{"id":14631,"date":"2026-07-10T09:00:00","date_gmt":"2026-07-10T07:00:00","guid":{"rendered":"https:\/\/tps-elektronik.com\/?p=14631"},"modified":"2026-06-16T10:26:26","modified_gmt":"2026-06-16T08:26:26","slug":"what-is-tps-high-power-bidirectional-programmable-power-supply-for-high-density-ate-systems-and-why-it-is-ideal-for-space-saving-and-energy-efficient-test-labs","status":"publish","type":"post","link":"https:\/\/tps-elektronik.com\/es\/what-is-tps-high-power-bidirectional-programmable-power-supply-for-high-density-ate-systems-and-why-it-is-ideal-for-space-saving-and-energy-efficient-test-labs\/","title":{"rendered":"Was ist das TPS Hochleistungs\u2011Bidirektionale Programmierbare DC\u2011Netzteil f\u00fcr High\u2011Density\u2011ATE\u2011Systeme und warum ist es ideal f\u00fcr platzsparende und energieeffiziente Testlabore?"},"content":{"rendered":"<article class=\"product-blog\" lang=\"de\"><header>\n<p>F\u00fcr Systemintegratoren, Schaltschrankbauer und technisch orientierte Beschaffungsteams geht es bei der Auswahl eines Netzteils f\u00fcr ein automatisiertes Testsystem nicht nur um Spannungs\u2011 und Stromwerte. Es geht auch um Rack\u2011Dichte, Energieeffizienz, W\u00e4rmemanagement und darum, ob das System reale Lastbedingungen \u2014 wie das Laden und Entladen einer Batterie \u2014 ohne separate Instrumente simulieren kann. Wenn ein Testlabor 42\u202fHE Rack\u2011Platz f\u00fcr Netzteile reserviert, die in 16\u202fHE untergebracht werden k\u00f6nnten, verschwendet es wertvolle Stellfl\u00e4che und erh\u00f6ht die K\u00fchlkosten.<\/p>\n<p>Das <a href=\"https:\/\/www.shop-tps.com\/de\/shop\/category\/programmierbare-labornetzgerate-14\" target=\"_blank\" rel=\"noopener noreferrer nofollow\"><strong>TPS bidirectional programmable power supply<\/strong><\/a>, basierend auf der EA\u2011PSBE\u202f10000\u2011Serie und beispielhaft dargestellt durch das EA\u2011PSBE\u202f10360\u2011240\u202f4U, adressiert diese Herausforderungen direkt. Es liefert bis zu 30\u202fkW regenerative DC\u2011Leistung in einem einzigen 4U\u2011Chassis, arbeitet sowohl als Quelle als auch als elektronische Last und f\u00fchrt aufgenommene Energie mit bis zu 95,8\u202f% Effizienz ins Netz zur\u00fcck. F\u00fcr hochdichte ATE\u2011Systeme, Batterietestlabore und EV\u2011Ladeger\u00e4t\u2011Pr\u00fcfst\u00e4nde bedeutet dies weniger Racks, niedrigere Stromrechnungen und ein einzelnes Instrument, das zwei ersetzt.<\/p>\n<\/header><nav class=\"toc\" aria-label=\"Inhaltsverzeichnis\">\n<h2 id=\"toc-de\">Inhaltsverzeichnis<\/h2>\n<ol>\n<li><a href=\"#de-what-it-is\">Was ein bidirektionales programmierbares Netzteil ist und warum ATE\u2011Systeme es ben\u00f6tigen<\/a><\/li>\n<li><a href=\"#de-power-density\">Leistungsdichte und Platzersparnis: 30\u202fkW in 4U<\/a><\/li>\n<li><a href=\"#de-bidirectional\">Bidirektionaler und regenerativer Betrieb: wie es Energie spart<\/a><\/li>\n<li><a href=\"#de-autoranging\">Autoranging\u2011Ausgang: flexible Spannung und Strom in einem Ger\u00e4t<\/a><\/li>\n<li><a href=\"#de-scalability\">Skalierbarkeit: Master\u2011Slave\u2011Parallelbetrieb bis zu 1.920\u202fkW<\/a><\/li>\n<li><a href=\"#de-control\">Steuerung, Schnittstellen und Software<\/a><\/li>\n<li><a href=\"#de-compliance\">Konformit\u00e4t und Sicherheit<\/a><\/li>\n<li><a href=\"#de-applications\">Anwendungsszenarien: Batterietest, EV\u2011Ladeger\u00e4t, Brennstoffzelle<\/a><\/li>\n<li><a href=\"#de-rfq\">RFQ\u2011Checkliste<\/a><\/li>\n<li><a href=\"#de-faq\">H\u00e4ufig gestellte Fragen<\/a><\/li>\n<\/ol>\n<\/nav>\n<section>\n<h2 id=\"de-what-it-is\">Was ein bidirektionales programmierbares Netzteil ist und warum ATE\u2011Systeme es ben\u00f6tigen<\/h2>\n<p>Ein herk\u00f6mmliches DC\u2011Netzteil speist Strom in ein Pr\u00fcfobjekt ein. Wenn der Test verlangt, dass das Pr\u00fcfobjekt Energie abgibt \u2014 wie eine Batterie w\u00e4hrend eines Kapazit\u00e4tstests \u2014 muss eine separate elektronische Last diese Energie als W\u00e4rme ableiten. Diese Konfiguration verbraucht Rack\u2011Platz, erzeugt Abw\u00e4rme und vernichtet nutzbare elektrische Energie. Ein <strong>bidirectional programmable power supply<\/strong>\u00a0fasst beide Funktionen in einem einzigen Instrument zusammen. Es kann Leistung liefern (als Netzteil fungieren) oder Leistung aufnehmen (als regenerative elektronische Last fungieren) und die aufgenommene Energie ins Netz zur\u00fcckspeisen, anstatt sie in W\u00e4rme umzuwandeln.<\/p>\n<p>In einem ATE\u2011System, das Elektrofahrzeug\u2011Batterien, On\u2011Board\u2011Ladeger\u00e4te oder Brennstoffzellen testet, ist diese F\u00e4higkeit transformativ. Dasselbe Instrument, das eine Batterie w\u00e4hrend einer Testsequenz l\u00e4dt, kann sie w\u00e4hrend der n\u00e4chsten entladen, wobei die Entladeenergie zur\u00fcckgewonnen und innerhalb der Anlage wiederverwendet wird. Dies reduziert den gesamten elektrischen Energieverbrauch des Testsystems, senkt die Klimatisierungslast im Labor und eliminiert die Kosten f\u00fcr die Anschaffung und Wartung separater Lasten. F\u00fcr einen tieferen Einblick, wie programmierbare Netzteile in Testumgebungen eingesetzt werden, siehe den TPS\u2011Leitfaden zu <a href=\"https:\/\/tps-elektronik.com\/es\/top-auswahl-an-programmierbaren-netzteilen-fuer-jede-anforderung\/\">Top\u2011Auswahl an programmierbaren Netzteilen f\u00fcr jede Anforderung<\/a>.<\/p>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-14772\" src=\"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/06\/0710-Programmable-Bidirectional-DC-Power-Supply-1.jpg\" alt=\"bidirectional programmable power supply\" width=\"700\" height=\"394\" \/><\/p>\n<\/section>\n<section>\n<h2 id=\"de-power-density\">Leistungsdichte und Platzersparnis: 30\u202fkW in 4U<\/h2>\n<p>Rack\u2011Platz in einem Testlabor ist ein festes Gut. Ein 42\u2011HE\u2011Rack, das mit 5\u202fkW\u2011Einzelfunktions\u2011Netzteilen best\u00fcckt ist, k\u00f6nnte insgesamt 60\u202fkW liefern und l\u00e4sst keinen Platz f\u00fcr das Pr\u00fcfobjekt. Das TPS EA\u2011PSBE\u202f10360\u2011240 liefert 30\u202fkW aus einem einzigen 4U\u2011Chassis. Sechs solcher Ger\u00e4te in einem 42\u2011HE\u2011Rack liefern bis zu 180\u202fkW und verdreifachen so effektiv die aus derselben Stellfl\u00e4che verf\u00fcgbare Leistung. Diese hohe Leistungsdichte wird durch eine Kombination aus fortschrittlicher Schalttechnologie, effizientem thermischem Design mit Zwangsbel\u00fcftung und einem kompakten mechanischen Layout erreicht, das die Leistungselektronik, die Steuerschaltung und die Frontpanel\u2011Schnittstelle in ein Standard\u201119\u2011Zoll\u2011Rack\u2011Mount\u2011Formfaktor integriert.<\/p>\n<p>F\u00fcr Labore, die neue ATE\u2011Installationen aufbauen oder bestehende nachr\u00fcsten, setzt sich die Platzersparnis direkt in vermiedene Investitionskosten um \u2014 weniger Racks, weniger Verkabelung und reduzierte Bodenfl\u00e4che. Der 4U\u2011Formfaktor ist eine von mehreren Rack\u2011Mount\u2011Optionen, die TPS anbietet, und erg\u00e4nzt die <a href=\"https:\/\/www.shop-tps.com\/de\/shop\/category\/programmierbare-labornetzgerate-19inch-3-he-188\" target=\"_blank\" rel=\"noopener noreferrer nofollow\">3U programmierbaren DC\u2011Netzteile<\/a> und <a href=\"https:\/\/www.shop-tps.com\/de\/shop\/category\/programmierbare-labornetzgerate-19inch-2-he-187\" target=\"_blank\" rel=\"noopener noreferrer nofollow\">2U programmierbaren DC\u2011Netzteile<\/a> f\u00fcr Kan\u00e4le mit niedrigerer Leistung.<\/p>\n<\/section>\n<section>\n<h2 id=\"de-bidirectional\">Bidirektionaler und regenerativer Betrieb: wie es Energie spart<\/h2>\n<p>Die Energieeffizienz eines bidirektionalen Netzteils bemisst sich nicht nur an seinem Umwandlungswirkungsgrad bei der Leistungsabgabe, sondern auch an seiner F\u00e4higkeit, Energie bei der Aufnahme zur\u00fcckzugewinnen. Das EA\u2011PSBE\u202f10360\u2011240 erreicht bis zu 95,8\u202f% Effizienz im Senken\u2011Modus, was bedeutet, dass \u00fcber 95\u202f% der vom Pr\u00fcfobjekt aufgenommenen Energie zur\u00fcck in Wechselstrom umgewandelt und ins Netz zur\u00fcckgespeist werden. Die verbleibenden Verluste werden als W\u00e4rme im Ger\u00e4t abgegeben und vom K\u00fchlsystem abgef\u00fchrt.<\/p>\n<p>Dies steht im Gegensatz zu einer konventionellen elektronischen Last, die 100\u202f% der aufgenommenen Energie in W\u00e4rme umwandelt und dann zus\u00e4tzliche Klimatisierung ben\u00f6tigt, um diese W\u00e4rme aus dem Labor zu entfernen. Die Gesamtbetriebskostenverbesserung ist erheblich: Ein 30\u202fkW\u2011Test, der kontinuierlich mit voller Senkenleistung l\u00e4uft, spart im Vergleich zu einer ohmschen Last etwa 262.800\u202fkWh pro Jahr, ausgehend von 8.760 Betriebsstunden. Bei typischen Industriestrompreisen stellt dies eine signifikante Betriebskostenreduzierung dar, die den Preisunterschied zwischen einem unidirektionalen und einem bidirektionalen Netzteil oft bereits im ersten Betriebsjahr amortisiert.<\/p>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-14782\" src=\"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/06\/Energy-Recovery-Bidirectional-Power-Supply-Test-Laboratory-Efficiency-Savings-Graph-\u2013-TPS-Elektronik-2.jpg\" alt=\"Energy Recovery Bidirectional Power Supply Test Laboratory Efficiency Savings Graph \u2013 TPS Elektronik\n\n\" width=\"1920\" height=\"1078\" \/><\/p>\n<\/section>\n<section>\n<h2 id=\"de-autoranging\">Autoranging\u2011Ausgang: flexible Spannung und Strom in einem Ger\u00e4t<\/h2>\n<p>Konventionelle Netzteile haben eine feste Maximalspannung und einen festen Maximalstrom. Um die volle Leistung zu liefern, muss die Last genau die maximale Nennspannung beim maximalen Nennstrom beziehen. In der Praxis arbeiten die meisten Testanwendungen nie an diesem exakten Punkt. Ein traditionelles 360\u202fV, 80\u202fA\u2011Netzteil kann 28,8\u202fkW nur bei 360\u202fV liefern. Bei niedrigeren Spannungen \u2014 beispielsweise 200\u202fV \u2014 bleibt der maximale Strom 80\u202fA, wodurch die Ausgangsleistung auf 16\u202fkW begrenzt wird.<\/p>\n<p>Das EA\u2011PSBE\u202f10360\u2011240 verwendet eine Autoranging\u2011Ausgangsstufe, die die volle Leistung (30\u202fkW) \u00fcber einen weiten Spannungsbereich liefert \u2014 bei diesem Modell etwa 125\u202fV bis 360\u202fV \u2014, indem der verf\u00fcgbare Strom erh\u00f6ht wird, wenn die Spannung sinkt. Bei 125\u202fV kann das Ger\u00e4t bis zu 240\u202fA liefern oder aufnehmen und h\u00e4lt die vollen 30\u202fkW Nennleistung. Diese Flexibilit\u00e4t bedeutet, dass ein einziges Ger\u00e4t mehrere Netzteile mit festem Bereich ersetzen kann und Anwendungen von Niederspannungs\u2011, Hochstrom\u2011Batterietests bis hin zu Hochspannungs\u2011, Mittelstrom\u2011Wechselrichtertests abdeckt. F\u00fcr zus\u00e4tzliche Details zu platzsparenden Formfaktoren siehe den Leitfaden zu <a href=\"https:\/\/tps-elektronik.com\/es\/1u-programmierbare-dc-stromversorgung-leitfaden\/\">1U programmierbaren DC\u2011Netzteilen f\u00fcr platzsparende Setups<\/a>.<\/p>\n<\/section>\n<section>\n<h2 id=\"de-scalability\">Skalierbarkeit: Master\u2011Slave\u2011Parallelbetrieb bis zu 1.920\u202fkW<\/h2>\n<p>Einzelne Testsysteme enden selten bei 30\u202fkW. Batteriepack\u2011Tests f\u00fcr Elektrofahrzeuge, netzgekoppelte Wechselrichter\u2011Validierung und gro\u00df angelegte Brennstoffzellen\u2011Charakterisierung erfordern alle Hunderte von Kilowatt. Das EA\u2011PSBE\u202f10360\u2011240 unterst\u00fctzt den Master\u2011Slave\u2011Parallelbetrieb von bis zu 64 Ger\u00e4ten und schafft so ein einziges synchronisiertes System, das bis zu 1.920\u202fkW (1,92\u202fMW) liefern kann. Das Master\u2011Ger\u00e4t steuert das gesamte Array, pr\u00e4sentiert dem Bediener eine einzige Schnittstelle und gew\u00e4hrleistet eine gleichm\u00e4\u00dfige Stromaufteilung \u00fcber alle Ger\u00e4te.<\/p>\n<p>Diese Skalierbarkeit ist besonders wertvoll f\u00fcr Systemintegratoren, die modulare ATE\u2011Architekturen entwerfen. Ein Basissystem kann mit zwei Ger\u00e4ten beginnen, die 60\u202fkW liefern, und schrittweise erweitert werden, wenn die Testanforderungen wachsen, ohne vorhandene Hardware ersetzen zu m\u00fcssen. Die TPS <a href=\"https:\/\/www.shop-tps.com\/de\/shop\/category\/programmierbare-labornetzgerate-19inch-6-he-193\" target=\"_blank\" rel=\"noopener noreferrer nofollow\">6U programmierbaren DC\u2011Netzteile<\/a> unterst\u00fctzen ebenfalls diese Parallelkonfiguration f\u00fcr Anwendungen, bei denen eine noch h\u00f6here Leistungsdichte pro Chassis bevorzugt wird.<\/p>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-14787\" src=\"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/06\/Multi\u2011Unit-Parallel-Bidirectional-Power-Supply-System-1920-kW-ATE-Rack-Configuration-\u2013-TPS-Elektronik-1.jpg\" alt=\"Multi\u2011Unit Parallel Bidirectional Power Supply System 1920 kW ATE Rack Configuration \u2013 TPS Elektronik\n\n\" width=\"1920\" height=\"1004\" \/><\/p>\n<\/section>\n<section>\n<h2 id=\"de-control\">Steuerung, Schnittstellen und Software<\/h2>\n<p>Die Integration in eine ATE\u2011Umgebung erfordert mehr als nur rohe Leistung. Das EA\u2011PSBE\u202f10360\u2011240 verf\u00fcgt standardm\u00e4\u00dfig \u00fcber eingebaute USB\u2011 und Ethernet\u2011Schnittstellen sowie eine isolierte analoge Schnittstelle (DB15) zur direkten Verbindung mit SPS oder Datenerfassungssystemen. Der digitale Regelkreis verwendet 16\u2011Bit\u2011ADCs und DACs und bietet eine pr\u00e4zise Spannungs\u2011 und Stromregelung mit w\u00e4hlbarer Regelgeschwindigkeit (Normal, Schnell, Langsam), um den dynamischen Anforderungen verschiedener Testprofile gerecht zu werden.<\/p>\n<p>F\u00fcr Batterietests bietet TPS die EA\u2011Battery Simulator Software an, die es dem Netzteil erm\u00f6glicht, das elektrische Verhalten verschiedener Batteriechemien nachzubilden. F\u00fcr die allgemeine ATE\u2011Steuerung bietet die EA\u2011Power Control Software eine umfassende Programmierumgebung. Beide Pakete unterst\u00fctzen SCPI\u2011Befehle und erm\u00f6glichen die Integration mit LabVIEW, Python, MATLAB und anderen Testautomatisierungsplattformen. Optionale Schnittstellen umfassen CAN, CANopen, Profibus, Profinet, EtherCAT und Modbus TCP.<\/p>\n<\/section>\n<section>\n<h2 id=\"de-compliance\">Konformit\u00e4t und Sicherheit<\/h2>\n<p>Sicherheits\u2011 und EMV\u2011Konformit\u00e4t sind entscheidend f\u00fcr Ger\u00e4te, die in industriellen und Laborumgebungen installiert werden. Das EA\u2011PSBE\u202f10360\u2011240 ist so konstruiert, dass es die Anforderungen der <a href=\"https:\/\/webstore.iec.ch\/en\/publication\/69308\" target=\"_blank\" rel=\"noopener noreferrer nofollow\">IEC\u202f62368\u20111<\/a> f\u00fcr Audio\u2011\/Video\u2011, Informations\u2011 und Kommunikationstechnikger\u00e4te erf\u00fcllt \u2014 der gefahrenbasierten Sicherheitsnorm, die die IEC\u202f60950\u20111 abgel\u00f6st hat. Die EMV\u2011Konformit\u00e4t wird gegen EN\u202f55032 Klasse\u202fA (CISPR\u202f32) f\u00fcr leitungsgef\u00fchrte und gestrahlte St\u00f6raussendungen sowie gegen die Normenreihe IEC\u202f61000\u20114\u2011x f\u00fcr St\u00f6rfestigkeit nachgewiesen. Der aktive Leistungsfaktorkorrektur\u2011Schaltkreis h\u00e4lt einen typischen Leistungsfaktor von 0,99 ein und erf\u00fcllt die in IEC\u202f61000\u20113\u20112 definierten Grenzwerte f\u00fcr Oberschwingungsstr\u00f6me.<\/p>\n<p>Zu den Schutzfunktionen geh\u00f6ren einstellbarer \u00dcberspannungs\u2011, \u00dcberstrom\u2011 und \u00dcberlastschutz sowie eine \u00dcbertemperaturabschaltung. Das Ger\u00e4t ist f\u00fcr die CE\u2011Kennzeichnung geeignet und unterst\u00fctzt die eigene regulatorische Dokumentation des Integrators. F\u00fcr die Tischger\u00e4te\u2011Formfaktor\u2011\u00c4quivalent dieser Technologie siehe das <a href=\"https:\/\/tps-elektronik.com\/es\/ea-psi-9000-dt-programmierbare-dc-tischnetzgeraete\/\">EA\u2011PSI\u202f9000\u202fDT programmierbare DC\u2011Tischnetzger\u00e4t<\/a>.<\/p>\n<\/section>\n<section>\n<h2 id=\"de-applications\">Anwendungsszenarien: Batterietest, EV\u2011Ladeger\u00e4t, Brennstoffzelle<\/h2>\n<p>Das EA\u2011PSBE\u202f10360\u2011240 wird in mehreren stark wachsenden Testsektoren eingesetzt:<\/p>\n<ul>\n<li><strong>Batterietest und -simulation<\/strong>: Lade\u2011\/Entlade\u2011Zyklen f\u00fcr Zell\u2011, Modul- und Pack\u2011Tests, mit Energier\u00fcckgewinnung w\u00e4hrend der Entladezyklen. Der Autoranging\u2011Ausgang deckt die breiten Spannungsbereiche ab, die f\u00fcr verschiedene Pack\u2011Konfigurationen ben\u00f6tigt werden.<\/li>\n<li><strong>Test von On\u2011Board\u2011Ladeger\u00e4ten (OBC) f\u00fcr Elektrofahrzeuge<\/strong>: Simuliert die Batterie w\u00e4hrend des OBC\u2011Tests, nimmt die Ausgangsleistung des Ladeger\u00e4ts auf und speist sie regenerativ ins Netz zur\u00fcck. Die bidirektionale F\u00e4higkeit erm\u00f6glicht auch das Testen der Vehicle\u2011to\u2011Grid (V2G)\u2011Funktionalit\u00e4t.<\/li>\n<li><strong>Brennstoffzellen\u2011Charakterisierung<\/strong>: Bietet eine kontrollierte Last f\u00fcr Brennstoffzellen\u2011Stacks und misst die Leistung unter variierenden Lastbedingungen, w\u00e4hrend die erzeugte Energie zur\u00fcckgewonnen wird.<\/li>\n<li><strong>Einbrenntest von Netzteilen und Wandlern<\/strong>: Wendet eine bidirektionale Last auf ein Pr\u00fcfobjekt an und wechselt zwischen Quelle und Senke, um die Leistungselektronik einem Stresstest zu unterziehen.<\/li>\n<\/ul>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-14777\" src=\"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/06\/TPS-Bidirectional-Power-Supply-Battery-Simulation-On\u2011Board-Charger-Test-Application-\u2013-TPS-Elektronik-3.jpg\" alt=\"TPS Bidirectional Power Supply Battery Simulation On\u2011Board Charger Test Application \u2013 TPS Elektronik\n\n\" width=\"1920\" height=\"1078\" \/><\/p>\n<\/section>\n<section>\n<h2 id=\"de-rfq\">RFQ\u2011Checkliste<\/h2>\n<ul>\n<li><strong>Leistungs\u2011 und Spannungsanforderungen<\/strong>: Maximale Leistung (kW), ben\u00f6tigter Spannungs\u2011 und Strombereich.<\/li>\n<li><strong>Formfaktor<\/strong>: Tischger\u00e4t, 1U, 2U, 3U, 4U oder 6U Rack\u2011Mount.<\/li>\n<li><strong>Bidirektionale Anforderung<\/strong>: Ist regeneratives Senken erforderlich, oder reicht die Quellenfunktion aus?<\/li>\n<li><strong>Anzahl der Kan\u00e4le<\/strong>: Einzelkanal oder mehrkanalig, mit etwaigen Parallelbetriebsanforderungen.<\/li>\n<li><strong>Schnittstellen<\/strong>: USB, Ethernet, CAN, Profibus, EtherCAT oder andere.<\/li>\n<li><strong>Software<\/strong>: EA\u2011Power Control, EA\u2011Battery Simulator oder kundenspezifische Integration.<\/li>\n<li><strong>St\u00fcckzahlen und Zeitplan<\/strong>: Prototyp\u2011, Pilot- und Serienvolumen.<\/li>\n<\/ul>\n<p><a href=\"https:\/\/www.shop-tps.com\/de\/shop\/category\/programmierbare-labornetzgerate-14\" target=\"_blank\" rel=\"noopener noreferrer nofollow\"><strong>Durchsuchen Sie TPS programmierbare Netzteile \u2192<\/strong><\/a><\/p>\n<\/section>\n<section>\n<h2 id=\"de-faq\">H\u00e4ufig gestellte Fragen<\/h2>\n<p><strong>Was ist der Unterschied zwischen einem bidirektionalen und einem unidirektionalen programmierbaren Netzteil?<\/strong><br \/>Ein unidirektionales Netzteil kann nur Leistung liefern. Ein bidirektionales Netzteil kann sowohl Leistung liefern als auch aufnehmen und fungiert als elektronische Last, die Energie ins Netz zur\u00fcckspeist, anstatt sie als W\u00e4rme abzugeben.<\/p>\n<p><strong>Wie viel Energie kann ein bidirektionales Netzteil im Vergleich zu einem traditionellen Setup einsparen?<\/strong><br \/>Im Senken\u2011Modus werden bis zu 95,8\u202f% der aufgenommenen Energie ins Netz zur\u00fcckgespeist. Ein 30\u202fkW\u2011System, das kontinuierlich mit voller Senkenleistung l\u00e4uft, kann im Vergleich zu einer ohmschen Last \u00fcber 260.000\u202fkWh pro Jahr einsparen und die Betriebskosten erheblich senken.<\/p>\n<p><strong>K\u00f6nnen mehrere TPS\u2011bidirektionale Netzteile f\u00fcr h\u00f6here Leistung parallelgeschaltet werden?<\/strong><br \/>Ja. Bis zu 64 Ger\u00e4te des EA\u2011PSBE\u202f10360\u2011240 k\u00f6nnen in einer Master\u2011Slave\u2011Konfiguration verbunden werden und liefern bis zu 1.920\u202fkW aus einem einzigen synchronisierten System.<\/p>\n<p><strong>Welche Kommunikationsschnittstellen sind verf\u00fcgbar?<\/strong><br \/>Eingebaute Schnittstellen umfassen USB und Ethernet. Optionale Feldbus\u2011Schnittstellen umfassen CAN, CANopen, Profibus, Profinet, EtherCAT und Modbus TCP. Die isolierte analoge Schnittstelle (DB15) erm\u00f6glicht die direkte analoge Steuerung.<\/p>\n<p><strong>Wo finde ich die gesamte Produktpalette?<\/strong><br \/>Besuchen Sie die <a href=\"https:\/\/www.shop-tps.com\/de\/shop\/category\/programmierbare-labornetzgerate-14\" target=\"_blank\" rel=\"noopener noreferrer nofollow\">TPS Kategorie f\u00fcr programmierbare Netzteile<\/a>, die <a href=\"https:\/\/www.shop-tps.com\/de\/shop\/category\/programmierbare-labornetzgerate-tischgerate-192\" target=\"_blank\" rel=\"noopener noreferrer nofollow\">Tischger\u00e4te<\/a>, <a href=\"https:\/\/www.shop-tps.com\/de\/shop\/category\/programmierbare-labornetzgerate-19inch-1-he-186\" target=\"_blank\" rel=\"noopener noreferrer nofollow\">1U<\/a>, <a href=\"https:\/\/www.shop-tps.com\/de\/shop\/category\/programmierbare-labornetzgerate-19inch-2-he-187\" target=\"_blank\" rel=\"noopener noreferrer nofollow\">2U<\/a>, <a href=\"https:\/\/www.shop-tps.com\/de\/shop\/category\/programmierbare-labornetzgerate-19inch-3-he-188\" target=\"_blank\" rel=\"noopener noreferrer nofollow\">3U<\/a>, <a href=\"https:\/\/www.shop-tps.com\/de\/shop\/category\/programmierbare-labornetzgerate-19inch-4-he-189\" target=\"_blank\" rel=\"noopener noreferrer nofollow\">4U<\/a> und <a href=\"https:\/\/www.shop-tps.com\/de\/shop\/category\/programmierbare-labornetzgerate-19inch-6-he-193\" target=\"_blank\" rel=\"noopener noreferrer nofollow\">6U<\/a> Modelle umfasst.<\/p>\n<\/section>\n<footer style=\"background: #2d5797; padding: 30px; border-radius: 14px; margin-top: 40px;\">\n<p style=\"color: #ffffff; font-size: 16px; line-height: 1.6; margin: 0;\"><strong>N\u00e4chster Schritt:<\/strong> Statten Sie Ihr Testlabor mit einem Hochleistungs\u2011Bidirektionalen Netzteil aus, das Platz spart und Energie zur\u00fcckgewinnt. <a style=\"color: #ffffff; font-weight: 600; text-decoration: underline; display: block; margin-top: 10px;\" href=\"https:\/\/www.shop-tps.com\/de\/shop\/category\/programmierbare-labornetzgerate-14\" target=\"_blank\" rel=\"noopener noreferrer nofollow\">Durchsuchen Sie TPS programmierbare Netzteile \u2192<\/a><\/p>\n<\/footer><\/article>\n\n<style id=\"wpforms-css-vars-4336-block-644e25d9-59ca-48e0-966e-25cb8acd9cc2\">\n\t\t\t\t#wpforms-4336.wpforms-block-644e25d9-59ca-48e0-966e-25cb8acd9cc2 {\n\t\t\t\t--wpforms-field-size-input-height: 43px;\n--wpforms-field-size-input-spacing: 15px;\n--wpforms-field-size-font-size: 16px;\n--wpforms-field-size-line-height: 19px;\n--wpforms-field-size-padding-h: 14px;\n--wpforms-field-size-checkbox-size: 16px;\n--wpforms-field-size-sublabel-spacing: 5px;\n--wpforms-field-size-icon-size: 1;\n--wpforms-label-size-font-size: 16px;\n--wpforms-label-size-line-height: 19px;\n--wpforms-label-size-sublabel-font-size: 14px;\n--wpforms-label-size-sublabel-line-height: 17px;\n--wpforms-button-size-font-size: 17px;\n--wpforms-button-size-height: 41px;\n--wpforms-button-size-padding-h: 15px;\n--wpforms-button-size-margin-top: 10px;\n\t\t\t}\n\t\t\t<\/style><div class=\"wpforms-container wpforms-container-full wpforms-block wpforms-block-644e25d9-59ca-48e0-966e-25cb8acd9cc2 wpforms-render-modern\" id=\"wpforms-4336\"><form id=\"wpforms-form-4336\" class=\"wpforms-validate wpforms-form wpforms-ajax-form\" data-formid=\"4336\" method=\"post\" enctype=\"multipart\/form-data\" action=\"\/es\/wp-json\/wp\/v2\/posts\/14631\" data-token=\"8ad83a0eb438ca2144273756a45cdc6a\" data-token-time=\"1783832107\"><noscript class=\"wpforms-error-noscript\">Por favor, activa JavaScript en tu navegador para completar este formulario.<\/noscript><div id=\"wpforms-error-noscript\" style=\"display: none;\">Por favor, activa JavaScript en tu navegador para completar este formulario.<\/div><div class=\"wpforms-field-container\">\t\t<div id=\"wpforms-4336-field_5-container\"\n\t\t\tclass=\"wpforms-field wpforms-field-text\"\n\t\t\tdata-field-type=\"text\"\n\t\t\tdata-field-id=\"5\"\n\t\t\t>\n\t\t\t<label class=\"wpforms-field-label\" for=\"wpforms-4336-field_5\" >Name Kurzbeschreibung Firma<\/label>\n\t\t\t<input type=\"text\" id=\"wpforms-4336-field_5\" class=\"wpforms-field-medium\" name=\"wpforms[fields][5]\" >\n\t\t<\/div>\n\t\t<div id=\"wpforms-4336-field_1-container\" class=\"wpforms-field wpforms-field-name wpforms-one-half wpforms-first\" data-field-id=\"1\"><label class=\"wpforms-field-label\" for=\"wpforms-4336-field_1\">Name <span class=\"wpforms-required-label\" aria-hidden=\"true\">*<\/span><\/label><input type=\"text\" id=\"wpforms-4336-field_1\" class=\"wpforms-field-large wpforms-field-required\" name=\"wpforms[fields][1]\" aria-errormessage=\"wpforms-4336-field_1-error\" required><\/div><div id=\"wpforms-4336-field_2-container\" class=\"wpforms-field wpforms-field-email\" data-field-id=\"2\"><label class=\"wpforms-field-label\" for=\"wpforms-4336-field_2\">E-Mail <span class=\"wpforms-required-label\" aria-hidden=\"true\">*<\/span><\/label><input type=\"email\" id=\"wpforms-4336-field_2\" class=\"wpforms-field-large wpforms-field-required\" name=\"wpforms[fields][2]\" spellcheck=\"false\" aria-errormessage=\"wpforms-4336-field_2-error\" required><\/div><div id=\"wpforms-4336-field_4-container\" class=\"wpforms-field wpforms-field-text\" data-field-id=\"4\"><label class=\"wpforms-field-label\" for=\"wpforms-4336-field_4\"> Firma <span class=\"wpforms-required-label\" aria-hidden=\"true\">*<\/span><\/label><input type=\"text\" id=\"wpforms-4336-field_4\" class=\"wpforms-field-large wpforms-field-required\" name=\"wpforms[fields][4]\" aria-errormessage=\"wpforms-4336-field_4-error\" required><\/div><div id=\"wpforms-4336-field_3-container\" class=\"wpforms-field wpforms-field-textarea\" data-field-id=\"3\"><label class=\"wpforms-field-label\" for=\"wpforms-4336-field_3\">Kurzbeschreibung<\/label><textarea id=\"wpforms-4336-field_3\" class=\"wpforms-field-medium\" name=\"wpforms[fields][3]\" aria-errormessage=\"wpforms-4336-field_3-error\" ><\/textarea><\/div><div id=\"wpforms-4336-field_6-container\" class=\"wpforms-field wpforms-field-checkbox\" data-field-id=\"6\"><fieldset><legend class=\"wpforms-field-label wpforms-label-hide\" aria-hidden=\"false\">Checkboxes <span class=\"wpforms-required-label\" aria-hidden=\"true\">*<\/span><\/legend><ul id=\"wpforms-4336-field_6\" class=\"wpforms-field-required\"><li class=\"choice-1 depth-1\"><input type=\"checkbox\" id=\"wpforms-4336-field_6_1\" name=\"wpforms[fields][6][]\" value=\"Ich stimme der Verarbeitung meiner Angaben zur Angebotserstellung zu.\" aria-errormessage=\"wpforms-4336-field_6_1-error\" aria-describedby=\"wpforms-4336-field_6-description\" required ><label class=\"wpforms-field-label-inline\" for=\"wpforms-4336-field_6_1\">Ich stimme der Verarbeitung meiner Angaben zur Angebotserstellung zu.<\/label><\/li><\/ul><div id=\"wpforms-4336-field_6-description\" class=\"wpforms-field-description\">Hinweise siehe Datenschutz.<\/div><\/fieldset><\/div><script>\n\t\t\t\t( function() {\n\t\t\t\t\tconst style = document.createElement( 'style' );\n\t\t\t\t\tstyle.appendChild( document.createTextNode( '#wpforms-4336-field_5-container { position: absolute !important; overflow: hidden !important; display: inline !important; height: 1px !important; width: 1px !important; z-index: -1000 !important; padding: 0 !important; } #wpforms-4336-field_5-container input { visibility: hidden; } #wpforms-conversational-form-page #wpforms-4336-field_5-container label { counter-increment: none; }' ) );\n\t\t\t\t\tdocument.head.appendChild( style );\n\t\t\t\t\tdocument.currentScript?.remove();\n\t\t\t\t} )();\n\t\t\t<\/script><\/div><!-- .wpforms-field-container --><div class=\"wpforms-submit-container\" ><input type=\"hidden\" name=\"wpforms[id]\" value=\"4336\"><input type=\"hidden\" name=\"page_title\" value=\"\"><input type=\"hidden\" name=\"page_url\" value=\"https:\/\/tps-elektronik.com\/es\/wp-json\/wp\/v2\/posts\/14631\"><input type=\"hidden\" name=\"url_referer\" value=\"\"><button type=\"submit\" name=\"wpforms[submit]\" id=\"wpforms-submit-4336\" class=\"wpforms-submit\" data-alt-text=\"Senden...\" data-submit-text=\"Anfrage senden\" aria-live=\"assertive\" value=\"wpforms-submit\">Anfrage senden<\/button><img decoding=\"async\" src=\"https:\/\/tps-elektronik.com\/wp-content\/plugins\/wpforms-lite\/assets\/images\/submit-spin.svg\" class=\"wpforms-submit-spinner\" style=\"display: none;\" width=\"26\" height=\"26\" alt=\"Cargando\"><\/div><\/form><\/div>  <!-- .wpforms-container -->","protected":false},"excerpt":{"rendered":"<p>F\u00fcr Systemintegratoren, Schaltschrankbauer und technisch orientierte Beschaffungsteams geht es bei der Auswahl eines Netzteils f\u00fcr ein automatisiertes Testsystem nicht nur um Spannungs\u2011 und Stromwerte. Es geht auch um Rack\u2011Dichte, Energieeffizienz, W\u00e4rmemanagement und darum, ob das System reale Lastbedingungen \u2014 wie das Laden und Entladen einer Batterie \u2014 ohne separate Instrumente simulieren kann. Wenn ein Testlabor\u2026 <a href=\"https:\/\/tps-elektronik.com\/es\/what-is-tps-high-power-bidirectional-programmable-power-supply-for-high-density-ate-systems-and-why-it-is-ideal-for-space-saving-and-energy-efficient-test-labs\/\">Read More &raquo;<\/a><\/p>\n","protected":false},"author":9,"featured_media":14772,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[19],"tags":[],"class_list":["post-14631","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-produkte"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.0 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>TPS Bidirectional Programmable Power Supply - TPS<\/title>\n<meta name=\"description\" content=\"TPS bidirectional programmable power supply mit 30\u202fkW in 4U f\u00fcr ATE. Regenerativ, autoranging und platzsparend f\u00fcr energieeffiziente Testlabore.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/tps-elektronik.com\/es\/what-is-tps-high-power-bidirectional-programmable-power-supply-for-high-density-ate-systems-and-why-it-is-ideal-for-space-saving-and-energy-efficient-test-labs\/\" \/>\n<meta property=\"og:locale\" content=\"es_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"TPS Bidirectional Programmable Power Supply - TPS\" \/>\n<meta property=\"og:description\" content=\"TPS bidirectional programmable power supply mit 30\u202fkW in 4U f\u00fcr ATE. Regenerativ, autoranging und platzsparend f\u00fcr energieeffiziente Testlabore.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/tps-elektronik.com\/es\/what-is-tps-high-power-bidirectional-programmable-power-supply-for-high-density-ate-systems-and-why-it-is-ideal-for-space-saving-and-energy-efficient-test-labs\/\" \/>\n<meta property=\"og:site_name\" content=\"TPS\" \/>\n<meta property=\"article:published_time\" content=\"2026-07-10T07:00:00+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/06\/0710-Programmable-Bidirectional-DC-Power-Supply-1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"700\" \/>\n\t<meta property=\"og:image:height\" content=\"394\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Tang Marcus\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Escrito por\" \/>\n\t<meta name=\"twitter:data1\" content=\"Tang Marcus\" \/>\n\t<meta name=\"twitter:label2\" content=\"Tiempo de lectura\" \/>\n\t<meta name=\"twitter:data2\" content=\"9 minutos\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/es\\\/what-is-tps-high-power-bidirectional-programmable-power-supply-for-high-density-ate-systems-and-why-it-is-ideal-for-space-saving-and-energy-efficient-test-labs\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/es\\\/what-is-tps-high-power-bidirectional-programmable-power-supply-for-high-density-ate-systems-and-why-it-is-ideal-for-space-saving-and-energy-efficient-test-labs\\\/\"},\"author\":{\"name\":\"Tang Marcus\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/es\\\/#\\\/schema\\\/person\\\/2c19fd053095d0c1ae253e8e62427b8c\"},\"headline\":\"Was ist das TPS Hochleistungs\u2011Bidirektionale Programmierbare DC\u2011Netzteil f\u00fcr High\u2011Density\u2011ATE\u2011Systeme und warum ist es ideal f\u00fcr platzsparende und energieeffiziente Testlabore?\",\"datePublished\":\"2026-07-10T07:00:00+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/es\\\/what-is-tps-high-power-bidirectional-programmable-power-supply-for-high-density-ate-systems-and-why-it-is-ideal-for-space-saving-and-energy-efficient-test-labs\\\/\"},\"wordCount\":1899,\"image\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/es\\\/what-is-tps-high-power-bidirectional-programmable-power-supply-for-high-density-ate-systems-and-why-it-is-ideal-for-space-saving-and-energy-efficient-test-labs\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/tps-elektronik.com\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/0710-Programmable-Bidirectional-DC-Power-Supply-1.jpg\",\"articleSection\":[\"Produkt\"],\"inLanguage\":\"es\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/es\\\/what-is-tps-high-power-bidirectional-programmable-power-supply-for-high-density-ate-systems-and-why-it-is-ideal-for-space-saving-and-energy-efficient-test-labs\\\/\",\"url\":\"https:\\\/\\\/tps-elektronik.com\\\/es\\\/what-is-tps-high-power-bidirectional-programmable-power-supply-for-high-density-ate-systems-and-why-it-is-ideal-for-space-saving-and-energy-efficient-test-labs\\\/\",\"name\":\"TPS Bidirectional Programmable Power Supply - TPS\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/es\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/es\\\/what-is-tps-high-power-bidirectional-programmable-power-supply-for-high-density-ate-systems-and-why-it-is-ideal-for-space-saving-and-energy-efficient-test-labs\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/es\\\/what-is-tps-high-power-bidirectional-programmable-power-supply-for-high-density-ate-systems-and-why-it-is-ideal-for-space-saving-and-energy-efficient-test-labs\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/tps-elektronik.com\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/0710-Programmable-Bidirectional-DC-Power-Supply-1.jpg\",\"datePublished\":\"2026-07-10T07:00:00+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/es\\\/#\\\/schema\\\/person\\\/2c19fd053095d0c1ae253e8e62427b8c\"},\"description\":\"TPS bidirectional programmable power supply mit 30\u202fkW in 4U f\u00fcr ATE. Regenerativ, autoranging und platzsparend f\u00fcr energieeffiziente Testlabore.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/es\\\/what-is-tps-high-power-bidirectional-programmable-power-supply-for-high-density-ate-systems-and-why-it-is-ideal-for-space-saving-and-energy-efficient-test-labs\\\/#breadcrumb\"},\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/tps-elektronik.com\\\/es\\\/what-is-tps-high-power-bidirectional-programmable-power-supply-for-high-density-ate-systems-and-why-it-is-ideal-for-space-saving-and-energy-efficient-test-labs\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/es\\\/what-is-tps-high-power-bidirectional-programmable-power-supply-for-high-density-ate-systems-and-why-it-is-ideal-for-space-saving-and-energy-efficient-test-labs\\\/#primaryimage\",\"url\":\"https:\\\/\\\/tps-elektronik.com\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/0710-Programmable-Bidirectional-DC-Power-Supply-1.jpg\",\"contentUrl\":\"https:\\\/\\\/tps-elektronik.com\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/0710-Programmable-Bidirectional-DC-Power-Supply-1.jpg\",\"width\":700,\"height\":394,\"caption\":\"bidirectional programmable power supply\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/es\\\/what-is-tps-high-power-bidirectional-programmable-power-supply-for-high-density-ate-systems-and-why-it-is-ideal-for-space-saving-and-energy-efficient-test-labs\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Startseite\",\"item\":\"https:\\\/\\\/tps-elektronik.com\\\/es\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Was ist das TPS Hochleistungs\u2011Bidirektionale Programmierbare DC\u2011Netzteil f\u00fcr High\u2011Density\u2011ATE\u2011Systeme und warum ist es ideal f\u00fcr platzsparende und energieeffiziente Testlabore?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/es\\\/#website\",\"url\":\"https:\\\/\\\/tps-elektronik.com\\\/es\\\/\",\"name\":\"TPS\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/tps-elektronik.com\\\/es\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"es\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/es\\\/#\\\/schema\\\/person\\\/2c19fd053095d0c1ae253e8e62427b8c\",\"name\":\"Tang Marcus\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"TPS Bidirectional Programmable Power Supply - TPS","description":"TPS bidirectional programmable power supply mit 30\u202fkW in 4U f\u00fcr ATE. Regenerativ, autoranging und platzsparend f\u00fcr energieeffiziente Testlabore.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/tps-elektronik.com\/es\/what-is-tps-high-power-bidirectional-programmable-power-supply-for-high-density-ate-systems-and-why-it-is-ideal-for-space-saving-and-energy-efficient-test-labs\/","og_locale":"es_ES","og_type":"article","og_title":"TPS Bidirectional Programmable Power Supply - TPS","og_description":"TPS bidirectional programmable power supply mit 30\u202fkW in 4U f\u00fcr ATE. Regenerativ, autoranging und platzsparend f\u00fcr energieeffiziente Testlabore.","og_url":"https:\/\/tps-elektronik.com\/es\/what-is-tps-high-power-bidirectional-programmable-power-supply-for-high-density-ate-systems-and-why-it-is-ideal-for-space-saving-and-energy-efficient-test-labs\/","og_site_name":"TPS","article_published_time":"2026-07-10T07:00:00+00:00","og_image":[{"width":700,"height":394,"url":"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/06\/0710-Programmable-Bidirectional-DC-Power-Supply-1.jpg","type":"image\/jpeg"}],"author":"Tang Marcus","twitter_card":"summary_large_image","twitter_misc":{"Escrito por":"Tang Marcus","Tiempo de lectura":"9 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/tps-elektronik.com\/es\/what-is-tps-high-power-bidirectional-programmable-power-supply-for-high-density-ate-systems-and-why-it-is-ideal-for-space-saving-and-energy-efficient-test-labs\/#article","isPartOf":{"@id":"https:\/\/tps-elektronik.com\/es\/what-is-tps-high-power-bidirectional-programmable-power-supply-for-high-density-ate-systems-and-why-it-is-ideal-for-space-saving-and-energy-efficient-test-labs\/"},"author":{"name":"Tang Marcus","@id":"https:\/\/tps-elektronik.com\/es\/#\/schema\/person\/2c19fd053095d0c1ae253e8e62427b8c"},"headline":"Was ist das TPS Hochleistungs\u2011Bidirektionale Programmierbare DC\u2011Netzteil f\u00fcr High\u2011Density\u2011ATE\u2011Systeme und warum ist es ideal f\u00fcr platzsparende und energieeffiziente Testlabore?","datePublished":"2026-07-10T07:00:00+00:00","mainEntityOfPage":{"@id":"https:\/\/tps-elektronik.com\/es\/what-is-tps-high-power-bidirectional-programmable-power-supply-for-high-density-ate-systems-and-why-it-is-ideal-for-space-saving-and-energy-efficient-test-labs\/"},"wordCount":1899,"image":{"@id":"https:\/\/tps-elektronik.com\/es\/what-is-tps-high-power-bidirectional-programmable-power-supply-for-high-density-ate-systems-and-why-it-is-ideal-for-space-saving-and-energy-efficient-test-labs\/#primaryimage"},"thumbnailUrl":"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/06\/0710-Programmable-Bidirectional-DC-Power-Supply-1.jpg","articleSection":["Produkt"],"inLanguage":"es"},{"@type":"WebPage","@id":"https:\/\/tps-elektronik.com\/es\/what-is-tps-high-power-bidirectional-programmable-power-supply-for-high-density-ate-systems-and-why-it-is-ideal-for-space-saving-and-energy-efficient-test-labs\/","url":"https:\/\/tps-elektronik.com\/es\/what-is-tps-high-power-bidirectional-programmable-power-supply-for-high-density-ate-systems-and-why-it-is-ideal-for-space-saving-and-energy-efficient-test-labs\/","name":"TPS Bidirectional Programmable Power Supply - TPS","isPartOf":{"@id":"https:\/\/tps-elektronik.com\/es\/#website"},"primaryImageOfPage":{"@id":"https:\/\/tps-elektronik.com\/es\/what-is-tps-high-power-bidirectional-programmable-power-supply-for-high-density-ate-systems-and-why-it-is-ideal-for-space-saving-and-energy-efficient-test-labs\/#primaryimage"},"image":{"@id":"https:\/\/tps-elektronik.com\/es\/what-is-tps-high-power-bidirectional-programmable-power-supply-for-high-density-ate-systems-and-why-it-is-ideal-for-space-saving-and-energy-efficient-test-labs\/#primaryimage"},"thumbnailUrl":"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/06\/0710-Programmable-Bidirectional-DC-Power-Supply-1.jpg","datePublished":"2026-07-10T07:00:00+00:00","author":{"@id":"https:\/\/tps-elektronik.com\/es\/#\/schema\/person\/2c19fd053095d0c1ae253e8e62427b8c"},"description":"TPS bidirectional programmable power supply mit 30\u202fkW in 4U f\u00fcr ATE. Regenerativ, autoranging und platzsparend f\u00fcr energieeffiziente Testlabore.","breadcrumb":{"@id":"https:\/\/tps-elektronik.com\/es\/what-is-tps-high-power-bidirectional-programmable-power-supply-for-high-density-ate-systems-and-why-it-is-ideal-for-space-saving-and-energy-efficient-test-labs\/#breadcrumb"},"inLanguage":"es","potentialAction":[{"@type":"ReadAction","target":["https:\/\/tps-elektronik.com\/es\/what-is-tps-high-power-bidirectional-programmable-power-supply-for-high-density-ate-systems-and-why-it-is-ideal-for-space-saving-and-energy-efficient-test-labs\/"]}]},{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/tps-elektronik.com\/es\/what-is-tps-high-power-bidirectional-programmable-power-supply-for-high-density-ate-systems-and-why-it-is-ideal-for-space-saving-and-energy-efficient-test-labs\/#primaryimage","url":"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/06\/0710-Programmable-Bidirectional-DC-Power-Supply-1.jpg","contentUrl":"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/06\/0710-Programmable-Bidirectional-DC-Power-Supply-1.jpg","width":700,"height":394,"caption":"bidirectional programmable power supply"},{"@type":"BreadcrumbList","@id":"https:\/\/tps-elektronik.com\/es\/what-is-tps-high-power-bidirectional-programmable-power-supply-for-high-density-ate-systems-and-why-it-is-ideal-for-space-saving-and-energy-efficient-test-labs\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Startseite","item":"https:\/\/tps-elektronik.com\/es\/"},{"@type":"ListItem","position":2,"name":"Was ist das TPS Hochleistungs\u2011Bidirektionale Programmierbare DC\u2011Netzteil f\u00fcr High\u2011Density\u2011ATE\u2011Systeme und warum ist es ideal f\u00fcr platzsparende und energieeffiziente Testlabore?"}]},{"@type":"WebSite","@id":"https:\/\/tps-elektronik.com\/es\/#website","url":"https:\/\/tps-elektronik.com\/es\/","name":"TPS","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/tps-elektronik.com\/es\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"es"},{"@type":"Person","@id":"https:\/\/tps-elektronik.com\/es\/#\/schema\/person\/2c19fd053095d0c1ae253e8e62427b8c","name":"Tang Marcus"}]}},"_links":{"self":[{"href":"https:\/\/tps-elektronik.com\/es\/wp-json\/wp\/v2\/posts\/14631","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/tps-elektronik.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/tps-elektronik.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/tps-elektronik.com\/es\/wp-json\/wp\/v2\/users\/9"}],"replies":[{"embeddable":true,"href":"https:\/\/tps-elektronik.com\/es\/wp-json\/wp\/v2\/comments?post=14631"}],"version-history":[{"count":4,"href":"https:\/\/tps-elektronik.com\/es\/wp-json\/wp\/v2\/posts\/14631\/revisions"}],"predecessor-version":[{"id":14791,"href":"https:\/\/tps-elektronik.com\/es\/wp-json\/wp\/v2\/posts\/14631\/revisions\/14791"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/tps-elektronik.com\/es\/wp-json\/wp\/v2\/media\/14772"}],"wp:attachment":[{"href":"https:\/\/tps-elektronik.com\/es\/wp-json\/wp\/v2\/media?parent=14631"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/tps-elektronik.com\/es\/wp-json\/wp\/v2\/categories?post=14631"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/tps-elektronik.com\/es\/wp-json\/wp\/v2\/tags?post=14631"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}