{"id":7713,"date":"2026-02-05T09:30:00","date_gmt":"2026-02-05T08:30:00","guid":{"rendered":"https:\/\/tps-elektronik.com\/?p=7713"},"modified":"2026-02-17T15:44:36","modified_gmt":"2026-02-17T14:44:36","slug":"esd-safe-adjustable-ac-transformer","status":"publish","type":"post","link":"https:\/\/tps-elektronik.com\/en\/esd-safe-adjustable-ac-transformer\/","title":{"rendered":"Adjustable AC Isolation Transformers for ESD-Safe Zones"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\">Precision Voltage Control with Galvanic Isolation<\/h2>\n\n\n\n<p>In electronics manufacturing, research, and repair environments, <a href=\"https:\/\/en.wikipedia.org\/wiki\/Electrostatic_discharge\" target=\"_blank\" rel=\"noopener noreferrer nofollow\">Electrostatic Discharge<\/a> (ESD) represents a continuous risk to sensitive components. Even minor electrostatic events can damage assemblies, cause latent defects, or affect measurement accuracy.<\/p>\n\n\n\n<p>Effective ESD protection therefore extends beyond wrist straps and grounded work surfaces. It also includes the selection of appropriate power sources. <a href=\"https:\/\/www.shop-tps.com\/shop\/category\/esd-workshop-adjustable-ac-transformer-173\" target=\"_blank\" rel=\"noopener noreferrer nofollow\">Adjustable AC isolation transformers<\/a> are specifically suited for applications where variable voltage and electrical isolation are required within ESD-controlled areas.<\/p>\n\n\n\n<p>This article explains the technical background, key selection criteria, and typical applications of adjustable AC isolation transformers, using the <a href=\"https:\/\/www.shop-tps.com\/de\/shop\/tps-ait1500300-21916?category=173#attr=\" target=\"_blank\" rel=\"noopener noreferrer nofollow\">TPS-AIT1500300<\/a> as a practical example.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Key Takeaways<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Standard variable autotransformers (variacs) do not provide galvanic isolation and may introduce ground loop risks in ESD environments.<\/li>\n\n\n\n<li>An adjustable isolation transformer combines variable AC output with primary\u2013secondary isolation.<\/li>\n\n\n\n<li>Galvanic isolation helps reduce unwanted common-mode effects between equipment and the ESD ground system.<\/li>\n\n\n\n<li>Integrated metering and overcurrent protection support controlled testing procedures.<\/li>\n\n\n\n<li>Typical selection criteria include isolation rating, output range, power capacity, protection mechanisms, and mechanical design.<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1920\" height=\"1280\" src=\"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/01\/TPS-AIT1500300-2.png\" alt=\"Clear front view of the TPS-AIT1500300 adjustable isolation transformer.\" class=\"wp-image-7718\" srcset=\"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/01\/TPS-AIT1500300-2.png 1920w, https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/01\/TPS-AIT1500300-2-600x400.png 600w\" sizes=\"auto, (max-width: 1920px) 100vw, 1920px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Why Standard Variacs Are Not Ideal for ESD Zones<\/h2>\n\n\n\n<p>A conventional variac is a variable autotransformer with a single winding and movable contact. It enables efficient and continuous voltage adjustment. However, the input and output share a common electrical reference.<\/p>\n\n\n\n<p>In ESD-controlled areas, this design can create challenges:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>No galvanic isolation between mains and output<\/li>\n\n\n\n<li>Increased likelihood of ground loop formation<\/li>\n\n\n\n<li>Potential influence on sensitive measurement setups<\/li>\n<\/ul>\n\n\n\n<p>For basic voltage adjustment tasks, a variac may be sufficient. For ESD-sensitive testing, however, isolation is typically required.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">From Autotransformer to Adjustable Isolation Transformer<\/h2>\n\n\n\n<p>An isolation transformer uses separate primary and secondary windings. This design provides galvanic isolation, meaning there is no direct conductive path between input and output.<\/p>\n\n\n\n<p>An adjustable AC isolation transformer integrates:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>A true isolation transformer stage<\/li>\n\n\n\n<li>A variable output mechanism<\/li>\n\n\n\n<li>Protection and monitoring functions<\/li>\n<\/ul>\n\n\n\n<p>The result is a variable AC power source that maintains electrical separation from the mains supply. This configuration supports controlled testing within grounded ESD infrastructures.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Product Example: TPS-AIT1500300 Adjustable Isolation Transformer<\/h2>\n\n\n\n<p>The <a href=\"https:\/\/tps-elektronik.com\/en\/\" type=\"page\" id=\"1008\">TPS<\/a>-AIT1500300 is a bench-top adjustable isolation transformer designed for laboratory, workshop, and quality assurance applications.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Key Technical Data<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Parameter<\/th><th>Specification<\/th><th>Practical Relevance<\/th><\/tr><\/thead><tbody><tr><td><strong>Input<\/strong><\/td><td>230 VAC, 48\u201362 Hz, 6 A<\/td><td>Suitable for standard European mains<\/td><\/tr><tr><td><strong>Output (Adjustable)<\/strong><\/td><td>0 \u2013 300 VAC, 4.5A, 1500W (1.5KW)<\/td><td>Wide adjustable range for functional and stress testing<\/td><\/tr><tr><td><strong>Over Current Protection<\/strong><\/td><td>5A air circuit breaker<\/td><td>Protection for transformer and DUT<\/td><\/tr><tr><td><strong>Metering<\/strong><\/td><td>Analog voltmeter &amp; ammeter<\/td><td>Direct visual monitoring of voltage and current<\/td><\/tr><tr><td><strong>Isolation Rating<\/strong><\/td><td>3000 VAC (primary\u2013secondary)<\/td><td>Reinforced separation between mains and output<\/td><\/tr><tr><td><strong>Cooling<\/strong><\/td><td>Convection<\/td><td>Low-noise operation, reduced maintenance<\/td><\/tr><tr><td><strong>Dimensions \/ Weight<\/strong><\/td><td>301 \u00d7 276 \u00d7 183 mm \/ 21 kg<\/td><td>Stable bench-top installation<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p>The front panel layout includes a large voltage adjustment knob, integrated analog meters, and output receptacles for controlled operation.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1920\" height=\"1280\" src=\"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/01\/Adjustable-AC-Transformer-20260120-2.jpg\" alt=\"The TPS-AIT1500300 is placed on a workbench covered with a gray anti-static mat.\" class=\"wp-image-7721\" srcset=\"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/01\/Adjustable-AC-Transformer-20260120-2.jpg 1920w, https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/01\/Adjustable-AC-Transformer-20260120-2-600x400.jpg 600w\" sizes=\"auto, (max-width: 1920px) 100vw, 1920px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Design Characteristics<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Convection cooling<\/strong> avoids fan noise and reduces dust intake.<\/li>\n\n\n\n<li><strong>IP20 enclosure<\/strong> provides basic protection against contact with live parts.<\/li>\n\n\n\n<li><strong>Robust mechanical housing<\/strong> supports regular laboratory or workshop use.<\/li>\n<\/ul>\n\n\n\n<p>Operational suitability should always be assessed according to the specific environmental conditions of the installation site.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Typical Applications<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">1. Electronic Repair and Diagnostics<\/h3>\n\n\n\n<p>Technicians can gradually increase output voltage from 0 VAC while monitoring current consumption. This approach supports controlled fault detection, for example when checking for short circuits or abnormal inrush behavior.<\/p>\n\n\n\n<p>Isolation reduces interaction between the device under test (DUT) and the building\u2019s grounding system.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">2. Research and Development (R&amp;D)<\/h3>\n\n\n\n<p>In R&amp;D environments, adjustable isolation transformers allow:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Functional verification across different mains voltage levels<\/li>\n\n\n\n<li>Controlled undervoltage and overvoltage testing<\/li>\n\n\n\n<li>Reduced ground-related measurement disturbances when using oscilloscopes or analyzers<\/li>\n<\/ul>\n\n\n\n<p>They are frequently used in prototype validation and design verification phases.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">3. Quality Assurance and Production Testing<\/h3>\n\n\n\n<p>For QA processes, the adjustable output enables:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Line regulation testing<\/li>\n\n\n\n<li>Functional validation at voltage extremes<\/li>\n\n\n\n<li>Controlled stress testing within defined limits<\/li>\n<\/ul>\n\n\n\n<p>The integrated circuit breaker supports automated interruption in case of overload or device failure.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">4. Education and Technical Training<\/h3>\n\n\n\n<p>In technical education, adjustable isolation transformers provide a practical platform to demonstrate:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Transformer principles<\/li>\n\n\n\n<li>Voltage\u2013current relationships<\/li>\n\n\n\n<li>Effects of input variation on system behavior<\/li>\n\n\n\n<li>Basic ESD protection concepts<\/li>\n<\/ul>\n\n\n\n<p>Analog meters offer direct visual feedback, which can be beneficial in instructional environments.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">5. Industrial and Automotive Workshops<\/h3>\n\n\n\n<p>Industrial control systems, PLCs, and automotive ECUs often require controlled voltage simulation during diagnostics. Adjustable isolation transformers can be used to reproduce defined voltage conditions in a workshop environment.<\/p>\n\n\n\n<p>Application limits should always be verified against the technical specifications of both the transformer and the DUT.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Integration into an ESD Workstation<\/h2>\n\n\n\n<p>Correct grounding is essential.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>The transformer chassis must be connected to protective earth (PE).<\/li>\n\n\n\n<li>The ESD work surface and wrist straps connect to the ESD common point ground (CPG).<\/li>\n\n\n\n<li>The CPG is bonded to protective earth in a defined single-point configuration.<\/li>\n<\/ul>\n\n\n\n<p>This grounding concept ensures that all conductive elements remain at a common reference potential while the isolation barrier separates the DUT from the mains supply.<\/p>\n\n\n\n<p>Implementation should follow applicable ESD control standards and internal compliance procedures.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1920\" height=\"1080\" src=\"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/01\/Adjustable-AC-Transformer-20260120-1.jpg\" alt=\"A simplified two-dimensional block diagram illustrating the grounding connection.\" class=\"wp-image-7724\"\/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Conclusion<\/h2>\n\n\n\n<p>Adjustable AC isolation transformers provide a combination of variable voltage control and galvanic isolation. In ESD-controlled environments, this configuration can support safer testing procedures compared to non-isolated autotransformers.<\/p>\n\n\n\n<p>The TPS-AIT1500300 represents a practical example of such a solution, offering:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>0\u2013300 VAC adjustable output<\/li>\n\n\n\n<li>1500 W nominal capacity<\/li>\n\n\n\n<li>Integrated metering and overcurrent protection<\/li>\n\n\n\n<li>Primary\u2013secondary isolation<\/li>\n<\/ul>\n\n\n\n<p>For laboratories, repair facilities, training centers, and quality assurance stations, an adjustable isolation transformer can be a suitable tool where controlled voltage variation and electrical separation from the mains are required.<\/p>\n\n\n\n<p>Selection should always be based on application requirements, power demand, and applicable safety standards.<\/p>\n\n\n<style id=\"wpforms-css-vars-4659-block-7c0d8ecf-8838-4078-837a-0ad686438ab8\">\n\t\t\t\t#wpforms-4659.wpforms-block-7c0d8ecf-8838-4078-837a-0ad686438ab8 {\n\t\t\t\t--wpforms-field-size-input-height: 43px;\n--wpforms-field-size-input-spacing: 15px;\n--wpforms-field-size-font-size: 16px;\n--wpforms-field-size-line-height: 19px;\n--wpforms-field-size-padding-h: 14px;\n--wpforms-field-size-checkbox-size: 16px;\n--wpforms-field-size-sublabel-spacing: 5px;\n--wpforms-field-size-icon-size: 1;\n--wpforms-label-size-font-size: 16px;\n--wpforms-label-size-line-height: 19px;\n--wpforms-label-size-sublabel-font-size: 14px;\n--wpforms-label-size-sublabel-line-height: 17px;\n--wpforms-button-size-font-size: 17px;\n--wpforms-button-size-height: 41px;\n--wpforms-button-size-padding-h: 15px;\n--wpforms-button-size-margin-top: 10px;\n\t\t\t}\n\t\t\t<\/style><div class=\"wpforms-container wpforms-container-full wpforms-block wpforms-block-7c0d8ecf-8838-4078-837a-0ad686438ab8 wpforms-render-modern\" id=\"wpforms-4659\"><form id=\"wpforms-form-4659\" class=\"wpforms-validate wpforms-form wpforms-ajax-form\" data-formid=\"4659\" method=\"post\" enctype=\"multipart\/form-data\" action=\"\/en\/wp-json\/wp\/v2\/posts\/7713\" data-token=\"26ffcfe7f0895f314739bcdb06babf63\" data-token-time=\"1776076051\"><noscript class=\"wpforms-error-noscript\">Please enable JavaScript in your browser to complete this form.<\/noscript><div id=\"wpforms-error-noscript\" style=\"display: none;\">Please enable JavaScript in your browser to complete this form.<\/div><div class=\"wpforms-field-container\"><div id=\"wpforms-4659-field_1-container\" class=\"wpforms-field wpforms-field-name\" data-field-id=\"1\"><fieldset><legend class=\"wpforms-field-label\">Name <span class=\"wpforms-required-label\" aria-hidden=\"true\">*<\/span><\/legend><div class=\"wpforms-field-row wpforms-field-large\"><div class=\"wpforms-field-row-block wpforms-first wpforms-one-half\"><input type=\"text\" id=\"wpforms-4659-field_1\" class=\"wpforms-field-name-first wpforms-field-required\" name=\"wpforms[fields][1][first]\" aria-errormessage=\"wpforms-4659-field_1-error\" required><label for=\"wpforms-4659-field_1\" class=\"wpforms-field-sublabel after\">First<\/label><\/div><div class=\"wpforms-field-row-block wpforms-one-half\"><input type=\"text\" id=\"wpforms-4659-field_1-last\" class=\"wpforms-field-name-last wpforms-field-required\" name=\"wpforms[fields][1][last]\" aria-errormessage=\"wpforms-4659-field_1-last-error\" required><label for=\"wpforms-4659-field_1-last\" class=\"wpforms-field-sublabel after\">Last<\/label><\/div><\/div><\/fieldset><\/div><div id=\"wpforms-4659-field_4-container\" class=\"wpforms-field wpforms-field-text\" data-field-id=\"4\"><label class=\"wpforms-field-label\" for=\"wpforms-4659-field_4\">Company <span class=\"wpforms-required-label\" aria-hidden=\"true\">*<\/span><\/label><input type=\"text\" id=\"wpforms-4659-field_4\" class=\"wpforms-field-large wpforms-field-required\" name=\"wpforms[fields][4]\" aria-errormessage=\"wpforms-4659-field_4-error\" required><\/div><div id=\"wpforms-4659-field_2-container\" class=\"wpforms-field wpforms-field-email\" data-field-id=\"2\"><label class=\"wpforms-field-label\" for=\"wpforms-4659-field_2\">Email <span class=\"wpforms-required-label\" aria-hidden=\"true\">*<\/span><\/label><input type=\"email\" id=\"wpforms-4659-field_2\" class=\"wpforms-field-large wpforms-field-required\" name=\"wpforms[fields][2]\" spellcheck=\"false\" aria-errormessage=\"wpforms-4659-field_2-error\" required><\/div><div id=\"wpforms-4659-field_3-container\" class=\"wpforms-field wpforms-field-textarea\" data-field-id=\"3\"><label class=\"wpforms-field-label\" for=\"wpforms-4659-field_3\">Comment or Message<\/label><textarea id=\"wpforms-4659-field_3\" class=\"wpforms-field-medium\" name=\"wpforms[fields][3]\" aria-errormessage=\"wpforms-4659-field_3-error\" ><\/textarea><\/div>\t\t<div id=\"wpforms-4659-field_5-container\"\n\t\t\tclass=\"wpforms-field wpforms-field-text\"\n\t\t\tdata-field-type=\"text\"\n\t\t\tdata-field-id=\"5\"\n\t\t\t>\n\t\t\t<label class=\"wpforms-field-label\" for=\"wpforms-4659-field_5\" >Message Checkbox Name<\/label>\n\t\t\t<input type=\"text\" id=\"wpforms-4659-field_5\" class=\"wpforms-field-medium\" name=\"wpforms[fields][5]\" >\n\t\t<\/div>\n\t\t<div id=\"wpforms-4659-field_6-container\" class=\"wpforms-field wpforms-field-checkbox\" data-field-id=\"6\"><fieldset><legend class=\"wpforms-field-label wpforms-label-hide\" aria-hidden=\"false\">Checkbox <span class=\"wpforms-required-label\" aria-hidden=\"true\">*<\/span><\/legend><ul id=\"wpforms-4659-field_6\" class=\"wpforms-field-required\"><li class=\"choice-1 depth-1 wpforms-selected\"><input type=\"checkbox\" id=\"wpforms-4659-field_6_1\" name=\"wpforms[fields][6][]\" value=\"I agree to the processing of my information for the purpose of creating a quote.\" aria-errormessage=\"wpforms-4659-field_6_1-error\" aria-describedby=\"wpforms-4659-field_6-description\" required  checked='checked'><label class=\"wpforms-field-label-inline\" for=\"wpforms-4659-field_6_1\">I agree to the processing of my information for the purpose of creating a quote.<\/label><\/li><\/ul><div id=\"wpforms-4659-field_6-description\" class=\"wpforms-field-description\">For information see Privacy.<\/div><\/fieldset><\/div><script>\n\t\t\t\t( function() {\n\t\t\t\t\tconst style = document.createElement( 'style' );\n\t\t\t\t\tstyle.appendChild( document.createTextNode( '#wpforms-4659-field_5-container { position: absolute !important; overflow: hidden !important; display: inline !important; height: 1px !important; width: 1px !important; z-index: -1000 !important; padding: 0 !important; } #wpforms-4659-field_5-container input { visibility: hidden; } #wpforms-conversational-form-page #wpforms-4659-field_5-container label { counter-increment: none; }' ) );\n\t\t\t\t\tdocument.head.appendChild( style );\n\t\t\t\t\tdocument.currentScript?.remove();\n\t\t\t\t} )();\n\t\t\t<\/script><\/div><!-- .wpforms-field-container --><div class=\"wpforms-submit-container\" ><input type=\"hidden\" name=\"wpforms[id]\" value=\"4659\"><input type=\"hidden\" name=\"page_title\" value=\"\"><input type=\"hidden\" name=\"page_url\" value=\"https:\/\/tps-elektronik.com\/en\/wp-json\/wp\/v2\/posts\/7713\"><input type=\"hidden\" name=\"url_referer\" value=\"\"><button type=\"submit\" name=\"wpforms[submit]\" id=\"wpforms-submit-4659\" class=\"wpforms-submit\" data-alt-text=\"Sending...\" data-submit-text=\"Submit\" aria-live=\"assertive\" value=\"wpforms-submit\">Submit<\/button><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/tps-elektronik.com\/wp-content\/plugins\/wpforms-lite\/assets\/images\/submit-spin.svg\" class=\"wpforms-submit-spinner\" style=\"display: none;\" width=\"26\" height=\"26\" alt=\"Loading\"><\/div><\/form><\/div>  <!-- .wpforms-container -->","protected":false},"excerpt":{"rendered":"<p>Adjustable AC isolation transformers combine variable voltage control with galvanic isolation. This article explains their role in ESD-safe laboratories, repair environments, and quality assurance testing, including key selection criteria and a practical example with the TPS-AIT1500300.<\/p>\n","protected":false},"author":7,"featured_media":7721,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[53],"tags":[],"class_list":["post-7713","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-production"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Adjustable AC Isolation Transformers for ESD-Safe Workstations<\/title>\n<meta name=\"description\" content=\"Learn how adjustable AC isolation transformers support safe voltage control in ESD-safe labs, R&amp;D, repair, and QA applications.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/tps-elektronik.com\/en\/esd-safe-adjustable-ac-transformer\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Adjustable AC Isolation Transformers for ESD-Safe Workstations\" \/>\n<meta property=\"og:description\" content=\"Learn how adjustable AC isolation transformers support safe voltage control in ESD-safe labs, R&amp;D, repair, and QA applications.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/tps-elektronik.com\/en\/esd-safe-adjustable-ac-transformer\/\" \/>\n<meta property=\"og:site_name\" content=\"TPS\" \/>\n<meta property=\"article:published_time\" content=\"2026-02-05T08:30:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-02-17T14:44:36+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/01\/Adjustable-AC-Transformer-20260120-2.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1920\" \/>\n\t<meta property=\"og:image:height\" content=\"1280\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Kael Yuan\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Kael Yuan\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/esd-safe-adjustable-ac-transformer\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/esd-safe-adjustable-ac-transformer\\\/\"},\"author\":{\"name\":\"Kael Yuan\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/#\\\/schema\\\/person\\\/a09d32c7af89d4e26b0907097a8777c0\"},\"headline\":\"Adjustable AC Isolation Transformers for ESD-Safe Zones\",\"datePublished\":\"2026-02-05T08:30:00+00:00\",\"dateModified\":\"2026-02-17T14:44:36+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/esd-safe-adjustable-ac-transformer\\\/\"},\"wordCount\":917,\"image\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/esd-safe-adjustable-ac-transformer\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/tps-elektronik.com\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/Adjustable-AC-Transformer-20260120-2.jpg\",\"articleSection\":[\"Product\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/esd-safe-adjustable-ac-transformer\\\/\",\"url\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/esd-safe-adjustable-ac-transformer\\\/\",\"name\":\"Adjustable AC Isolation Transformers for ESD-Safe Workstations\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/esd-safe-adjustable-ac-transformer\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/esd-safe-adjustable-ac-transformer\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/tps-elektronik.com\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/Adjustable-AC-Transformer-20260120-2.jpg\",\"datePublished\":\"2026-02-05T08:30:00+00:00\",\"dateModified\":\"2026-02-17T14:44:36+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/#\\\/schema\\\/person\\\/a09d32c7af89d4e26b0907097a8777c0\"},\"description\":\"Learn how adjustable AC isolation transformers support safe voltage control in ESD-safe labs, R&D, repair, and QA applications.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/esd-safe-adjustable-ac-transformer\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/esd-safe-adjustable-ac-transformer\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/esd-safe-adjustable-ac-transformer\\\/#primaryimage\",\"url\":\"https:\\\/\\\/tps-elektronik.com\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/Adjustable-AC-Transformer-20260120-2.jpg\",\"contentUrl\":\"https:\\\/\\\/tps-elektronik.com\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/Adjustable-AC-Transformer-20260120-2.jpg\",\"width\":1920,\"height\":1280},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/esd-safe-adjustable-ac-transformer\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Startseite\",\"item\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Adjustable AC Isolation Transformers for ESD-Safe Zones\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/\",\"name\":\"TPS\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/#\\\/schema\\\/person\\\/a09d32c7af89d4e26b0907097a8777c0\",\"name\":\"Kael Yuan\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Adjustable AC Isolation Transformers for ESD-Safe Workstations","description":"Learn how adjustable AC isolation transformers support safe voltage control in ESD-safe labs, R&D, repair, and QA applications.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/tps-elektronik.com\/en\/esd-safe-adjustable-ac-transformer\/","og_locale":"en_US","og_type":"article","og_title":"Adjustable AC Isolation Transformers for ESD-Safe Workstations","og_description":"Learn how adjustable AC isolation transformers support safe voltage control in ESD-safe labs, R&D, repair, and QA applications.","og_url":"https:\/\/tps-elektronik.com\/en\/esd-safe-adjustable-ac-transformer\/","og_site_name":"TPS","article_published_time":"2026-02-05T08:30:00+00:00","article_modified_time":"2026-02-17T14:44:36+00:00","og_image":[{"width":1920,"height":1280,"url":"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/01\/Adjustable-AC-Transformer-20260120-2.jpg","type":"image\/jpeg"}],"author":"Kael Yuan","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Kael Yuan","Est. reading time":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/tps-elektronik.com\/en\/esd-safe-adjustable-ac-transformer\/#article","isPartOf":{"@id":"https:\/\/tps-elektronik.com\/en\/esd-safe-adjustable-ac-transformer\/"},"author":{"name":"Kael Yuan","@id":"https:\/\/tps-elektronik.com\/en\/#\/schema\/person\/a09d32c7af89d4e26b0907097a8777c0"},"headline":"Adjustable AC Isolation Transformers for ESD-Safe Zones","datePublished":"2026-02-05T08:30:00+00:00","dateModified":"2026-02-17T14:44:36+00:00","mainEntityOfPage":{"@id":"https:\/\/tps-elektronik.com\/en\/esd-safe-adjustable-ac-transformer\/"},"wordCount":917,"image":{"@id":"https:\/\/tps-elektronik.com\/en\/esd-safe-adjustable-ac-transformer\/#primaryimage"},"thumbnailUrl":"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/01\/Adjustable-AC-Transformer-20260120-2.jpg","articleSection":["Product"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/tps-elektronik.com\/en\/esd-safe-adjustable-ac-transformer\/","url":"https:\/\/tps-elektronik.com\/en\/esd-safe-adjustable-ac-transformer\/","name":"Adjustable AC Isolation Transformers for ESD-Safe Workstations","isPartOf":{"@id":"https:\/\/tps-elektronik.com\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/tps-elektronik.com\/en\/esd-safe-adjustable-ac-transformer\/#primaryimage"},"image":{"@id":"https:\/\/tps-elektronik.com\/en\/esd-safe-adjustable-ac-transformer\/#primaryimage"},"thumbnailUrl":"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/01\/Adjustable-AC-Transformer-20260120-2.jpg","datePublished":"2026-02-05T08:30:00+00:00","dateModified":"2026-02-17T14:44:36+00:00","author":{"@id":"https:\/\/tps-elektronik.com\/en\/#\/schema\/person\/a09d32c7af89d4e26b0907097a8777c0"},"description":"Learn how adjustable AC isolation transformers support safe voltage control in ESD-safe labs, R&D, repair, and QA applications.","breadcrumb":{"@id":"https:\/\/tps-elektronik.com\/en\/esd-safe-adjustable-ac-transformer\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/tps-elektronik.com\/en\/esd-safe-adjustable-ac-transformer\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/tps-elektronik.com\/en\/esd-safe-adjustable-ac-transformer\/#primaryimage","url":"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/01\/Adjustable-AC-Transformer-20260120-2.jpg","contentUrl":"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/01\/Adjustable-AC-Transformer-20260120-2.jpg","width":1920,"height":1280},{"@type":"BreadcrumbList","@id":"https:\/\/tps-elektronik.com\/en\/esd-safe-adjustable-ac-transformer\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Startseite","item":"https:\/\/tps-elektronik.com\/en\/"},{"@type":"ListItem","position":2,"name":"Adjustable AC Isolation Transformers for ESD-Safe Zones"}]},{"@type":"WebSite","@id":"https:\/\/tps-elektronik.com\/en\/#website","url":"https:\/\/tps-elektronik.com\/en\/","name":"TPS","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/tps-elektronik.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/tps-elektronik.com\/en\/#\/schema\/person\/a09d32c7af89d4e26b0907097a8777c0","name":"Kael Yuan"}]}},"_links":{"self":[{"href":"https:\/\/tps-elektronik.com\/en\/wp-json\/wp\/v2\/posts\/7713","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/tps-elektronik.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/tps-elektronik.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/tps-elektronik.com\/en\/wp-json\/wp\/v2\/users\/7"}],"replies":[{"embeddable":true,"href":"https:\/\/tps-elektronik.com\/en\/wp-json\/wp\/v2\/comments?post=7713"}],"version-history":[{"count":3,"href":"https:\/\/tps-elektronik.com\/en\/wp-json\/wp\/v2\/posts\/7713\/revisions"}],"predecessor-version":[{"id":8189,"href":"https:\/\/tps-elektronik.com\/en\/wp-json\/wp\/v2\/posts\/7713\/revisions\/8189"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/tps-elektronik.com\/en\/wp-json\/wp\/v2\/media\/7721"}],"wp:attachment":[{"href":"https:\/\/tps-elektronik.com\/en\/wp-json\/wp\/v2\/media?parent=7713"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/tps-elektronik.com\/en\/wp-json\/wp\/v2\/categories?post=7713"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/tps-elektronik.com\/en\/wp-json\/wp\/v2\/tags?post=7713"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}