{"id":14470,"date":"2026-07-06T09:00:00","date_gmt":"2026-07-06T07:00:00","guid":{"rendered":"https:\/\/tps-elektronik.com\/?p=14470"},"modified":"2026-06-10T08:50:19","modified_gmt":"2026-06-10T06:50:19","slug":"tps-small-transformer-coil-winding-service-precision-miniature-coils-for-low-power-switch-mode-power-supplies-and-compact-dc-dc-converters","status":"publish","type":"post","link":"https:\/\/tps-elektronik.com\/fr\/tps-small-transformer-coil-winding-service-precision-miniature-coils-for-low-power-switch-mode-power-supplies-and-compact-dc-dc-converters\/","title":{"rendered":"TPS Kleintransformatoren\u2011Spulenwickelservice: Pr\u00e4zisions\u2011Miniaturspulen f\u00fcr stromsparende Schaltnetzteile und kompakte DC\u2011DC\u2011Wandler"},"content":{"rendered":"<article class=\"blog-post\" lang=\"de\"><header>\n<p>Systemintegratoren, Schaltschrankbauer und Beschaffungsteams scheitern selten, weil ihnen ein Schaltnetzteil\u2011Design fehlt. Sie verlieren Zeit. Und Budget \u2014 wenn die einzige kundenspezifische Magnetkomponente im Herzen dieses Netzteils bei keinem Katalogdistributor in der exakten Bauform, Induktivit\u00e4t und Isolationsspannung beschafft werden kann. Ein handels\u00fcblicher EFD15\u2011Sperrwandler\u2011Transformator mag das richtige \u00dcbersetzungsverh\u00e4ltnis haben, aber seine Bauh\u00f6he \u00fcberschreitet die 12\u202fmm\u2011Geh\u00e4usegrenze. Ein alternatives Teil passt zwar mechanisch, verursacht aber eine \u00fcberm\u00e4\u00dfige Streuinduktivit\u00e4t. Die die Pr\u00fcfung der leitungsgef\u00fchrten St\u00f6raussendung nicht besteht und einen kostspieligen und zeitaufw\u00e4ndigen Redesign\u2011Zyklus nur wenige Wochen vor der geplanten Compliance\u2011Einreichung erzwingt.<br \/>Der <strong>Klein transformer coil winding service<\/strong> von TPS Elektronik wurde entwickelt, um dieses Risiko zu beseitigen. Durch die Fertigung kundenspezifischer Miniaturtransformatoren, Drosseln und Spulen nach exakten elektrischen, mechanischen und thermischen Spezifikationen \u00fcberbr\u00fcckt TPS die L\u00fccke zwischen einem bew\u00e4hrten Referenzdesign und einem produktionsreifen Netzteil. Dieser Service ist speziell auf stromsparende Schaltnetzteile (SMPS) und kompakte DC\u2011DC\u2011Wandler bis etwa 100\u202fW zugeschnitten, bei denen jeder Millimeter Bauh\u00f6he und jedes Milliwatt Kernverlust ber\u00fccksichtigt werden m\u00fcssen.<\/p>\n<p><a class=\"cta-primary\" href=\"https:\/\/tps-elektronik.com\/services\/zusatzservices\/\">Fordern Sie eine Miniaturspulen\u2011Wicklungsberatung an \u2192<\/a><\/p>\n<\/header><nav class=\"toc\" aria-label=\"Inhaltsverzeichnis\">\n<h2 id=\"toc-de\">Inhaltsverzeichnis<\/h2>\n<ol>\n<li><a href=\"#de-why\">Warum kundenspezifische Miniaturwicklung f\u00fcr stromsparende SMPS wichtig ist<\/a><\/li>\n<li><a href=\"#de-capability\">TPS Kleintransformatoren\u2011Wicklungskompetenz<\/a>\n<ol>\n<li><a href=\"#de-geometry\">Unterst\u00fctzte Geometrien und Kerntypen<\/a><\/li>\n<li><a href=\"#de-wire\">Ultra\u2011Feindraht\u2011Handhabung und Isolierung<\/a><\/li>\n<\/ol>\n<\/li>\n<li><a href=\"#de-design\">Design\u00fcberlegungen: Streuung, Kopplung und EMI<\/a><\/li>\n<li><a href=\"#de-quality\">Elektrische Pr\u00fcfung und Qualit\u00e4tssicherung<\/a><\/li>\n<li><a href=\"#de-compliance\">Konformit\u00e4t und Sicherheit: IEC\u202f62368\u20111, verst\u00e4rkte Isolierung und EMV<\/a><\/li>\n<li><a href=\"#de-app\">Anwendungsbeispiele: isolierte DC\u2011DC, Gate\u2011Treiber und Hilfsversorgungen<\/a><\/li>\n<li><a href=\"#de-rfq\">RFQ\u2011Checkliste f\u00fcr die Miniaturtransformator\u2011Wicklung<\/a><\/li>\n<li><a href=\"#de-faq\">FAQ<\/a><\/li>\n<\/ol>\n<\/nav>\n<section id=\"de-why\">\n<h2>1. Warum kundenspezifische Miniaturwicklung f\u00fcr stromsparende SMPS wichtig ist<\/h2>\n<p>In einem typischen isolierten 20\u202fW\u2011Sperrwandler ist der Leistungstransformator gleichzeitig die sperrigste, schwerste und elektromagnetisch kritischste Komponente auf der Leiterplatte. Er bestimmt den Wirkungsgrad des Wandlers, seine elektromagnetische St\u00f6rabstrahlung (EMI). Seine maximale Umgebungsbetriebstemperatur und \u2014 am kritischsten f\u00fcr kompakte Designs \u2014 seine gesamte Bauh\u00f6he \u00fcber der Platine. Ein Katalog\u2011Transformator, ausgew\u00e4hlt aus dem begrenzten Sortiment eines Distributors, geht fast immer bei mindestens einem dieser Parameter Kompromisse ein.<\/p>\n<p>Ein <strong>Miniaturtransformer coil winding service<\/strong> vermeidet diese Kompromisse, indem er von der elektrischen Spezifikation ausgeht und die Magnetbaugruppe von au\u00dfen nach innen konstruiert: Auswahl des kleinsten Kerns, der den geforderten Leistungsdurchsatz ohne S\u00e4ttigung bew\u00e4ltigen kann, Spezifikation des Magnetdraht\u2011Querschnitts, der den Gleichstromwiderstand minimiert und gleichzeitig in das Spulenk\u00f6rperfenster passt, und Anordnung der Wicklungslagen zur Minimierung von Streuinduktivit\u00e4t und Wicklungskapazit\u00e4t. Die resultierende Komponente ist ein voll funktionsf\u00e4higer Leistungstransformator, der exakt in die verf\u00fcgbare PCB\u2011Grundfl\u00e4che und das H\u00f6henbudget passt und gleichzeitig die in der Produktspezifikation definierten Wirkungsgrad. Und EMI\u2011Ziele erf\u00fcllt. Die umfassendere Expertise von TPS in diesem Bereich wird in unserer \u00dcbersicht zu <a href=\"https:\/\/tps-elektronik.com\/fr\/umfassende-elektronische-design-dienstleistungen-komplettloesungen\/\">umfassenden elektronischen Designdienstleistungen f\u00fcr Komplettl\u00f6sungen<\/a> detailliert beschrieben. Die behandelt, wie kundenspezifische Magnetik in breitere Entwicklungsprogramme integriert wird.<\/p>\n<\/section>\n<section id=\"de-capability\">\n<h2>2. TPS Kleintransformatoren\u2011Wicklungskompetenz<\/h2>\n<p>TPS Elektronik betreibt Pr\u00e4zisions\u2011Spulenwickelmaschinen, die Miniaturtransformatoren mit Kernabmessungen von nur etwa 8\u202fmm (z.\u202fB. EE8.3, EP7 oder kleine Ringkerne) herstellen k\u00f6nnen. Der Service deckt das gesamte Spektrum stromsparender SMPS\u2011Topologien ab: Sperrwandler, Durchflusswandler, Gegentaktwandler, Halbbr\u00fccken- und resonante LLC\u2011Wandler. Jedes Wicklungsprojekt beginnt mit einer DFM\u2011Pr\u00fcfung, die die elektrische Spezifikation gegen die mechanischen Randbedingungen des ausgew\u00e4hlten Kerns und Spulenk\u00f6rpers verifiziert.<\/p>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-14605\" src=\"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/06\/Precision-Miniature-Transformer-Coil-Winding-SMPS-Ferrite-Core-CNC-Machine-\u2013-TPS-Elektronik-1.jpg\" alt=\"Precision Miniature Transformer Coil Winding SMPS Ferrite Core CNC Machine \u2013 TPS Elektronik\n\n\" width=\"1920\" height=\"1078\" \/><\/p>\n<h3 id=\"de-geometry\">2.1 Unterst\u00fctzte Geometrien und Kerntypen<\/h3>\n<p>TPS wickelt auf einer Vielzahl von Miniatur\u2011Ferritkerngeometrien, die jeweils ein anderes Gleichgewicht von Leistungsaufnahme, Schirmung und H\u00f6henprofil bieten. Die folgende Tabelle fasst die typischen Anwendungen zusammen:<\/p>\n<ul>\n<li><strong>EE\u2011, EF\u2011 und EFD\u2011Kerne<\/strong>: Dies sind die Arbeitstier\u2011Geometrien f\u00fcr Sperr- und Durchflusswandler, die moderate Leistungsaufnahme (5\u201350\u202fW) mit einem niedrigen Profil bieten.<\/li>\n<li><strong>EP- und EPC\u2011Kerne<\/strong>: Mit ihrem runden Mittelschenkel sind diese Kerne ideal f\u00fcr Anwendungen, bei denen eine kompakte Grundfl\u00e4che und gute magnetische Schirmung erforderlich sind.<\/li>\n<li><strong>RM- und P\u2011Kerne (Topfkerne)<\/strong>: Sie bieten die beste Selbstschirmung und werden h\u00e4ufig f\u00fcr rauscharme Anwendungen wie Pr\u00e4zisions\u2011Analogversorgungen und empfindliche Sensorschaltungen ausgew\u00e4hlt.<\/li>\n<li><strong>Ringkerne<\/strong>: Verwendet f\u00fcr Gleichtaktdrosseln, Stromwandler und wo die absolut geringste Bauh\u00f6he und das niedrigste abgestrahlte Feld ben\u00f6tigt werden.<\/li>\n<li><strong>Planarkerne (z.\u202fB. E\u2011I, E\u2011E planar)<\/strong>: Integriert mit PCB\u2011Wicklungen f\u00fcr Ultra\u2011Low\u2011Profile\u2011Designs.<\/li>\n<\/ul>\n<p>F\u00fcr jede Geometrie w\u00e4hlt TPS das geeignete Ferritmaterial \u2014 typischerweise MnZn\u2011Leistungsferrite wie 3C90, 3C94, N87 oder N97 \u2014 basierend auf der Betriebsfrequenz (20\u202fkHz bis mehrere MHz), der Spitzenflussdichte und den erforderlichen Kernverlust\u2011Eigenschaften. F\u00fcr h\u00f6herfrequente GaN\u2011basierte Wandler, die oberhalb von 1\u202fMHz arbeiten, werden verlustarme Materialien wie 3F4 oder N49 ausgew\u00e4hlt. Die F\u00e4higkeiten von TPS im Design und in der Herstellung dieser Komponenten werden auch durch die breitere Erfahrung in <a href=\"https:\/\/tps-elektronik.com\/umfassende-elektronische-design-dienstleistungen-lieferkettenloesungen\/\">Lieferkettenl\u00f6sungen f\u00fcr elektronisches Design<\/a> unterst\u00fctzt, die die Materialverf\u00fcgbarkeit sowohl f\u00fcr Prototyp- als auch f\u00fcr Produktionsvolumen sicherstellt.<\/p>\n<h3 id=\"de-wire\">2.2 Ultra\u2011Feindraht\u2011Handhabung und Isolierung<\/h3>\n<p>Miniaturtransformatoren f\u00fcr Wandler unter 20\u202fW verwenden typischerweise Magnetdraht im Bereich von 0,05\u202fmm bis 0,3\u202fmm Durchmesser (AWG\u202f44 bis AWG\u202f29). Die Handhabung von Draht unter 0,1\u202fmm erfordert eine pr\u00e4zise Zugregelung, um Drahtdehnung oder -bruch w\u00e4hrend des Wickelns zu vermeiden. Die CNC\u2011Wickelausr\u00fcstung von TPS h\u00e4lt eine kalibrierte Zugspannung \u00fcber alle Spindeln aufrecht, und der Drahtisolationstyp \u2014 Polyurethan (l\u00f6tbar, 130\u202f\u00b0C), Polyester (155\u202f\u00b0C) oder Polyimid (220\u202f\u00b0C) \u2014 wird basierend auf der von der Anwendung geforderten W\u00e4rmeklasse ausgew\u00e4hlt.<\/p>\n<p>F\u00fcr Transformatoren, die eine verst\u00e4rkte Isolierung erfordern \u2014 wie sie in medizinischen Netzteilen oder isolierten Gate\u2011Treibern verwendet werden \u2014 bringt TPS Zwischenlagen\u2011Isolierband (typischerweise Polyimid- oder Polyesterfolie) und Abstandsband auf, um die von IEC\u202f62368\u20111 oder IEC\u202f60601\u20111 spezifizierten Kriech- und Luftstrecken einzuhalten. Das Isolationssystem wird mit einer Dreifach\u2011Isolierdraht\u2011Strategie (Zusatz- oder verst\u00e4rkte Isolierung) ausgelegt, wenn die Spulenk\u00f6rpergeometrie mit Standard\u2011Magnetdraht keine ausreichende Kriechstrecke bietet, um die Konformit\u00e4t mit den Sicherheitsnormen zu gew\u00e4hrleisten. Diese Konstruktionspraktiken sind ein zentraler Bestandteil des TPS\u2011Ansatzes f\u00fcr <a href=\"https:\/\/tps-elektronik.com\/wareneingangspruefung-produktionslinien-effizienz\/\">Qualit\u00e4t und Effizienz in der Produktion<\/a>.<\/p>\n<\/section>\n<section id=\"de-design\">\n<h2>3. Design\u00fcberlegungen: Streuung, Kopplung und EMI<\/h2>\n<p>In einem kompakten Sperrwandler ist die Streuinduktivit\u00e4t der stille Feind. Sie speichert Energie, die nicht auf die Sekund\u00e4rseite \u00fcbertragen wird, und setzt sie in einer Snubber\u2011Schaltung frei oder \u2014 schlimmer \u2014 verursacht eine Spannungs\u00fcberh\u00f6hung am Prim\u00e4rschalter. Ein Miniaturtransformator mit schlechter Kopplung (niedriger Kopplungskoeffizient zwischen Prim\u00e4r- und Sekund\u00e4rseite) kann genug Gleichtaktst\u00f6rungen durch die Wicklungskapazit\u00e4t erzeugen, um die Grenzwerte f\u00fcr die leitungsgef\u00fchrte EMI bereits im ersten Test zu \u00fcberschreiten.<\/p>\n<p>TPS\u2011Ingenieure adressieren diese Probleme bereits in der Wicklungsdesign\u2011Phase. Die Streuinduktivit\u00e4t wird durch verschachtelte Wicklungstechniken minimiert \u2014 Aufteilen der Prim\u00e4rwicklung in zwei Lagen, die die Sekund\u00e4rwicklung sandwichartig umschlie\u00dfen \u2014 oder durch die Verwendung einer Folienwicklung f\u00fcr die Sekund\u00e4rseite in sehr flachen Designs. Die Wicklungskapazit\u00e4t wird durch die Wahl der Isolationsdicke und die Wicklungsanordnung (z.\u202fB. ein Z\u2011Wicklungsmuster anstelle eines einfachen Lage\u2011f\u00fcr\u2011Lage\u2011Ansatzes) kontrolliert. Diese Designoptimierungen, zusammen mit den breiteren Fertigungskapazit\u00e4ten, sind Teil des integrierten Ansatzes, der in unserer <a href=\"https:\/\/tps-elektronik.com\/fr\/case-studies\/umfassende-elektronische-dienstleistungen-beschaffung\/\">Fallstudie zu Beschaffungsl\u00f6sungen<\/a> beschrieben ist.<\/p>\n<\/section>\n<section id=\"de-quality\">\n<h2>4. Elektrische Pr\u00fcfung und Qualit\u00e4tssicherung<\/h2>\n<p>Jeder von TPS gewickelte Miniaturtransformator durchl\u00e4uft eine 100\u202f%\u2011ige elektrische Pr\u00fcfung, bevor er die Produktionsfl\u00e4che verl\u00e4sst. Das Standard\u2011Pr\u00fcfprotokoll umfasst Induktivit\u00e4ts- und \u00dcbersetzungsverh\u00e4ltnismessung, Streuinduktivit\u00e4t, Gleichstrom\u2011Wicklungswiderstand aller Wicklungen und Hochspannungspr\u00fcfung von Wicklung zu Wicklung und von Wicklung zu Kern bei der spezifizierten Isolationsspannung. Ein dokumentierter Pr\u00fcfbericht mit Messwerten begleitet jedes Produktionslos.<\/p>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-14615\" src=\"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/06\/\u7ebf\u57081.jpg\" alt=\"transformer coil winding\" width=\"1920\" height=\"1280\" srcset=\"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/06\/\u7ebf\u57081.jpg 1920w, https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/06\/\u7ebf\u57081-600x400.jpg 600w\" sizes=\"(max-width: 1920px) 100vw, 1920px\" \/><\/p>\n<p>F\u00fcr Anwendungen, bei denen eine Teilentladungspr\u00fcfung erforderlich ist \u2014 wie bei Medizinger\u00e4ten oder hochzuverl\u00e4ssiger Industrieausr\u00fcstung \u2014 kann TPS eine TE\u2011Pr\u00fcfung durchf\u00fchren, um die Abwesenheit von Hohlraumdefekten im Isolationssystem zu verifizieren, typischerweise bei Pr\u00fcfspannungen von 1,25 bis 1,5 mal der Nennisolationsspannung. Das Los\u2011R\u00fcckverfolgbarkeitssystem, verbunden mit den in unserem Leitfaden zum <a href=\"https:\/\/tps-elektronik.com\/fr\/bestandsmanagement-elektronik-komponentenlager\/\">Bestandsmanagement f\u00fcr Elektronik<\/a> beschriebenen Praktiken, stellt die vollst\u00e4ndige Material- und Prozessr\u00fcckverfolgbarkeit f\u00fcr jede Charge magnetischer Komponenten sicher.<\/p>\n<\/section>\n<section id=\"de-compliance\">\n<h2>5. Konformit\u00e4t und Sicherheit: IEC\u202f62368\u20111, verst\u00e4rkte Isolierung und EMV<\/h2>\n<p>Jeder Transformator, der eine Sicherheits\u2011Isolationsbarriere \u00fcberbr\u00fcckt, muss die relevante Produktsicherheitsnorm erf\u00fcllen. F\u00fcr Industrie- und IT\u2011Ger\u00e4te ist <a href=\"https:\/\/webstore.iec.ch\/en\/publication\/69308\" target=\"_blank\" rel=\"noopener noreferrer nofollow\">IEC\u202f62368\u20111<\/a> die ma\u00dfgebende Norm, die Anforderungen an elektrischen Schlag, Feuer, mechanische und thermische Gefahren definiert. F\u00fcr medizinische Anwendungen gilt IEC\u202f60601\u20111 mit strengeren Grenzwerten f\u00fcr Ableitstrom und Isolationsdicke.<\/p>\n<p>TPS konstruiert Miniaturtransformatoren zur Erf\u00fcllung dieser Normen, indem die korrekten Isolationsmaterialien spezifiziert, Kriech- und Luftstrecken gegen die Betriebsspannung verifiziert und die erforderlichen Durchschlagsfestigkeits- und Teilentladungspr\u00fcfungen durchgef\u00fchrt werden. Eine Konformit\u00e4tserkl\u00e4rung unter Bezugnahme auf die anwendbaren Normen wird mit jedem Produktionslos bereitgestellt. TPS ber\u00fccksichtigt auch die Rolle des Transformators in der gesamten EMV\u2011Leistung des Endprodukts; obwohl der Transformator eine passive Komponente im EMI\u2011Pfad ist, beeinflussen seine parasit\u00e4ren Kapazit\u00e4ten und Kerneigenschaften die leitungsgef\u00fchrte St\u00f6raussendung erheblich, ein Thema, das in unseren Ressourcen zur <a href=\"https:\/\/tps-elektronik.com\/produktionseffizienz-verbessern-wareneingangspruefung-linienoptimierung\/\">Verbesserung der Produktionseffizienz durch Pr\u00fcfung<\/a> weiter untersucht wird.<\/p>\n<\/section>\n<section id=\"de-app\">\n<h2>6. Anwendungsbeispiele: isolierte DC\u2011DC, Gate\u2011Treiber und Hilfsversorgungen<\/h2>\n<p>Miniaturgewickelte Transformatoren und Drosseln von TPS finden sich in einer Vielzahl kompakter Stromversorgungsanwendungen:<\/p>\n<ul>\n<li><strong>Isolierte DC\u2011DC\u2011Wandler<\/strong>: Brick- und SIP\u2011Format\u2011Isolierwandler (1\u201330\u202fW) f\u00fcr Industrie\u2011, Medizin- und Bahnstromversorgungen, bei denen verst\u00e4rkte Isolierung und kompakte Gr\u00f6\u00dfe von gr\u00f6\u00dfter Bedeutung sind. Diese Designs verwenden oft EFD\u2011, EP- oder Planarkerne.<\/li>\n<li><strong>Isolierte Gate\u2011Treiber<\/strong>: Impulstransformatoren f\u00fcr IGBT\u2011, MOSFET- und SiC\u2011Gate\u2011Treiberschaltungen, bei denen niedrige Wicklungskapazit\u00e4t, hohe dv\/dt\u2011Festigkeit und ein konsistentes \u00dcbersetzungsverh\u00e4ltnis f\u00fcr sicheres Schalten entscheidend sind. Ringkerne oder kleine RM\u2011Kerne sind typische Wahlm\u00f6glichkeiten.<\/li>\n<li><strong>Hilfsstromversorgungen<\/strong>: Standby\u2011Sperrwandler, die einige Watt aus einem Hochspannungs\u2011DC\u2011Bus liefern, wobei ein kundenspezifischer EE8- oder EF12\u2011Transformator die erforderliche Vorspannung in einer minimalen Grundfl\u00e4che liefert.<\/li>\n<li><strong>Isolierte Sensoren und Signalaufbereitung<\/strong>: Miniatur\u2011Stromwandler und Isolations\u00fcbertrager f\u00fcr analoge Signalpfade, bei denen Genauigkeit und Linearit\u00e4t entscheidend sind.<\/li>\n<\/ul>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-14610\" src=\"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/06\/IEC-62368\u20111-Certified-Miniature-Transformer-Coil-Label-Safety-Compliance-Documentation-\u2013-TPS-Elektronik-5.jpg\" alt=\"IEC 62368\u20111 Certified Miniature Transformer Coil Label Safety Compliance Documentation \u2013 TPS Elektronik\n\n\" width=\"1920\" height=\"1078\" \/><\/p>\n<p><a class=\"cta-primary\" href=\"https:\/\/tps-elektronik.com\/services\/zusatzservices\/\">Besprechen Sie Ihre Miniaturtransformator\u2011Anforderungen mit TPS \u2192<\/a><\/p>\n<\/section>\n<section id=\"de-rfq\">\n<h2>7. RFQ\u2011Checkliste f\u00fcr die Miniaturtransformator\u2011Wicklung<\/h2>\n<ul>\n<li><strong>Elektrische Spezifikation<\/strong>: Nominelle Eingangs\u2011 und Ausgangsspannung, Schaltfrequenz, Ausgangsleistung, Zielwirkungsgrad.<\/li>\n<li><strong>Induktivit\u00e4t und \u00dcbersetzungsverh\u00e4ltnis<\/strong>: Prim\u00e4rinduktivit\u00e4t, Streuinduktivit\u00e4ts\u2011Grenzwert, \u00dcbersetzungsverh\u00e4ltnis (NP:NS:NAux).<\/li>\n<li><strong>Kernpr\u00e4ferenz<\/strong>: Bevorzugter Kerntyp\/-gr\u00f6\u00dfe oder eine maximale mechanische H\u00fcllkurve (L\u202f\u00d7\u202fB\u202f\u00d7\u202fH in mm).<\/li>\n<li><strong>Isolationsanforderungen<\/strong>: Funktions-, Basis- oder verst\u00e4rkte Isolierung; Betriebsspannung und erforderliche Pr\u00fcfspannung.<\/li>\n<li><strong>Anschlussart<\/strong>: Durchsteck\u2011Pins (Pinabstand), SMD\u2011Pads oder freie Leitungen mit spezifizierter L\u00e4nge.<\/li>\n<li><strong>Anwendbare Normen<\/strong>: Sicherheitsnorm (IEC\u202f62368\u20111, IEC\u202f60601\u20111) und etwaige erforderliche Zertifizierungen.<\/li>\n<li><strong>St\u00fcckzahlen und Zeitplan<\/strong>: Prototyp\u2011, Pilot- und Serienvolumen mit Ziel-Lieferterminen.<\/li>\n<li><strong>Dokumentation<\/strong>: Erforderliche Pr\u00fcfberichte und Zertifikate.<\/li>\n<\/ul>\n<p><a class=\"cta-primary\" href=\"https:\/\/tps-elektronik.com\/services\/zusatzservices\/\">Reichen Sie Ihre RFQ f\u00fcr Miniaturtransformatoren ein \u2192<\/a><\/p>\n<\/section>\n<section id=\"de-faq\">\n<h2>8. FAQ<\/h2>\n<p><strong>Was ist der kleinste Transformatorkern, den TPS wickeln kann?<\/strong><br \/>TPS wickelt Kerne bis zu einer Gr\u00f6\u00dfe von etwa 8\u202fmm (z.\u202fB. EE8.3, EP7) unter Verwendung von Ultra\u2011Feindraht mit pr\u00e4ziser Zugregelung. Das praktische Minimum h\u00e4ngt von der Anzahl der Windungen, dem \u00dcbersetzungsverh\u00e4ltnis und den Isolationsanforderungen ab.<\/p>\n<p><strong>Kann TPS Dreifach\u2011Isolierdraht f\u00fcr verst\u00e4rkte Isolierung wickeln?<\/strong><br \/>Ja. TPS wickelt regelm\u00e4\u00dfig Transformatoren mit Dreifach\u2011Isolierdraht (TEX\u2011E, TIW\u2011B usw.), um eine verst\u00e4rkte Isolierung in kompakten Spulenk\u00f6rpergr\u00f6\u00dfen zu erreichen, bei denen Standard\u2011Abstandsband keine ausreichende Kriechstrecke bietet.<\/p>\n<p><strong>Liefert TPS Prototyp\u2011St\u00fcckzahlen f\u00fcr die Designvalidierung?<\/strong><br \/>Ja. TPS unterst\u00fctzt Prototyp\u2011Builds mit kurzen Lieferzeiten. Prototypen werden auf denselben Maschinen gewickelt, die f\u00fcr die Serienproduktion verwendet werden, was sicherstellt, dass die validierte Leistung im Volumen reproduzierbar ist.<\/p>\n<p><strong>Wie stellt TPS eine gleichbleibende Transformatorleistung \u00fcber Produktionschargen hinweg sicher?<\/strong><br \/>TPS verwendet kalibrierte CNC\u2011Wickelausr\u00fcstung, dokumentierte Einrichtungsverfahren und 100\u202f%\u2011ige elektrische Pr\u00fcfung. Los\u2011R\u00fcckverfolgbarkeit und Erstmusterpr\u00fcfung (FAI) sind Standard und stellen die Konsistenz zwischen Prototyp und Produktion sicher.<\/p>\n<p><strong>Wo finde ich weitere Informationen zu den umfassenderen Elektronikdesign\u2011 und Fertigungskapazit\u00e4ten von TPS?<\/strong><br \/>Besuchen Sie die <a href=\"https:\/\/tps-elektronik.com\/services\/zusatzservices\/\">TPS Zusatzservices\u2011Seite<\/a> oder lesen Sie \u00fcber unsere <a href=\"https:\/\/tps-elektronik.com\/fr\/umfassende-elektronische-design-dienstleistungen-komplettloesungen\/\">umfassenden elektronischen Designdienstleistungen<\/a> und <a href=\"https:\/\/tps-elektronik.com\/fr\/bestandsmanagement-verpackungsdienstleistungen-elektronikindustrie\/\">Bestandsmanagement\u2011L\u00f6sungen<\/a>.<\/p>\n<\/section>\n<footer style=\"background: #2d5797; padding: 30px; border-radius: 14px; margin-top: 40px;\">\n<p style=\"color: #ffffff; font-size: 16px; line-height: 1.6; margin: 0;\"><strong>Bereit, ein Kompromiss\u2011Katalogteil durch einen kundenspezifischen Miniaturtransformator zu ersetzen, der perfekt passt?<\/strong><br \/>Kontaktieren Sie TPS Elektronik f\u00fcr einen Pr\u00e4zisions\u2011Spulenwickelservice, der die exakte Induktivit\u00e4t, den Formfaktor und die Isolierung liefert, die Ihr stromsparendes SMPS oder Ihr DC\u2011DC\u2011Wandler verlangt.<br \/><a style=\"color: #ffffff; font-weight: 600; text-decoration: underline; display: block; margin-top: 10px;\" href=\"https:\/\/tps-elektronik.com\/services\/zusatzservices\/\">Jetzt Beratung zur Miniaturtransformator\u2011Spulenwicklung anfordern \u2192<\/a><\/p>\n<\/footer><\/article>\n\n<style id=\"wpforms-css-vars-4336-block-e692b984-dab7-41f5-9c31-3289dcd11c2d\">\n\t\t\t\t#wpforms-4336.wpforms-block-e692b984-dab7-41f5-9c31-3289dcd11c2d {\n\t\t\t\t--wpforms-field-size-input-height: 43px;\n--wpforms-field-size-input-spacing: 15px;\n--wpforms-field-size-font-size: 16px;\n--wpforms-field-size-line-height: 19px;\n--wpforms-field-size-padding-h: 14px;\n--wpforms-field-size-checkbox-size: 16px;\n--wpforms-field-size-sublabel-spacing: 5px;\n--wpforms-field-size-icon-size: 1;\n--wpforms-label-size-font-size: 16px;\n--wpforms-label-size-line-height: 19px;\n--wpforms-label-size-sublabel-font-size: 14px;\n--wpforms-label-size-sublabel-line-height: 17px;\n--wpforms-button-size-font-size: 17px;\n--wpforms-button-size-height: 41px;\n--wpforms-button-size-padding-h: 15px;\n--wpforms-button-size-margin-top: 10px;\n\t\t\t}\n\t\t\t<\/style><div class=\"wpforms-container wpforms-container-full wpforms-block wpforms-block-e692b984-dab7-41f5-9c31-3289dcd11c2d wpforms-render-modern\" id=\"wpforms-4336\"><form id=\"wpforms-form-4336\" class=\"wpforms-validate wpforms-form wpforms-ajax-form\" data-formid=\"4336\" method=\"post\" enctype=\"multipart\/form-data\" action=\"\/fr\/wp-json\/wp\/v2\/posts\/14470\" data-token=\"c929a327745680231f8c5c19fb1a37ff\" data-token-time=\"1783589429\"><noscript class=\"wpforms-error-noscript\">Veuillez activer JavaScript dans votre navigateur pour remplir ce formulaire.<\/noscript><div id=\"wpforms-error-noscript\" style=\"display: none;\">Veuillez activer JavaScript dans votre navigateur pour remplir ce formulaire.<\/div><div class=\"wpforms-field-container\">\t\t<div id=\"wpforms-4336-field_5-container\"\n\t\t\tclass=\"wpforms-field wpforms-field-text\"\n\t\t\tdata-field-type=\"text\"\n\t\t\tdata-field-id=\"5\"\n\t\t\t>\n\t\t\t<label class=\"wpforms-field-label\" for=\"wpforms-4336-field_5\" > Checkboxes Firma<\/label>\n\t\t\t<input type=\"text\" id=\"wpforms-4336-field_5\" class=\"wpforms-field-medium\" name=\"wpforms[fields][5]\" >\n\t\t<\/div>\n\t\t<div id=\"wpforms-4336-field_1-container\" class=\"wpforms-field wpforms-field-name wpforms-one-half wpforms-first\" data-field-id=\"1\"><label class=\"wpforms-field-label\" for=\"wpforms-4336-field_1\">Name <span class=\"wpforms-required-label\" aria-hidden=\"true\">*<\/span><\/label><input type=\"text\" id=\"wpforms-4336-field_1\" class=\"wpforms-field-large wpforms-field-required\" name=\"wpforms[fields][1]\" aria-errormessage=\"wpforms-4336-field_1-error\" required><\/div><div id=\"wpforms-4336-field_2-container\" class=\"wpforms-field wpforms-field-email\" data-field-id=\"2\"><label class=\"wpforms-field-label\" for=\"wpforms-4336-field_2\">E-Mail <span class=\"wpforms-required-label\" aria-hidden=\"true\">*<\/span><\/label><input type=\"email\" id=\"wpforms-4336-field_2\" class=\"wpforms-field-large wpforms-field-required\" name=\"wpforms[fields][2]\" spellcheck=\"false\" aria-errormessage=\"wpforms-4336-field_2-error\" required><\/div><div id=\"wpforms-4336-field_4-container\" class=\"wpforms-field wpforms-field-text\" data-field-id=\"4\"><label class=\"wpforms-field-label\" for=\"wpforms-4336-field_4\"> Firma <span class=\"wpforms-required-label\" aria-hidden=\"true\">*<\/span><\/label><input type=\"text\" id=\"wpforms-4336-field_4\" class=\"wpforms-field-large wpforms-field-required\" name=\"wpforms[fields][4]\" aria-errormessage=\"wpforms-4336-field_4-error\" required><\/div><div id=\"wpforms-4336-field_3-container\" class=\"wpforms-field wpforms-field-textarea\" data-field-id=\"3\"><label class=\"wpforms-field-label\" for=\"wpforms-4336-field_3\">Kurzbeschreibung<\/label><textarea id=\"wpforms-4336-field_3\" class=\"wpforms-field-medium\" name=\"wpforms[fields][3]\" aria-errormessage=\"wpforms-4336-field_3-error\" ><\/textarea><\/div><div id=\"wpforms-4336-field_6-container\" class=\"wpforms-field wpforms-field-checkbox\" data-field-id=\"6\"><fieldset><legend class=\"wpforms-field-label wpforms-label-hide\" aria-hidden=\"false\">Checkboxes <span class=\"wpforms-required-label\" aria-hidden=\"true\">*<\/span><\/legend><ul id=\"wpforms-4336-field_6\" class=\"wpforms-field-required\"><li class=\"choice-1 depth-1\"><input type=\"checkbox\" id=\"wpforms-4336-field_6_1\" name=\"wpforms[fields][6][]\" value=\"Ich stimme der Verarbeitung meiner Angaben zur Angebotserstellung zu.\" aria-errormessage=\"wpforms-4336-field_6_1-error\" aria-describedby=\"wpforms-4336-field_6-description\" required ><label class=\"wpforms-field-label-inline\" for=\"wpforms-4336-field_6_1\">Ich stimme der Verarbeitung meiner Angaben zur Angebotserstellung zu.<\/label><\/li><\/ul><div id=\"wpforms-4336-field_6-description\" class=\"wpforms-field-description\">Hinweise siehe Datenschutz.<\/div><\/fieldset><\/div><script>\n\t\t\t\t( function() {\n\t\t\t\t\tconst style = document.createElement( 'style' );\n\t\t\t\t\tstyle.appendChild( document.createTextNode( '#wpforms-4336-field_5-container { position: absolute !important; overflow: hidden !important; display: inline !important; height: 1px !important; width: 1px !important; z-index: -1000 !important; padding: 0 !important; } #wpforms-4336-field_5-container input { visibility: hidden; } #wpforms-conversational-form-page #wpforms-4336-field_5-container label { counter-increment: none; }' ) );\n\t\t\t\t\tdocument.head.appendChild( style );\n\t\t\t\t\tdocument.currentScript?.remove();\n\t\t\t\t} )();\n\t\t\t<\/script><\/div><!-- .wpforms-field-container --><div class=\"wpforms-submit-container\" ><input type=\"hidden\" name=\"wpforms[id]\" value=\"4336\"><input type=\"hidden\" name=\"page_title\" value=\"\"><input type=\"hidden\" name=\"page_url\" value=\"https:\/\/tps-elektronik.com\/fr\/wp-json\/wp\/v2\/posts\/14470\"><input type=\"hidden\" name=\"url_referer\" value=\"\"><button type=\"submit\" name=\"wpforms[submit]\" id=\"wpforms-submit-4336\" class=\"wpforms-submit\" data-alt-text=\"Senden...\" data-submit-text=\"Anfrage senden\" aria-live=\"assertive\" value=\"wpforms-submit\">Anfrage senden<\/button><img decoding=\"async\" src=\"https:\/\/tps-elektronik.com\/wp-content\/plugins\/wpforms-lite\/assets\/images\/submit-spin.svg\" class=\"wpforms-submit-spinner\" style=\"display: none;\" width=\"26\" height=\"26\" alt=\"Chargement en cours\"><\/div><\/form><\/div>  <!-- .wpforms-container -->","protected":false},"excerpt":{"rendered":"<p>Systemintegratoren, Schaltschrankbauer und Beschaffungsteams scheitern selten, weil ihnen ein Schaltnetzteil\u2011Design fehlt. Sie verlieren Zeit. Und Budget \u2014 wenn die einzige kundenspezifische Magnetkomponente im Herzen dieses Netzteils bei keinem Katalogdistributor in der exakten Bauform, Induktivit\u00e4t und Isolationsspannung beschafft werden kann. Ein handels\u00fcblicher EFD15\u2011Sperrwandler\u2011Transformator mag das richtige \u00dcbersetzungsverh\u00e4ltnis haben, aber seine Bauh\u00f6he \u00fcberschreitet die 12\u202fmm\u2011Geh\u00e4usegrenze. Ein alternatives\u2026 <a href=\"https:\/\/tps-elektronik.com\/fr\/tps-small-transformer-coil-winding-service-precision-miniature-coils-for-low-power-switch-mode-power-supplies-and-compact-dc-dc-converters\/\">Read More &raquo;<\/a><\/p>\n","protected":false},"author":9,"featured_media":14615,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[59],"tags":[],"class_list":["post-14470","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog-inhalt"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.0 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>TPS Kleintransformatoren\u2011Spulenwickelservice: Pr\u00e4zisions\u2011Miniaturspulen f\u00fcr stromsparende Schaltnetzteile und kompakte DC\u2011DC\u2011Wandler - TPS<\/title>\n<meta name=\"description\" content=\"TPS Klein transformer coil winding service liefert pr\u00e4zise Miniaturspulen f\u00fcr stromsparende SMPS und kompakte DC\u2011DC\u2011Wandler. Kundenspezifisches Design, enge Toleranzen, volle Dokumentation.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/tps-elektronik.com\/fr\/tps-small-transformer-coil-winding-service-precision-miniature-coils-for-low-power-switch-mode-power-supplies-and-compact-dc-dc-converters\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"TPS Kleintransformatoren\u2011Spulenwickelservice: Pr\u00e4zisions\u2011Miniaturspulen f\u00fcr stromsparende Schaltnetzteile und kompakte DC\u2011DC\u2011Wandler - TPS\" \/>\n<meta property=\"og:description\" content=\"TPS Klein transformer coil winding service liefert pr\u00e4zise Miniaturspulen f\u00fcr stromsparende SMPS und kompakte DC\u2011DC\u2011Wandler. Kundenspezifisches Design, enge Toleranzen, volle Dokumentation.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/tps-elektronik.com\/fr\/tps-small-transformer-coil-winding-service-precision-miniature-coils-for-low-power-switch-mode-power-supplies-and-compact-dc-dc-converters\/\" \/>\n<meta property=\"og:site_name\" content=\"TPS\" \/>\n<meta property=\"article:published_time\" content=\"2026-07-06T07:00:00+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/06\/\u7ebf\u57081.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1920\" \/>\n\t<meta property=\"og:image:height\" content=\"1280\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Tang Marcus\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u00c9crit par\" \/>\n\t<meta name=\"twitter:data1\" content=\"Tang Marcus\" \/>\n\t<meta name=\"twitter:label2\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data2\" content=\"9 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/fr\\\/tps-small-transformer-coil-winding-service-precision-miniature-coils-for-low-power-switch-mode-power-supplies-and-compact-dc-dc-converters\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/fr\\\/tps-small-transformer-coil-winding-service-precision-miniature-coils-for-low-power-switch-mode-power-supplies-and-compact-dc-dc-converters\\\/\"},\"author\":{\"name\":\"Tang Marcus\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/fr\\\/#\\\/schema\\\/person\\\/2c19fd053095d0c1ae253e8e62427b8c\"},\"headline\":\"TPS Kleintransformatoren\u2011Spulenwickelservice: Pr\u00e4zisions\u2011Miniaturspulen f\u00fcr stromsparende Schaltnetzteile und kompakte DC\u2011DC\u2011Wandler\",\"datePublished\":\"2026-07-06T07:00:00+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/fr\\\/tps-small-transformer-coil-winding-service-precision-miniature-coils-for-low-power-switch-mode-power-supplies-and-compact-dc-dc-converters\\\/\"},\"wordCount\":1975,\"image\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/fr\\\/tps-small-transformer-coil-winding-service-precision-miniature-coils-for-low-power-switch-mode-power-supplies-and-compact-dc-dc-converters\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/tps-elektronik.com\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/\u7ebf\u57081.jpg\",\"articleSection\":[\"Blog-Inhalt\"],\"inLanguage\":\"fr-FR\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/fr\\\/tps-small-transformer-coil-winding-service-precision-miniature-coils-for-low-power-switch-mode-power-supplies-and-compact-dc-dc-converters\\\/\",\"url\":\"https:\\\/\\\/tps-elektronik.com\\\/fr\\\/tps-small-transformer-coil-winding-service-precision-miniature-coils-for-low-power-switch-mode-power-supplies-and-compact-dc-dc-converters\\\/\",\"name\":\"TPS Kleintransformatoren\u2011Spulenwickelservice: Pr\u00e4zisions\u2011Miniaturspulen f\u00fcr stromsparende Schaltnetzteile und kompakte DC\u2011DC\u2011Wandler - TPS\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/fr\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/fr\\\/tps-small-transformer-coil-winding-service-precision-miniature-coils-for-low-power-switch-mode-power-supplies-and-compact-dc-dc-converters\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/fr\\\/tps-small-transformer-coil-winding-service-precision-miniature-coils-for-low-power-switch-mode-power-supplies-and-compact-dc-dc-converters\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/tps-elektronik.com\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/\u7ebf\u57081.jpg\",\"datePublished\":\"2026-07-06T07:00:00+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/fr\\\/#\\\/schema\\\/person\\\/2c19fd053095d0c1ae253e8e62427b8c\"},\"description\":\"TPS Klein transformer coil winding service liefert pr\u00e4zise Miniaturspulen f\u00fcr stromsparende SMPS und kompakte DC\u2011DC\u2011Wandler. Kundenspezifisches Design, enge Toleranzen, volle Dokumentation.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/fr\\\/tps-small-transformer-coil-winding-service-precision-miniature-coils-for-low-power-switch-mode-power-supplies-and-compact-dc-dc-converters\\\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/tps-elektronik.com\\\/fr\\\/tps-small-transformer-coil-winding-service-precision-miniature-coils-for-low-power-switch-mode-power-supplies-and-compact-dc-dc-converters\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/fr\\\/tps-small-transformer-coil-winding-service-precision-miniature-coils-for-low-power-switch-mode-power-supplies-and-compact-dc-dc-converters\\\/#primaryimage\",\"url\":\"https:\\\/\\\/tps-elektronik.com\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/\u7ebf\u57081.jpg\",\"contentUrl\":\"https:\\\/\\\/tps-elektronik.com\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/\u7ebf\u57081.jpg\",\"width\":1920,\"height\":1280,\"caption\":\"transformer coil winding\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/fr\\\/tps-small-transformer-coil-winding-service-precision-miniature-coils-for-low-power-switch-mode-power-supplies-and-compact-dc-dc-converters\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Startseite\",\"item\":\"https:\\\/\\\/tps-elektronik.com\\\/fr\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"TPS Kleintransformatoren\u2011Spulenwickelservice: Pr\u00e4zisions\u2011Miniaturspulen f\u00fcr stromsparende Schaltnetzteile und kompakte DC\u2011DC\u2011Wandler\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/fr\\\/#website\",\"url\":\"https:\\\/\\\/tps-elektronik.com\\\/fr\\\/\",\"name\":\"TPS\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/tps-elektronik.com\\\/fr\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/fr\\\/#\\\/schema\\\/person\\\/2c19fd053095d0c1ae253e8e62427b8c\",\"name\":\"Tang Marcus\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"TPS Kleintransformatoren\u2011Spulenwickelservice: Pr\u00e4zisions\u2011Miniaturspulen f\u00fcr stromsparende Schaltnetzteile und kompakte DC\u2011DC\u2011Wandler - TPS","description":"TPS Klein transformer coil winding service liefert pr\u00e4zise Miniaturspulen f\u00fcr stromsparende SMPS und kompakte DC\u2011DC\u2011Wandler. Kundenspezifisches Design, enge Toleranzen, volle Dokumentation.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/tps-elektronik.com\/fr\/tps-small-transformer-coil-winding-service-precision-miniature-coils-for-low-power-switch-mode-power-supplies-and-compact-dc-dc-converters\/","og_locale":"fr_FR","og_type":"article","og_title":"TPS Kleintransformatoren\u2011Spulenwickelservice: Pr\u00e4zisions\u2011Miniaturspulen f\u00fcr stromsparende Schaltnetzteile und kompakte DC\u2011DC\u2011Wandler - TPS","og_description":"TPS Klein transformer coil winding service liefert pr\u00e4zise Miniaturspulen f\u00fcr stromsparende SMPS und kompakte DC\u2011DC\u2011Wandler. Kundenspezifisches Design, enge Toleranzen, volle Dokumentation.","og_url":"https:\/\/tps-elektronik.com\/fr\/tps-small-transformer-coil-winding-service-precision-miniature-coils-for-low-power-switch-mode-power-supplies-and-compact-dc-dc-converters\/","og_site_name":"TPS","article_published_time":"2026-07-06T07:00:00+00:00","og_image":[{"width":1920,"height":1280,"url":"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/06\/\u7ebf\u57081.jpg","type":"image\/jpeg"}],"author":"Tang Marcus","twitter_card":"summary_large_image","twitter_misc":{"\u00c9crit par":"Tang Marcus","Dur\u00e9e de lecture estim\u00e9e":"9 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/tps-elektronik.com\/fr\/tps-small-transformer-coil-winding-service-precision-miniature-coils-for-low-power-switch-mode-power-supplies-and-compact-dc-dc-converters\/#article","isPartOf":{"@id":"https:\/\/tps-elektronik.com\/fr\/tps-small-transformer-coil-winding-service-precision-miniature-coils-for-low-power-switch-mode-power-supplies-and-compact-dc-dc-converters\/"},"author":{"name":"Tang Marcus","@id":"https:\/\/tps-elektronik.com\/fr\/#\/schema\/person\/2c19fd053095d0c1ae253e8e62427b8c"},"headline":"TPS Kleintransformatoren\u2011Spulenwickelservice: Pr\u00e4zisions\u2011Miniaturspulen f\u00fcr stromsparende Schaltnetzteile und kompakte DC\u2011DC\u2011Wandler","datePublished":"2026-07-06T07:00:00+00:00","mainEntityOfPage":{"@id":"https:\/\/tps-elektronik.com\/fr\/tps-small-transformer-coil-winding-service-precision-miniature-coils-for-low-power-switch-mode-power-supplies-and-compact-dc-dc-converters\/"},"wordCount":1975,"image":{"@id":"https:\/\/tps-elektronik.com\/fr\/tps-small-transformer-coil-winding-service-precision-miniature-coils-for-low-power-switch-mode-power-supplies-and-compact-dc-dc-converters\/#primaryimage"},"thumbnailUrl":"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/06\/\u7ebf\u57081.jpg","articleSection":["Blog-Inhalt"],"inLanguage":"fr-FR"},{"@type":"WebPage","@id":"https:\/\/tps-elektronik.com\/fr\/tps-small-transformer-coil-winding-service-precision-miniature-coils-for-low-power-switch-mode-power-supplies-and-compact-dc-dc-converters\/","url":"https:\/\/tps-elektronik.com\/fr\/tps-small-transformer-coil-winding-service-precision-miniature-coils-for-low-power-switch-mode-power-supplies-and-compact-dc-dc-converters\/","name":"TPS Kleintransformatoren\u2011Spulenwickelservice: Pr\u00e4zisions\u2011Miniaturspulen f\u00fcr stromsparende Schaltnetzteile und kompakte DC\u2011DC\u2011Wandler - TPS","isPartOf":{"@id":"https:\/\/tps-elektronik.com\/fr\/#website"},"primaryImageOfPage":{"@id":"https:\/\/tps-elektronik.com\/fr\/tps-small-transformer-coil-winding-service-precision-miniature-coils-for-low-power-switch-mode-power-supplies-and-compact-dc-dc-converters\/#primaryimage"},"image":{"@id":"https:\/\/tps-elektronik.com\/fr\/tps-small-transformer-coil-winding-service-precision-miniature-coils-for-low-power-switch-mode-power-supplies-and-compact-dc-dc-converters\/#primaryimage"},"thumbnailUrl":"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/06\/\u7ebf\u57081.jpg","datePublished":"2026-07-06T07:00:00+00:00","author":{"@id":"https:\/\/tps-elektronik.com\/fr\/#\/schema\/person\/2c19fd053095d0c1ae253e8e62427b8c"},"description":"TPS Klein transformer coil winding service liefert pr\u00e4zise Miniaturspulen f\u00fcr stromsparende SMPS und kompakte DC\u2011DC\u2011Wandler. Kundenspezifisches Design, enge Toleranzen, volle Dokumentation.","breadcrumb":{"@id":"https:\/\/tps-elektronik.com\/fr\/tps-small-transformer-coil-winding-service-precision-miniature-coils-for-low-power-switch-mode-power-supplies-and-compact-dc-dc-converters\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/tps-elektronik.com\/fr\/tps-small-transformer-coil-winding-service-precision-miniature-coils-for-low-power-switch-mode-power-supplies-and-compact-dc-dc-converters\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/tps-elektronik.com\/fr\/tps-small-transformer-coil-winding-service-precision-miniature-coils-for-low-power-switch-mode-power-supplies-and-compact-dc-dc-converters\/#primaryimage","url":"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/06\/\u7ebf\u57081.jpg","contentUrl":"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/06\/\u7ebf\u57081.jpg","width":1920,"height":1280,"caption":"transformer coil winding"},{"@type":"BreadcrumbList","@id":"https:\/\/tps-elektronik.com\/fr\/tps-small-transformer-coil-winding-service-precision-miniature-coils-for-low-power-switch-mode-power-supplies-and-compact-dc-dc-converters\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Startseite","item":"https:\/\/tps-elektronik.com\/fr\/"},{"@type":"ListItem","position":2,"name":"TPS Kleintransformatoren\u2011Spulenwickelservice: Pr\u00e4zisions\u2011Miniaturspulen f\u00fcr stromsparende Schaltnetzteile und kompakte DC\u2011DC\u2011Wandler"}]},{"@type":"WebSite","@id":"https:\/\/tps-elektronik.com\/fr\/#website","url":"https:\/\/tps-elektronik.com\/fr\/","name":"TPS","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/tps-elektronik.com\/fr\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Person","@id":"https:\/\/tps-elektronik.com\/fr\/#\/schema\/person\/2c19fd053095d0c1ae253e8e62427b8c","name":"Tang Marcus"}]}},"_links":{"self":[{"href":"https:\/\/tps-elektronik.com\/fr\/wp-json\/wp\/v2\/posts\/14470","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/tps-elektronik.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/tps-elektronik.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/tps-elektronik.com\/fr\/wp-json\/wp\/v2\/users\/9"}],"replies":[{"embeddable":true,"href":"https:\/\/tps-elektronik.com\/fr\/wp-json\/wp\/v2\/comments?post=14470"}],"version-history":[{"count":3,"href":"https:\/\/tps-elektronik.com\/fr\/wp-json\/wp\/v2\/posts\/14470\/revisions"}],"predecessor-version":[{"id":14619,"href":"https:\/\/tps-elektronik.com\/fr\/wp-json\/wp\/v2\/posts\/14470\/revisions\/14619"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/tps-elektronik.com\/fr\/wp-json\/wp\/v2\/media\/14615"}],"wp:attachment":[{"href":"https:\/\/tps-elektronik.com\/fr\/wp-json\/wp\/v2\/media?parent=14470"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/tps-elektronik.com\/fr\/wp-json\/wp\/v2\/categories?post=14470"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/tps-elektronik.com\/fr\/wp-json\/wp\/v2\/tags?post=14470"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}