{"id":14136,"date":"2026-06-11T09:30:00","date_gmt":"2026-06-11T07:30:00","guid":{"rendered":"https:\/\/tps-elektronik.com\/?p=14136"},"modified":"2026-06-01T10:48:00","modified_gmt":"2026-06-01T08:48:00","slug":"introduction-capturing-high-frequency-transient-current-in-electric-vehicle-and-switching-power-supply-designs","status":"publish","type":"post","link":"https:\/\/tps-elektronik.com\/en\/introduction-capturing-high-frequency-transient-current-in-electric-vehicle-and-switching-power-supply-designs\/","title":{"rendered":"Introduction: Capturing High-Frequency Transient Current in Electric Vehicle and Switching Power Supply Designs"},"content":{"rendered":"\n<p>When designing an Electric vehicle transportation design or a Switching power supply design, engineers often face a critical challenge: how to accurately measure fast, high-frequency transient currents. Whether you are dealing with MOSFET switching spikes, inductor inrush currents, or PWM ripple, the right oscilloscope probe is essential. A standard current probe may not provide the bandwidth or sensitivity needed. In many cases, a differential probe or a hi voltage solution combined with a high voltage probe is used for voltage measurements, but for current, you need a dedicated test probe such as a current clamp probe for oscilloscope. But what is the best approach? Understanding oscilloscope what is its role in power electronics leads us to the scope current probe. Specifically, a <a href=\"https:\/\/www.shop-tps.com\/shop\/current-proble-cp503b-28051?category=141\" type=\"link\" id=\"https:\/\/www.shop-tps.com\/shop\/current-proble-cp503b-28051?category=141\" target=\"_blank\" rel=\"noopener noreferrer nofollow\">High Frequency AC DC Current Probe<\/a> is the ideal tool for these applications. This article will guide you through the challenges of measuring high-frequency transient currents, how to measure high frequency current signal accurately, how to measure surge current during startup, and how to solve low frequency probe distortion. <\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1536\" height=\"1024\" src=\"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/06\/Current-proble-20260601-1.jpg\" alt=\"Measuring high-frequency transient current in an electric vehicle inverter using a clamp probe.\" class=\"wp-image-14138\" srcset=\"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/06\/Current-proble-20260601-1.jpg 1536w, https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/06\/Current-proble-20260601-1-600x400.jpg 600w\" sizes=\"(max-width: 1536px) 100vw, 1536px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>The Core Problem: Bandwidth Limitation and Low-Frequency Probe Distortion<\/strong><\/h3>\n\n\n\n<p>Many engineers start with a general-purpose current clamp probe for oscilloscope that works well for 50\/60 Hz power lines or low-speed motor currents. However, when faced with fast switching edges (rise times &lt; 50 ns) found in modern <a href=\"https:\/\/ieeexplore.ieee.org\/document\/10388225\" type=\"link\" id=\"https:\/\/ieeexplore.ieee.org\/document\/10388225\" target=\"_blank\" rel=\"noopener noreferrer nofollow\">GaN or SiC power stages<\/a>, such probes produce severe waveform distortion. This is because their bandwidth is often limited to a few hundred kHz. As a result, you cannot measure high frequency current signal properly. The waveform appears rounded, delayed, or completely reshaped. This low frequency probe distortion leads to incorrect calculations of switching losses, false conclusions about EMI, and ultimately unreliable designs. To solve low frequency probe distortion, you need a probe with at least 50 MHz to 100 MHz bandwidth, fast rise time, and flat response over the frequency range of interest. A High Frequency AC DC Current Probe like those used in professional power electronics labs achieves exactly that.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1536\" height=\"1024\" src=\"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/06\/Current-proble-20260601-2.jpg\" alt=\"Comparison: low frequency probe distortion (blue) vs. high-frequency probe (yellow).\" class=\"wp-image-14143\" srcset=\"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/06\/Current-proble-20260601-2.jpg 1536w, https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/06\/Current-proble-20260601-2-600x400.jpg 600w\" sizes=\"(max-width: 1536px) 100vw, 1536px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Dual Range Selection \u2013 Measuring Both Large Surge and Small Ripple<\/strong><\/h3>\n\n\n\n<p>One of the most practical features in modern probes is the Dual range selection current probe. Power electronics often require measuring a wide dynamic range: from tens of milliamps of idle current to tens of amps of peak surge current. A single fixed gain would either saturate on large signals or have insufficient sensitivity for small currents. With dual ranges (e.g., 6A and 30A), you can measure low current easily in the sensitive range (e.g., 1V\/2A output) and then switch to the high range (e.g., 1V\/10A) for capturing inrush or overload events. This capability directly helps reduce measurement error because the signal-to-noise ratio is optimized for each amplitude. Key features include:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Dual range selection current probe: 6A (high sensitivity) and 30A (high current) ranges, selectable by a front-panel button.<\/li>\n\n\n\n<li>Output sensitivity: 1V\/2A (6A range) and 1V\/10A (30A range), compatible with any 1M\u03a9 BNC input oscilloscope.<\/li>\n\n\n\n<li>Ability to measure surge current up to 30A peak (60A peak-to-peak) without saturation.<\/li>\n\n\n\n<li>Low current resolution: down to 20 mA in 6A range, enabling idle current monitoring in standby modes.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Degaussing and Automatic Zero Setting \u2013 Eliminate DC Offset and Remanence<\/strong><\/h3>\n\n\n\n<p>Current probes that use a Hall effect sensor (for DC) and a coil (for AC) suffer from two common artifacts: remanent magnetism (core memory) and thermal drift of the Hall element. This results in a non-zero output even when no current flows, causing measurement errors especially at low currents. A Degaussing current probe solves the first problem by applying a decaying alternating magnetic field to demagnetize the core. A Automatic Zero setting current probe then compensates for any remaining offset. With a single press of the &#8220;Zero&#8221; button, the probe performs both degaussing and auto-zero, ensuring accuracy before each critical measurement. This is indispensable when you need to reduce measurement error to \u00b11% or better. Key features:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Degaussing current probe with built-in degaussing coil \u2013 no external degausser required.<\/li>\n\n\n\n<li>Automatic Zero setting current probe \u2013 one-button operation, LED indicator shows zeroing complete.<\/li>\n\n\n\n<li>DC accuracy: \u00b11% \u00b110 mA (6A range) \/ \u00b11% \u00b150 mA (30A range) typical.<\/li>\n\n\n\n<li>Noise: \u2264 1.4 mA RMS (bandwidth limited to 20 MHz) \u2013 essential for clean low-current readings.<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1536\" height=\"1024\" src=\"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/06\/Current-proble-20260601-3.jpg\" alt=\"Image of the current probe body\" class=\"wp-image-14148\" srcset=\"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/06\/Current-proble-20260601-3.jpg 1536w, https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/06\/Current-proble-20260601-3-600x400.jpg 600w\" sizes=\"(max-width: 1536px) 100vw, 1536px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>BNC Interface and Universal Compatibility<\/strong><\/h3>\n\n\n\n<p>Unlike specialized probes that require proprietary connectors or external power supplies, a BNC interface current probe offers universal compatibility. Any oscilloscope with a standard BNC input (which is nearly all scopes) can directly accept the probe\u2019s output. Furthermore, the probe is powered by a DC 5V\/3A supply (often via USB or an included adapter), so there is no need for a dedicated probe interface. When you ask oscilloscope what is its most common input interface \u2013 the answer is BNC. Therefore, using a BNC interface current probe ensures that you can quickly move between different oscilloscopes in the lab. This feature is especially valuable in Experiment of electronic engineering and Power electronics experimental design environments where multiple test stations exist. Key benefits:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>BNC interface current probe \u2013 plug-and-play with any 1 M\u03a9 oscilloscope input.<\/li>\n\n\n\n<li>Low output impedance (50\u03a9 typical) and short delay (&lt;30 ns) ensures accurate timing alignment with voltage probes.<\/li>\n\n\n\n<li>No calibration box or complex setup \u2013 simply connect, degauss\/zero, and measure.<\/li>\n\n\n\n<li>Overload indicator (flashing LED) warns when input current exceeds the selected range.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Applications Across Industries and Research Fields<\/strong><\/h3>\n\n\n\n<p>With the capabilities described above, a High Frequency AC DC Current Probe becomes an essential tool across many domains. In Electric vehicle transportation design, it captures motor phase currents and DC-link ripple. In Switching power supply design, it measures inductor currents and switch node transients. Semiconductor devices design benefits from accurate characterization of dynamic on-resistance and switching loss. Avionics design requires reliable current monitoring in harsh electrical environments. Inverter design and Transformer design both need wide-bandwidth current probes to analyze core saturation and leakage inductance effects. Electronic ballast design for lighting relies on high-frequency current measurement to ensure proper lamp striking and steady-state operation. Industrial Control design and Consumer Electronics design use these probes for power integrity and standby power optimization. Engine driven design (e.g., hybrid vehicles) and Electric drive experimental design rely on accurate current feedback for control loop tuning. The probe is also a standard tool in university Experiment of electronic engineering courses and Power electronics experimental design labs.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Specification Summary (Example: 50 MHz \/ 100 MHz Class Probe)<\/strong><\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Parameter<\/th><th>Value<\/th><\/tr><\/thead><tbody><tr><td>Bandwidth (\u20133dB)<\/td><td>50 MHz \/ 100 MHz<\/td><\/tr><tr><td>Rise Time<\/td><td>\u22647 ns \/ \u22643.5 ns<\/td><\/tr><tr><td>Ranges<\/td><td>6A (high sensitivity), 30A (high current)<\/td><\/tr><tr><td>Output Sensitivity<\/td><td>1V\/2A (6A), 1V\/10A (30A)<\/td><\/tr><tr><td>DC Accuracy<\/td><td>\u00b11% \u00b110 mA (6A), \u00b11% \u00b150 mA (30A)<\/td><\/tr><tr><td>Delay Time<\/td><td>&lt;30 ns (both ranges)<\/td><\/tr><tr><td>Max Continuous Current<\/td><td>30A peak, 60A p-p, 21.21A RMS<\/td><\/tr><tr><td>Max Working Voltage (CAT I)<\/td><td>300V (floating \/ to ground)<\/td><\/tr><tr><td>Noise (20 MHz BW, 30A range)<\/td><td>\u22641.4 mA RMS<\/td><\/tr><tr><td>Conductor Diameter<\/td><td>5 mm max<\/td><\/tr><tr><td>Power Supply<\/td><td>DC 5V \/ 3A<\/td><\/tr><tr><td>Interface<\/td><td>BNC (1 M\u03a9 oscilloscope input)<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>How to Reduce Measurement Error in Practice<\/strong><\/h3>\n\n\n\n<p>Even with a high-performance probe, correct usage is key to reduce measurement error. Follow these steps: (1) Always degauss and auto-zero the probe before each measurement, especially after changing range or when the probe has been exposed to large currents. (2) Keep the probe head closed and centered on the conductor to avoid position-dependent errors. (3) Use the lowest range that does not overload, because the Dual range selection current probe gives better signal-to-noise ratio in the lower range. (4) Consider the probe\u2019s delay (&lt;30 ns) when comparing with a voltage probe \u2013 most oscilloscopes have deskew functions to reduce measurement error in power loss calculations. (5) For very low currents (&lt;100 mA), use the 6A range and enable bandwidth limiting (20 MHz) on the oscilloscope to reduce high-frequency noise. This allows you to measure low current easily with high confidence.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Conclusion: A Must-Have Tool for Modern Power Electronics<\/strong><\/h3>\n\n\n\n<p>In summary, capturing high-frequency transient currents in Electric vehicle transportation design and Switching power supply design demands a specialized oscilloscope probe. A standard current probe or current clamp probe for oscilloscope with limited bandwidth will produce low frequency probe distortion and cannot measure high frequency current signal accurately. By contrast, a High Frequency AC DC Current Probe with Dual range selection current probe, Degaussing current probe, Automatic Zero setting current probe, and BNC interface current probe features solves these problems. It enables you to measure surge current during startup, measure low current easily in standby modes, and reduce measurement error to within \u00b11%. Whether you are involved in Experiment of electronic engineering, Semiconductor devices design, Avionics design, Inverter design, Transformer design, Electronic ballast design, Industrial Control design, Consumer Electronics design, Engine driven design, Power electronics experimental design, or Electric drive experimental design, this probe will become an indispensable part of your test bench. And for those looking beyond existing products, we have already developed our own self-designed scope current probe with comparable or superior performance \u2013 ready to support your most demanding applications.<\/p>\n\n\n<style id=\"wpforms-css-vars-4659-block-7e5f2e1e-929d-4841-855e-0a9e65418d4e\">\n\t\t\t\t#wpforms-4659.wpforms-block-7e5f2e1e-929d-4841-855e-0a9e65418d4e {\n\t\t\t\t--wpforms-field-size-input-height: 43px;\n--wpforms-field-size-input-spacing: 15px;\n--wpforms-field-size-font-size: 16px;\n--wpforms-field-size-line-height: 19px;\n--wpforms-field-size-padding-h: 14px;\n--wpforms-field-size-checkbox-size: 16px;\n--wpforms-field-size-sublabel-spacing: 5px;\n--wpforms-field-size-icon-size: 1;\n--wpforms-label-size-font-size: 16px;\n--wpforms-label-size-line-height: 19px;\n--wpforms-label-size-sublabel-font-size: 14px;\n--wpforms-label-size-sublabel-line-height: 17px;\n--wpforms-button-size-font-size: 17px;\n--wpforms-button-size-height: 41px;\n--wpforms-button-size-padding-h: 15px;\n--wpforms-button-size-margin-top: 10px;\n\t\t\t}\n\t\t\t<\/style><div class=\"wpforms-container wpforms-container-full wpforms-block wpforms-block-7e5f2e1e-929d-4841-855e-0a9e65418d4e wpforms-render-modern\" id=\"wpforms-4659\"><form id=\"wpforms-form-4659\" class=\"wpforms-validate wpforms-form wpforms-ajax-form\" data-formid=\"4659\" method=\"post\" enctype=\"multipart\/form-data\" action=\"\/en\/wp-json\/wp\/v2\/posts\/14136\" data-token=\"c2d15c6dbc50d0f6017ae3a12643491a\" data-token-time=\"1781182932\"><noscript class=\"wpforms-error-noscript\">Please enable JavaScript in your browser to complete this form.<\/noscript><div id=\"wpforms-error-noscript\" style=\"display: none;\">Please enable JavaScript in your browser to complete this form.<\/div><div class=\"wpforms-field-container\"><div id=\"wpforms-4659-field_1-container\" class=\"wpforms-field wpforms-field-name\" data-field-id=\"1\"><fieldset><legend class=\"wpforms-field-label\">Name <span class=\"wpforms-required-label\" aria-hidden=\"true\">*<\/span><\/legend><div class=\"wpforms-field-row wpforms-field-large\"><div class=\"wpforms-field-row-block wpforms-first wpforms-one-half\"><input type=\"text\" id=\"wpforms-4659-field_1\" class=\"wpforms-field-name-first wpforms-field-required\" name=\"wpforms[fields][1][first]\" aria-errormessage=\"wpforms-4659-field_1-error\" required><label for=\"wpforms-4659-field_1\" class=\"wpforms-field-sublabel after\">First<\/label><\/div><div class=\"wpforms-field-row-block wpforms-one-half\"><input type=\"text\" id=\"wpforms-4659-field_1-last\" class=\"wpforms-field-name-last wpforms-field-required\" name=\"wpforms[fields][1][last]\" aria-errormessage=\"wpforms-4659-field_1-last-error\" required><label for=\"wpforms-4659-field_1-last\" class=\"wpforms-field-sublabel after\">Last<\/label><\/div><\/div><\/fieldset><\/div>\t\t<div id=\"wpforms-4659-field_5-container\"\n\t\t\tclass=\"wpforms-field wpforms-field-text\"\n\t\t\tdata-field-type=\"text\"\n\t\t\tdata-field-id=\"5\"\n\t\t\t>\n\t\t\t<label class=\"wpforms-field-label\" for=\"wpforms-4659-field_5\" >Company Email Name<\/label>\n\t\t\t<input type=\"text\" id=\"wpforms-4659-field_5\" class=\"wpforms-field-medium\" name=\"wpforms[fields][5]\" >\n\t\t<\/div>\n\t\t<div id=\"wpforms-4659-field_4-container\" class=\"wpforms-field wpforms-field-text\" data-field-id=\"4\"><label class=\"wpforms-field-label\" for=\"wpforms-4659-field_4\">Company <span class=\"wpforms-required-label\" aria-hidden=\"true\">*<\/span><\/label><input type=\"text\" id=\"wpforms-4659-field_4\" class=\"wpforms-field-large wpforms-field-required\" name=\"wpforms[fields][4]\" aria-errormessage=\"wpforms-4659-field_4-error\" required><\/div><div id=\"wpforms-4659-field_2-container\" class=\"wpforms-field wpforms-field-email\" data-field-id=\"2\"><label class=\"wpforms-field-label\" for=\"wpforms-4659-field_2\">Email <span class=\"wpforms-required-label\" aria-hidden=\"true\">*<\/span><\/label><input type=\"email\" id=\"wpforms-4659-field_2\" class=\"wpforms-field-large wpforms-field-required\" name=\"wpforms[fields][2]\" spellcheck=\"false\" aria-errormessage=\"wpforms-4659-field_2-error\" required><\/div><div id=\"wpforms-4659-field_3-container\" class=\"wpforms-field wpforms-field-textarea\" data-field-id=\"3\"><label class=\"wpforms-field-label\" for=\"wpforms-4659-field_3\">Comment or Message<\/label><textarea id=\"wpforms-4659-field_3\" class=\"wpforms-field-medium\" name=\"wpforms[fields][3]\" aria-errormessage=\"wpforms-4659-field_3-error\" ><\/textarea><\/div><div id=\"wpforms-4659-field_6-container\" class=\"wpforms-field wpforms-field-checkbox\" data-field-id=\"6\"><fieldset><legend class=\"wpforms-field-label wpforms-label-hide\" aria-hidden=\"false\">Checkbox <span class=\"wpforms-required-label\" aria-hidden=\"true\">*<\/span><\/legend><ul id=\"wpforms-4659-field_6\" class=\"wpforms-field-required\"><li class=\"choice-1 depth-1 wpforms-selected\"><input type=\"checkbox\" id=\"wpforms-4659-field_6_1\" name=\"wpforms[fields][6][]\" value=\"I agree to the processing of my information for the purpose of creating a quote.\" aria-errormessage=\"wpforms-4659-field_6_1-error\" aria-describedby=\"wpforms-4659-field_6-description\" required  checked='checked'><label class=\"wpforms-field-label-inline\" for=\"wpforms-4659-field_6_1\">I agree to the processing of my information for the purpose of creating a quote.<\/label><\/li><\/ul><div id=\"wpforms-4659-field_6-description\" class=\"wpforms-field-description\">For information see Privacy.<\/div><\/fieldset><\/div><script>\n\t\t\t\t( function() {\n\t\t\t\t\tconst style = document.createElement( 'style' );\n\t\t\t\t\tstyle.appendChild( document.createTextNode( '#wpforms-4659-field_5-container { position: absolute !important; overflow: hidden !important; display: inline !important; height: 1px !important; width: 1px !important; z-index: -1000 !important; padding: 0 !important; } #wpforms-4659-field_5-container input { visibility: hidden; } #wpforms-conversational-form-page #wpforms-4659-field_5-container label { counter-increment: none; }' ) );\n\t\t\t\t\tdocument.head.appendChild( style );\n\t\t\t\t\tdocument.currentScript?.remove();\n\t\t\t\t} )();\n\t\t\t<\/script><\/div><!-- .wpforms-field-container --><div class=\"wpforms-submit-container\" ><input type=\"hidden\" name=\"wpforms[id]\" value=\"4659\"><input type=\"hidden\" name=\"page_title\" value=\"\"><input type=\"hidden\" name=\"page_url\" value=\"https:\/\/tps-elektronik.com\/en\/wp-json\/wp\/v2\/posts\/14136\"><input type=\"hidden\" name=\"url_referer\" value=\"\"><button type=\"submit\" name=\"wpforms[submit]\" id=\"wpforms-submit-4659\" class=\"wpforms-submit\" data-alt-text=\"Sending...\" data-submit-text=\"Submit\" aria-live=\"assertive\" value=\"wpforms-submit\">Submit<\/button><img decoding=\"async\" src=\"https:\/\/tps-elektronik.com\/wp-content\/plugins\/wpforms-lite\/assets\/images\/submit-spin.svg\" class=\"wpforms-submit-spinner\" style=\"display: none;\" width=\"26\" height=\"26\" alt=\"Loading\"><\/div><\/form><\/div>  <!-- .wpforms-container -->","protected":false},"excerpt":{"rendered":"<p>When designing an Electric vehicle transportation design or a Switching power supply design, engineers often face a critical challenge: how to accurately measure fast, high-frequency transient currents. Whether you are dealing with MOSFET switching spikes, inductor inrush currents, or PWM ripple, the right oscilloscope probe is essential. A standard current probe may not provide the\u2026 <a href=\"https:\/\/tps-elektronik.com\/en\/introduction-capturing-high-frequency-transient-current-in-electric-vehicle-and-switching-power-supply-designs\/\">Read More &raquo;<\/a><\/p>\n","protected":false},"author":7,"featured_media":14148,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[53],"tags":[],"class_list":["post-14136","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-production"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Introduction: Capturing High-Frequency Transient Current in Electric Vehicle and Switching Power Supply Designs - TPS<\/title>\n<meta name=\"description\" content=\"Learn how a high frequency AC DC oscilloscope probe captures surge current and solves low frequency distortion in electric vehicle and switching power supply designs. Reduce measurement error with dual range, degaussing, and BNC interface current probe.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/tps-elektronik.com\/en\/introduction-capturing-high-frequency-transient-current-in-electric-vehicle-and-switching-power-supply-designs\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Introduction: Capturing High-Frequency Transient Current in Electric Vehicle and Switching Power Supply Designs - TPS\" \/>\n<meta property=\"og:description\" content=\"Learn how a high frequency AC DC oscilloscope probe captures surge current and solves low frequency distortion in electric vehicle and switching power supply designs. Reduce measurement error with dual range, degaussing, and BNC interface current probe.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/tps-elektronik.com\/en\/introduction-capturing-high-frequency-transient-current-in-electric-vehicle-and-switching-power-supply-designs\/\" \/>\n<meta property=\"og:site_name\" content=\"TPS\" \/>\n<meta property=\"article:published_time\" content=\"2026-06-11T07:30:00+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/06\/Current-proble-20260601-3.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1536\" \/>\n\t<meta property=\"og:image:height\" content=\"1024\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Kael Yuan\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Kael Yuan\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"7 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/introduction-capturing-high-frequency-transient-current-in-electric-vehicle-and-switching-power-supply-designs\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/introduction-capturing-high-frequency-transient-current-in-electric-vehicle-and-switching-power-supply-designs\\\/\"},\"author\":{\"name\":\"Kael Yuan\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/#\\\/schema\\\/person\\\/a09d32c7af89d4e26b0907097a8777c0\"},\"headline\":\"Introduction: Capturing High-Frequency Transient Current in Electric Vehicle and Switching Power Supply Designs\",\"datePublished\":\"2026-06-11T07:30:00+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/introduction-capturing-high-frequency-transient-current-in-electric-vehicle-and-switching-power-supply-designs\\\/\"},\"wordCount\":1460,\"image\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/introduction-capturing-high-frequency-transient-current-in-electric-vehicle-and-switching-power-supply-designs\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/tps-elektronik.com\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/Current-proble-20260601-3.jpg\",\"articleSection\":[\"Product\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/introduction-capturing-high-frequency-transient-current-in-electric-vehicle-and-switching-power-supply-designs\\\/\",\"url\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/introduction-capturing-high-frequency-transient-current-in-electric-vehicle-and-switching-power-supply-designs\\\/\",\"name\":\"Introduction: Capturing High-Frequency Transient Current in Electric Vehicle and Switching Power Supply Designs - TPS\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/introduction-capturing-high-frequency-transient-current-in-electric-vehicle-and-switching-power-supply-designs\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/introduction-capturing-high-frequency-transient-current-in-electric-vehicle-and-switching-power-supply-designs\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/tps-elektronik.com\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/Current-proble-20260601-3.jpg\",\"datePublished\":\"2026-06-11T07:30:00+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/#\\\/schema\\\/person\\\/a09d32c7af89d4e26b0907097a8777c0\"},\"description\":\"Learn how a high frequency AC DC oscilloscope probe captures surge current and solves low frequency distortion in electric vehicle and switching power supply designs. Reduce measurement error with dual range, degaussing, and BNC interface current probe.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/introduction-capturing-high-frequency-transient-current-in-electric-vehicle-and-switching-power-supply-designs\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/introduction-capturing-high-frequency-transient-current-in-electric-vehicle-and-switching-power-supply-designs\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/introduction-capturing-high-frequency-transient-current-in-electric-vehicle-and-switching-power-supply-designs\\\/#primaryimage\",\"url\":\"https:\\\/\\\/tps-elektronik.com\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/Current-proble-20260601-3.jpg\",\"contentUrl\":\"https:\\\/\\\/tps-elektronik.com\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/Current-proble-20260601-3.jpg\",\"width\":1536,\"height\":1024},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/introduction-capturing-high-frequency-transient-current-in-electric-vehicle-and-switching-power-supply-designs\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Startseite\",\"item\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Introduction: Capturing High-Frequency Transient Current in Electric Vehicle and Switching Power Supply Designs\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/\",\"name\":\"TPS\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/#\\\/schema\\\/person\\\/a09d32c7af89d4e26b0907097a8777c0\",\"name\":\"Kael Yuan\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Introduction: Capturing High-Frequency Transient Current in Electric Vehicle and Switching Power Supply Designs - TPS","description":"Learn how a high frequency AC DC oscilloscope probe captures surge current and solves low frequency distortion in electric vehicle and switching power supply designs. Reduce measurement error with dual range, degaussing, and BNC interface current probe.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/tps-elektronik.com\/en\/introduction-capturing-high-frequency-transient-current-in-electric-vehicle-and-switching-power-supply-designs\/","og_locale":"en_US","og_type":"article","og_title":"Introduction: Capturing High-Frequency Transient Current in Electric Vehicle and Switching Power Supply Designs - TPS","og_description":"Learn how a high frequency AC DC oscilloscope probe captures surge current and solves low frequency distortion in electric vehicle and switching power supply designs. Reduce measurement error with dual range, degaussing, and BNC interface current probe.","og_url":"https:\/\/tps-elektronik.com\/en\/introduction-capturing-high-frequency-transient-current-in-electric-vehicle-and-switching-power-supply-designs\/","og_site_name":"TPS","article_published_time":"2026-06-11T07:30:00+00:00","og_image":[{"width":1536,"height":1024,"url":"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/06\/Current-proble-20260601-3.jpg","type":"image\/jpeg"}],"author":"Kael Yuan","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Kael Yuan","Est. reading time":"7 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/tps-elektronik.com\/en\/introduction-capturing-high-frequency-transient-current-in-electric-vehicle-and-switching-power-supply-designs\/#article","isPartOf":{"@id":"https:\/\/tps-elektronik.com\/en\/introduction-capturing-high-frequency-transient-current-in-electric-vehicle-and-switching-power-supply-designs\/"},"author":{"name":"Kael Yuan","@id":"https:\/\/tps-elektronik.com\/en\/#\/schema\/person\/a09d32c7af89d4e26b0907097a8777c0"},"headline":"Introduction: Capturing High-Frequency Transient Current in Electric Vehicle and Switching Power Supply Designs","datePublished":"2026-06-11T07:30:00+00:00","mainEntityOfPage":{"@id":"https:\/\/tps-elektronik.com\/en\/introduction-capturing-high-frequency-transient-current-in-electric-vehicle-and-switching-power-supply-designs\/"},"wordCount":1460,"image":{"@id":"https:\/\/tps-elektronik.com\/en\/introduction-capturing-high-frequency-transient-current-in-electric-vehicle-and-switching-power-supply-designs\/#primaryimage"},"thumbnailUrl":"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/06\/Current-proble-20260601-3.jpg","articleSection":["Product"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/tps-elektronik.com\/en\/introduction-capturing-high-frequency-transient-current-in-electric-vehicle-and-switching-power-supply-designs\/","url":"https:\/\/tps-elektronik.com\/en\/introduction-capturing-high-frequency-transient-current-in-electric-vehicle-and-switching-power-supply-designs\/","name":"Introduction: Capturing High-Frequency Transient Current in Electric Vehicle and Switching Power Supply Designs - TPS","isPartOf":{"@id":"https:\/\/tps-elektronik.com\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/tps-elektronik.com\/en\/introduction-capturing-high-frequency-transient-current-in-electric-vehicle-and-switching-power-supply-designs\/#primaryimage"},"image":{"@id":"https:\/\/tps-elektronik.com\/en\/introduction-capturing-high-frequency-transient-current-in-electric-vehicle-and-switching-power-supply-designs\/#primaryimage"},"thumbnailUrl":"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/06\/Current-proble-20260601-3.jpg","datePublished":"2026-06-11T07:30:00+00:00","author":{"@id":"https:\/\/tps-elektronik.com\/en\/#\/schema\/person\/a09d32c7af89d4e26b0907097a8777c0"},"description":"Learn how a high frequency AC DC oscilloscope probe captures surge current and solves low frequency distortion in electric vehicle and switching power supply designs. Reduce measurement error with dual range, degaussing, and BNC interface current probe.","breadcrumb":{"@id":"https:\/\/tps-elektronik.com\/en\/introduction-capturing-high-frequency-transient-current-in-electric-vehicle-and-switching-power-supply-designs\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/tps-elektronik.com\/en\/introduction-capturing-high-frequency-transient-current-in-electric-vehicle-and-switching-power-supply-designs\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/tps-elektronik.com\/en\/introduction-capturing-high-frequency-transient-current-in-electric-vehicle-and-switching-power-supply-designs\/#primaryimage","url":"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/06\/Current-proble-20260601-3.jpg","contentUrl":"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/06\/Current-proble-20260601-3.jpg","width":1536,"height":1024},{"@type":"BreadcrumbList","@id":"https:\/\/tps-elektronik.com\/en\/introduction-capturing-high-frequency-transient-current-in-electric-vehicle-and-switching-power-supply-designs\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Startseite","item":"https:\/\/tps-elektronik.com\/en\/"},{"@type":"ListItem","position":2,"name":"Introduction: Capturing High-Frequency Transient Current in Electric Vehicle and Switching Power Supply Designs"}]},{"@type":"WebSite","@id":"https:\/\/tps-elektronik.com\/en\/#website","url":"https:\/\/tps-elektronik.com\/en\/","name":"TPS","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/tps-elektronik.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/tps-elektronik.com\/en\/#\/schema\/person\/a09d32c7af89d4e26b0907097a8777c0","name":"Kael Yuan"}]}},"_links":{"self":[{"href":"https:\/\/tps-elektronik.com\/en\/wp-json\/wp\/v2\/posts\/14136","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/tps-elektronik.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/tps-elektronik.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/tps-elektronik.com\/en\/wp-json\/wp\/v2\/users\/7"}],"replies":[{"embeddable":true,"href":"https:\/\/tps-elektronik.com\/en\/wp-json\/wp\/v2\/comments?post=14136"}],"version-history":[{"count":3,"href":"https:\/\/tps-elektronik.com\/en\/wp-json\/wp\/v2\/posts\/14136\/revisions"}],"predecessor-version":[{"id":14206,"href":"https:\/\/tps-elektronik.com\/en\/wp-json\/wp\/v2\/posts\/14136\/revisions\/14206"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/tps-elektronik.com\/en\/wp-json\/wp\/v2\/media\/14148"}],"wp:attachment":[{"href":"https:\/\/tps-elektronik.com\/en\/wp-json\/wp\/v2\/media?parent=14136"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/tps-elektronik.com\/en\/wp-json\/wp\/v2\/categories?post=14136"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/tps-elektronik.com\/en\/wp-json\/wp\/v2\/tags?post=14136"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}