field-size-sublabel-spacing: 5px;\n--wpforms-field-size-icon-size: 1;\n--wpforms-label-size-font-size: 16px;\n--wpforms-label-size-line-height: 19px;\n--wpforms-label-size-sublabel-font-size: 14px;\n--wpforms-label-size-sublabel-line-height: 17px;\n--wpforms-button-size-font-size: 17px;\n--wpforms-button-size-height: 41px;\n--wpforms-button-size-padding-h: 15px;\n--wpforms-button-size-margin-top: 10px;\n\t\t\t}\n\t\t\t<\/style><div class=\"wpforms-container wpforms-container-full wpforms-block wpforms-block-2042b290-9805-4ca6-b0f5-922c7f329cfe wpforms-render-modern\" id=\"wpforms-4336\"><form id=\"wpforms-form-4336\" class=\"wpforms-validate wpforms-form wpforms-ajax-form\" data-formid=\"4336\" method=\"post\" enctype=\"multipart\/form-data\" action=\"\/fr\/wp-json\/wp\/v2\/posts\/19211\" data-token=\"c59120bf3b8d43092fe54750796d79be\" data-token-time=\"1794533742\"><noscript class=\"wpforms-error-noscript\">Veuillez activer JavaScript dans votre navigateur pour remplir ce formulaire.<\/noscript><div id=\"wpforms-error-noscript\" style=\"display: none;\">Veuillez activer JavaScript dans votre navigateur pour remplir ce formulaire.<\/div><div class=\"wpforms-field-container\"><div id=\"wpforms-4336-field_1-container\" class=\"wpforms-field wpforms-field-name wpforms-one-half wpforms-first\" data-field-id=\"1\"><label class=\"wpforms-field-label\" for=\"wpforms-4336-field_1\">Name <span class=\"wpforms-required-label\" aria-hidden=\"true\">*<\/span><\/label><input type=\"text\" id=\"wpforms-4336-field_1\" class=\"wpforms-field-large wpforms-field-required\" name=\"wpforms[fields][1]\" aria-errormessage=\"wpforms-4336-field_1-error\" required><\/div><div id=\"wpforms-4336-field_2-container\" class=\"wpforms-field wpforms-field-email\" data-field-id=\"2\"><label class=\"wpforms-field-label\" for=\"wpforms-4336-field_2\">E-Mail <span class=\"wpforms-required-label\" aria-hidden=\"true\">*<\/span><\/label><input type=\"email\" id=\"wpforms-4336-field_2\" class=\"wpforms-field-large wpforms-field-required\" name=\"wpforms[fields][2]\" spellcheck=\"false\" aria-errormessage=\"wpforms-4336-field_2-error\" required><\/div><div id=\"wpforms-4336-field_4-container\" class=\"wpforms-field wpforms-field-text\" data-field-id=\"4\"><label class=\"wpforms-field-label\" for=\"wpforms-4336-field_4\"> Firma <span class=\"wpforms-required-label\" aria-hidden=\"true\">*<\/span><\/label><input type=\"text\" id=\"wpforms-4336-field_4\" class=\"wpforms-field-large wpforms-field-required\" name=\"wpforms[fields][4]\" aria-errormessage=\"wpforms-4336-field_4-error\" required><\/div><div id=\"wpforms-4336-field_3-container\" class=\"wpforms-field wpforms-field-textarea\" data-field-id=\"3\"><label class=\"wpforms-field-label\" for=\"wpforms-4336-field_3\">Kurzbeschreibung<\/label><textarea id=\"wpforms-4336-field_3\" class=\"wpforms-field-medium\" name=\"wpforms[fields][3]\" aria-errormessage=\"wpforms-4336-field_3-error\" ><\/textarea><\/div>\t\t<div id=\"wpforms-4336-field_5-container\"\n\t\t\tclass=\"wpforms-field wpforms-field-text\"\n\t\t\tdata-field-type=\"text\"\n\t\t\tdata-field-id=\"5\"\n\t\t\t>\n\t\t\t<label class=\"wpforms-field-label\" for=\"wpforms-4336-field_5\" >Name E-Mail Kurzbeschreibung<\/label>\n\t\t\t<input type=\"text\" id=\"wpforms-4336-field_5\" class=\"wpforms-field-medium\" name=\"wpforms[fields][5]\" >\n\t\t<\/div>\n\t\t<div id=\"wpforms-4336-field_6-container\" class=\"wpforms-field wpforms-field-checkbox\" data-field-id=\"6\"><fieldset><legend class=\"wpforms-field-label wpforms-label-hide\" aria-hidden=\"false\">Checkboxes <span class=\"wpforms-required-label\" aria-hidden=\"true\">*<\/span><\/legend><ul id=\"wpforms-4336-field_6\" class=\"wpforms-field-required\"><li class=\"choice-1 depth-1\"><input type=\"checkbox\" id=\"wpforms-4336-field_6_1\" name=\"wpforms[fields][6][]\" value=\"Ich stimme der Verarbeitung meiner Angaben zur Angebotserstellung zu.\" aria-errormessage=\"wpforms-4336-field_6_1-error\" aria-describedby=\"wpforms-4336-field_6-description\" required ><label class=\"wpforms-field-label-inline\" for=\"wpforms-4336-field_6_1\">Ich stimme der Verarbeitung meiner Angaben zur Angebotserstellung zu.<\/label><\/li><\/ul><div id=\"wpforms-4336-field_6-description\" class=\"wpforms-field-description\">Hinweise siehe Datenschutz.<\/div><\/fieldset><\/div><script>\n\t\t\t\t( function() {\n\t\t\t\t\tconst style = document.createElement( 'style' );\n\t\t\t\t\tstyle.appendChild( document.createTextNode( '#wpforms-4336-field_5-container { position: absolute !important; overflow: hidden !important; display: inline !important; height: 1px !important; width: 1px !important; z-index: -1000 !important; padding: 0 !important; } #wpforms-4336-field_5-container input { visibility: hidden; } #wpforms-conversational-form-page #wpforms-4336-field_5-container label { counter-increment: none; }' ) );\n\t\t\t\t\tdocument.head.appendChild( style );\n\t\t\t\t\tdocument.currentScript?.remove();\n\t\t\t\t} )();\n\t\t\t<\/script><\/div><!-- .wpforms-field-container --><div class=\"wpforms-recaptcha-container wpforms-is-turnstile\" ><div class=\"wpforms-turnstile\" data-sitekey=\"0x4AAAAAAFUTE-Rr1O4nxKnU\" data-action=\"FormID-4336\"><\/div><input type=\"text\" name=\"g-recaptcha-hidden\" class=\"wpforms-recaptcha-hidden\" style=\"position:absolute!important;clip:rect(0,0,0,0)!important;height:1px!important;width:1px!important;border:0!important;overflow:hidden!important;padding:0!important;margin:0!important;\" data-rule-turnstile=\"1\"><\/div><div class=\"wpforms-submit-container\" ><input type=\"hidden\" name=\"wpforms[id]\" value=\"4336\"><input type=\"hidden\" name=\"wpforms[time_token]\" value=\"1794533742.20c517bf38132dfc08b2b74359aac8b054108ce1462c62bdd5751da54b67b259\"><input type=\"hidden\" name=\"page_title\" value=\"\"><input type=\"hidden\" name=\"page_url\" value=\"https:\/\/tps-elektronik.com\/fr\/wp-json\/wp\/v2\/posts\/19211\"><input type=\"hidden\" name=\"url_referer\" value=\"\"><button type=\"submit\" name=\"wpforms[submit]\" id=\"wpforms-submit-4336\" class=\"wpforms-submit\" data-alt-text=\"Senden...\" data-submit-text=\"Anfrage senden\" aria-live=\"assertive\" value=\"wpforms-submit\">Anfrage senden<\/button><img decoding=\"async\" src=\"https:\/\/tps-elektronik.com\/wp-content\/plugins\/wpforms-lite\/assets\/images\/submit-spin.svg\" class=\"wpforms-submit-spinner\" style=\"display: none;\" width=\"26\" height=\"26\" alt=\"Chargement en cours\"><\/div><\/form><\/div>  <!-- .wpforms-container -->","protected":false},"excerpt":{"rendered":"<p>F\u00fcr Systemintegratoren, Schaltschrankbauer und ingenieurgetriebene Beschaffungsteams ist die Umwandlung von 220VAC in 24VDC in einem industriellen Steuerungsschrank nicht nur die Auswahl eines Netzteils mit der richtigen Wattzahl. Es geht auch um Eingangsbereich, Ausgangsstabilit\u00e4t, Restwelligkeit, Schutzverhalten, SELV-Konformit\u00e4t und\u2014entscheidend\u2014darum, ob das gew\u00e4hlte Netzteil f\u00fcr den Dauerbetrieb im Schrank oder f\u00fcr Inbetriebnahme und Test ausgelegt ist. Das EA-PS\u2026 <a href=\"https:\/\/tps-elektronik.com\/fr\/how-to-convert-220vac-to-stable-24vdc-for-plc-and-i-o-circuits-in-industrial-control-cabinets-with-tps%ef%bc%9f\/\">Read More &raquo;<\/a><\/p>\n","protected":false},"author":9,"featured_media":19260,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[19],"tags":[],"class_list":["post-19211","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-produkte"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Wie l\u00e4sst sich 220 V AC mithilfe von TPS in eine stabile 24-V-Gleichspannung (24 V DC) f\u00fcr SPS- und E\/A-Stromkreise in industriellen Schaltschr\u00e4nken umwandeln? - TPS<\/title>\n<meta name=\"description\" content=\"AC 220v power supply in eine stabile 24 V DC-Spannungsversorgung f\u00fcr SPS- und E\/A-Stromkreise. Einsatz am Pr\u00fcfplatz sowie bei der Inbetriebnahme (in Verbindung mit einem TPS).\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/tps-elektronik.com\/fr\/how-to-convert-220vac-to-stable-24vdc-for-plc-and-i-o-circuits-in-industrial-control-cabinets-with-tps%ef%bc%9f\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Wie l\u00e4sst sich 220 V AC mithilfe von TPS in eine stabile 24-V-Gleichspannung (24 V DC) f\u00fcr SPS- und E\/A-Stromkreise in industriellen Schaltschr\u00e4nken umwandeln? - TPS\" \/>\n<meta property=\"og:description\" content=\"AC 220v power supply in eine stabile 24 V DC-Spannungsversorgung f\u00fcr SPS- und E\/A-Stromkreise. Einsatz am Pr\u00fcfplatz sowie bei der Inbetriebnahme (in Verbindung mit einem TPS).\" \/>\n<meta property=\"og:url\" content=\"https:\/\/tps-elektronik.com\/fr\/how-to-convert-220vac-to-stable-24vdc-for-plc-and-i-o-circuits-in-industrial-control-cabinets-with-tps%ef%bc%9f\/\" \/>\n<meta property=\"og:site_name\" content=\"TPS\" \/>\n<meta property=\"article:published_time\" content=\"2026-11-13T00:30:53+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/10\/HEA3590-EA-PS-5080-20A-1-1.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1024\" \/>\n\t<meta property=\"og:image:height\" content=\"576\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Tang Marcus\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u00c9crit par\" \/>\n\t<meta name=\"twitter:data1\" content=\"Tang Marcus\" \/>\n\t<meta name=\"twitter:label2\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data2\" content=\"7 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/fr\\\/how-to-convert-220vac-to-stable-24vdc-for-plc-and-i-o-circuits-in-industrial-control-cabinets-with-tps%ef%bc%9f\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/fr\\\/how-to-convert-220vac-to-stable-24vdc-for-plc-and-i-o-circuits-in-industrial-control-cabinets-with-tps%ef%bc%9f\\\/\"},\"author\":{\"name\":\"Tang Marcus\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/fr\\\/#\\\/schema\\\/person\\\/2c19fd053095d0c1ae253e8e62427b8c\"},\"headline\":\"Wie l\u00e4sst sich 220 V AC mithilfe von TPS in eine stabile 24-V-Gleichspannung (24 V DC) f\u00fcr SPS- und E\\\/A-Stromkreise in industriellen Schaltschr\u00e4nken umwandeln?\",\"datePublished\":\"2026-11-13T00:30:53+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/fr\\\/how-to-convert-220vac-to-stable-24vdc-for-plc-and-i-o-circuits-in-industrial-control-cabinets-with-tps%ef%bc%9f\\\/\"},\"wordCount\":1517,\"image\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/fr\\\/how-to-convert-220vac-to-stable-24vdc-for-plc-and-i-o-circuits-in-industrial-control-cabinets-with-tps%ef%bc%9f\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/tps-elektronik.com\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/HEA3590-EA-PS-5080-20A-1-1.png\",\"articleSection\":[\"Produkt\"],\"inLanguage\":\"fr-FR\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/fr\\\/how-to-convert-220vac-to-stable-24vdc-for-plc-and-i-o-circuits-in-industrial-control-cabinets-with-tps%ef%bc%9f\\\/\",\"url\":\"https:\\\/\\\/tps-elektronik.com\\\/fr\\\/how-to-convert-220vac-to-stable-24vdc-for-plc-and-i-o-circuits-in-industrial-control-cabinets-with-tps%ef%bc%9f\\\/\",\"name\":\"Wie l\u00e4sst sich 220 V AC mithilfe von TPS in eine stabile 24-V-Gleichspannung (24 V DC) f\u00fcr SPS- und E\\\/A-Stromkreise in industriellen Schaltschr\u00e4nken umwandeln? - TPS\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/fr\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/fr\\\/how-to-convert-220vac-to-stable-24vdc-for-plc-and-i-o-circuits-in-industrial-control-cabinets-with-tps%ef%bc%9f\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/fr\\\/how-to-convert-220vac-to-stable-24vdc-for-plc-and-i-o-circuits-in-industrial-control-cabinets-with-tps%ef%bc%9f\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/tps-elektronik.com\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/HEA3590-EA-PS-5080-20A-1-1.png\",\"datePublished\":\"2026-11-13T00:30:53+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/fr\\\/#\\\/schema\\\/person\\\/2c19fd053095d0c1ae253e8e62427b8c\"},\"description\":\"AC 220v power supply in eine stabile 24 V DC-Spannungsversorgung f\u00fcr SPS- und E\\\/A-Stromkreise. Einsatz am Pr\u00fcfplatz sowie bei der Inbetriebnahme (in Verbindung mit einem TPS).\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/fr\\\/how-to-convert-220vac-to-stable-24vdc-for-plc-and-i-o-circuits-in-industrial-control-cabinets-with-tps%ef%bc%9f\\\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/tps-elektronik.com\\\/fr\\\/how-to-convert-220vac-to-stable-24vdc-for-plc-and-i-o-circuits-in-industrial-control-cabinets-with-tps%ef%bc%9f\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/fr\\\/how-to-convert-220vac-to-stable-24vdc-for-plc-and-i-o-circuits-in-industrial-control-cabinets-with-tps%ef%bc%9f\\\/#primaryimage\",\"url\":\"https:\\\/\\\/tps-elektronik.com\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/HEA3590-EA-PS-5080-20A-1-1.png\",\"contentUrl\":\"https:\\\/\\\/tps-elektronik.com\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/HEA3590-EA-PS-5080-20A-1-1.png\",\"width\":1024,\"height\":576,\"caption\":\"EA-PS 5080-20A\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/fr\\\/how-to-convert-220vac-to-stable-24vdc-for-plc-and-i-o-circuits-in-industrial-control-cabinets-with-tps%ef%bc%9f\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Startseite\",\"item\":\"https:\\\/\\\/tps-elektronik.com\\\/fr\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Wie l\u00e4sst sich 220 V AC mithilfe von TPS in eine stabile 24-V-Gleichspannung (24 V DC) f\u00fcr SPS- und E\\\/A-Stromkreise in industriellen Schaltschr\u00e4nken umwandeln?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/fr\\\/#website\",\"url\":\"https:\\\/\\\/tps-elektronik.com\\\/fr\\\/\",\"name\":\"TPS\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/tps-elektronik.com\\\/fr\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/fr\\\/#\\\/schema\\\/person\\\/2c19fd053095d0c1ae253e8e62427b8c\",\"name\":\"Tang Marcus\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Wie l\u00e4sst sich 220 V AC mithilfe von TPS in eine stabile 24-V-Gleichspannung (24 V DC) f\u00fcr SPS- und E\/A-Stromkreise in industriellen Schaltschr\u00e4nken umwandeln? - TPS","description":"AC 220v power supply in eine stabile 24 V DC-Spannungsversorgung f\u00fcr SPS- und E\/A-Stromkreise. Einsatz am Pr\u00fcfplatz sowie bei der Inbetriebnahme (in Verbindung mit einem TPS).","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/tps-elektronik.com\/fr\/how-to-convert-220vac-to-stable-24vdc-for-plc-and-i-o-circuits-in-industrial-control-cabinets-with-tps%ef%bc%9f\/","og_locale":"fr_FR","og_type":"article","og_title":"Wie l\u00e4sst sich 220 V AC mithilfe von TPS in eine stabile 24-V-Gleichspannung (24 V DC) f\u00fcr SPS- und E\/A-Stromkreise in industriellen Schaltschr\u00e4nken umwandeln? - TPS","og_description":"AC 220v power supply in eine stabile 24 V DC-Spannungsversorgung f\u00fcr SPS- und E\/A-Stromkreise. Einsatz am Pr\u00fcfplatz sowie bei der Inbetriebnahme (in Verbindung mit einem TPS).","og_url":"https:\/\/tps-elektronik.com\/fr\/how-to-convert-220vac-to-stable-24vdc-for-plc-and-i-o-circuits-in-industrial-control-cabinets-with-tps%ef%bc%9f\/","og_site_name":"TPS","article_published_time":"2026-11-13T00:30:53+00:00","og_image":[{"width":1024,"height":576,"url":"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/10\/HEA3590-EA-PS-5080-20A-1-1.png","type":"image\/png"}],"author":"Tang Marcus","twitter_card":"summary_large_image","twitter_misc":{"\u00c9crit par":"Tang Marcus","Dur\u00e9e de lecture estim\u00e9e":"7 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/tps-elektronik.com\/fr\/how-to-convert-220vac-to-stable-24vdc-for-plc-and-i-o-circuits-in-industrial-control-cabinets-with-tps%ef%bc%9f\/#article","isPartOf":{"@id":"https:\/\/tps-elektronik.com\/fr\/how-to-convert-220vac-to-stable-24vdc-for-plc-and-i-o-circuits-in-industrial-control-cabinets-with-tps%ef%bc%9f\/"},"author":{"name":"Tang Marcus","@id":"https:\/\/tps-elektronik.com\/fr\/#\/schema\/person\/2c19fd053095d0c1ae253e8e62427b8c"},"headline":"Wie l\u00e4sst sich 220 V AC mithilfe von TPS in eine stabile 24-V-Gleichspannung (24 V DC) f\u00fcr SPS- und E\/A-Stromkreise in industriellen Schaltschr\u00e4nken umwandeln?","datePublished":"2026-11-13T00:30:53+00:00","mainEntityOfPage":{"@id":"https:\/\/tps-elektronik.com\/fr\/how-to-convert-220vac-to-stable-24vdc-for-plc-and-i-o-circuits-in-industrial-control-cabinets-with-tps%ef%bc%9f\/"},"wordCount":1517,"image":{"@id":"https:\/\/tps-elektronik.com\/fr\/how-to-convert-220vac-to-stable-24vdc-for-plc-and-i-o-circuits-in-industrial-control-cabinets-with-tps%ef%bc%9f\/#primaryimage"},"thumbnailUrl":"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/10\/HEA3590-EA-PS-5080-20A-1-1.png","articleSection":["Produkt"],"inLanguage":"fr-FR"},{"@type":"WebPage","@id":"https:\/\/tps-elektronik.com\/fr\/how-to-convert-220vac-to-stable-24vdc-for-plc-and-i-o-circuits-in-industrial-control-cabinets-with-tps%ef%bc%9f\/","url":"https:\/\/tps-elektronik.com\/fr\/how-to-convert-220vac-to-stable-24vdc-for-plc-and-i-o-circuits-in-industrial-control-cabinets-with-tps%ef%bc%9f\/","name":"Wie l\u00e4sst sich 220 V AC mithilfe von TPS in eine stabile 24-V-Gleichspannung (24 V DC) f\u00fcr SPS- und E\/A-Stromkreise in industriellen Schaltschr\u00e4nken umwandeln? - TPS","isPartOf":{"@id":"https:\/\/tps-elektronik.com\/fr\/#website"},"primaryImageOfPage":{"@id":"https:\/\/tps-elektronik.com\/fr\/how-to-convert-220vac-to-stable-24vdc-for-plc-and-i-o-circuits-in-industrial-control-cabinets-with-tps%ef%bc%9f\/#primaryimage"},"image":{"@id":"https:\/\/tps-elektronik.com\/fr\/how-to-convert-220vac-to-stable-24vdc-for-plc-and-i-o-circuits-in-industrial-control-cabinets-with-tps%ef%bc%9f\/#primaryimage"},"thumbnailUrl":"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/10\/HEA3590-EA-PS-5080-20A-1-1.png","datePublished":"2026-11-13T00:30:53+00:00","author":{"@id":"https:\/\/tps-elektronik.com\/fr\/#\/schema\/person\/2c19fd053095d0c1ae253e8e62427b8c"},"description":"AC 220v power supply in eine stabile 24 V DC-Spannungsversorgung f\u00fcr SPS- und E\/A-Stromkreise. Einsatz am Pr\u00fcfplatz sowie bei der Inbetriebnahme (in Verbindung mit einem TPS).","breadcrumb":{"@id":"https:\/\/tps-elektronik.com\/fr\/how-to-convert-220vac-to-stable-24vdc-for-plc-and-i-o-circuits-in-industrial-control-cabinets-with-tps%ef%bc%9f\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/tps-elektronik.com\/fr\/how-to-convert-220vac-to-stable-24vdc-for-plc-and-i-o-circuits-in-industrial-control-cabinets-with-tps%ef%bc%9f\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/tps-elektronik.com\/fr\/how-to-convert-220vac-to-stable-24vdc-for-plc-and-i-o-circuits-in-industrial-control-cabinets-with-tps%ef%bc%9f\/#primaryimage","url":"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/10\/HEA3590-EA-PS-5080-20A-1-1.png","contentUrl":"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/10\/HEA3590-EA-PS-5080-20A-1-1.png","width":1024,"height":576,"caption":"EA-PS 5080-20A"},{"@type":"BreadcrumbList","@id":"https:\/\/tps-elektronik.com\/fr\/how-to-convert-220vac-to-stable-24vdc-for-plc-and-i-o-circuits-in-industrial-control-cabinets-with-tps%ef%bc%9f\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Startseite","item":"https:\/\/tps-elektronik.com\/fr\/"},{"@type":"ListItem","position":2,"name":"Wie l\u00e4sst sich 220 V AC mithilfe von TPS in eine stabile 24-V-Gleichspannung (24 V DC) f\u00fcr SPS- und E\/A-Stromkreise in industriellen Schaltschr\u00e4nken umwandeln?"}]},{"@type":"WebSite","@id":"https:\/\/tps-elektronik.com\/fr\/#website","url":"https:\/\/tps-elektronik.com\/fr\/","name":"TPS","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/tps-elektronik.com\/fr\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Person","@id":"https:\/\/tps-elektronik.com\/fr\/#\/schema\/person\/2c19fd053095d0c1ae253e8e62427b8c","name":"Tang Marcus"}]}},"_links":{"self":[{"href":"https:\/\/tps-elektronik.com\/fr\/wp-json\/wp\/v2\/posts\/19211","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/tps-elektronik.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/tps-elektronik.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/tps-elektronik.com\/fr\/wp-json\/wp\/v2\/users\/9"}],"replies":[{"embeddable":true,"href":"https:\/\/tps-elektronik.com\/fr\/wp-json\/wp\/v2\/comments?post=19211"}],"version-history":[{"count":3,"href":"https:\/\/tps-elektronik.com\/fr\/wp-json\/wp\/v2\/posts\/19211\/revisions"}],"predecessor-version":[{"id":19263,"href":"https:\/\/tps-elektronik.com\/fr\/wp-json\/wp\/v2\/posts\/19211\/revisions\/19263"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/tps-elektronik.com\/fr\/wp-json\/wp\/v2\/media\/19260"}],"wp:attachment":[{"href":"https:\/\/tps-elektronik.com\/fr\/wp-json\/wp\/v2\/media?parent=19211"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/tps-elektronik.com\/fr\/wp-json\/wp\/v2\/categories?post=19211"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/tps-elektronik.com\/fr\/wp-json\/wp\/v2\/tags?post=19211"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}