{"id":19385,"date":"2026-11-20T01:52:50","date_gmt":"2026-11-20T00:52:50","guid":{"rendered":"https:\/\/tps-elektronik.com\/?p=19385"},"modified":"2026-11-20T01:52:56","modified_gmt":"2026-11-20T00:52:56","slug":"how-to-set-up-a-flexible-mobile-esd-repair-station-for-smartphone-and-electronics-rework-with-tps-height-adjustable-workstations","status":"publish","type":"post","link":"https:\/\/tps-elektronik.com\/en\/how-to-set-up-a-flexible-mobile-esd-repair-station-for-smartphone-and-electronics-rework-with-tps-height-adjustable-workstations\/","title":{"rendered":"How to Set Up a Flexible Mobile ESD Repair Station for Smartphone and Electronics Rework With TPS Height-Adjustable Workstations?"},"content":{"rendered":"<article class=\"product-blog\" lang=\"en\"><header>\n<p>For system integrators, panel builders, and engineering-driven procurement teams, setting up an ESD repair station for smartphone and electronics rework is not only about buying a bench.<\/p>\n<p>It also involves the grounding architecture, the surface resistivity of the worktop, the wrist strap and common ground point, the accessory set that makes the bench usable for board-level rework, and\u2014if the station has to move between service desks, production cells, or customer sites\u2014whether the bench can be relocated without breaking the ESD path.<\/p>\n<p>The <a href=\"https:\/\/www.shop-tps.com\/shop\/category\/esd-workshop-esd-table-154\" target=\"_blank\" rel=\"noopener noreferrer nofollow\"><strong>TPS Fixed-1260 ESD Workstation<\/strong><\/a> is a fixed-structure, industrial-grade ESD workbench with a <strong>25 mm ESD (HPL) laminated top<\/strong>, <strong>1220 \u00d7 600 \u00d7 760 mm<\/strong> dimensions, <strong>500 kg uniform static load<\/strong> capacity, and compliance with <strong>IEC 61340-5-1:2016<\/strong> across 10\u201360% relative humidity. It does not have castors or a height-adjustment mechanism as standard. This article explains how to use it as the core of a flexible rework station, what has to be added to make it relocatable, and where a different configuration is the correct choice.<\/p>\n<p><a class=\"cta-primary\" href=\"https:\/\/www.shop-tps.com\/shop\/category\/esd-workshop-esd-table-154\" target=\"_blank\" rel=\"noopener noreferrer nofollow\">View the TPS ESD workstation range \u2192<\/a><\/p>\n<\/header><nav class=\"toc\" aria-label=\"Table of Contents\">\n<h2 id=\"toc-en\">Table of Contents<\/h2>\n<ol>\n<li><a href=\"#en-what-mobile-requires\">What a mobile ESD repair station actually requires<\/a>\n<ol>\n<li><a href=\"#en-esd-principles\">The three ESD control elements<\/a><\/li>\n<li><a href=\"#en-mobility-vs-esd\">Why mobility and ESD control conflict\u2014and how to resolve it<\/a><\/li>\n<\/ol>\n<\/li>\n<li><a href=\"#en-fixed1260\">What the TPS Fixed-1260 provides as the bench platform<\/a>\n<ol>\n<li><a href=\"#en-specs\">Dimensions, load, and worktop<\/a><\/li>\n<li><a href=\"#en-compliance\">IEC 61340-5-1 compliance and humidity range<\/a><\/li>\n<\/ol>\n<\/li>\n<li><a href=\"#en-configuration\">Configuring the bench for smartphone and board-level rework<\/a>\n<ol>\n<li><a href=\"#en-grounding\">Grounding and verification points<\/a><\/li>\n<li><a href=\"#en-accessories\">Accessory set for rework<\/a><\/li>\n<li><a href=\"#en-relocation\">Relocation options for a fixed frame<\/a><\/li>\n<\/ol>\n<\/li>\n<li><a href=\"#en-daily-checks\">Daily and periodic verification<\/a><\/li>\n<li><a href=\"#en-specs\">Product specifications<\/a><\/li>\n<li><a href=\"#en-rfq\">RFQ checklist<\/a><\/li>\n<li><a href=\"#en-faq\">FAQ<\/a><\/li>\n<\/ol>\n<\/nav>\n<section id=\"en-what-mobile-requires\">\n<h2>1. What a mobile ESD repair station actually requires<\/h2>\n<p>A \u201cmobile ESD workstation\u201d is a rework bench that can be moved between locations while maintaining a valid ESD control path. The word \u201cmobile\u201d changes the mechanical requirements; it does not change the electrical ones. The bench must still provide a grounded, static-dissipative work surface, a personnel grounding point, and a common ground reference that remains connected after the move.<\/p>\n<h3 id=\"en-esd-principles\">1.1 The three ESD control elements<\/h3>\n<p>IEC 61340-5-1 defines the ESD control program requirements. At the workstation level, three elements must be in place:<\/p>\n<ul>\n<li><strong>A static-dissipative work surface<\/strong> connected to a groundable point, so that charges on the worktop and on the parts placed on it drain to earth in a controlled way.<\/li>\n<li><strong>A personnel grounding path<\/strong>, typically a wrist strap with a 1 M\u03a9 resistor, connected to the same common ground point as the worktop.<\/li>\n<li><strong>A common ground connection to protective earth<\/strong>, with the ground cords and the earth bond verified at a defined interval.<\/li>\n<\/ul>\n<p>If any of the three is missing or intermittent, the station is not an ESD station\u2014it is a bench with an antistatic mat on it. The distinction matters for procurement because the audit evidence is the verification record, not the product label.<\/p>\n<h3 id=\"en-mobility-vs-esd\">1.2 Why mobility and ESD control conflict\u2014and how to resolve it<\/h3>\n<p>Mobility introduces three risks. First, the ground cord can left disconnected after a move, or the connection can strained by repeated handling. Second, a castor-mounted bench can lose its earth bond if the castors isolate the frame from the floor and the ground cord is the only path\u2014so the cord becomes a single point of failure. Third, vibration and floor unevenness can loosen the groundable point hardware over time.<\/p>\n<p>The resolution is not to avoid mobility, but to design the ground path so that it verified after every move. A common approach is a dedicated ground cord with a visible connection point and a short verification procedure (wrist strap test plus worktop-to-earth resistance check) performed at the start of each shift or after each relocation. This is the same discipline that IEC 61340-5-1 expects for any workstation, mobile or fixed.<\/p>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-19512\" src=\"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/10\/Mobile-ESD-Workstation-Smartphone-Repair-Bench-1-1.jpg\" alt=\"Mobile ESD Workstation Smartphone Repair Bench Mobile ESD-Werkbank f\u00fcr Smartphone-Reparaturen\" width=\"1920\" height=\"1079\" \/><\/p>\n<p><a class=\"cta-primary\" href=\"https:\/\/www.shop-tps.com\/shop\/category\/esd-workshop-esd-table-154\" target=\"_blank\" rel=\"noopener noreferrer nofollow\">Explore ESD workstations \u2192<\/a><\/p>\n<\/section>\n<section id=\"en-fixed1260\">\n<h2>2. What the TPS Fixed-1260 provides as the bench platform<\/h2>\n<p>The Fixed-1260 designed as a fixed installation for electronics production, laboratory, and industrial workshop use. Its value in a rework context is the combination of a stable, heavy-duty frame, a compliant antistatic worktop, and a modular accessory system that can be configured for board-level repair.<\/p>\n<h3 id=\"en-specs\">2.1 Dimensions, load, and worktop<\/h3>\n<p>The bench measures 1220 mm in length, 600 mm in depth, and 760 mm in fixed height. The 25 mm ESD (HPL) laminated top in RAL 7035 provides a durable, easy-to-clean work surface. The frame rated for a uniform static load of up to 500 kg, which is far above what a rework station typically carries\u2014but it matters when the bench also holds a microscope, a hot-air station, a power supply, and a drawer stack, and when the bench is moved as a complete unit rather than disassembled.<\/p>\n<p>The 760 mm fixed height is a standard industrial work height. For a seated rework operator, that height is generally suitable with an adjustable ESD chair; for a standing operator, it may be too low. This is the point where the \u201cheight-adjustable\u201d requirement in many RFQs has to be addressed explicitly: the Fixed-1260 is not height-adjustable, so either the chair provides the adjustment, or a different bench model is required.<\/p>\n<h3 id=\"en-compliance\">2.2 IEC 61340-5-1 compliance and humidity range<\/h3>\n<p>The bench specified to meet IEC 61340-5-1:2016 and to maintain stable static control performance across 10\u201360% relative humidity. The humidity range matters because surface resistivity of dissipative materials changes with moisture; a bench that performs well at 50% RH can drift outside the dissipative range in a very dry room. The stated 10\u201360% range gives the procurement team a defensible specification for the facility\u2019s environmental envelope.<\/p>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-19507\" src=\"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/10\/ESD-Workstation-Grounding-Verification-IEC-61340-5-1-2.jpg\" alt=\"ESD Workstation Grounding Verification IEC 61340-5-1 \u00dcberpr\u00fcfung der Erdung von ESD-Arbeitspl\u00e4tzen gem\u00e4\u00df IEC 61340-5-1\" width=\"1920\" height=\"1079\" \/><\/p>\n<\/section>\n<section id=\"en-configuration\">\n<h2>3. Configuring the bench for smartphone and board-level rework<\/h2>\n<p>A smartphone rework station needs more than a flat surface. It needs controlled lighting, a power rail for the hot-air station and the microscope, storage for parts and tools, and a grounding arrangement that keeps the operator and the board at the same potential.<\/p>\n<h3 id=\"en-grounding\">3.1 Grounding and verification points<\/h3>\n<p>Connect the worktop groundable point to the common ground cord, and connect the common ground cord to the protective earth of the building installation through a dedicated earth bond. The wrist strap connects to the same common ground point. Provide a clearly labeled verification point for the worktop-to-earth resistance and a second point for the wrist strap test, so that the daily check can be performed in under a minute without disassembling anything.<\/p>\n<p>The verification itself is a resistance measurement: worktop to earth, and wrist strap to earth, compared against the limits defined in the facility\u2019s ESD control plan. The measurement instrument and the limits should recorded in the station documentation, not left to operator memory.<\/p>\n<h3 id=\"en-accessories\">3.2 Accessory set for rework<\/h3>\n<p>TPS offers a matching accessory family for the Fixed-1260: antistatic steel shelves, back panels, suspension drawers, LED light systems, German-type power rails, and ESD chairs. For a smartphone rework station, the practical configuration is:<\/p>\n<ul>\n<li><strong>LED light bar<\/strong> mounted on the back panel, positioned to illuminate the work area without casting shadow from the operator\u2019s hands.<\/li>\n<li><strong>Power rail<\/strong> for the hot-air station, soldering iron, microscope illuminator, and bench power supply.<\/li>\n<li><strong>Suspension drawer<\/strong> for tips, nozzles, tweezers, and small parts trays.<\/li>\n<li><strong>Antistatic shelf<\/strong> for the microscope and for frequently used test equipment.<\/li>\n<li><strong>ESD chair<\/strong> with a grounded seat and a height adjustment that brings the operator to the correct working height relative to the fixed 760 mm bench.<\/li>\n<\/ul>\n<p>The modular system means the same bench frame can be reconfigured when the rework scope changes\u2014for example from smartphone board repair to small-form-factor assembly\u2014without replacing the bench.<\/p>\n<h3 id=\"en-relocation\">3.3 Relocation options for a fixed frame<\/h3>\n<p>If the station must move, the relocation method has to chosen deliberately. Three options are common:<\/p>\n<ul>\n<li><strong>Heavy-duty castor set:<\/strong> allows the bench to rolled between locations. The castors must rated for the loaded bench weight, and the ground cord must disconnected before the move and reconnected and verified afterward. A castor-mounted bench should not rely on the castors for earth bonding.<\/li>\n<li><strong>Pallet-jack skid base:<\/strong> the bench lifted and moved as a unit, which is suitable for heavier configurations where castors would undersized. The bench must designed or adapted for the skid base, and the move requires a pallet jack and a clear route.<\/li>\n<li><strong>Crane lifting eyes:<\/strong> for moving the bench into position during installation, not for routine relocation. Lifting points must rated and the load balanced.<\/li>\n<\/ul>\n<p>None of these options is included in the standard Fixed-1260 configuration. They are additions or adaptations that must specified in the RFQ, and each one changes the mechanical interface and the verification procedure after a move.<\/p>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-19502\" src=\"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/10\/Height-Adjustable-ESD-Cart-Castor-Base-Options-3.jpg\" alt=\"Height Adjustable ESD Cart Castor Base Options Optionen f\u00fcr das Rollengestell von h\u00f6henverstellbaren ESD-Wagen\" width=\"1920\" height=\"1079\" \/><\/p>\n<p><a class=\"cta-primary\" href=\"https:\/\/www.shop-tps.com\/shop\/category\/esd-workshop-esd-table-154\" target=\"_blank\" rel=\"noopener noreferrer nofollow\">Request a configured ESD station quotation \u2192<\/a><\/p>\n<\/section>\n<section id=\"en-daily-checks\">\n<h2>4. Daily and periodic verification<\/h2>\n<p>The ESD control plan determines the verification interval, but the practical minimum for a rework station is a daily check before the first board is handled. The check covers the wrist strap, the worktop, and the ground connection. For a station that moves, the check is repeated after every relocation, because the move is the event most likely to break the ground path.<\/p>\n<p>The verification record should include the date, the instrument used, the measured values, and the pass\/fail result. That record is what an ESD auditor reviews; the product certificate alone is not sufficient evidence that the station is functioning on the day of the audit.<\/p>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-19497\" src=\"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/10\/ESD-Safe-Mobile-Repair-Cart-Modular-Accessories-4.jpg\" alt=\"ESD Safe Mobile Repair Cart Modular Accessories Modulares Zubeh\u00f6r f\u00fcr ESD-sichere Servicewagen zur Mobilger\u00e4tereparatur\" width=\"1920\" height=\"1079\" \/><\/p>\n<\/section>\n<section id=\"en-specs\">\n<h2>5. Product specifications<\/h2>\n<table>\n<thead>\n<tr>\n<th>Parameter<\/th>\n<th>TPS Fixed-1260<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Type<\/td>\n<td>Fixed ESD workbench<\/td>\n<\/tr>\n<tr>\n<td>Dimensions (L \u00d7 D \u00d7 H)<\/td>\n<td>1220 \u00d7 600 \u00d7 760 mm<\/td>\n<\/tr>\n<tr>\n<td>Height adjustment<\/td>\n<td>None (fixed 760 mm)<\/td>\n<\/tr>\n<tr>\n<td>Worktop<\/td>\n<td>25 mm ESD (HPL) laminate, RAL 7035<\/td>\n<\/tr>\n<tr>\n<td>Uniform static load<\/td>\n<td>Up to 500 kg<\/td>\n<\/tr>\n<tr>\n<td>ESD standard<\/td>\n<td>IEC 61340-5-1:2016<\/td>\n<\/tr>\n<tr>\n<td>Humidity range<\/td>\n<td>10\u201360% RH<\/td>\n<\/tr>\n<tr>\n<td>Accessory system<\/td>\n<td>Antistatic shelves, back panels, suspension drawers, LED lighting, power rails, ESD chairs<\/td>\n<\/tr>\n<tr>\n<td>Castors \/ lifting eyes<\/td>\n<td>Not included as standard<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The table makes the boundary explicit: the Fixed-1260 is a fixed platform. The \u201cmobile\u201d and \u201cheight-adjustable\u201d attributes have to added through the accessory or adaptation route, or addressed by selecting a different bench model.<\/p>\n<\/section>\n<section id=\"en-rfq\">\n<h2>6. RFQ checklist<\/h2>\n<p>To get a usable quotation for an ESD rework station, provide the following:<\/p>\n<ul>\n<li><strong>Station type:<\/strong> Fixed installation, or relocatable\u2014and if relocatable, the expected relocation frequency<\/li>\n<li><strong>Operator posture:<\/strong> Seated or standing, and whether the adjustment is expected from the chair or from the bench<\/li>\n<li><strong>Work content:<\/strong> Smartphone board rework, small-form-factor assembly, or mixed use<\/li>\n<li><strong>Equipment load:<\/strong> Microscope, hot-air station, power supply, drawer stack, and total weight<\/li>\n<li><strong>Grounding requirement:<\/strong> Whether a common ground cord, wrist strap and verification points are to be supplied<\/li>\n<li><strong>Accessory list:<\/strong> Shelves, back panel, drawer, LED light, power rail, ESD chair<\/li>\n<li><strong>Relocation method:<\/strong> Castors, skid base, or lifting eyes\u2014and the floor condition along the route<\/li>\n<li><strong>Documentation:<\/strong> ESD compliance certificate, grounding verification procedure, and accessory list<\/li>\n<\/ul>\n<p>Providing these details prevents the most common mismatch: ordering a fixed bench for a station that has to move, or expecting height adjustment from a bench that does not have it.<\/p>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-19517\" src=\"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/10\/ESD1081-Fixed-1260-1.png\" alt=\"mobile esd workstation\" width=\"768\" height=\"1024\" \/><\/p>\n<p><a class=\"cta-primary\" href=\"https:\/\/www.shop-tps.com\/shop\/category\/esd-workshop-esd-table-154\" target=\"_blank\" rel=\"noopener noreferrer nofollow\">Submit your ESD station RFQ \u2192<\/a><\/p>\n<\/section>\n<section id=\"en-faq\">\n<h2>7. FAQ<\/h2>\n<div>\n<h3>Is the TPS Fixed-1260 a mobile ESD workstation?<\/h3>\n<div>No. It is a fixed ESD workbench with a fixed 760 mm height and no castors as standard. It can be made relocatable by adding a castor set, a skid base, or lifting eyes, but those are additions that must be specified in the RFQ. If the requirement is a bench that is mobile out of the box, a different model should be selected.<\/div>\n<\/div>\n<div>\n<h3>Is the Fixed-1260 height-adjustable?<\/h3>\n<div>No. The height is fixed at 760 mm. For a seated operator, the height adjustment is normally provided by the ESD chair. For a standing operator, 760 mm may be too low, and a different bench model is the correct choice.<\/div>\n<\/div>\n<div>\n<h3>What ESD standard does the bench meet?<\/h3>\n<div>The bench is specified to meet IEC 61340-5-1:2016 and to maintain stable static control performance across 10\u201360% relative humidity. The compliance certificate is only part of the evidence; the daily and periodic verification records are what demonstrate that the station is functioning.<\/div>\n<\/div>\n<div>\n<h3>Can the bench be moved without losing ESD protection?<\/h3>\n<div>Yes, if the ground cord disconnected before the move, reconnected afterward, and the worktop-to-earth and wrist strap checks are repeated. A castor-mounted bench should not rely on the castors for earth bonding; the ground cord remains the controlled path.<\/div>\n<\/div>\n<div>\n<h3>What accessories are available for smartphone rework?<\/h3>\n<div>Antistatic steel shelves, back panels, suspension drawers, LED light systems, German-type power rails and ESD chairs. The modular system allows the same bench frame to be reconfigured when the rework scope changes.<\/div>\n<\/div>\n<\/section>\n<footer style=\"background: #2d5797; padding: 30px; border-radius: 14px; margin-top: 40px;\">\n<p style=\"color: #ffffff; font-size: 16px; line-height: 1.6; margin: 0;\"><strong>Next step:<\/strong> Tell TPS whether the station is fixed or relocatable, whether the operator is seated or standing, and what equipment the bench must carry. TPS will confirm the bench model, the accessory list, and the grounding verification plan. <a style=\"color: #ffffff; font-weight: 600; text-decoration: underline;\" href=\"https:\/\/www.shop-tps.com\/shop\/category\/esd-workshop-esd-table-154\" target=\"_blank\" rel=\"noopener noreferrer nofollow\">Request your ESD station configuration \u2192<\/a><\/p>\n<\/footer><\/article>\n\n<style id=\"wpforms-css-vars-4659-block-e5a623c3-405a-4282-9b86-3b3782b97641\">\n\t\t\t\t#wpforms-4659.wpforms-block-e5a623c3-405a-4282-9b86-3b3782b97641 {\n\t\t\t\t--wpforms-field-size-input-height: 43px;\n--wpforms-field-size-input-spacing: 15px;\n--wpforms-field-size-font-size: 16px;\n--wpforms-field-size-line-height: 19px;\n--wpforms-field-size-padding-h: 14px;\n--wpforms-field-size-checkbox-size: 16px;\n--wpforms-field-size-sublabel-spacing: 5px;\n--wpforms-field-size-icon-size: 1;\n--wpforms-label-size-font-size: 16px;\n--wpforms-label-size-line-height: 19px;\n--wpforms-label-size-sublabel-font-size: 14px;\n--wpforms-label-size-sublabel-line-height: 17px;\n--wpforms-button-size-font-size: 17px;\n--wpforms-button-size-height: 41px;\n--wpforms-button-size-padding-h: 15px;\n--wpforms-button-size-margin-top: 10px;\n\t\t\t}\n\t\t\t<\/style><div class=\"wpforms-container wpforms-container-full wpforms-block wpforms-block-e5a623c3-405a-4282-9b86-3b3782b97641 wpforms-render-modern\" id=\"wpforms-4659\"><form id=\"wpforms-form-4659\" class=\"wpforms-validate wpforms-form wpforms-ajax-form\" data-formid=\"4659\" method=\"post\" enctype=\"multipart\/form-data\" action=\"\/en\/wp-json\/wp\/v2\/posts\/19385\" data-token=\"bbc3eed91e0104c229583ac297160b9c\" data-token-time=\"1795139476\"><noscript class=\"wpforms-error-noscript\">Please enable JavaScript in your browser to complete this form.<\/noscript><div id=\"wpforms-error-noscript\" style=\"display: none;\">Please enable JavaScript in your browser to complete this form.<\/div><div class=\"wpforms-field-container\"><div id=\"wpforms-4659-field_1-container\" class=\"wpforms-field wpforms-field-name\" data-field-id=\"1\"><fieldset><legend class=\"wpforms-field-label\">Name <span class=\"wpforms-required-label\" aria-hidden=\"true\">*<\/span><\/legend><div class=\"wpforms-field-row wpforms-field-large\"><div class=\"wpforms-field-row-block wpforms-first wpforms-one-half\"><input type=\"text\" id=\"wpforms-4659-field_1\" class=\"wpforms-field-name-first wpforms-field-required\" name=\"wpforms[fields][1][first]\" aria-errormessage=\"wpforms-4659-field_1-error\" required><label for=\"wpforms-4659-field_1\" class=\"wpforms-field-sublabel after\">First<\/label><\/div><div class=\"wpforms-field-row-block wpforms-one-half\"><input type=\"text\" id=\"wpforms-4659-field_1-last\" class=\"wpforms-field-name-last wpforms-field-required\" name=\"wpforms[fields][1][last]\" aria-errormessage=\"wpforms-4659-field_1-last-error\" required><label for=\"wpforms-4659-field_1-last\" class=\"wpforms-field-sublabel after\">Last<\/label><\/div><\/div><\/fieldset><\/div><div id=\"wpforms-4659-field_4-container\" class=\"wpforms-field wpforms-field-text\" data-field-id=\"4\"><label class=\"wpforms-field-label\" for=\"wpforms-4659-field_4\">Company <span class=\"wpforms-required-label\" aria-hidden=\"true\">*<\/span><\/label><input type=\"text\" id=\"wpforms-4659-field_4\" class=\"wpforms-field-large wpforms-field-required\" name=\"wpforms[fields][4]\" aria-errormessage=\"wpforms-4659-field_4-error\" required><\/div>\t\t<div id=\"wpforms-4659-field_5-container\"\n\t\t\tclass=\"wpforms-field wpforms-field-text\"\n\t\t\tdata-field-type=\"text\"\n\t\t\tdata-field-id=\"5\"\n\t\t\t>\n\t\t\t<label class=\"wpforms-field-label\" for=\"wpforms-4659-field_5\" >Company Comment Email<\/label>\n\t\t\t<input type=\"text\" id=\"wpforms-4659-field_5\" class=\"wpforms-field-medium\" name=\"wpforms[fields][5]\" >\n\t\t<\/div>\n\t\t<div id=\"wpforms-4659-field_2-container\" class=\"wpforms-field wpforms-field-email\" data-field-id=\"2\"><label class=\"wpforms-field-label\" for=\"wpforms-4659-field_2\">Email <span class=\"wpforms-required-label\" aria-hidden=\"true\">*<\/span><\/label><input type=\"email\" id=\"wpforms-4659-field_2\" class=\"wpforms-field-large wpforms-field-required\" name=\"wpforms[fields][2]\" spellcheck=\"false\" aria-errormessage=\"wpforms-4659-field_2-error\" required><\/div><div id=\"wpforms-4659-field_3-container\" class=\"wpforms-field wpforms-field-textarea\" data-field-id=\"3\"><label class=\"wpforms-field-label\" for=\"wpforms-4659-field_3\">Comment or Message<\/label><textarea id=\"wpforms-4659-field_3\" class=\"wpforms-field-medium\" name=\"wpforms[fields][3]\" aria-errormessage=\"wpforms-4659-field_3-error\" ><\/textarea><\/div><div id=\"wpforms-4659-field_6-container\" class=\"wpforms-field wpforms-field-checkbox\" data-field-id=\"6\"><fieldset><legend class=\"wpforms-field-label wpforms-label-hide\" aria-hidden=\"false\">Checkbox <span class=\"wpforms-required-label\" aria-hidden=\"true\">*<\/span><\/legend><ul id=\"wpforms-4659-field_6\" class=\"wpforms-field-required\"><li class=\"choice-1 depth-1 wpforms-selected\"><input type=\"checkbox\" id=\"wpforms-4659-field_6_1\" name=\"wpforms[fields][6][]\" value=\"I agree to the processing of my information for the purpose of creating a quote.\" aria-errormessage=\"wpforms-4659-field_6_1-error\" aria-describedby=\"wpforms-4659-field_6-description\" required  checked='checked'><label class=\"wpforms-field-label-inline\" for=\"wpforms-4659-field_6_1\">I agree to the processing of my information for the purpose of creating a quote.<\/label><\/li><\/ul><div id=\"wpforms-4659-field_6-description\" class=\"wpforms-field-description\">For information see Privacy.<\/div><\/fieldset><\/div><script>\n\t\t\t\t( function() {\n\t\t\t\t\tconst style = document.createElement( 'style' );\n\t\t\t\t\tstyle.appendChild( document.createTextNode( '#wpforms-4659-field_5-container { position: absolute !important; overflow: hidden !important; display: inline !important; height: 1px !important; width: 1px !important; z-index: -1000 !important; padding: 0 !important; } #wpforms-4659-field_5-container input { visibility: hidden; } #wpforms-conversational-form-page #wpforms-4659-field_5-container label { counter-increment: none; }' ) );\n\t\t\t\t\tdocument.head.appendChild( style );\n\t\t\t\t\tdocument.currentScript?.remove();\n\t\t\t\t} )();\n\t\t\t<\/script><\/div><!-- .wpforms-field-container --><div class=\"wpforms-recaptcha-container wpforms-is-turnstile\" ><div class=\"wpforms-turnstile\" data-sitekey=\"0x4AAAAAAFUTE-Rr1O4nxKnU\" data-action=\"FormID-4659\"><\/div><input type=\"text\" name=\"g-recaptcha-hidden\" class=\"wpforms-recaptcha-hidden\" style=\"position:absolute!important;clip:rect(0,0,0,0)!important;height:1px!important;width:1px!important;border:0!important;overflow:hidden!important;padding:0!important;margin:0!important;\" data-rule-turnstile=\"1\"><\/div><div class=\"wpforms-submit-container\" ><input type=\"hidden\" name=\"wpforms[id]\" value=\"4659\"><input type=\"hidden\" name=\"wpforms[time_token]\" value=\"1795139476.ad75b807be641fb865a7bba6611b0fa1098132cda820624344c2755d8baf4462\"><input type=\"hidden\" name=\"page_title\" value=\"\"><input type=\"hidden\" name=\"page_url\" value=\"https:\/\/tps-elektronik.com\/en\/wp-json\/wp\/v2\/posts\/19385\"><input type=\"hidden\" name=\"url_referer\" value=\"\"><button type=\"submit\" name=\"wpforms[submit]\" id=\"wpforms-submit-4659\" class=\"wpforms-submit\" data-alt-text=\"Sending...\" data-submit-text=\"Submit\" aria-live=\"assertive\" value=\"wpforms-submit\">Submit<\/button><img decoding=\"async\" src=\"https:\/\/tps-elektronik.com\/wp-content\/plugins\/wpforms-lite\/assets\/images\/submit-spin.svg\" class=\"wpforms-submit-spinner\" style=\"display: none;\" width=\"26\" height=\"26\" alt=\"Loading\"><\/div><\/form><\/div>  <!-- .wpforms-container -->","protected":false},"excerpt":{"rendered":"<p>For system integrators, panel builders, and engineering-driven procurement teams, setting up an ESD repair station for smartphone and electronics rework is not only about buying a bench. It also involves the grounding architecture, the surface resistivity of the worktop, the wrist strap and common ground point, the accessory set that makes the bench usable for\u2026 <a href=\"https:\/\/tps-elektronik.com\/en\/how-to-set-up-a-flexible-mobile-esd-repair-station-for-smartphone-and-electronics-rework-with-tps-height-adjustable-workstations\/\">Read More &raquo;<\/a><\/p>\n","protected":false},"author":9,"featured_media":19517,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[53],"tags":[],"class_list":["post-19385","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-production"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>TPS Mobile ESD Workstation - TPS<\/title>\n<meta name=\"description\" content=\"Mobile ESD workstation setup for smartphone repair and electronics rework: ESD compliance, grounding checks, and modular bench configuration.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/tps-elektronik.com\/en\/how-to-set-up-a-flexible-mobile-esd-repair-station-for-smartphone-and-electronics-rework-with-tps-height-adjustable-workstations\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"TPS Mobile ESD Workstation - TPS\" \/>\n<meta property=\"og:description\" content=\"Mobile ESD workstation setup for smartphone repair and electronics rework: ESD compliance, grounding checks, and modular bench configuration.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/tps-elektronik.com\/en\/how-to-set-up-a-flexible-mobile-esd-repair-station-for-smartphone-and-electronics-rework-with-tps-height-adjustable-workstations\/\" \/>\n<meta property=\"og:site_name\" content=\"TPS\" \/>\n<meta property=\"article:published_time\" content=\"2026-11-20T00:52:50+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-11-20T00:52:56+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/10\/ESD1081-Fixed-1260-1.png\" \/>\n\t<meta property=\"og:image:width\" content=\"768\" \/>\n\t<meta property=\"og:image:height\" content=\"1024\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Tang Marcus\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Tang Marcus\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"11 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/how-to-set-up-a-flexible-mobile-esd-repair-station-for-smartphone-and-electronics-rework-with-tps-height-adjustable-workstations\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/how-to-set-up-a-flexible-mobile-esd-repair-station-for-smartphone-and-electronics-rework-with-tps-height-adjustable-workstations\\\/\"},\"author\":{\"name\":\"Tang Marcus\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/#\\\/schema\\\/person\\\/2c19fd053095d0c1ae253e8e62427b8c\"},\"headline\":\"How to Set Up a Flexible Mobile ESD Repair Station for Smartphone and Electronics Rework With TPS Height-Adjustable Workstations?\",\"datePublished\":\"2026-11-20T00:52:50+00:00\",\"dateModified\":\"2026-11-20T00:52:56+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/how-to-set-up-a-flexible-mobile-esd-repair-station-for-smartphone-and-electronics-rework-with-tps-height-adjustable-workstations\\\/\"},\"wordCount\":2062,\"image\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/how-to-set-up-a-flexible-mobile-esd-repair-station-for-smartphone-and-electronics-rework-with-tps-height-adjustable-workstations\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/tps-elektronik.com\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/ESD1081-Fixed-1260-1.png\",\"articleSection\":[\"Product\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/how-to-set-up-a-flexible-mobile-esd-repair-station-for-smartphone-and-electronics-rework-with-tps-height-adjustable-workstations\\\/\",\"url\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/how-to-set-up-a-flexible-mobile-esd-repair-station-for-smartphone-and-electronics-rework-with-tps-height-adjustable-workstations\\\/\",\"name\":\"TPS Mobile ESD Workstation - TPS\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/how-to-set-up-a-flexible-mobile-esd-repair-station-for-smartphone-and-electronics-rework-with-tps-height-adjustable-workstations\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/how-to-set-up-a-flexible-mobile-esd-repair-station-for-smartphone-and-electronics-rework-with-tps-height-adjustable-workstations\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/tps-elektronik.com\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/ESD1081-Fixed-1260-1.png\",\"datePublished\":\"2026-11-20T00:52:50+00:00\",\"dateModified\":\"2026-11-20T00:52:56+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/#\\\/schema\\\/person\\\/2c19fd053095d0c1ae253e8e62427b8c\"},\"description\":\"Mobile ESD workstation setup for smartphone repair and electronics rework: ESD compliance, grounding checks, and modular bench configuration.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/how-to-set-up-a-flexible-mobile-esd-repair-station-for-smartphone-and-electronics-rework-with-tps-height-adjustable-workstations\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/how-to-set-up-a-flexible-mobile-esd-repair-station-for-smartphone-and-electronics-rework-with-tps-height-adjustable-workstations\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/how-to-set-up-a-flexible-mobile-esd-repair-station-for-smartphone-and-electronics-rework-with-tps-height-adjustable-workstations\\\/#primaryimage\",\"url\":\"https:\\\/\\\/tps-elektronik.com\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/ESD1081-Fixed-1260-1.png\",\"contentUrl\":\"https:\\\/\\\/tps-elektronik.com\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/ESD1081-Fixed-1260-1.png\",\"width\":768,\"height\":1024,\"caption\":\"mobile esd workstation\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/how-to-set-up-a-flexible-mobile-esd-repair-station-for-smartphone-and-electronics-rework-with-tps-height-adjustable-workstations\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Startseite\",\"item\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"How to Set Up a Flexible Mobile ESD Repair Station for Smartphone and Electronics Rework With TPS Height-Adjustable Workstations?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/\",\"name\":\"TPS\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/#\\\/schema\\\/person\\\/2c19fd053095d0c1ae253e8e62427b8c\",\"name\":\"Tang Marcus\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"TPS Mobile ESD Workstation - TPS","description":"Mobile ESD workstation setup for smartphone repair and electronics rework: ESD compliance, grounding checks, and modular bench configuration.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/tps-elektronik.com\/en\/how-to-set-up-a-flexible-mobile-esd-repair-station-for-smartphone-and-electronics-rework-with-tps-height-adjustable-workstations\/","og_locale":"en_US","og_type":"article","og_title":"TPS Mobile ESD Workstation - TPS","og_description":"Mobile ESD workstation setup for smartphone repair and electronics rework: ESD compliance, grounding checks, and modular bench configuration.","og_url":"https:\/\/tps-elektronik.com\/en\/how-to-set-up-a-flexible-mobile-esd-repair-station-for-smartphone-and-electronics-rework-with-tps-height-adjustable-workstations\/","og_site_name":"TPS","article_published_time":"2026-11-20T00:52:50+00:00","article_modified_time":"2026-11-20T00:52:56+00:00","og_image":[{"width":768,"height":1024,"url":"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/10\/ESD1081-Fixed-1260-1.png","type":"image\/png"}],"author":"Tang Marcus","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Tang Marcus","Est. reading time":"11 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/tps-elektronik.com\/en\/how-to-set-up-a-flexible-mobile-esd-repair-station-for-smartphone-and-electronics-rework-with-tps-height-adjustable-workstations\/#article","isPartOf":{"@id":"https:\/\/tps-elektronik.com\/en\/how-to-set-up-a-flexible-mobile-esd-repair-station-for-smartphone-and-electronics-rework-with-tps-height-adjustable-workstations\/"},"author":{"name":"Tang Marcus","@id":"https:\/\/tps-elektronik.com\/en\/#\/schema\/person\/2c19fd053095d0c1ae253e8e62427b8c"},"headline":"How to Set Up a Flexible Mobile ESD Repair Station for Smartphone and Electronics Rework With TPS Height-Adjustable Workstations?","datePublished":"2026-11-20T00:52:50+00:00","dateModified":"2026-11-20T00:52:56+00:00","mainEntityOfPage":{"@id":"https:\/\/tps-elektronik.com\/en\/how-to-set-up-a-flexible-mobile-esd-repair-station-for-smartphone-and-electronics-rework-with-tps-height-adjustable-workstations\/"},"wordCount":2062,"image":{"@id":"https:\/\/tps-elektronik.com\/en\/how-to-set-up-a-flexible-mobile-esd-repair-station-for-smartphone-and-electronics-rework-with-tps-height-adjustable-workstations\/#primaryimage"},"thumbnailUrl":"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/10\/ESD1081-Fixed-1260-1.png","articleSection":["Product"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/tps-elektronik.com\/en\/how-to-set-up-a-flexible-mobile-esd-repair-station-for-smartphone-and-electronics-rework-with-tps-height-adjustable-workstations\/","url":"https:\/\/tps-elektronik.com\/en\/how-to-set-up-a-flexible-mobile-esd-repair-station-for-smartphone-and-electronics-rework-with-tps-height-adjustable-workstations\/","name":"TPS Mobile ESD Workstation - TPS","isPartOf":{"@id":"https:\/\/tps-elektronik.com\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/tps-elektronik.com\/en\/how-to-set-up-a-flexible-mobile-esd-repair-station-for-smartphone-and-electronics-rework-with-tps-height-adjustable-workstations\/#primaryimage"},"image":{"@id":"https:\/\/tps-elektronik.com\/en\/how-to-set-up-a-flexible-mobile-esd-repair-station-for-smartphone-and-electronics-rework-with-tps-height-adjustable-workstations\/#primaryimage"},"thumbnailUrl":"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/10\/ESD1081-Fixed-1260-1.png","datePublished":"2026-11-20T00:52:50+00:00","dateModified":"2026-11-20T00:52:56+00:00","author":{"@id":"https:\/\/tps-elektronik.com\/en\/#\/schema\/person\/2c19fd053095d0c1ae253e8e62427b8c"},"description":"Mobile ESD workstation setup for smartphone repair and electronics rework: ESD compliance, grounding checks, and modular bench configuration.","breadcrumb":{"@id":"https:\/\/tps-elektronik.com\/en\/how-to-set-up-a-flexible-mobile-esd-repair-station-for-smartphone-and-electronics-rework-with-tps-height-adjustable-workstations\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/tps-elektronik.com\/en\/how-to-set-up-a-flexible-mobile-esd-repair-station-for-smartphone-and-electronics-rework-with-tps-height-adjustable-workstations\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/tps-elektronik.com\/en\/how-to-set-up-a-flexible-mobile-esd-repair-station-for-smartphone-and-electronics-rework-with-tps-height-adjustable-workstations\/#primaryimage","url":"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/10\/ESD1081-Fixed-1260-1.png","contentUrl":"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/10\/ESD1081-Fixed-1260-1.png","width":768,"height":1024,"caption":"mobile esd workstation"},{"@type":"BreadcrumbList","@id":"https:\/\/tps-elektronik.com\/en\/how-to-set-up-a-flexible-mobile-esd-repair-station-for-smartphone-and-electronics-rework-with-tps-height-adjustable-workstations\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Startseite","item":"https:\/\/tps-elektronik.com\/en\/"},{"@type":"ListItem","position":2,"name":"How to Set Up a Flexible Mobile ESD Repair Station for Smartphone and Electronics Rework With TPS Height-Adjustable Workstations?"}]},{"@type":"WebSite","@id":"https:\/\/tps-elektronik.com\/en\/#website","url":"https:\/\/tps-elektronik.com\/en\/","name":"TPS","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/tps-elektronik.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/tps-elektronik.com\/en\/#\/schema\/person\/2c19fd053095d0c1ae253e8e62427b8c","name":"Tang Marcus"}]}},"_links":{"self":[{"href":"https:\/\/tps-elektronik.com\/en\/wp-json\/wp\/v2\/posts\/19385","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/tps-elektronik.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/tps-elektronik.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/tps-elektronik.com\/en\/wp-json\/wp\/v2\/users\/9"}],"replies":[{"embeddable":true,"href":"https:\/\/tps-elektronik.com\/en\/wp-json\/wp\/v2\/comments?post=19385"}],"version-history":[{"count":2,"href":"https:\/\/tps-elektronik.com\/en\/wp-json\/wp\/v2\/posts\/19385\/revisions"}],"predecessor-version":[{"id":19523,"href":"https:\/\/tps-elektronik.com\/en\/wp-json\/wp\/v2\/posts\/19385\/revisions\/19523"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/tps-elektronik.com\/en\/wp-json\/wp\/v2\/media\/19517"}],"wp:attachment":[{"href":"https:\/\/tps-elektronik.com\/en\/wp-json\/wp\/v2\/media?parent=19385"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/tps-elektronik.com\/en\/wp-json\/wp\/v2\/categories?post=19385"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/tps-elektronik.com\/en\/wp-json\/wp\/v2\/tags?post=19385"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}