{"id":17247,"date":"2026-09-22T09:00:00","date_gmt":"2026-09-22T07:00:00","guid":{"rendered":"https:\/\/tps-elektronik.com\/?p=17247"},"modified":"2026-09-01T04:53:45","modified_gmt":"2026-09-01T02:53:45","slug":"how-to-ensure-accurate-signal-transmission-in-industrial-rtd-and-thermocouple-temperature-sensors-with-tps-shielded-sensor-cable-assembly","status":"publish","type":"post","link":"https:\/\/tps-elektronik.com\/en\/how-to-ensure-accurate-signal-transmission-in-industrial-rtd-and-thermocouple-temperature-sensors-with-tps-shielded-sensor-cable-assembly\/","title":{"rendered":"How to Ensure Accurate Signal Transmission in Industrial RTD and Thermocouple Temperature Sensors with TPS Shielded Sensor Cable Assembly?"},"content":{"rendered":"<article class=\"blog-post\" lang=\"en\"><header>\n<p>For system integrators, panel builders, and electrical engineers working with industrial temperature measurement, the cable connecting an RTD or thermocouple sensor to the control system is not a passive component\u2014it is an active part of the measurement chain. A poorly chosen or improperly assembled cable can introduce errors that compromise process control, product quality, and safety.<\/p>\n<p>TPS Elektronik&#8217;s <strong>sensor cable assembly<\/strong> service delivers shielded, precision-terminated cables for RTD and thermocouple temperature sensors\u2014engineered to preserve signal integrity in electrically noisy industrial environments, with documented quality and full traceability from prototype to production.<\/p>\n<p><a class=\"cta-primary\" href=\"https:\/\/tps-elektronik.com\/en\/services\/ems\/cable-assembly\/\">Request a sensor cable assembly quote \u2192<\/a><\/p>\n<\/header><nav class=\"toc\" aria-label=\"Table of contents\">\n<h2 id=\"toc\">Table of Contents<\/h2>\n<ol>\n<li><a href=\"#measurement-challenge\">The Temperature Measurement Challenge: Noise, Distance, and Accuracy<\/a><\/li>\n<li><a href=\"#shielding\">Shielding: Protecting the Weak Signal from Electrical Noise<\/a><\/li>\n<li><a href=\"#twisted-pairs\">Twisted Pairs: Reducing Magnetic Field Coupling<\/a><\/li>\n<li><a href=\"#grounding\">Grounding the Shield: One Point or Multiple?<\/a><\/li>\n<li><a href=\"#wire-configuration\">Wire Configuration: 2-Wire, 3-Wire, and 4-Wire RTD Connections<\/a><\/li>\n<li><a href=\"#materials-selection\">Materials Selection: Insulation, Jacket, and Temperature Rating<\/a><\/li>\n<li><a href=\"#tps-capabilities\">TPS Sensor Cable Assembly Capabilities<\/a><\/li>\n<li><a href=\"#faq\">FAQ<\/a><\/li>\n<\/ol>\n<\/nav>\n<section id=\"measurement-challenge\">\n<h2>1. The Temperature Measurement Challenge: Noise, Distance, and Accuracy<\/h2>\n<p>Industrial temperature sensors\u2014RTDs (Resistance Temperature Detectors) and thermocouples\u2014produce relatively weak electrical signals that are highly susceptible to electromagnetic interference (EMI) from nearby equipment. A 100 \u03a9 Pt RTD has a temperature coefficient of only <strong>0.385 \u03a9\/\u00b0C<\/strong> at 0 \u00b0C, meaning every 0.385 \u03a9 of uncorrected loop resistance translates directly into a <strong>1 \u00b0C measurement error<\/strong>. Thermocouples generate millivolt-level signals that are even more vulnerable to noise pickup.<\/p>\n<p>In modern factory automation environments, the sources of electrical noise are everywhere: variable frequency drives (VFDs), motor starters, contactors, welding equipment, and radio transmitters all generate electromagnetic fields that can couple into unshielded sensor cables. An unshielded RTD lead can act as an antenna, coupling radio-frequency interference (RFI) into the measurement signal.<\/p>\n<p>For system integrators and electrical engineers, the challenge compounded by cable length. Sensors often located hundreds of meters from the control cabinet or PLC, and long cable runs provide more opportunity for noise pickup and signal degradation.<\/p>\n<p>The solution lies in a combination of factors: <strong>shielded cable construction<\/strong>, <strong>twisted pair geometry<\/strong>, <strong>proper grounding practices<\/strong>, <strong>appropriate wire configuration<\/strong>, and <strong>precision termination<\/strong>. TPS Elektronik&#8217;s <strong>sensor cable assembly<\/strong> service addresses each of these factors, delivering cables that preserve signal integrity from sensor to controller.<\/p>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-17333\" src=\"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/09\/RTD-2-Wire-3-Wire-4-Wire-Connection-Configurations-2-1.jpg\" alt=\"RTD 2-Wire 3-Wire 4-Wire Connection Configurations RTD-Anschlusskonfigurationen: 2-Draht, 3-Draht, 4-Draht\" width=\"1920\" height=\"1079\" \/><\/p>\n<p><a class=\"cta-primary\" href=\"https:\/\/tps-elektronik.com\/en\/services\/ems\/cable-assembly\/\">Explore TPS sensor cable assembly services \u2192<\/a><\/p>\n<\/section>\n<section id=\"shielding\">\n<h2>2. Shielding: Protecting the Weak Signal from Electrical Noise<\/h2>\n<p>Shielding is the first line of defense against electrical noise in temperature sensor cables. A shield\u2014typically a foil layer, a braided copper mesh, or both\u2014surrounds the signal conductors and intercepts electromagnetic fields before they can couple into the sensor signal.<\/p>\n<p>For RTD and thermocouple applications, there are several shielding options:<\/p>\n<ul>\n<li><strong>Foil shielding<\/strong> with a drain wire: An aluminum\/polyester foil tape wrapped around the conductors, with a bare copper drain wire in contact with the foil. Foil shielding provides 100% coverage and is effective against electrostatic fields.<\/li>\n<li><strong>Braided copper shielding<\/strong>: A woven mesh of tinned copper wires provides excellent low-resistance shielding and mechanical durability. Braided shields offer 85\u201395% coverage and are effective against both electrostatic and electromagnetic fields.<\/li>\n<li><strong>Combined foil and braid shielding<\/strong>: For the most demanding environments, a foil shield overlaid with a braided shield provides superior protection against both low-frequency and high-frequency interference.<\/li>\n<\/ul>\n<p>Industrial standards such as <strong>IEC 60584-3<\/strong> cover extension and compensating cables for thermocouples, including shielding requirements. While IEC 60751 for RTDs does not explicitly mandate shielding, the standard&#8217;s accuracy requirements can only maintained in electrically noisy environments with proper shielding practices. Leading automation manufacturers including Allen\u2011Bradley, Honeywell, Siemens, and Omega Engineering all recommend shielded twisted-pair cable for RTD connections.<\/p>\n<p>For <strong>shielded sensor cable<\/strong> applications, TPS Elektronik offers cables with foil shielding, braided shielding, or combined shielding\u2014selected based on the specific electromagnetic environment and the sensitivity of the measurement.<\/p>\n<\/section>\n<section id=\"twisted-pairs\">\n<h2>3. Twisted Pairs: Reducing Magnetic Field Coupling<\/h2>\n<p>Twisting the signal conductors together is a simple but highly effective technique for reducing magnetic field coupling. When two wires twisted, the loop area between them is minimized, and any magnetic field that couples into one twist cancelled by the opposite coupling in the adjacent twist.<\/p>\n<p>For RTD and thermocouple applications, <strong>shielded twisted-pair cable<\/strong> is the industry standard. The twisted pair provides rejection of magnetic fields, while the shield provides rejection of electric fields. Together, they form a robust defense against most common sources of industrial EMI.<\/p>\n<p>The benefits of twisted-pair construction for sensor cables include:<\/p>\n<ul>\n<li><strong>Up to 60 dB reduction in magnetic field induction:<\/strong> Twisted pairs dramatically reduce the pickup of magnetic fields from adjacent conductors and equipment<\/li>\n<li><strong>Common-mode noise rejection:<\/strong> Any noise that is coupled equally into both conductors appears as a common-mode signal that can be rejected by the differential input of the measurement instrument<\/li>\n<li><strong>Consistent impedance:<\/strong> Twisted pairs provide a defined, consistent impedance that maintains signal integrity over long cable runs<\/li>\n<\/ul>\n<p>For thermocouple applications, <strong>twisted thermocouple extension lead wire<\/strong> must be used to maintain the thermocouple&#8217;s accuracy over distance. The extension wire must be of the same thermocouple alloy type as the sensor (e.g., KX for Type K thermocouples) to avoid introducing additional thermoelectric voltages.<\/p>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-17328\" src=\"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/09\/Industrial-Temperature-Sensor-Installation-with-Shielded-Cable-Assembly-3-1.jpg\" alt=\"Industrial Temperature Sensor Installation with Shielded Cable Assembly Industrielle Temperatursensorinstallation mit geschirmter Kabelkonfektion\" width=\"1920\" height=\"1079\" \/><\/p>\n<\/section>\n<section id=\"grounding\">\n<h2>4. Grounding the Shield: One Point or Multiple?<\/h2>\n<p>While shielding protects against electric fields, improper shield grounding can introduce more noise than it removes\u2014through ground loops that inject 50\/60 Hz power-line noise onto the signal conductors.<\/p>\n<p>The standard practice for RTD and thermocouple circuits is to <strong>ground the shield at one end only<\/strong>\u2014typically at the control room, PLC, or acquisition instrument end\u2014and leave it floating at the sensor end. This single-point grounding prevents ground loops while still providing effective shielding.<\/p>\n<p>Key grounding guidelines for sensor cable assemblies:<\/p>\n<ul>\n<li><strong>Apply the shield with low resistance<\/strong>, enveloping the cable by 360\u00b0 at the entry point into the control cabinet<\/li>\n<li><strong>Earth the shield conductively<\/strong> at the entry point into the control cabinet or at the terminal connection point<\/li>\n<li><strong>Avoid unshielded cable lengths<\/strong> greater than 50 cm<\/li>\n<li><strong>For grounded sensors<\/strong>: ground the shield at the sensor end<\/li>\n<li><strong>For ungrounded sensors<\/strong>: ground the shield at the transmitter end<\/li>\n<\/ul>\n<p>The shield should be terminated with a <strong>360\u00b0 low-impedance connection<\/strong> to the ground reference\u2014a pigtail connection is not sufficient for high-frequency noise suppression. TPS Elektronik&#8217;s <strong>sensor cable assembly<\/strong> service includes proper shield termination options, with drain wires configured for single-point grounding per customer specifications.<\/p>\n<\/section>\n<section id=\"wire-configuration\">\n<h2>5. Wire Configuration: 2-Wire, 3-Wire, and 4-Wire RTD Connections<\/h2>\n<p>RTD sensors can connected in 2-wire, 3-wire, or 4-wire configurations, and the choice has a direct impact on measurement accuracy.<\/p>\n<p><strong>2-Wire Configuration:<\/strong> The simplest configuration uses two wires to connect the RTD to the measurement instrument. However, the lead wire resistance adds directly to the RTD resistance, creating an error that increases with cable length. For a 100 \u03a9 Pt RTD, every 0.385 \u03a9 of lead resistance represents a 1 \u00b0C error. 2-wire connections are generally not recommended for precision applications.<\/p>\n<p><strong>3-Wire Configuration:<\/strong> The 3-wire configuration is the industrial standard for most RTD applications. It uses three conductors: two for the current path and one for voltage sensing. By measuring the voltage drop across one current-carrying wire and assuming the other is identical, the instrument can compensate for lead resistance. A 3-wire setup provides accuracy close to a 4-wire setup and is widely used in industrial temperature transmitters from manufacturers including Endress+Hauser.<\/p>\n<p><strong>4-Wire Configuration:<\/strong> The 4-wire configuration provides the highest measurement accuracy by completely eliminating lead-wire resistance effects. Two wires carry the excitation current, and two separate wires sense the voltage across the RTD. Since the voltage-sensing wires carry negligible current, their resistance does not affect the measurement. 4-wire connections are typically used in laboratory and high-precision applications.<\/p>\n<p>For <strong>RTD thermocouple cable assembly<\/strong> applications, TPS Elektronik provides cable assemblies configured for 2-wire, 3-wire, or 4-wire operation\u2014with the appropriate conductor count, color coding, and termination to match the customer&#8217;s measurement instrument.<\/p>\n<\/section>\n<section id=\"materials-selection\">\n<h2>6. Materials Selection: Insulation, Jacket, and Temperature Rating<\/h2>\n<p>The materials used in a sensor cable assembly must match the application environment. Temperature extremes, chemical exposure, mechanical stress, and UV exposure all influence the choice of insulation and jacket materials.<\/p>\n<p><strong>Insulation Materials:<\/strong><\/p>\n<ul>\n<li><strong>PFA (Perfluoroalkoxy):<\/strong> Excellent high-temperature performance (up to 260\u00b0C), chemical resistance, and low dielectric constant. Suitable for demanding industrial and laboratory applications.<\/li>\n<li><strong>PTFE (Polytetrafluoroethylene):<\/strong> Superior temperature resistance (up to 260\u00b0C) and chemical inertness, but more expensive and less flexible than PFA.<\/li>\n<li><strong>PVC (Polyvinyl Chloride):<\/strong> Cost-effective for general-purpose applications up to 105\u00b0C, with good flexibility and abrasion resistance.<\/li>\n<li><strong>LSZH (Low Smoke Zero Halogen):<\/strong> Required for applications where smoke and toxic fumes are a concern, such as in enclosed spaces.<\/li>\n<\/ul>\n<p><strong>Jacket Materials:<\/strong><\/p>\n<ul>\n<li><strong>Polyurethane (PUR):<\/strong> Excellent abrasion resistance and flexibility, suitable for moving cable applications<\/li>\n<li><strong>PVC:<\/strong> General-purpose jacket with good durability and cost-effectiveness<\/li>\n<li><strong>PFA\/PTFE:<\/strong> High-temperature and chemical-resistant jackets for demanding environments<\/li>\n<li><strong>Stainless steel overbraid:<\/strong> For mechanical protection in high-abrasion or high-temperature applications<\/li>\n<\/ul>\n<p><strong>Temperature Rating:<\/strong> The cable&#8217;s temperature range must match the application. IEC 60584-3 defines temperature ranges for thermocouple extension cables, typically from -25\u00b0C to +200\u00b0C. However, the usable range may be restricted by the insulation material.<\/p>\n<p>TPS Elektronik provides <strong>sensor cable assembly<\/strong> services with a range of insulation and jacket materials to match application requirements\u2014from general-purpose PVC to high-temperature PFA and mechanically rugged stainless steel overbraid.<\/p>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-15371\" src=\"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/07\/\u7ebf\u675f\u52a0\u5de52.jpg\" alt=\"Cable Assembly\" width=\"1920\" height=\"960\" \/><\/p>\n<\/section>\n<section id=\"tps-capabilities\">\n<h2>7. TPS Sensor Cable Assembly Capabilities<\/h2>\n<p>TPS Elektronik&#8217;s <strong>sensor cable assembly<\/strong> service for RTD and thermocouple temperature sensors combines precision manufacturing, engineering support, and comprehensive quality assurance in a single integrated workflow.<\/p>\n<p><strong>Manufacturing Capabilities:<\/strong><\/p>\n<ul>\n<li><strong>Precision cutting and stripping:<\/strong> Automated cutting and stripping of shielded, twisted-pair sensor cables to exact lengths<\/li>\n<li><strong>Crimping and soldering:<\/strong> Controlled crimping and soldering processes for reliable electrical connections to sensor connectors and terminals<\/li>\n<li><strong>Shield termination:<\/strong> Proper shield termination with drain wires configured for single-point grounding<\/li>\n<li><strong>Sensor-specific configurations:<\/strong> 2-wire, 3-wire, and 4-wire RTD connections; thermocouple extension cables with matching alloy types (KX, JX, TX, EX, NX)<\/li>\n<li><strong>Connector options:<\/strong> M12, Lemo, thermocouple compensation plugs, and custom connectors<\/li>\n<li><strong>Labeling and identification:<\/strong> Clear labeling for installation clarity and traceability<\/li>\n<\/ul>\n<p><strong>Engineering Support:<\/strong><\/p>\n<ul>\n<li><strong>DFM feedback:<\/strong> Design optimization for manufacturability and reliability<\/li>\n<li><strong>Cable and connector selection:<\/strong> Guidance based on temperature range, chemical exposure, and mechanical requirements<\/li>\n<li><strong>Color code compliance:<\/strong> IEC 60584-3 and ANSI MC96.1 color coding for thermocouple extension cables<\/li>\n<li><strong>Length optimization:<\/strong> Balancing signal integrity and mechanical constraints<\/li>\n<\/ul>\n<p><strong>Quality and Testing:<\/strong><\/p>\n<ul>\n<li><strong>100% continuity testing:<\/strong> Every conductor in every assembly verified for continuity and correct pin mapping<\/li>\n<li><strong>Shielding effectiveness verification:<\/strong> Visual and electrical verification of shield termination integrity<\/li>\n<li><strong>Insulation resistance testing:<\/strong> Verification of insulation integrity per applicable standards<\/li>\n<li><strong>First Article Inspection (FAI):<\/strong> Comprehensive dimensional reports for the first part of each production run<\/li>\n<li><strong>Documentation:<\/strong> Material certificates, test reports, and traceability documentation<\/li>\n<\/ul>\n<p>TPS Elektronik&#8217;s <strong>sensor cable assembly<\/strong> service is part of a broader EMS workflow, integrating cable assembly with PCB assembly and system integration\u2014reducing supply chain complexity for system integrators and procurement teams.<\/p>\n<p><a class=\"cta-primary\" href=\"https:\/\/tps-elektronik.com\/en\/services\/ems\/cable-assembly\/\">Request your sensor cable assembly RFQ in 24\u201348 hours \u2192<\/a><\/p>\n<\/section>\n<section id=\"faq\">\n<h2>8. FAQ<\/h2>\n<div>\n<div>\n<h3>What type of cable should be used for RTD temperature sensors in industrial environments?<\/h3>\n<div>\n<div>Industry best practice\u2014supported by manufacturers including Allen-Bradley, Honeywell, Siemens, and Omega Engineering\u2014is to use shielded twisted-pair cable for RTD connections. The twisted pair rejects magnetic fields, and the shield protects against electric fields. Cable selection should consider temperature rating, chemical exposure, and mechanical requirements.<\/div>\n<\/div>\n<\/div>\n<div>\n<h3>How should the shield of a sensor cable be grounded?<\/h3>\n<div>\n<div>The shield should be grounded at one end only\u2014typically at the control room, PLC, or acquisition instrument end\u2014and left floating at the sensor end. This single-point grounding prevents ground loops that can introduce 50\/60 Hz power-line noise onto the signal conductors. The shield should be terminated with a 360\u00b0 low-impedance connection.<\/div>\n<\/div>\n<\/div>\n<div>\n<h3>What is the difference between 3-wire and 4-wire RTD connections?<\/h3>\n<div>\n<div>3-wire RTD connections are the industrial standard, providing lead resistance compensation by measuring the voltage drop across one current-carrying wire and assuming the other is identical. 4-wire connections provide the highest accuracy by completely eliminating lead-wire resistance effects, using separate wires for current excitation and voltage sensing.<\/div>\n<\/div>\n<\/div>\n<div>\n<h3>What is a thermocouple extension cable and why is it important?<\/h3>\n<div>\n<div>A thermocouple extension cable is made from the same thermocouple alloy types as the sensor (e.g., KX for Type K thermocouples) and is used to extend the thermocouple circuit over distance without introducing additional thermoelectric voltages. IEC 60584-3 defines the identification, color coding, and tolerances for thermocouple extension and compensating cables.<\/div>\n<\/div>\n<\/div>\n<div>\n<h3>Can TPS provide custom sensor cable assemblies with specific connectors?<\/h3>\n<div>\n<div>Yes. TPS manufactures custom sensor cable assemblies with a range of connector options including M12, Lemo, thermocouple compensation plugs, and custom connectors. Engineering support is provided for connector selection and cable configuration optimization.<\/div>\n<\/div>\n<\/div>\n<div>\n<h3>What documentation does TPS provide for sensor cable assemblies?<\/h3>\n<div>\n<div>TPS provides First Article Inspection (FAI) with dimensional reports, material certificates, 100% continuity test reports, and insulation resistance test results. Full traceability documentation is available on request.<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/section>\n<footer style=\"background: #2d5797; padding: 30px; border-radius: 14px; margin-top: 40px;\">\n<p style=\"color: #ffffff; font-size: 16px; line-height: 1.6; margin: 0;\"><strong>Ready to ensure accurate signal transmission from your RTD and thermocouple sensors?<\/strong><br \/>Contact TPS Elektronik for engineering consultation, prototype evaluation, and production support\u2014from shielded sensor cable assembly to integrated EMS solutions.<br \/><a style=\"color: #ffffff; font-weight: 600; text-decoration: underline;\" href=\"https:\/\/tps-elektronik.com\/en\/services\/ems\/cable-assembly\/\">Request your sensor cable assembly quote \u2192<\/a><\/p>\n<\/footer><\/article>\n\n<style id=\"wpforms-css-vars-4659-block-3566ceca-ea80-4817-a75a-ad24aba92323\">\n\t\t\t\t#wpforms-4659.wpforms-block-3566ceca-ea80-4817-a75a-ad24aba92323 {\n\t\t\t\t--wpforms-field-size-input-height: 43px;\n--wpforms-field-size-input-spacing: 15px;\n--wpforms-field-size-font-size: 16px;\n--wpforms-field-size-line-height: 19px;\n--wpforms-field-size-padding-h: 14px;\n--wpforms-field-size-checkbox-size: 16px;\n--wpforms-field-size-sublabel-spacing: 5px;\n--wpforms-field-size-icon-size: 1;\n--wpforms-label-size-font-size: 16px;\n--wpforms-label-size-line-height: 19px;\n--wpforms-label-size-sublabel-font-size: 14px;\n--wpforms-label-size-sublabel-line-height: 17px;\n--wpforms-button-size-font-size: 17px;\n--wpforms-button-size-height: 41px;\n--wpforms-button-size-padding-h: 15px;\n--wpforms-button-size-margin-top: 10px;\n\t\t\t}\n\t\t\t<\/style><div class=\"wpforms-container wpforms-container-full wpforms-block wpforms-block-3566ceca-ea80-4817-a75a-ad24aba92323 wpforms-render-modern\" id=\"wpforms-4659\"><form id=\"wpforms-form-4659\" class=\"wpforms-validate wpforms-form wpforms-ajax-form\" data-formid=\"4659\" method=\"post\" enctype=\"multipart\/form-data\" action=\"\/en\/wp-json\/wp\/v2\/posts\/17247\" data-token=\"3dd2f88464bdb42dcdeaa29377fa3f43\" data-token-time=\"1790074673\"><noscript class=\"wpforms-error-noscript\">Please enable JavaScript in your browser to complete this form.<\/noscript><div id=\"wpforms-error-noscript\" style=\"display: none;\">Please enable JavaScript in your browser to complete this form.<\/div><div class=\"wpforms-field-container\"><div id=\"wpforms-4659-field_1-container\" class=\"wpforms-field wpforms-field-name\" data-field-id=\"1\"><fieldset><legend class=\"wpforms-field-label\">Name <span class=\"wpforms-required-label\" aria-hidden=\"true\">*<\/span><\/legend><div class=\"wpforms-field-row wpforms-field-large\"><div class=\"wpforms-field-row-block wpforms-first wpforms-one-half\"><input type=\"text\" id=\"wpforms-4659-field_1\" class=\"wpforms-field-name-first wpforms-field-required\" name=\"wpforms[fields][1][first]\" aria-errormessage=\"wpforms-4659-field_1-error\" required><label for=\"wpforms-4659-field_1\" class=\"wpforms-field-sublabel after\">First<\/label><\/div><div class=\"wpforms-field-row-block wpforms-one-half\"><input type=\"text\" id=\"wpforms-4659-field_1-last\" class=\"wpforms-field-name-last wpforms-field-required\" name=\"wpforms[fields][1][last]\" aria-errormessage=\"wpforms-4659-field_1-last-error\" required><label for=\"wpforms-4659-field_1-last\" class=\"wpforms-field-sublabel after\">Last<\/label><\/div><\/div><\/fieldset><\/div><div id=\"wpforms-4659-field_4-container\" class=\"wpforms-field wpforms-field-text\" data-field-id=\"4\"><label class=\"wpforms-field-label\" for=\"wpforms-4659-field_4\">Company <span class=\"wpforms-required-label\" aria-hidden=\"true\">*<\/span><\/label><input type=\"text\" id=\"wpforms-4659-field_4\" class=\"wpforms-field-large wpforms-field-required\" name=\"wpforms[fields][4]\" aria-errormessage=\"wpforms-4659-field_4-error\" required><\/div><div id=\"wpforms-4659-field_2-container\" class=\"wpforms-field wpforms-field-email\" data-field-id=\"2\"><label class=\"wpforms-field-label\" for=\"wpforms-4659-field_2\">Email <span class=\"wpforms-required-label\" aria-hidden=\"true\">*<\/span><\/label><input type=\"email\" id=\"wpforms-4659-field_2\" class=\"wpforms-field-large wpforms-field-required\" name=\"wpforms[fields][2]\" spellcheck=\"false\" aria-errormessage=\"wpforms-4659-field_2-error\" required><\/div>\t\t<div id=\"wpforms-4659-field_5-container\"\n\t\t\tclass=\"wpforms-field wpforms-field-text\"\n\t\t\tdata-field-type=\"text\"\n\t\t\tdata-field-id=\"5\"\n\t\t\t>\n\t\t\t<label class=\"wpforms-field-label\" for=\"wpforms-4659-field_5\" >Email Checkbox Message<\/label>\n\t\t\t<input type=\"text\" id=\"wpforms-4659-field_5\" class=\"wpforms-field-medium\" name=\"wpforms[fields][5]\" >\n\t\t<\/div>\n\t\t<div id=\"wpforms-4659-field_3-container\" class=\"wpforms-field wpforms-field-textarea\" data-field-id=\"3\"><label class=\"wpforms-field-label\" for=\"wpforms-4659-field_3\">Comment or Message<\/label><textarea id=\"wpforms-4659-field_3\" class=\"wpforms-field-medium\" name=\"wpforms[fields][3]\" aria-errormessage=\"wpforms-4659-field_3-error\" ><\/textarea><\/div><div id=\"wpforms-4659-field_6-container\" class=\"wpforms-field wpforms-field-checkbox\" data-field-id=\"6\"><fieldset><legend class=\"wpforms-field-label wpforms-label-hide\" aria-hidden=\"false\">Checkbox <span class=\"wpforms-required-label\" aria-hidden=\"true\">*<\/span><\/legend><ul id=\"wpforms-4659-field_6\" class=\"wpforms-field-required\"><li class=\"choice-1 depth-1 wpforms-selected\"><input type=\"checkbox\" id=\"wpforms-4659-field_6_1\" name=\"wpforms[fields][6][]\" value=\"I agree to the processing of my information for the purpose of creating a quote.\" aria-errormessage=\"wpforms-4659-field_6_1-error\" aria-describedby=\"wpforms-4659-field_6-description\" required  checked='checked'><label class=\"wpforms-field-label-inline\" for=\"wpforms-4659-field_6_1\">I agree to the processing of my information for the purpose of creating a quote.<\/label><\/li><\/ul><div id=\"wpforms-4659-field_6-description\" class=\"wpforms-field-description\">For information see Privacy.<\/div><\/fieldset><\/div><script>\n\t\t\t\t( function() {\n\t\t\t\t\tconst style = document.createElement( 'style' );\n\t\t\t\t\tstyle.appendChild( document.createTextNode( '#wpforms-4659-field_5-container { position: absolute !important; overflow: hidden !important; display: inline !important; height: 1px !important; width: 1px !important; z-index: -1000 !important; padding: 0 !important; } #wpforms-4659-field_5-container input { visibility: hidden; } #wpforms-conversational-form-page #wpforms-4659-field_5-container label { counter-increment: none; }' ) );\n\t\t\t\t\tdocument.head.appendChild( style );\n\t\t\t\t\tdocument.currentScript?.remove();\n\t\t\t\t} )();\n\t\t\t<\/script><\/div><!-- .wpforms-field-container --><div class=\"wpforms-submit-container\" ><input type=\"hidden\" name=\"wpforms[id]\" value=\"4659\"><input type=\"hidden\" name=\"page_title\" value=\"\"><input type=\"hidden\" name=\"page_url\" value=\"https:\/\/tps-elektronik.com\/en\/wp-json\/wp\/v2\/posts\/17247\"><input type=\"hidden\" name=\"url_referer\" value=\"\"><button type=\"submit\" name=\"wpforms[submit]\" id=\"wpforms-submit-4659\" class=\"wpforms-submit\" data-alt-text=\"Sending...\" data-submit-text=\"Submit\" aria-live=\"assertive\" value=\"wpforms-submit\">Submit<\/button><img decoding=\"async\" src=\"https:\/\/tps-elektronik.com\/wp-content\/plugins\/wpforms-lite\/assets\/images\/submit-spin.svg\" class=\"wpforms-submit-spinner\" style=\"display: none;\" width=\"26\" height=\"26\" alt=\"Loading\"><\/div><\/form><\/div>  <!-- .wpforms-container -->","protected":false},"excerpt":{"rendered":"<p>For system integrators, panel builders, and electrical engineers working with industrial temperature measurement, the cable connecting an RTD or thermocouple sensor to the control system is not a passive component\u2014it is an active part of the measurement chain. A poorly chosen or improperly assembled cable can introduce errors that compromise process control, product quality, and\u2026 <a href=\"https:\/\/tps-elektronik.com\/en\/how-to-ensure-accurate-signal-transmission-in-industrial-rtd-and-thermocouple-temperature-sensors-with-tps-shielded-sensor-cable-assembly\/\">Read More &raquo;<\/a><\/p>\n","protected":false},"author":9,"featured_media":17333,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[57],"tags":[],"class_list":["post-17247","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog-content"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.5 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>How to Ensure Accurate Signal Transmission in Industrial RTD and Thermocouple Temperature Sensors with TPS Shielded Sensor Cable Assembly? - TPS<\/title>\n<meta name=\"description\" content=\"Sensor cable assembly for RTD and thermocouple sensors with shielding, twisted pairs, and full traceability for industrial temperature measurement.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/tps-elektronik.com\/en\/how-to-ensure-accurate-signal-transmission-in-industrial-rtd-and-thermocouple-temperature-sensors-with-tps-shielded-sensor-cable-assembly\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"How to Ensure Accurate Signal Transmission in Industrial RTD and Thermocouple Temperature Sensors with TPS Shielded Sensor Cable Assembly? - TPS\" \/>\n<meta property=\"og:description\" content=\"Sensor cable assembly for RTD and thermocouple sensors with shielding, twisted pairs, and full traceability for industrial temperature measurement.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/tps-elektronik.com\/en\/how-to-ensure-accurate-signal-transmission-in-industrial-rtd-and-thermocouple-temperature-sensors-with-tps-shielded-sensor-cable-assembly\/\" \/>\n<meta property=\"og:site_name\" content=\"TPS\" \/>\n<meta property=\"article:published_time\" content=\"2026-09-22T07:00:00+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/09\/RTD-2-Wire-3-Wire-4-Wire-Connection-Configurations-2-1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1920\" \/>\n\t<meta property=\"og:image:height\" content=\"1079\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Tang Marcus\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Tang Marcus\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"11 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/how-to-ensure-accurate-signal-transmission-in-industrial-rtd-and-thermocouple-temperature-sensors-with-tps-shielded-sensor-cable-assembly\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/how-to-ensure-accurate-signal-transmission-in-industrial-rtd-and-thermocouple-temperature-sensors-with-tps-shielded-sensor-cable-assembly\\\/\"},\"author\":{\"name\":\"Tang Marcus\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/#\\\/schema\\\/person\\\/2c19fd053095d0c1ae253e8e62427b8c\"},\"headline\":\"How to Ensure Accurate Signal Transmission in Industrial RTD and Thermocouple Temperature Sensors with TPS Shielded Sensor Cable Assembly?\",\"datePublished\":\"2026-09-22T07:00:00+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/how-to-ensure-accurate-signal-transmission-in-industrial-rtd-and-thermocouple-temperature-sensors-with-tps-shielded-sensor-cable-assembly\\\/\"},\"wordCount\":2135,\"image\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/how-to-ensure-accurate-signal-transmission-in-industrial-rtd-and-thermocouple-temperature-sensors-with-tps-shielded-sensor-cable-assembly\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/tps-elektronik.com\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/RTD-2-Wire-3-Wire-4-Wire-Connection-Configurations-2-1.jpg\",\"articleSection\":[\"Blog Content\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/how-to-ensure-accurate-signal-transmission-in-industrial-rtd-and-thermocouple-temperature-sensors-with-tps-shielded-sensor-cable-assembly\\\/\",\"url\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/how-to-ensure-accurate-signal-transmission-in-industrial-rtd-and-thermocouple-temperature-sensors-with-tps-shielded-sensor-cable-assembly\\\/\",\"name\":\"How to Ensure Accurate Signal Transmission in Industrial RTD and Thermocouple Temperature Sensors with TPS Shielded Sensor Cable Assembly? - TPS\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/how-to-ensure-accurate-signal-transmission-in-industrial-rtd-and-thermocouple-temperature-sensors-with-tps-shielded-sensor-cable-assembly\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/how-to-ensure-accurate-signal-transmission-in-industrial-rtd-and-thermocouple-temperature-sensors-with-tps-shielded-sensor-cable-assembly\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/tps-elektronik.com\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/RTD-2-Wire-3-Wire-4-Wire-Connection-Configurations-2-1.jpg\",\"datePublished\":\"2026-09-22T07:00:00+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/#\\\/schema\\\/person\\\/2c19fd053095d0c1ae253e8e62427b8c\"},\"description\":\"Sensor cable assembly for RTD and thermocouple sensors with shielding, twisted pairs, and full traceability for industrial temperature measurement.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/how-to-ensure-accurate-signal-transmission-in-industrial-rtd-and-thermocouple-temperature-sensors-with-tps-shielded-sensor-cable-assembly\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/how-to-ensure-accurate-signal-transmission-in-industrial-rtd-and-thermocouple-temperature-sensors-with-tps-shielded-sensor-cable-assembly\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/how-to-ensure-accurate-signal-transmission-in-industrial-rtd-and-thermocouple-temperature-sensors-with-tps-shielded-sensor-cable-assembly\\\/#primaryimage\",\"url\":\"https:\\\/\\\/tps-elektronik.com\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/RTD-2-Wire-3-Wire-4-Wire-Connection-Configurations-2-1.jpg\",\"contentUrl\":\"https:\\\/\\\/tps-elektronik.com\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/RTD-2-Wire-3-Wire-4-Wire-Connection-Configurations-2-1.jpg\",\"width\":1920,\"height\":1079,\"caption\":\"RTD 2-Wire 3-Wire 4-Wire Connection Configurations RTD-Anschlusskonfigurationen: 2-Draht, 3-Draht, 4-Draht\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/how-to-ensure-accurate-signal-transmission-in-industrial-rtd-and-thermocouple-temperature-sensors-with-tps-shielded-sensor-cable-assembly\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Startseite\",\"item\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"How to Ensure Accurate Signal Transmission in Industrial RTD and Thermocouple Temperature Sensors with TPS Shielded Sensor Cable Assembly?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/\",\"name\":\"TPS\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/#\\\/schema\\\/person\\\/2c19fd053095d0c1ae253e8e62427b8c\",\"name\":\"Tang Marcus\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"How to Ensure Accurate Signal Transmission in Industrial RTD and Thermocouple Temperature Sensors with TPS Shielded Sensor Cable Assembly? - TPS","description":"Sensor cable assembly for RTD and thermocouple sensors with shielding, twisted pairs, and full traceability for industrial temperature measurement.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/tps-elektronik.com\/en\/how-to-ensure-accurate-signal-transmission-in-industrial-rtd-and-thermocouple-temperature-sensors-with-tps-shielded-sensor-cable-assembly\/","og_locale":"en_US","og_type":"article","og_title":"How to Ensure Accurate Signal Transmission in Industrial RTD and Thermocouple Temperature Sensors with TPS Shielded Sensor Cable Assembly? - TPS","og_description":"Sensor cable assembly for RTD and thermocouple sensors with shielding, twisted pairs, and full traceability for industrial temperature measurement.","og_url":"https:\/\/tps-elektronik.com\/en\/how-to-ensure-accurate-signal-transmission-in-industrial-rtd-and-thermocouple-temperature-sensors-with-tps-shielded-sensor-cable-assembly\/","og_site_name":"TPS","article_published_time":"2026-09-22T07:00:00+00:00","og_image":[{"width":1920,"height":1079,"url":"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/09\/RTD-2-Wire-3-Wire-4-Wire-Connection-Configurations-2-1.jpg","type":"image\/jpeg"}],"author":"Tang Marcus","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Tang Marcus","Est. reading time":"11 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/tps-elektronik.com\/en\/how-to-ensure-accurate-signal-transmission-in-industrial-rtd-and-thermocouple-temperature-sensors-with-tps-shielded-sensor-cable-assembly\/#article","isPartOf":{"@id":"https:\/\/tps-elektronik.com\/en\/how-to-ensure-accurate-signal-transmission-in-industrial-rtd-and-thermocouple-temperature-sensors-with-tps-shielded-sensor-cable-assembly\/"},"author":{"name":"Tang Marcus","@id":"https:\/\/tps-elektronik.com\/en\/#\/schema\/person\/2c19fd053095d0c1ae253e8e62427b8c"},"headline":"How to Ensure Accurate Signal Transmission in Industrial RTD and Thermocouple Temperature Sensors with TPS Shielded Sensor Cable Assembly?","datePublished":"2026-09-22T07:00:00+00:00","mainEntityOfPage":{"@id":"https:\/\/tps-elektronik.com\/en\/how-to-ensure-accurate-signal-transmission-in-industrial-rtd-and-thermocouple-temperature-sensors-with-tps-shielded-sensor-cable-assembly\/"},"wordCount":2135,"image":{"@id":"https:\/\/tps-elektronik.com\/en\/how-to-ensure-accurate-signal-transmission-in-industrial-rtd-and-thermocouple-temperature-sensors-with-tps-shielded-sensor-cable-assembly\/#primaryimage"},"thumbnailUrl":"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/09\/RTD-2-Wire-3-Wire-4-Wire-Connection-Configurations-2-1.jpg","articleSection":["Blog Content"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/tps-elektronik.com\/en\/how-to-ensure-accurate-signal-transmission-in-industrial-rtd-and-thermocouple-temperature-sensors-with-tps-shielded-sensor-cable-assembly\/","url":"https:\/\/tps-elektronik.com\/en\/how-to-ensure-accurate-signal-transmission-in-industrial-rtd-and-thermocouple-temperature-sensors-with-tps-shielded-sensor-cable-assembly\/","name":"How to Ensure Accurate Signal Transmission in Industrial RTD and Thermocouple Temperature Sensors with TPS Shielded Sensor Cable Assembly? - TPS","isPartOf":{"@id":"https:\/\/tps-elektronik.com\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/tps-elektronik.com\/en\/how-to-ensure-accurate-signal-transmission-in-industrial-rtd-and-thermocouple-temperature-sensors-with-tps-shielded-sensor-cable-assembly\/#primaryimage"},"image":{"@id":"https:\/\/tps-elektronik.com\/en\/how-to-ensure-accurate-signal-transmission-in-industrial-rtd-and-thermocouple-temperature-sensors-with-tps-shielded-sensor-cable-assembly\/#primaryimage"},"thumbnailUrl":"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/09\/RTD-2-Wire-3-Wire-4-Wire-Connection-Configurations-2-1.jpg","datePublished":"2026-09-22T07:00:00+00:00","author":{"@id":"https:\/\/tps-elektronik.com\/en\/#\/schema\/person\/2c19fd053095d0c1ae253e8e62427b8c"},"description":"Sensor cable assembly for RTD and thermocouple sensors with shielding, twisted pairs, and full traceability for industrial temperature measurement.","breadcrumb":{"@id":"https:\/\/tps-elektronik.com\/en\/how-to-ensure-accurate-signal-transmission-in-industrial-rtd-and-thermocouple-temperature-sensors-with-tps-shielded-sensor-cable-assembly\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/tps-elektronik.com\/en\/how-to-ensure-accurate-signal-transmission-in-industrial-rtd-and-thermocouple-temperature-sensors-with-tps-shielded-sensor-cable-assembly\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/tps-elektronik.com\/en\/how-to-ensure-accurate-signal-transmission-in-industrial-rtd-and-thermocouple-temperature-sensors-with-tps-shielded-sensor-cable-assembly\/#primaryimage","url":"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/09\/RTD-2-Wire-3-Wire-4-Wire-Connection-Configurations-2-1.jpg","contentUrl":"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/09\/RTD-2-Wire-3-Wire-4-Wire-Connection-Configurations-2-1.jpg","width":1920,"height":1079,"caption":"RTD 2-Wire 3-Wire 4-Wire Connection Configurations RTD-Anschlusskonfigurationen: 2-Draht, 3-Draht, 4-Draht"},{"@type":"BreadcrumbList","@id":"https:\/\/tps-elektronik.com\/en\/how-to-ensure-accurate-signal-transmission-in-industrial-rtd-and-thermocouple-temperature-sensors-with-tps-shielded-sensor-cable-assembly\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Startseite","item":"https:\/\/tps-elektronik.com\/en\/"},{"@type":"ListItem","position":2,"name":"How to Ensure Accurate Signal Transmission in Industrial RTD and Thermocouple Temperature Sensors with TPS Shielded Sensor Cable Assembly?"}]},{"@type":"WebSite","@id":"https:\/\/tps-elektronik.com\/en\/#website","url":"https:\/\/tps-elektronik.com\/en\/","name":"TPS","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/tps-elektronik.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/tps-elektronik.com\/en\/#\/schema\/person\/2c19fd053095d0c1ae253e8e62427b8c","name":"Tang Marcus"}]}},"_links":{"self":[{"href":"https:\/\/tps-elektronik.com\/en\/wp-json\/wp\/v2\/posts\/17247","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/tps-elektronik.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/tps-elektronik.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/tps-elektronik.com\/en\/wp-json\/wp\/v2\/users\/9"}],"replies":[{"embeddable":true,"href":"https:\/\/tps-elektronik.com\/en\/wp-json\/wp\/v2\/comments?post=17247"}],"version-history":[{"count":2,"href":"https:\/\/tps-elektronik.com\/en\/wp-json\/wp\/v2\/posts\/17247\/revisions"}],"predecessor-version":[{"id":17339,"href":"https:\/\/tps-elektronik.com\/en\/wp-json\/wp\/v2\/posts\/17247\/revisions\/17339"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/tps-elektronik.com\/en\/wp-json\/wp\/v2\/media\/17333"}],"wp:attachment":[{"href":"https:\/\/tps-elektronik.com\/en\/wp-json\/wp\/v2\/media?parent=17247"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/tps-elektronik.com\/en\/wp-json\/wp\/v2\/categories?post=17247"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/tps-elektronik.com\/en\/wp-json\/wp\/v2\/tags?post=17247"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}