{"id":16460,"date":"2026-09-07T09:00:00","date_gmt":"2026-09-07T07:00:00","guid":{"rendered":"https:\/\/tps-elektronik.com\/?p=16460"},"modified":"2026-08-20T07:23:33","modified_gmt":"2026-08-20T05:23:33","slug":"how-to-equip-general-purpose-rf-test-benches-with-high-quality-phase-stable-coaxial-test-cables-and-adapters-from-tps","status":"publish","type":"post","link":"https:\/\/tps-elektronik.com\/fr\/how-to-equip-general-purpose-rf-test-benches-with-high-quality-phase-stable-coaxial-test-cables-and-adapters-from-tps\/","title":{"rendered":"Wie stattet man universelle HF-Testpl\u00e4tze mit hochwertigen phasenangepassten Koaxial-Testkabeln und Adaptern von TPS aus?"},"content":{"rendered":"<article class=\"blog-post\" lang=\"de\"><header>\n<p>F\u00fcr Systemintegratoren, Pr\u00fcfingenieure und Einkaufsteams, die Allzweck-HF-Pr\u00fcfpl\u00e4tze einrichten, ist die Qualit\u00e4t der Koaxial-Pr\u00fcfkabel kein Nebenaspekt \u2013 sie ist der Unterschied zwischen zuverl\u00e4ssigen, reproduzierbaren Messungen und stundenlanger Suche nach Phantom-Signalen. Ein Pr\u00fcfkabel mit schlechter Phasenstabilit\u00e4t, hohem VSWR oder inkonsistenter Einf\u00fcgungsd\u00e4mpfung kann aus einer einfachen Verifikation einen m\u00fchsamen Debugging-Albtraum machen.<\/p>\n<p>Die <strong>coaxial cable assembly<\/strong>\u00a0von TPS Elektronik liefern hochwertige phasenstabile Pr\u00fcfkabel und Adapter f\u00fcr Allzweck-HF-Pr\u00fcfpl\u00e4tze \u2013 von SMA- und BNC- bis hin zu N-Typ-Schnittstellen, mit Pr\u00e4zisionskonfektionierung und dokumentierter Pr\u00fcfung, die Messsicherheit von der Prototypenvalidierung bis zum Produktionstest gew\u00e4hrleistet.<\/p>\n<p><a class=\"cta-primary\" href=\"https:\/\/tps-elektronik.com\/services\/ems\/kabelkonfektion\/\">Angebot f\u00fcr Koaxialkabel-Konfektion anfordern \u2192<\/a><\/p>\n<\/header><nav class=\"toc\" aria-label=\"Inhaltsverzeichnis\">\n<h2 id=\"toc-de\">Inhaltsverzeichnis<\/h2>\n<ol>\n<li><a href=\"#de-hf-pruefplatz\">Die HF-Pr\u00fcfplatz-Herausforderung: Warum Kabelqualit\u00e4t entscheidend ist<\/a><\/li>\n<li><a href=\"#de-phasenstabilitaet\">Phasenstabilit\u00e4t: Der Schl\u00fcssel zu reproduzierbaren HF-Messungen<\/a><\/li>\n<li><a href=\"#de-steckverbinder\">Steckverbinder-Optionen: SMA, BNC und N-Typ f\u00fcr allgemeine Pr\u00fcfungen<\/a><\/li>\n<li><a href=\"#de-tps-faehigkeiten\">TPS-Coaxial Cable Assembly f\u00fcr HF-Pr\u00fcfpl\u00e4tze<\/a><\/li>\n<li><a href=\"#de-qualitaet-pruefung\">Qualit\u00e4t und Pr\u00fcfung: Messsicherheit gew\u00e4hrleisten<\/a><\/li>\n<li><a href=\"#de-faq\">FAQ<\/a><\/li>\n<\/ol>\n<\/nav>\n<section id=\"de-hf-pruefplatz\">\n<h2>1. Die HF-Pr\u00fcfplatz-Herausforderung: Warum Kabelqualit\u00e4t entscheidend ist<\/h2>\n<p>Allzweck-HF-Pr\u00fcfpl\u00e4tze sind die Arbeitspferde der Elektronikentwicklung und Produktionspr\u00fcfung. Sie unterst\u00fctzen ein breites Anwendungsspektrum \u2013 von der Validierung von Funkmodulen und der Charakterisierung von Verst\u00e4rkern bis hin zum Testen von Filtern, Antennen und kompletten HF-Subsystemen. Im Zentrum jedes Pr\u00fcfplatzes stehen die Koaxialkabel, die das Pr\u00fcfling (DUT) mit der Pr\u00fcfausr\u00fcstung verbinden.<\/p>\n<p>F\u00fcr Pr\u00fcfingenieure und Systemintegratoren hat die Wahl der Pr\u00fcfkabel direkte Auswirkungen auf die Messgenauigkeit und Reproduzierbarkeit. Minderwertige Kabel k\u00f6nnen Fehler verursachen, die die wahre DUT-Leistung verschleiern und zu Folgendem f\u00fchren:<\/p>\n<ul>\n<li><strong>Inkonsistente Messungen:<\/strong> Kabel mit hoher Einf\u00fcgungsd\u00e4mpfung oder schlechtem VSWR d\u00e4mpfen Signale und erzeugen Reflexionen, die Messungen verzerren<\/li>\n<li><strong>Verschwendete Debugging-Zeit:<\/strong> Wenn Ingenieure ihrem Pr\u00fcfaufbau nicht vertrauen k\u00f6nnen, verschwenden sie Stunden mit der Suche nach Phantomproblemen, die sich als kabelbedingt herausstellen<\/li>\n<li><strong>Probleme mit der Produktionsausbeute:<\/strong> Grenzwertige Kabel im Produktionstest k\u00f6nnen gute Einheiten verwerfen oder schlechte Einheiten durchlassen, was Qualit\u00e4t und Kosten beeintr\u00e4chtigt<\/li>\n<li><strong>Kalibrierungsdrift:<\/strong> Kabel, die ihre Phase oder D\u00e4mpfung bei Bewegung \u00e4ndern, erfordern h\u00e4ufige Nachkalibrierung<\/li>\n<\/ul>\n<p>Die L\u00f6sung besteht darin, den Pr\u00fcfplatz mit <strong>hochwertigen phasenstabilen Koaxial-Pr\u00fcfkabeln<\/strong> auszustatten, die \u00fcber Zeit, Temperatur und mechanische Biegung hinweg konstante elektrische Eigenschaften beibehalten. Die <strong>coaxial cable assembly<\/strong>\u00a0von TPS Elektronik liefern genau das \u2013 pr\u00e4zisionskonfektionierte Kabel mit dokumentierter Leistung, denen Ingenieure vertrauen k\u00f6nnen.<\/p>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-16602\" src=\"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/08\/Phase-Stable-Coaxial-Test-Cables-on-RF-Test-Bench-1-1.jpg\" alt=\"Phase Stable Coaxial Test Cables on RF Test Bench\n\n\" width=\"1920\" height=\"1079\" \/><\/p>\n<p><a class=\"cta-primary\" href=\"https:\/\/tps-elektronik.com\/services\/ems\/kabelkonfektion\/\">TPS-coaxial cable assembly entdecken \u2192<\/a><\/p>\n<\/section>\n<section id=\"de-phasenstabilitaet\">\n<h2>2. Phasenstabilit\u00e4t: Der Schl\u00fcssel zu reproduzierbaren HF-Messungen<\/h2>\n<p>Die Phasenstabilit\u00e4t ist der wichtigste Leistungsparameter f\u00fcr HF-Pr\u00fcfkabel auf Allzweck-Pr\u00fcfpl\u00e4tzen. Wenn ein Kabel gebogen wird \u2013 was beim Pr\u00fcfaufbau, bei Verbindungen und bei Einstellungen unvermeidlich ist \u2013 \u00e4ndert sich seine elektrische L\u00e4nge geringf\u00fcgig. Diese \u00c4nderung der elektrischen L\u00e4nge f\u00fchrt zu einer Phasenverschiebung bei der Messfrequenz.<\/p>\n<p>Bei Vektornetzwerkanalysator-Messungen (VNA) ist die Phasenstabilit\u00e4t besonders entscheidend. Ein VNA misst sowohl Amplitude als auch Phase, um die S-Parameter eines Pr\u00fcflings zu charakterisieren. Wenn die Pr\u00fcfkabel bei Biegung ihre Phase \u00e4ndern, kann der Messfehler erheblich sein \u2013 insbesondere bei h\u00f6heren Frequenzen, wo ein kleiner Phasenfehler zu einer gro\u00dfen Messunsicherheit f\u00fchrt.<\/p>\n<p>Phasenstabile Pr\u00fcfkabel minimieren diesen Effekt durch eine spezielle Konstruktion:<\/p>\n<ul>\n<li><strong>Massives PTFE-Dielektrikum:<\/strong> Bietet stabile elektrische Eigenschaften \u00fcber Temperatur und Biegung<\/li>\n<li><strong>Verlustarmer Innenleiter:<\/strong> Silber-plattiertes Kupfer oder kupfer-plattierter Stahl reduziert die D\u00e4mpfung<\/li>\n<li><strong>SPC-Bandgeflecht-Abschirmung:<\/strong> Beh\u00e4lt konstante Impedanz bei Biegung bei<\/li>\n<li><strong>Pr\u00e4zisions-Steckverbinder-Konfektionierung:<\/strong> Gew\u00e4hrleistet konstante Impedanz an der Schnittstelle<\/li>\n<\/ul>\n<p>Typische phasenstabile Pr\u00fcfkabel halten die Phasenabweichung innerhalb von <strong>\u00b13\u00b0 bis 18 GHz<\/strong> und <strong>\u00b13\u00b0 bis 27 GHz<\/strong> bei Biegung. Im Gegensatz dazu k\u00f6nnen Standardkabel bei gleicher Biegung eine Phasendrift von 10\u00b0 oder mehr aufweisen \u2013 genug, um kritische Messungen zu verf\u00e4lschen.<\/p>\n<p>F\u00fcr <strong>Labor-Koaxialkabel<\/strong> bietet TPS Elektronik phasenstabile Pr\u00fcfkabel f\u00fcr den t\u00e4glichen Einsatz am Pr\u00fcfplatz mit Leistungsvalidierung gem\u00e4\u00df IEC 61196-1-111 f\u00fcr Phasenstabilit\u00e4t bei Biegung und Torsion.<\/p>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-16597\" src=\"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/08\/Phase-Stable-vs-Standard-Coaxial-Cable-Performance-Comparison-2-1.jpg\" alt=\"Phase Stable vs Standard Coaxial Cable Performance Comparison\" width=\"1920\" height=\"1079\" \/><\/p>\n<\/section>\n<section id=\"de-steckverbinder\">\n<h2>3. Steckverbinder-Optionen: SMA, BNC und N-Typ f\u00fcr allgemeine Pr\u00fcfungen<\/h2>\n<p>Ein Allzweck-HF-Pr\u00fcfplatz muss eine Vielzahl von Pr\u00fcflingen mit unterschiedlichen Steckverbinderschnittstellen aufnehmen k\u00f6nnen. Die <strong>coaxial cable assembly<\/strong>\u00a0von TPS Elektronik unterst\u00fctzen die drei g\u00e4ngigsten Steckverbinderfamilien f\u00fcr Pr\u00fcfplatzanwendungen: <strong>SMA, BNC und N-Typ<\/strong> sowie Adapter zur Verbindung zwischen ihnen.<\/p>\n<p><strong>SMA-Steckverbinder (SubMiniature version A):<\/strong> SMA-Steckverbinder sind die Arbeitspferde der Hochfrequenz-Pr\u00fcfplatztechnik und bieten hervorragende elektrische Eigenschaften bis zu 18 GHz (oder 26,5 GHz mit Pr\u00e4zisionsversionen). Die Gewindeschnittstelle bietet \u00fcberlegene mechanische Stabilit\u00e4t und zuverl\u00e4ssige Verbindungen, die h\u00e4ufige Steckzyklen \u00fcberstehen. \u00dcbliche Konfigurationen umfassen SMA-Stecker-zu-SMA-Stecker-Kabelbaugruppen sowie SMA-zu-BNC-Adapter f\u00fcr gemischte Schnittstellenanforderungen.<\/p>\n<p><strong>BNC-Steckverbinder (Bayonet Neill\u2013Concelman):<\/strong> BNC-Steckverbinder sind Standard f\u00fcr HF-Anwendungen bis zu 4 GHz und verf\u00fcgen \u00fcber einen Bajonett-Verschlussmechanismus f\u00fcr schnelle Verbindung und zuverl\u00e4ssigen mechanischen Halt. Sie werden h\u00e4ufig f\u00fcr Videosignale, allgemeine HF-Messungen und Pr\u00fcfger\u00e4teverbindungen verwendet. TPS fertigt BNC-Baugruppen mit Pr\u00e4zisions-Crimp- und L\u00f6ttechniken in 75-Ohm- und 50-Ohm-Varianten.<\/p>\n<p><strong>N-Typ-Steckverbinder:<\/strong> N-Typ-Steckverbinder bieten robuste, wetterfeste Verbindungen f\u00fcr Anwendungen bis zu 11 GHz und dar\u00fcber hinaus. Die Gewindeschnittstelle und die gr\u00f6\u00dfere Bauform machen sie ideal f\u00fcr Anwendungen mit h\u00f6herer Leistung und Umgebungen, die Haltbarkeit erfordern. TPS bietet N-Typ-Kabelbaugruppen f\u00fcr Pr\u00fcfpl\u00e4tze an, die h\u00f6here Leistungspegel oder anspruchsvollere mechanische Bedingungen bew\u00e4ltigen m\u00fcssen.<\/p>\n<p>F\u00fcr <strong>HF-Adapter-Kabelbaugruppen<\/strong> kann TPS kundenspezifische Adapterkabel liefern, die verschiedene Steckverbindertypen verbinden \u2013 SMA zu N-Typ, BNC zu SMA und andere Kombinationen \u2013 sodass ein einziger Pr\u00fcfplatz verschiedene Pr\u00fcflinge ohne mehrere spezielle Kabel aufnehmen kann.<\/p>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-16592\" src=\"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/08\/TPS-RF-Coaxial-Cable-Assembly-with-SMA-Connectors-3-1.jpg\" alt=\"TPS RF Coaxial Cable Assembly with SMA Connectors\n\n\" width=\"1920\" height=\"1079\" \/><\/p>\n<\/section>\n<section id=\"de-tps-faehigkeiten\">\n<h2>4. TPS-Coaxial cable assembly f\u00fcr HF-Pr\u00fcfpl\u00e4tze<\/h2>\n<p>Die <strong>coaxial cable assembly<\/strong> von TPS Elektronik f\u00fcr Allzweck-HF-Pr\u00fcfpl\u00e4tze kombinieren Pr\u00e4zisionsfertigung, umfassende Pr\u00fcfung und Integration in die \u00fcbergeordneten EMS-F\u00e4higkeiten.<\/p>\n<p><strong>Konstruktions- und Designunterst\u00fctzung:<\/strong><\/p>\n<ul>\n<li>Beratung zur Steckverbinderauswahl basierend auf Frequenzbereich, Leistungspegel und mechanischen Anforderungen<\/li>\n<li>Kabeltyp-Auswahl f\u00fcr Phasenstabilit\u00e4t, niedrige D\u00e4mpfung oder Flexibilit\u00e4t je nach Bedarf<\/li>\n<li>L\u00e4ngenoptimierung zur Minimierung der D\u00e4mpfung bei gleichzeitiger Beibehaltung der Pr\u00fcfplatzflexibilit\u00e4t<\/li>\n<li>Kundenspezifische Adapterkonfigurationen f\u00fcr Pr\u00fcflinge mit gemischten Schnittstellen<\/li>\n<\/ul>\n<p><strong>Fertigungskapazit\u00e4ten:<\/strong><\/p>\n<ul>\n<li><strong>Pr\u00e4zisionskonfektionierung:<\/strong> Crimpen und L\u00f6ten von SMA-, BNC- und N-Typ-Steckverbindern mit strenger Prozesskontrolle<\/li>\n<li><strong>Phasenstabile Kabelkonstruktion:<\/strong> SPC-Bandgeflecht und Dreifachschirmung f\u00fcr stabile Leistung bei Biegung<\/li>\n<li><strong>HF-Adapterkabel:<\/strong> SMA zu SMA, SMA zu N-Typ, BNC zu SMA und andere Konfigurationen<\/li>\n<li><strong>Kundenspezifische L\u00e4ngen:<\/strong> Von kurzen Jumper-Kabeln bis zu l\u00e4ngeren Pr\u00fcfplatzleitungen<\/li>\n<li><strong>Beschriftung und Dokumentation:<\/strong> Klare Kennzeichnung f\u00fcr Pr\u00fcfplatzorganisation und R\u00fcckverfolgbarkeit<\/li>\n<\/ul>\n<p><strong>Integration in EMS:<\/strong><\/p>\n<p>Im Gegensatz zur Beschaffung von Kabeln von einer reinen Kabelwerkstatt liefert TPS Kabelbaugruppen, die f\u00fcr die Integration in Ihren \u00fcbergeordneten elektronischen Montageworkflow validiert sind. F\u00fcr <strong>Pr\u00fcfplatz-HF-Koaxialkabel<\/strong> in Produktionstestumgebungen stellt diese Integration sicher, dass Pr\u00fcfkabel mit Pr\u00fcfvorrichtungen, Pr\u00fcfling-Schnittstellen und Systemintegrationsanforderungen koordiniert sind \u2013 was das Risiko von \u00dcberraschungen in letzter Minute reduziert.<\/p>\n<p><a class=\"cta-primary\" href=\"https:\/\/tps-elektronik.com\/services\/ems\/kabelkonfektion\/\">Angebot f\u00fcr Koaxialkabel-Konfektion anfordern \u2192<\/a><\/p>\n<\/section>\n<section id=\"de-qualitaet-pruefung\">\n<h2>5. Qualit\u00e4t und Pr\u00fcfung: Messsicherheit gew\u00e4hrleisten<\/h2>\n<p>Bei HF-Pr\u00fcfplatzanwendungen ist die Qualit\u00e4tssicherung kein letzter Schritt \u2013 sie ist im gesamten Fertigungsprozess verankert. Eine Kabelbaugruppe, die die Sichtpr\u00fcfung besteht, aber die elektrische Pr\u00fcfung nicht besteht, kann Messungen dennoch beeintr\u00e4chtigen.<\/p>\n<p>Der Qualit\u00e4tsprozess von TPS Elektronik f\u00fcr <strong>HF-Pr\u00fcfkabelbaugruppen<\/strong> umfasst:<\/p>\n<ul>\n<li><strong>Impedanzverifikation:<\/strong> Sicherstellung der 50-Ohm-charakteristischen Impedanz f\u00fcr korrekte Anpassung<\/li>\n<li><strong>Einf\u00fcgungsd\u00e4mpfungspr\u00fcfung:<\/strong> Verifikation, dass die D\u00e4mpfung \u00fcber den Betriebsfrequenzbereich der Spezifikation entspricht<\/li>\n<li><strong>VSWR-Pr\u00fcfung:<\/strong> Sicherstellung, dass die R\u00fcckflussd\u00e4mpfung den spezifizierten Grenzwerten f\u00fcr minimale Signalreflexion entspricht<\/li>\n<li><strong>Validierung der Phasenstabilit\u00e4t:<\/strong> Pr\u00fcfung gem\u00e4\u00df IEC 61196-1-111-Methoden f\u00fcr Phasenstabilit\u00e4t bei Biegung und Torsion<\/li>\n<li><strong>Sichtpr\u00fcfung:<\/strong> Kontrolle der Steckverbinder-Konfektionierung, Zugentlastung und Schirmungsintegrit\u00e4t<\/li>\n<li><strong>Dokumentation:<\/strong> Bereitstellung von Pr\u00fcfberichten f\u00fcr Qualit\u00e4tsaufzeichnungen und Audits<\/li>\n<\/ul>\n<p>TPS bezieht sich auf die <strong>IEC-61169<\/strong>-Normenreihe f\u00fcr Koaxialsteckverbinderleistung und <strong>IEC 61196-1-111<\/strong> f\u00fcr Phasenstabilit\u00e4ts-Pr\u00fcfverfahren. Dieses Bekenntnis zu anerkannten Normen stellt sicher, dass TPS-Kabelbaugruppen die Leistungserwartungen anspruchsvoller HF-Pr\u00fcfanwendungen erf\u00fcllen.<\/p>\n<p>F\u00fcr <strong>Pr\u00e4zisions-Koaxial-Pr\u00fcfleitungen<\/strong> bietet die Kombination aus Pr\u00e4zisionskonfektionierung, dokumentierter Pr\u00fcfung und r\u00fcckverfolgbaren Qualit\u00e4tsaufzeichnungen das Vertrauen, das Ingenieure ben\u00f6tigen, um ihren Messungen zu vertrauen \u2013 ob in der F&amp;E-Charakterisierung oder im Produktionstest.<\/p>\n<p><a class=\"cta-primary\" href=\"https:\/\/tps-elektronik.com\/services\/ems\/kabelkonfektion\/\">Angebot f\u00fcr HF-Pr\u00fcfkabelbaugruppe anfordern \u2192<\/a><\/p>\n<\/section>\n<section id=\"de-faq\">\n<h2>6. FAQ<\/h2>\n<div>\n<div>\n<h3>Was ist ein phasenstabiles Koaxialkabel und warum ist es f\u00fcr HF-Pr\u00fcfpl\u00e4tze wichtig?<\/h3>\n<div>\n<div>Ein phasenstabiles Koaxialkabel beh\u00e4lt bei Biegung oder Temperatur\u00e4nderungen eine konstante elektrische L\u00e4nge (und damit Phasenantwort). Dies ist f\u00fcr HF-Pr\u00fcfpl\u00e4tze entscheidend, da Kabelbewegungen w\u00e4hrend des Aufbaus und der Messung sonst Phasenfehler verursachen w\u00fcrden, die Messergebnisse verf\u00e4lschen \u2013 insbesondere bei Vektornetzwerkanalysator-Messungen, bei denen die Phasengenauigkeit entscheidend ist.<\/div>\n<\/div>\n<\/div>\n<div>\n<h3>Welche Steckverbindertypen bietet TPS f\u00fcr HF-Pr\u00fcfkabelbaugruppen an?<\/h3>\n<div>\n<div>TPS bietet SMA-, BNC- und N-Typ-Steckverbinder f\u00fcr HF-Pr\u00fcfkabelbaugruppen sowie Adapter zur Verbindung zwischen ihnen. SMA wird f\u00fcr Hochfrequenzanwendungen bis 18 GHz verwendet, BNC f\u00fcr allgemeine HF-Anwendungen bis 4 GHz und N-Typ f\u00fcr robuste, h\u00f6herleistungsf\u00e4hige Verbindungen.<\/div>\n<\/div>\n<\/div>\n<div>\n<h3>Wie hoch ist die typische Phasenstabilit\u00e4t eines hochwertigen Pr\u00fcfkabels?<\/h3>\n<div>\n<div>Hochwertige phasenstabile Pr\u00fcfkabel halten die Phasenabweichung typischerweise innerhalb von \u00b13\u00b0 bis 18 GHz und \u00b13\u00b0 bis 27 GHz bei Biegung. Im Gegensatz dazu k\u00f6nnen Standardkabel bei gleicher Biegung eine Phasendrift von 10\u00b0 oder mehr aufweisen, was kritische Messungen verf\u00e4lschen kann.<\/div>\n<\/div>\n<\/div>\n<div>\n<h3>Bietet TPS Pr\u00fcfungen und Dokumentation f\u00fcr HF-Kabelbaugruppen?<\/h3>\n<div>\n<div>Ja. TPS f\u00fchrt Impedanzverifikation, Einf\u00fcgungsd\u00e4mpfungspr\u00fcfung, VSWR-Pr\u00fcfung und Validierung der Phasenstabilit\u00e4t gem\u00e4\u00df IEC 61196-1-111 durch. Pr\u00fcfberichte werden f\u00fcr Qualit\u00e4tsaufzeichnungen und Audits bereitgestellt.<\/div>\n<\/div>\n<\/div>\n<div>\n<h3>Kann TPS kundenspezifische L\u00e4ngen von HF-Pr\u00fcfkabeln f\u00fcr bestimmte Pr\u00fcfplatzaufbauten herstellen?<\/h3>\n<div>\n<div>Ja. TPS fertigt HF-Pr\u00fcfkabel in kundenspezifischen L\u00e4ngen f\u00fcr spezifische Pr\u00fcfplatzkonfigurationen. Die Kabell\u00e4nge beeinflusst die Einf\u00fcgungsd\u00e4mpfung und das Phasenverhalten, daher arbeitet TPS mit Kunden zusammen, um die L\u00e4nge f\u00fcr ihre spezifische Anwendung zu optimieren.<\/div>\n<\/div>\n<\/div>\n<div>\n<h3>Was ist der Unterschied zwischen TPS-Kabelkonfektion und dem Kauf bei einer reinen Kabelwerkstatt?<\/h3>\n<div>\n<div>TPS liefert Kabelbaugruppen, die f\u00fcr die Integration in Ihren \u00fcbergeordneten elektronischen Montageworkflow validiert sind, mit koordinierter Qualit\u00e4tsdokumentation und Lieferkettenkontinuit\u00e4t. Eine reine Kabelwerkstatt liefert Teile nach Zeichnung; TPS liefert Kabelb\u00e4ume, die dokumentiert und mit Ihren Fertigungsanforderungen integriert sind.<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/section>\n<footer style=\"background: #2d5797; padding: 30px; border-radius: 14px; margin-top: 40px;\">\n<p style=\"color: #ffffff; font-size: 16px; line-height: 1.6; margin: 0;\"><strong>Bereit, Ihren HF-Pr\u00fcfplatz mit hochwertigen phasenstabilen Koaxial-Pr\u00fcfkabeln auszustatten?<\/strong><br \/>Kontaktieren Sie TPS Elektronik f\u00fcr technische Beratung, Musterevaluierung und Produktionsunterst\u00fctzung \u2013 von SMA- und BNC- bis zu N-Typ-Baugruppen mit dokumentierter Pr\u00fcfung.<br \/><a style=\"color: #ffffff; font-weight: 600; text-decoration: underline;\" href=\"https:\/\/tps-elektronik.com\/services\/ems\/kabelkonfektion\/\">Angebot f\u00fcr coaxial cable assembly anfordern \u2192<\/a><\/p>\n<\/footer><\/article>\n\n<style id=\"wpforms-css-vars-4336-block-9e3f8e06-abde-4519-a339-4929497a61bc\">\n\t\t\t\t#wpforms-4336.wpforms-block-9e3f8e06-abde-4519-a339-4929497a61bc {\n\t\t\t\t--wpforms-field-size-input-height: 43px;\n--wpforms-field-size-input-spacing: 15px;\n--wpforms-field-size-font-size: 16px;\n--wpforms-field-size-line-height: 19px;\n--wpforms-field-size-padding-h: 14px;\n--wpforms-field-size-checkbox-size: 16px;\n--wpforms-field-size-sublabel-spacing: 5px;\n--wpforms-field-size-icon-size: 1;\n--wpforms-label-size-font-size: 16px;\n--wpforms-label-size-line-height: 19px;\n--wpforms-label-size-sublabel-font-size: 14px;\n--wpforms-label-size-sublabel-line-height: 17px;\n--wpforms-button-size-font-size: 17px;\n--wpforms-button-size-height: 41px;\n--wpforms-button-size-padding-h: 15px;\n--wpforms-button-size-margin-top: 10px;\n\t\t\t}\n\t\t\t<\/style><div class=\"wpforms-container wpforms-container-full wpforms-block wpforms-block-9e3f8e06-abde-4519-a339-4929497a61bc wpforms-render-modern\" id=\"wpforms-4336\"><form id=\"wpforms-form-4336\" class=\"wpforms-validate wpforms-form wpforms-ajax-form\" data-formid=\"4336\" method=\"post\" enctype=\"multipart\/form-data\" action=\"\/fr\/wp-json\/wp\/v2\/posts\/16460\" data-token=\"6d1ba48d17c47ad28fe4758a84d7b1c1\" data-token-time=\"1788794172\"><noscript class=\"wpforms-error-noscript\">Veuillez activer JavaScript dans votre navigateur pour remplir ce formulaire.<\/noscript><div id=\"wpforms-error-noscript\" style=\"display: none;\">Veuillez activer JavaScript dans votre navigateur pour remplir ce formulaire.<\/div><div class=\"wpforms-field-container\">\t\t<div id=\"wpforms-4336-field_5-container\"\n\t\t\tclass=\"wpforms-field wpforms-field-text\"\n\t\t\tdata-field-type=\"text\"\n\t\t\tdata-field-id=\"5\"\n\t\t\t>\n\t\t\t<label class=\"wpforms-field-label\" for=\"wpforms-4336-field_5\" >E-Mail Name Firma<\/label>\n\t\t\t<input type=\"text\" id=\"wpforms-4336-field_5\" class=\"wpforms-field-medium\" name=\"wpforms[fields][5]\" >\n\t\t<\/div>\n\t\t<div id=\"wpforms-4336-field_1-container\" class=\"wpforms-field wpforms-field-name wpforms-one-half wpforms-first\" data-field-id=\"1\"><label class=\"wpforms-field-label\" for=\"wpforms-4336-field_1\">Name <span class=\"wpforms-required-label\" aria-hidden=\"true\">*<\/span><\/label><input type=\"text\" id=\"wpforms-4336-field_1\" class=\"wpforms-field-large wpforms-field-required\" name=\"wpforms[fields][1]\" aria-errormessage=\"wpforms-4336-field_1-error\" required><\/div><div id=\"wpforms-4336-field_2-container\" class=\"wpforms-field wpforms-field-email\" data-field-id=\"2\"><label class=\"wpforms-field-label\" for=\"wpforms-4336-field_2\">E-Mail <span class=\"wpforms-required-label\" aria-hidden=\"true\">*<\/span><\/label><input type=\"email\" id=\"wpforms-4336-field_2\" class=\"wpforms-field-large wpforms-field-required\" name=\"wpforms[fields][2]\" spellcheck=\"false\" aria-errormessage=\"wpforms-4336-field_2-error\" required><\/div><div id=\"wpforms-4336-field_4-container\" class=\"wpforms-field wpforms-field-text\" data-field-id=\"4\"><label class=\"wpforms-field-label\" for=\"wpforms-4336-field_4\"> Firma <span class=\"wpforms-required-label\" aria-hidden=\"true\">*<\/span><\/label><input type=\"text\" id=\"wpforms-4336-field_4\" class=\"wpforms-field-large wpforms-field-required\" name=\"wpforms[fields][4]\" aria-errormessage=\"wpforms-4336-field_4-error\" required><\/div><div id=\"wpforms-4336-field_3-container\" class=\"wpforms-field wpforms-field-textarea\" data-field-id=\"3\"><label class=\"wpforms-field-label\" for=\"wpforms-4336-field_3\">Kurzbeschreibung<\/label><textarea id=\"wpforms-4336-field_3\" class=\"wpforms-field-medium\" name=\"wpforms[fields][3]\" aria-errormessage=\"wpforms-4336-field_3-error\" ><\/textarea><\/div><div id=\"wpforms-4336-field_6-container\" class=\"wpforms-field wpforms-field-checkbox\" data-field-id=\"6\"><fieldset><legend class=\"wpforms-field-label wpforms-label-hide\" aria-hidden=\"false\">Checkboxes <span class=\"wpforms-required-label\" aria-hidden=\"true\">*<\/span><\/legend><ul id=\"wpforms-4336-field_6\" class=\"wpforms-field-required\"><li class=\"choice-1 depth-1\"><input type=\"checkbox\" id=\"wpforms-4336-field_6_1\" name=\"wpforms[fields][6][]\" value=\"Ich stimme der Verarbeitung meiner Angaben zur Angebotserstellung zu.\" aria-errormessage=\"wpforms-4336-field_6_1-error\" aria-describedby=\"wpforms-4336-field_6-description\" required ><label class=\"wpforms-field-label-inline\" for=\"wpforms-4336-field_6_1\">Ich stimme der Verarbeitung meiner Angaben zur Angebotserstellung zu.<\/label><\/li><\/ul><div id=\"wpforms-4336-field_6-description\" class=\"wpforms-field-description\">Hinweise siehe Datenschutz.<\/div><\/fieldset><\/div><script>\n\t\t\t\t( function() {\n\t\t\t\t\tconst style = document.createElement( 'style' );\n\t\t\t\t\tstyle.appendChild( document.createTextNode( '#wpforms-4336-field_5-container { position: absolute !important; overflow: hidden !important; display: inline !important; height: 1px !important; width: 1px !important; z-index: -1000 !important; padding: 0 !important; } #wpforms-4336-field_5-container input { visibility: hidden; } #wpforms-conversational-form-page #wpforms-4336-field_5-container label { counter-increment: none; }' ) );\n\t\t\t\t\tdocument.head.appendChild( style );\n\t\t\t\t\tdocument.currentScript?.remove();\n\t\t\t\t} )();\n\t\t\t<\/script><\/div><!-- .wpforms-field-container --><div class=\"wpforms-submit-container\" ><input type=\"hidden\" name=\"wpforms[id]\" value=\"4336\"><input type=\"hidden\" name=\"page_title\" value=\"\"><input type=\"hidden\" name=\"page_url\" value=\"https:\/\/tps-elektronik.com\/fr\/wp-json\/wp\/v2\/posts\/16460\"><input type=\"hidden\" name=\"url_referer\" value=\"\"><button type=\"submit\" name=\"wpforms[submit]\" id=\"wpforms-submit-4336\" class=\"wpforms-submit\" data-alt-text=\"Senden...\" data-submit-text=\"Anfrage senden\" aria-live=\"assertive\" value=\"wpforms-submit\">Anfrage senden<\/button><img decoding=\"async\" src=\"https:\/\/tps-elektronik.com\/wp-content\/plugins\/wpforms-lite\/assets\/images\/submit-spin.svg\" class=\"wpforms-submit-spinner\" style=\"display: none;\" width=\"26\" height=\"26\" alt=\"Chargement en cours\"><\/div><\/form><\/div>  <!-- .wpforms-container -->\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>F\u00fcr Systemintegratoren, Pr\u00fcfingenieure und Einkaufsteams, die Allzweck-HF-Pr\u00fcfpl\u00e4tze einrichten, ist die Qualit\u00e4t der Koaxial-Pr\u00fcfkabel kein Nebenaspekt \u2013 sie ist der Unterschied zwischen zuverl\u00e4ssigen, reproduzierbaren Messungen und stundenlanger Suche nach Phantom-Signalen. Ein Pr\u00fcfkabel mit schlechter Phasenstabilit\u00e4t, hohem VSWR oder inkonsistenter Einf\u00fcgungsd\u00e4mpfung kann aus einer einfachen Verifikation einen m\u00fchsamen Debugging-Albtraum machen. Die coaxial cable assembly\u00a0von TPS Elektronik liefern\u2026 <a href=\"https:\/\/tps-elektronik.com\/fr\/how-to-equip-general-purpose-rf-test-benches-with-high-quality-phase-stable-coaxial-test-cables-and-adapters-from-tps\/\">Read More &raquo;<\/a><\/p>\n","protected":false},"author":9,"featured_media":16592,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[60],"tags":[],"class_list":["post-16460","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-nachrichten"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.4 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Wie stattet man universelle HF-Testpl\u00e4tze mit hochwertigen phasenangepassten Koaxial-Testkabeln und Adaptern von TPS aus? - TPS<\/title>\n<meta name=\"description\" content=\"Coaxial cable assembly f\u00fcr HF-Testpl\u00e4tze mit Phasenstabilit\u00e4t, niedrigem VSWR und SMA\/BNC\/N-Adaptern.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/tps-elektronik.com\/fr\/how-to-equip-general-purpose-rf-test-benches-with-high-quality-phase-stable-coaxial-test-cables-and-adapters-from-tps\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Wie stattet man universelle HF-Testpl\u00e4tze mit hochwertigen phasenangepassten Koaxial-Testkabeln und Adaptern von TPS aus? - TPS\" \/>\n<meta property=\"og:description\" content=\"Coaxial cable assembly f\u00fcr HF-Testpl\u00e4tze mit Phasenstabilit\u00e4t, niedrigem VSWR und SMA\/BNC\/N-Adaptern.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/tps-elektronik.com\/fr\/how-to-equip-general-purpose-rf-test-benches-with-high-quality-phase-stable-coaxial-test-cables-and-adapters-from-tps\/\" \/>\n<meta property=\"og:site_name\" content=\"TPS\" \/>\n<meta property=\"article:published_time\" content=\"2026-09-07T07:00:00+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/08\/TPS-RF-Coaxial-Cable-Assembly-with-SMA-Connectors-3-1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1920\" \/>\n\t<meta property=\"og:image:height\" content=\"1079\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Tang Marcus\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u00c9crit par\" \/>\n\t<meta name=\"twitter:data1\" content=\"Tang Marcus\" \/>\n\t<meta name=\"twitter:label2\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data2\" content=\"7 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/fr\\\/how-to-equip-general-purpose-rf-test-benches-with-high-quality-phase-stable-coaxial-test-cables-and-adapters-from-tps\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/fr\\\/how-to-equip-general-purpose-rf-test-benches-with-high-quality-phase-stable-coaxial-test-cables-and-adapters-from-tps\\\/\"},\"author\":{\"name\":\"Tang Marcus\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/fr\\\/#\\\/schema\\\/person\\\/2c19fd053095d0c1ae253e8e62427b8c\"},\"headline\":\"Wie stattet man universelle HF-Testpl\u00e4tze mit hochwertigen phasenangepassten Koaxial-Testkabeln und Adaptern von TPS aus?\",\"datePublished\":\"2026-09-07T07:00:00+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/fr\\\/how-to-equip-general-purpose-rf-test-benches-with-high-quality-phase-stable-coaxial-test-cables-and-adapters-from-tps\\\/\"},\"wordCount\":1669,\"image\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/fr\\\/how-to-equip-general-purpose-rf-test-benches-with-high-quality-phase-stable-coaxial-test-cables-and-adapters-from-tps\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/tps-elektronik.com\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/TPS-RF-Coaxial-Cable-Assembly-with-SMA-Connectors-3-1.jpg\",\"articleSection\":[\"Nachrichten\"],\"inLanguage\":\"fr-FR\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/fr\\\/how-to-equip-general-purpose-rf-test-benches-with-high-quality-phase-stable-coaxial-test-cables-and-adapters-from-tps\\\/\",\"url\":\"https:\\\/\\\/tps-elektronik.com\\\/fr\\\/how-to-equip-general-purpose-rf-test-benches-with-high-quality-phase-stable-coaxial-test-cables-and-adapters-from-tps\\\/\",\"name\":\"Wie stattet man universelle HF-Testpl\u00e4tze mit hochwertigen phasenangepassten Koaxial-Testkabeln und Adaptern von TPS aus? - TPS\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/fr\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/fr\\\/how-to-equip-general-purpose-rf-test-benches-with-high-quality-phase-stable-coaxial-test-cables-and-adapters-from-tps\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/fr\\\/how-to-equip-general-purpose-rf-test-benches-with-high-quality-phase-stable-coaxial-test-cables-and-adapters-from-tps\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/tps-elektronik.com\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/TPS-RF-Coaxial-Cable-Assembly-with-SMA-Connectors-3-1.jpg\",\"datePublished\":\"2026-09-07T07:00:00+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/fr\\\/#\\\/schema\\\/person\\\/2c19fd053095d0c1ae253e8e62427b8c\"},\"description\":\"Coaxial cable assembly f\u00fcr HF-Testpl\u00e4tze mit Phasenstabilit\u00e4t, niedrigem VSWR und SMA\\\/BNC\\\/N-Adaptern.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/fr\\\/how-to-equip-general-purpose-rf-test-benches-with-high-quality-phase-stable-coaxial-test-cables-and-adapters-from-tps\\\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/tps-elektronik.com\\\/fr\\\/how-to-equip-general-purpose-rf-test-benches-with-high-quality-phase-stable-coaxial-test-cables-and-adapters-from-tps\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/fr\\\/how-to-equip-general-purpose-rf-test-benches-with-high-quality-phase-stable-coaxial-test-cables-and-adapters-from-tps\\\/#primaryimage\",\"url\":\"https:\\\/\\\/tps-elektronik.com\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/TPS-RF-Coaxial-Cable-Assembly-with-SMA-Connectors-3-1.jpg\",\"contentUrl\":\"https:\\\/\\\/tps-elektronik.com\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/TPS-RF-Coaxial-Cable-Assembly-with-SMA-Connectors-3-1.jpg\",\"width\":1920,\"height\":1079,\"caption\":\"TPS RF Coaxial Cable Assembly with SMA Connectors\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/fr\\\/how-to-equip-general-purpose-rf-test-benches-with-high-quality-phase-stable-coaxial-test-cables-and-adapters-from-tps\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Startseite\",\"item\":\"https:\\\/\\\/tps-elektronik.com\\\/fr\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Wie stattet man universelle HF-Testpl\u00e4tze mit hochwertigen phasenangepassten Koaxial-Testkabeln und Adaptern von TPS aus?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/fr\\\/#website\",\"url\":\"https:\\\/\\\/tps-elektronik.com\\\/fr\\\/\",\"name\":\"TPS\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/tps-elektronik.com\\\/fr\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/fr\\\/#\\\/schema\\\/person\\\/2c19fd053095d0c1ae253e8e62427b8c\",\"name\":\"Tang Marcus\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Wie stattet man universelle HF-Testpl\u00e4tze mit hochwertigen phasenangepassten Koaxial-Testkabeln und Adaptern von TPS aus? - TPS","description":"Coaxial cable assembly f\u00fcr HF-Testpl\u00e4tze mit Phasenstabilit\u00e4t, niedrigem VSWR und SMA\/BNC\/N-Adaptern.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/tps-elektronik.com\/fr\/how-to-equip-general-purpose-rf-test-benches-with-high-quality-phase-stable-coaxial-test-cables-and-adapters-from-tps\/","og_locale":"fr_FR","og_type":"article","og_title":"Wie stattet man universelle HF-Testpl\u00e4tze mit hochwertigen phasenangepassten Koaxial-Testkabeln und Adaptern von TPS aus? - TPS","og_description":"Coaxial cable assembly f\u00fcr HF-Testpl\u00e4tze mit Phasenstabilit\u00e4t, niedrigem VSWR und SMA\/BNC\/N-Adaptern.","og_url":"https:\/\/tps-elektronik.com\/fr\/how-to-equip-general-purpose-rf-test-benches-with-high-quality-phase-stable-coaxial-test-cables-and-adapters-from-tps\/","og_site_name":"TPS","article_published_time":"2026-09-07T07:00:00+00:00","og_image":[{"width":1920,"height":1079,"url":"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/08\/TPS-RF-Coaxial-Cable-Assembly-with-SMA-Connectors-3-1.jpg","type":"image\/jpeg"}],"author":"Tang Marcus","twitter_card":"summary_large_image","twitter_misc":{"\u00c9crit par":"Tang Marcus","Dur\u00e9e de lecture estim\u00e9e":"7 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/tps-elektronik.com\/fr\/how-to-equip-general-purpose-rf-test-benches-with-high-quality-phase-stable-coaxial-test-cables-and-adapters-from-tps\/#article","isPartOf":{"@id":"https:\/\/tps-elektronik.com\/fr\/how-to-equip-general-purpose-rf-test-benches-with-high-quality-phase-stable-coaxial-test-cables-and-adapters-from-tps\/"},"author":{"name":"Tang Marcus","@id":"https:\/\/tps-elektronik.com\/fr\/#\/schema\/person\/2c19fd053095d0c1ae253e8e62427b8c"},"headline":"Wie stattet man universelle HF-Testpl\u00e4tze mit hochwertigen phasenangepassten Koaxial-Testkabeln und Adaptern von TPS aus?","datePublished":"2026-09-07T07:00:00+00:00","mainEntityOfPage":{"@id":"https:\/\/tps-elektronik.com\/fr\/how-to-equip-general-purpose-rf-test-benches-with-high-quality-phase-stable-coaxial-test-cables-and-adapters-from-tps\/"},"wordCount":1669,"image":{"@id":"https:\/\/tps-elektronik.com\/fr\/how-to-equip-general-purpose-rf-test-benches-with-high-quality-phase-stable-coaxial-test-cables-and-adapters-from-tps\/#primaryimage"},"thumbnailUrl":"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/08\/TPS-RF-Coaxial-Cable-Assembly-with-SMA-Connectors-3-1.jpg","articleSection":["Nachrichten"],"inLanguage":"fr-FR"},{"@type":"WebPage","@id":"https:\/\/tps-elektronik.com\/fr\/how-to-equip-general-purpose-rf-test-benches-with-high-quality-phase-stable-coaxial-test-cables-and-adapters-from-tps\/","url":"https:\/\/tps-elektronik.com\/fr\/how-to-equip-general-purpose-rf-test-benches-with-high-quality-phase-stable-coaxial-test-cables-and-adapters-from-tps\/","name":"Wie stattet man universelle HF-Testpl\u00e4tze mit hochwertigen phasenangepassten Koaxial-Testkabeln und Adaptern von TPS aus? - TPS","isPartOf":{"@id":"https:\/\/tps-elektronik.com\/fr\/#website"},"primaryImageOfPage":{"@id":"https:\/\/tps-elektronik.com\/fr\/how-to-equip-general-purpose-rf-test-benches-with-high-quality-phase-stable-coaxial-test-cables-and-adapters-from-tps\/#primaryimage"},"image":{"@id":"https:\/\/tps-elektronik.com\/fr\/how-to-equip-general-purpose-rf-test-benches-with-high-quality-phase-stable-coaxial-test-cables-and-adapters-from-tps\/#primaryimage"},"thumbnailUrl":"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/08\/TPS-RF-Coaxial-Cable-Assembly-with-SMA-Connectors-3-1.jpg","datePublished":"2026-09-07T07:00:00+00:00","author":{"@id":"https:\/\/tps-elektronik.com\/fr\/#\/schema\/person\/2c19fd053095d0c1ae253e8e62427b8c"},"description":"Coaxial cable assembly f\u00fcr HF-Testpl\u00e4tze mit Phasenstabilit\u00e4t, niedrigem VSWR und SMA\/BNC\/N-Adaptern.","breadcrumb":{"@id":"https:\/\/tps-elektronik.com\/fr\/how-to-equip-general-purpose-rf-test-benches-with-high-quality-phase-stable-coaxial-test-cables-and-adapters-from-tps\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/tps-elektronik.com\/fr\/how-to-equip-general-purpose-rf-test-benches-with-high-quality-phase-stable-coaxial-test-cables-and-adapters-from-tps\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/tps-elektronik.com\/fr\/how-to-equip-general-purpose-rf-test-benches-with-high-quality-phase-stable-coaxial-test-cables-and-adapters-from-tps\/#primaryimage","url":"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/08\/TPS-RF-Coaxial-Cable-Assembly-with-SMA-Connectors-3-1.jpg","contentUrl":"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/08\/TPS-RF-Coaxial-Cable-Assembly-with-SMA-Connectors-3-1.jpg","width":1920,"height":1079,"caption":"TPS RF Coaxial Cable Assembly with SMA Connectors"},{"@type":"BreadcrumbList","@id":"https:\/\/tps-elektronik.com\/fr\/how-to-equip-general-purpose-rf-test-benches-with-high-quality-phase-stable-coaxial-test-cables-and-adapters-from-tps\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Startseite","item":"https:\/\/tps-elektronik.com\/fr\/"},{"@type":"ListItem","position":2,"name":"Wie stattet man universelle HF-Testpl\u00e4tze mit hochwertigen phasenangepassten Koaxial-Testkabeln und Adaptern von TPS aus?"}]},{"@type":"WebSite","@id":"https:\/\/tps-elektronik.com\/fr\/#website","url":"https:\/\/tps-elektronik.com\/fr\/","name":"TPS","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/tps-elektronik.com\/fr\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Person","@id":"https:\/\/tps-elektronik.com\/fr\/#\/schema\/person\/2c19fd053095d0c1ae253e8e62427b8c","name":"Tang Marcus"}]}},"_links":{"self":[{"href":"https:\/\/tps-elektronik.com\/fr\/wp-json\/wp\/v2\/posts\/16460","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/tps-elektronik.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/tps-elektronik.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/tps-elektronik.com\/fr\/wp-json\/wp\/v2\/users\/9"}],"replies":[{"embeddable":true,"href":"https:\/\/tps-elektronik.com\/fr\/wp-json\/wp\/v2\/comments?post=16460"}],"version-history":[{"count":3,"href":"https:\/\/tps-elektronik.com\/fr\/wp-json\/wp\/v2\/posts\/16460\/revisions"}],"predecessor-version":[{"id":16607,"href":"https:\/\/tps-elektronik.com\/fr\/wp-json\/wp\/v2\/posts\/16460\/revisions\/16607"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/tps-elektronik.com\/fr\/wp-json\/wp\/v2\/media\/16592"}],"wp:attachment":[{"href":"https:\/\/tps-elektronik.com\/fr\/wp-json\/wp\/v2\/media?parent=16460"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/tps-elektronik.com\/fr\/wp-json\/wp\/v2\/categories?post=16460"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/tps-elektronik.com\/fr\/wp-json\/wp\/v2\/tags?post=16460"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}