{"id":10462,"date":"2026-04-10T09:00:00","date_gmt":"2026-04-10T07:00:00","guid":{"rendered":"https:\/\/tps-elektronik.com\/?p=10462"},"modified":"2026-05-11T08:21:23","modified_gmt":"2026-05-11T06:21:23","slug":"autoranging-programmable-power-supply-ate","status":"publish","type":"post","link":"https:\/\/tps-elektronik.com\/en\/autoranging-programmable-power-supply-ate\/","title":{"rendered":"What Is an Autoranging Programmable Power Supply and Why Does It Matter for Your Test System?"},"content":{"rendered":"<article class=\"product-blog\" lang=\"en\"><header>\n<p data-start=\"1313\" data-end=\"1522\">For system integrators, panel builders, and electrical engineers, designing an Automated Test Equipment (ATE) system or production-line test rig involves strict constraints related to space, power, and budget.<\/p>\n<p data-start=\"1524\" data-end=\"1832\">Selecting the appropriate power source is therefore an important part of system design. Conventional rectangular power supplies often require engineers to oversize wattage capacity to achieve specific voltage or current peaks. This can increase rack space requirements, thermal load, and overall system cost.<\/p>\n<p data-start=\"1834\" data-end=\"2159\">An autoranging programmable power supply addresses this challenge by automatically adjusting voltage and current to maintain high power availability across a wider operating range. Solutions such as the EA-PS 9080-50 1U are designed to support flexible test environments while simplifying integration into modern ATE systems.<\/p>\n<p data-start=\"2161\" data-end=\"2281\">This article explains how autoranging technology works and why it can be beneficial in test and production applications.<\/p>\n<\/header><nav class=\"toc\" aria-label=\"Table of Contents\">\n<h2 id=\"toc-en\">Table of Contents<\/h2>\n<ol>\n<li><a href=\"#en-what-is-autoranging\">What is Autoranging in a Power Supply?<\/a><\/li>\n<li><a href=\"#en-ea-ps-9080\">The EA-PS 9080-50 1U Overview<\/a><\/li>\n<li><a href=\"#en-electrical-performance\">Electrical Performance and Precision<\/a><\/li>\n<li><a href=\"#en-system-integration\">System Integration and Interfaces<\/a><\/li>\n<li><a href=\"#en-applications\">Typical Applications for ATE and Production<\/a><\/li>\n<li><a href=\"#en-rfq-checklist\">RFQ Checklist for Procurement Teams<\/a><\/li>\n<li><a href=\"#en-faq\">Frequently Asked Questions (FAQ)<\/a><\/li>\n<\/ol>\n<\/nav>\n<section>\n<h1 data-section-id=\"111799y\" data-start=\"2579\" data-end=\"2619\">What Is Autoranging in a Power Supply?<\/h1>\n<p data-start=\"2621\" data-end=\"2777\">In a conventional rectangular power supply, maximum power is typically available only at one operating point: maximum voltage combined with maximum current.<\/p>\n<p data-start=\"2779\" data-end=\"2847\">In practical test environments, however, applications often require:<\/p>\n<ul data-start=\"2849\" data-end=\"2958\">\n<li data-section-id=\"1q2p1o\" data-start=\"2849\" data-end=\"2882\">High voltage with lower current<\/li>\n<li data-section-id=\"1aljooc\" data-start=\"2883\" data-end=\"2916\">High current with lower voltage<\/li>\n<li data-section-id=\"1dkvtlt\" data-start=\"2917\" data-end=\"2958\">Multiple DUT profiles within one system<\/li>\n<\/ul>\n<p data-start=\"2960\" data-end=\"3030\">In these cases, only part of the available power capacity is utilized.<\/p>\n<p data-start=\"3032\" data-end=\"3311\">An autoranging programmable power supply automatically adjusts the available current according to the selected voltage (and vice versa) to maintain the rated output power over a broader operating range. This operating behavior is commonly represented by a hyperbolic power curve.<\/p>\n<p data-start=\"3313\" data-end=\"3445\">As a result, a single autoranging unit may cover operating ranges that would otherwise require multiple conventional power supplies.<\/p>\n<p data-start=\"3447\" data-end=\"3506\">For engineers and system integrators, this can help reduce:<\/p>\n<ul data-start=\"3508\" data-end=\"3640\">\n<li data-section-id=\"1dc0fvf\" data-start=\"3508\" data-end=\"3533\">Rack space requirements<\/li>\n<li data-section-id=\"1v8phd5\" data-start=\"3534\" data-end=\"3553\">System complexity<\/li>\n<li data-section-id=\"hyla52\" data-start=\"3554\" data-end=\"3571\">Heat generation<\/li>\n<li data-section-id=\"1tp8qu0\" data-start=\"3572\" data-end=\"3640\">The number of power supply variants needed in one test environment<\/li>\n<\/ul>\n<p><!-- Image 1 Placeholder --><\/p>\n<figure><img decoding=\"async\" class=\"alignnone size-full wp-image-12999\" src=\"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/05\/1U-Rack-Mount-Programmable-DC-Power-Supply-1-1-1120x576-1.jpg\" alt=\"1U-Rack-Mount-Programmable-DC-Power-Supply\" width=\"1120\" height=\"576\" \/><br \/>\n<figcaption>\n<p data-start=\"3647\" data-end=\"3738\"><em data-start=\"3647\" data-end=\"3738\">A 1U rack-mount power supply can help optimize cabinet space in high-density ATE systems.<\/em><\/p>\n<\/figcaption>\n<\/figure>\n<\/section>\n<section>\n<h2 id=\"en-ea-ps-9080\">The EA-PS 9080-50 1U Overview<\/h2>\n<p data-start=\"3774\" data-end=\"3926\">The EA-PS 9080-50 1U is a microprocessor-controlled programmable DC power supply from the EA-PS 9000 1U series. It is designed for applications such as:<\/p>\n<ul data-start=\"3928\" data-end=\"4024\">\n<li data-section-id=\"bq1bco\" data-start=\"3928\" data-end=\"3948\">R&amp;D and validation<\/li>\n<li data-section-id=\"1vdnoho\" data-start=\"3949\" data-end=\"3969\">Electronic testing<\/li>\n<li data-section-id=\"12qmxv9\" data-start=\"3970\" data-end=\"3993\">Prototype development<\/li>\n<li data-section-id=\"f0jcnf\" data-start=\"3994\" data-end=\"4024\">Automated production testing<\/li>\n<\/ul>\n<p data-start=\"4026\" data-end=\"4044\">The unit provides:<\/p>\n<ul data-start=\"4046\" data-end=\"4126\">\n<li data-section-id=\"ikonsq\" data-start=\"4046\" data-end=\"4074\">Adjustable voltage: 0\u201380 V<\/li>\n<li data-section-id=\"1muuqqz\" data-start=\"4075\" data-end=\"4103\">Adjustable current: 0\u201350 A<\/li>\n<li data-section-id=\"1rkqmbl\" data-start=\"4104\" data-end=\"4126\">Output power: 1500 W<\/li>\n<\/ul>\n<p data-start=\"4128\" data-end=\"4258\">Its compact 1U rack-mount design (19\u201d \u00d7 1U \u00d7 500 mm) supports space-efficient integration into industrial cabinets and test racks.<\/p>\n<p data-start=\"4260\" data-end=\"4416\">For applications requiring different power densities or installation formats, additional <a href=\"https:\/\/www.shop-tps.com\/shop\/category\/programmable-power-2u-programmable-dc-power-187\" target=\"_blank\" rel=\"noopener noreferrer nofollow\">2U<\/a> and <a href=\"https:\/\/www.shop-tps.com\/shop\/category\/programmable-power-3u-programmable-dc-power-188\" target=\"_blank\" rel=\"noopener noreferrer nofollow\">3U<\/a> programmable DC power supply variants are also available.<\/p>\n<p data-start=\"4418\" data-end=\"4443\">The front panel includes:<\/p>\n<ul data-start=\"4445\" data-end=\"4525\">\n<li data-section-id=\"az1glb\" data-start=\"4445\" data-end=\"4462\">Rotary controls<\/li>\n<li data-section-id=\"16qn3zn\" data-start=\"4463\" data-end=\"4476\">Pushbuttons<\/li>\n<li data-section-id=\"1vskjaf\" data-start=\"4477\" data-end=\"4495\">Blue LCD display<\/li>\n<li data-section-id=\"5hrsnq\" data-start=\"4496\" data-end=\"4525\">Status and alarm indicators<\/li>\n<\/ul>\n<p data-start=\"4527\" data-end=\"4662\">For production environments, the integrated panel-lock function helps reduce the risk of unintended parameter changes during operation.<\/p>\n<\/section>\n<section>\n<h2 id=\"en-electrical-performance\">Electrical Performance and Precision<\/h2>\n<p data-start=\"4709\" data-end=\"4817\">In ATE and validation systems, stable output characteristics and repeatability are important considerations.<\/p>\n<p data-start=\"4819\" data-end=\"4890\">The EA-PS 9080-50 1U includes the following electrical characteristics:<\/p>\n<h3 data-section-id=\"d0p10e\" data-start=\"4892\" data-end=\"4934\">Efficiency and Power Factor Correction<\/h3>\n<p data-start=\"4936\" data-end=\"5048\">The unit offers efficiency levels of up to 91% and includes active Power Factor Correction (PFC) with PF = 0.99.<\/p>\n<p data-start=\"5050\" data-end=\"5083\">It supports AC input ranges from:<\/p>\n<ul data-start=\"5085\" data-end=\"5110\">\n<li data-section-id=\"15b1nfy\" data-start=\"5085\" data-end=\"5099\">100\u2013264 V AC<\/li>\n<li data-section-id=\"1vlh2wb\" data-start=\"5100\" data-end=\"5110\">45\u201365 Hz<\/li>\n<\/ul>\n<p data-start=\"5112\" data-end=\"5200\">Please note: output power derates to 1000 W when the AC input voltage is below 150 V AC.<\/p>\n<h3 data-section-id=\"fnrpg\" data-start=\"5202\" data-end=\"5229\">Accuracy and Regulation<\/h3>\n<p data-start=\"5231\" data-end=\"5268\">Specified performance values include:<\/p>\n<ul data-start=\"5270\" data-end=\"5404\">\n<li data-section-id=\"1cqwthb\" data-start=\"5270\" data-end=\"5310\">Voltage accuracy: &lt;0.1% of rated value<\/li>\n<li data-section-id=\"xveae8\" data-start=\"5311\" data-end=\"5344\">Voltage load regulation: &lt;0.05%<\/li>\n<li data-section-id=\"e1cw7n\" data-start=\"5345\" data-end=\"5370\">Current accuracy: &lt;0.2%<\/li>\n<li data-section-id=\"1gn3kga\" data-start=\"5371\" data-end=\"5404\">Current load regulation: &lt;0.15%<\/li>\n<\/ul>\n<h3 data-section-id=\"28eq8e\" data-start=\"5406\" data-end=\"5436\">Low Ripple Characteristics<\/h3>\n<p data-start=\"5438\" data-end=\"5495\">For sensitive electronic applications, the unit provides:<\/p>\n<ul data-start=\"5497\" data-end=\"5571\">\n<li data-section-id=\"sgo2yl\" data-start=\"5497\" data-end=\"5545\">Voltage ripple: 100 mVpp (HF) \/ 5.2 mVrms (LF)<\/li>\n<li data-section-id=\"u05md9\" data-start=\"5546\" data-end=\"5571\">Current ripple: 4 mArms<\/li>\n<\/ul>\n<h3 data-section-id=\"ncmrpw\" data-start=\"5573\" data-end=\"5597\">Protection Functions<\/h3>\n<p data-start=\"5599\" data-end=\"5640\">Integrated protection mechanisms include:<\/p>\n<ul data-start=\"5642\" data-end=\"5767\">\n<li data-section-id=\"t4233\" data-start=\"5642\" data-end=\"5672\">Overvoltage Protection (OVP)<\/li>\n<li data-section-id=\"p39u8h\" data-start=\"5673\" data-end=\"5703\">Overcurrent Protection (OCP)<\/li>\n<li data-section-id=\"1ejjalw\" data-start=\"5704\" data-end=\"5732\">Overpower Protection (OPP)<\/li>\n<li data-section-id=\"y57esj\" data-start=\"5733\" data-end=\"5767\">Overtemperature Protection (OTP)<\/li>\n<\/ul>\n<p data-start=\"5769\" data-end=\"5907\">When threshold values are exceeded, the DC output is automatically disabled to help protect connected devices and the power supply itself.<\/p>\n<p data-start=\"5909\" data-end=\"6040\">Temperature-controlled fans support thermal management while helping reduce unnecessary acoustic noise during lower-load operation.<\/p>\n<p><!-- Image 2 Placeholder --><\/p>\n<figure><img decoding=\"async\" class=\"alignnone size-full wp-image-13004\" src=\"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/05\/Autoranging-Programmable-Power-Supply-Curve-2-1.jpg\" alt=\"Autoranging-Programmable-Power-Supply-Curve\" width=\"1803\" height=\"576\" \/>\n<figcaption>\n<p data-start=\"6047\" data-end=\"6197\"><em data-start=\"6047\" data-end=\"6197\">Autoranging technology allows one power supply to support a broader range of voltage\/current operating combinations within the rated power envelope.<\/em><\/p>\n<\/figcaption>\n<\/figure>\n<\/section>\n<section>\n<h2 id=\"en-system-integration\">System Integration and Interfaces<\/h2>\n<p data-start=\"6241\" data-end=\"6371\">In automated production and test environments, communication between the power supply and the central control system is essential.<\/p>\n<p data-start=\"6373\" data-end=\"6498\">The EA-PS 9080-50 1U includes galvanically isolated interfaces designed for integration into industrial control environments.<\/p>\n<p data-start=\"6500\" data-end=\"6528\">Standard interfaces include:<\/p>\n<ul data-start=\"6530\" data-end=\"6581\">\n<li data-section-id=\"kwzhuh\" data-start=\"6530\" data-end=\"6540\">Ethernet<\/li>\n<li data-section-id=\"1o4vrg\" data-start=\"6541\" data-end=\"6546\">USB<\/li>\n<li data-section-id=\"11vxf4k\" data-start=\"6547\" data-end=\"6581\">Analog interface (15-pole D-Sub)<\/li>\n<\/ul>\n<p data-start=\"6583\" data-end=\"6625\">Supported communication protocols include:<\/p>\n<ul data-start=\"6627\" data-end=\"6646\">\n<li data-section-id=\"1j4cutd\" data-start=\"6627\" data-end=\"6633\">SCPI<\/li>\n<li data-section-id=\"541lnd\" data-start=\"6634\" data-end=\"6646\">ModBus RTU<\/li>\n<\/ul>\n<p data-start=\"6648\" data-end=\"6678\">The analog interface supports:<\/p>\n<ul data-start=\"6680\" data-end=\"6753\">\n<li data-section-id=\"1r95t1h\" data-start=\"6680\" data-end=\"6695\">0\u20135 V signals<\/li>\n<li data-section-id=\"1nd4gvl\" data-start=\"6696\" data-end=\"6712\">0\u201310 V signals<\/li>\n<li data-section-id=\"q1hdmq\" data-start=\"6713\" data-end=\"6753\">Monitoring and remote setpoint control<\/li>\n<\/ul>\n<p data-start=\"6755\" data-end=\"6889\">Optional interface modules may be available for applications requiring additional communication standards, including GPIB integration.<\/p>\n<p data-start=\"6891\" data-end=\"7050\">The unit is also compatible with LabVIEW VIs for custom automation workflows and can be managed via \u201cEA Power Control\u201d software for Windows-based environments.<\/p>\n<p data-start=\"7052\" data-end=\"7092\">Additional integration features include:<\/p>\n<ul data-start=\"7094\" data-end=\"7145\">\n<li data-section-id=\"gozcpz\" data-start=\"7094\" data-end=\"7110\">Remote sensing<\/li>\n<li data-section-id=\"pgc6f5\" data-start=\"7111\" data-end=\"7145\">Parallel operation via Share Bus<\/li>\n<\/ul>\n<p data-start=\"7147\" data-end=\"7268\">Explore our full range of <a href=\"https:\/\/www.shop-tps.com\/shop\/category\/programmable-power-14\" target=\"_blank\" rel=\"noopener noreferrer nofollow\">programmable power supplies<\/a> to identify suitable interface configurations for your application.<\/p>\n<\/section>\n<section>\n<h2 id=\"en-applications\">Typical Applications for ATE and Production<\/h2>\n<p data-start=\"7322\" data-end=\"7424\">The EA-PS 9080-50 1U can be integrated into different stages of product development and manufacturing.<\/p>\n<h2 data-section-id=\"19wmf5q\" data-start=\"7426\" data-end=\"7459\">Automated Test Equipment (ATE)<\/h2>\n<p data-start=\"7461\" data-end=\"7577\">Its compact 1U form factor and SCPI compatibility make it suitable for automated test systems used in areas such as:<\/p>\n<ul data-start=\"7579\" data-end=\"7651\">\n<li data-section-id=\"oiu4yi\" data-start=\"7579\" data-end=\"7603\">Automotive electronics<\/li>\n<li data-section-id=\"16r52o4\" data-start=\"7604\" data-end=\"7627\">Aerospace electronics<\/li>\n<li data-section-id=\"16v6xpx\" data-start=\"7628\" data-end=\"7651\">Semiconductor testing<\/li>\n<\/ul>\n<h2 data-section-id=\"wk98ph\" data-start=\"7653\" data-end=\"7675\">R&amp;D and Prototyping<\/h2>\n<p data-start=\"7677\" data-end=\"7817\">Although designed for rack integration, the front-panel controls and display also support laboratory-based development and validation tasks.<\/p>\n<p data-start=\"7819\" data-end=\"7899\">For dedicated desktop systems, the EA-PSI 9000 DT series may also be considered.<\/p>\n<h2 data-section-id=\"12hr50z\" data-start=\"7901\" data-end=\"7927\">Production-Line Testing<\/h2>\n<p data-start=\"7929\" data-end=\"7946\">Features such as:<\/p>\n<ul data-start=\"7948\" data-end=\"8022\">\n<li data-section-id=\"kdo511\" data-start=\"7948\" data-end=\"7960\">Panel lock<\/li>\n<li data-section-id=\"1nukiod\" data-start=\"7961\" data-end=\"7994\">Integrated protection functions<\/li>\n<li data-section-id=\"11r6oix\" data-start=\"7995\" data-end=\"8022\">High-efficiency operation<\/li>\n<\/ul>\n<p data-start=\"8024\" data-end=\"8095\">support continuous operation in production and validation environments.<\/p>\n<p><!-- Image 3 Placeholder --><\/p>\n<figure><img decoding=\"async\" class=\"alignnone size-full wp-image-13009\" src=\"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/05\/DC-Power-Supply-with-Ethernet-Interfaces-3-1.jpg\" alt=\"DC-Power-Supply-with-Ethernet-Interfaces\" width=\"1803\" height=\"576\" \/>\n<figcaption>\n<p data-start=\"8102\" data-end=\"8219\"><em data-start=\"8102\" data-end=\"8219\">Galvanically isolated analog and digital interfaces support integration into industrial and automated test systems.<\/em><\/p>\n<\/figcaption>\n<\/figure>\n<\/section>\n<section>\n<h2 id=\"en-rfq-checklist\">RFQ Checklist for Procurement Teams<\/h2>\n<p data-start=\"8265\" data-end=\"8426\">When sourcing a programmable DC power supply, engineering and procurement teams should align on key technical and integration requirements before issuing an RFQ.<\/p>\n<h2 data-section-id=\"1bfdq4a\" data-start=\"8428\" data-end=\"8456\">Voltage and Current Range<\/h2>\n<p data-start=\"8458\" data-end=\"8533\">Confirm that the autoranging operating profile covers all DUT requirements.<\/p>\n<h2 data-section-id=\"1saidoe\" data-start=\"8535\" data-end=\"8549\">Form Factor<\/h2>\n<p data-start=\"8551\" data-end=\"8594\">Determine whether the application requires:<\/p>\n<ul data-start=\"8596\" data-end=\"8689\">\n<li data-section-id=\"1jimj3d\" data-start=\"8596\" data-end=\"8617\">1U rack integration<\/li>\n<li data-section-id=\"1l5xjuj\" data-start=\"8618\" data-end=\"8646\">Higher-power 2U\/3U systems<\/li>\n<li data-section-id=\"1yn8mu0\" data-start=\"8647\" data-end=\"8689\">Larger 4U programmable DC power supplies<\/li>\n<\/ul>\n<h2 data-section-id=\"128r7y5\" data-start=\"8691\" data-end=\"8715\">AC Input Requirements<\/h2>\n<p data-start=\"8717\" data-end=\"8765\">Verify compatibility with the available AC grid.<\/p>\n<p data-start=\"8767\" data-end=\"8854\">Please note that the EA-PS 9080-50 output power derates to 1000 W below 150 V AC input.<\/p>\n<h2 data-section-id=\"1pvwy4z\" data-start=\"8856\" data-end=\"8883\">Communication Interfaces<\/h2>\n<p data-start=\"8885\" data-end=\"8921\">Specify required interfaces such as:<\/p>\n<ul data-start=\"8923\" data-end=\"8963\">\n<li data-section-id=\"kwzhuh\" data-start=\"8923\" data-end=\"8933\">Ethernet<\/li>\n<li data-section-id=\"1o4vrg\" data-start=\"8934\" data-end=\"8939\">USB<\/li>\n<li data-section-id=\"h5h1t1\" data-start=\"8940\" data-end=\"8956\">Analog control<\/li>\n<li data-section-id=\"1j43yyc\" data-start=\"8957\" data-end=\"8963\">GPIB<\/li>\n<\/ul>\n<h2 data-section-id=\"zzlvbo\" data-start=\"8965\" data-end=\"8991\">Compliance Requirements<\/h2>\n<p data-start=\"8993\" data-end=\"9060\">Verify compatibility with applicable regional or project standards.<\/p>\n<p data-start=\"9062\" data-end=\"9111\">The EA-PS 9080-50 is specified as compliant with:<\/p>\n<ul data-start=\"9113\" data-end=\"9153\">\n<li data-section-id=\"1u9kyt5\" data-start=\"9113\" data-end=\"9123\">EN 60950<\/li>\n<li data-section-id=\"1u9llir\" data-start=\"9124\" data-end=\"9134\">EN 61326<\/li>\n<li data-section-id=\"1owvlpb\" data-start=\"9135\" data-end=\"9153\">EN 55022 Class B<\/li>\n<\/ul>\n<\/section>\n<section>\n<h2 id=\"en-faq\">Frequently Asked Questions (FAQ)<\/h2>\n<h2 data-section-id=\"yw93qr\" data-start=\"9196\" data-end=\"9260\">1. What is the main advantage of an autoranging power supply?<\/h2>\n<p data-start=\"9262\" data-end=\"9451\">Autoranging technology allows the power supply to maintain rated output power across a wider range of voltage and current combinations compared with conventional rectangular power supplies.<\/p>\n<p data-start=\"9453\" data-end=\"9537\">This may reduce the number of separate power supplies required within a test system.<\/p>\n<h2 data-section-id=\"583grs\" data-start=\"9544\" data-end=\"9604\">2. Can the EA-PS 9080-50 1U be controlled over a network?<\/h2>\n<p data-start=\"9606\" data-end=\"9753\">Yes. The unit includes Ethernet and USB interfaces and supports SCPI and ModBus RTU communication protocols for integration into automated systems.<\/p>\n<h2 data-section-id=\"7m3o87\" data-start=\"9760\" data-end=\"9806\">3. Is the unit suitable for 110 V AC grids?<\/h2>\n<p data-start=\"9808\" data-end=\"9881\">Yes. The power supply supports 100\u2013264 V AC input ranges with active PFC.<\/p>\n<p data-start=\"9883\" data-end=\"9987\">Please note that output power derates from 1500 W to 1000 W when the AC input voltage is below 150 V AC.<\/p>\n<h2 data-section-id=\"1ywtpxu\" data-start=\"9994\" data-end=\"10046\">4. How does the unit help protect sensitive DUTs?<\/h2>\n<p data-start=\"10048\" data-end=\"10107\">The unit includes integrated protection mechanisms such as:<\/p>\n<ul data-start=\"10109\" data-end=\"10132\">\n<li data-section-id=\"1o4an5\" data-start=\"10109\" data-end=\"10114\">OVP<\/li>\n<li data-section-id=\"1o4ac4\" data-start=\"10115\" data-end=\"10120\">OCP<\/li>\n<li data-section-id=\"1o4ap3\" data-start=\"10121\" data-end=\"10126\">OPP<\/li>\n<li data-section-id=\"1o4alf\" data-start=\"10127\" data-end=\"10132\">OTP<\/li>\n<\/ul>\n<p data-start=\"10134\" data-end=\"10213\">If configured thresholds are exceeded, the DC output is automatically disabled.<\/p>\n<h2 data-section-id=\"ikhi3f\" data-start=\"10220\" data-end=\"10261\">5. Can the unit be used on a benchtop?<\/h2>\n<p data-start=\"10263\" data-end=\"10405\">Yes. Although primarily designed for rack integration, the front-panel controls and display also support laboratory and development use cases.<\/p>\n<p data-start=\"10407\" data-end=\"10514\">For dedicated desktop-oriented systems, desktop programmable DC power supply series may also be considered.<\/p>\n<\/section>\n<footer style=\"background: #2d5797; padding: 30px; border-radius: 14px; margin-top: 40px;\">\n<h2 data-section-id=\"uk8qz5\" data-start=\"10521\" data-end=\"10559\"><span style=\"color: #ffffff;\">Ready to Optimize Your Test System?<\/span><\/h2>\n<p style=\"color: #ffffff; font-size: 16px; line-height: 1.6; margin: 0;\">Discover how autoranging programmable DC power supplies can support space-efficient and flexible ATE system design. <a style=\"color: #ffffff; font-weight: 600; text-decoration: underline;\" href=\"https:\/\/www.shop-tps.com\/shop\/category\/programmable-power-14\" target=\"_blank\" rel=\"noopener noreferrer nofollow\">Explore Programmable Power Supplies at <\/a><a href=\"https:\/\/tps-elektronik.com\/en\/\">TPS<\/a><a style=\"color: #ffffff; font-weight: 600; text-decoration: underline;\" href=\"https:\/\/www.shop-tps.com\/shop\/category\/programmable-power-14\" target=\"_blank\" rel=\"noopener noreferrer nofollow\">\u2192<\/a><\/p>\n<\/footer><\/article>\n\n<style id=\"wpforms-css-vars-4659-block-ea140d16-3d12-4b85-ab23-6e4433a22144\">\n\t\t\t\t#wpforms-4659.wpforms-block-ea140d16-3d12-4b85-ab23-6e4433a22144 {\n\t\t\t\t--wpforms-field-size-input-height: 43px;\n--wpforms-field-size-input-spacing: 15px;\n--wpforms-field-size-font-size: 16px;\n--wpforms-field-size-line-height: 19px;\n--wpforms-field-size-padding-h: 14px;\n--wpforms-field-size-checkbox-size: 16px;\n--wpforms-field-size-sublabel-spacing: 5px;\n--wpforms-field-size-icon-size: 1;\n--wpforms-label-size-font-size: 16px;\n--wpforms-label-size-line-height: 19px;\n--wpforms-label-size-sublabel-font-size: 14px;\n--wpforms-label-size-sublabel-line-height: 17px;\n--wpforms-button-size-font-size: 17px;\n--wpforms-button-size-height: 41px;\n--wpforms-button-size-padding-h: 15px;\n--wpforms-button-size-margin-top: 10px;\n\t\t\t}\n\t\t\t<\/style><div class=\"wpforms-container wpforms-container-full wpforms-block wpforms-block-ea140d16-3d12-4b85-ab23-6e4433a22144 wpforms-render-modern\" id=\"wpforms-4659\"><form id=\"wpforms-form-4659\" class=\"wpforms-validate wpforms-form wpforms-ajax-form\" data-formid=\"4659\" method=\"post\" enctype=\"multipart\/form-data\" action=\"\/en\/wp-json\/wp\/v2\/posts\/10462\" data-token=\"1720adb03892233df96390108829d9a8\" data-token-time=\"1779456361\"><noscript class=\"wpforms-error-noscript\">Please enable JavaScript in your browser to complete this form.<\/noscript><div id=\"wpforms-error-noscript\" style=\"display: none;\">Please enable JavaScript in your browser to complete this form.<\/div><div class=\"wpforms-field-container\"><div id=\"wpforms-4659-field_1-container\" class=\"wpforms-field wpforms-field-name\" data-field-id=\"1\"><fieldset><legend class=\"wpforms-field-label\">Name <span class=\"wpforms-required-label\" aria-hidden=\"true\">*<\/span><\/legend><div class=\"wpforms-field-row wpforms-field-large\"><div class=\"wpforms-field-row-block wpforms-first wpforms-one-half\"><input type=\"text\" id=\"wpforms-4659-field_1\" class=\"wpforms-field-name-first wpforms-field-required\" name=\"wpforms[fields][1][first]\" aria-errormessage=\"wpforms-4659-field_1-error\" required><label for=\"wpforms-4659-field_1\" class=\"wpforms-field-sublabel after\">First<\/label><\/div><div class=\"wpforms-field-row-block wpforms-one-half\"><input type=\"text\" id=\"wpforms-4659-field_1-last\" class=\"wpforms-field-name-last wpforms-field-required\" name=\"wpforms[fields][1][last]\" aria-errormessage=\"wpforms-4659-field_1-last-error\" required><label for=\"wpforms-4659-field_1-last\" class=\"wpforms-field-sublabel after\">Last<\/label><\/div><\/div><\/fieldset><\/div><div id=\"wpforms-4659-field_4-container\" class=\"wpforms-field wpforms-field-text\" data-field-id=\"4\"><label class=\"wpforms-field-label\" for=\"wpforms-4659-field_4\">Company <span class=\"wpforms-required-label\" aria-hidden=\"true\">*<\/span><\/label><input type=\"text\" id=\"wpforms-4659-field_4\" class=\"wpforms-field-large wpforms-field-required\" name=\"wpforms[fields][4]\" aria-errormessage=\"wpforms-4659-field_4-error\" required><\/div>\t\t<div id=\"wpforms-4659-field_5-container\"\n\t\t\tclass=\"wpforms-field wpforms-field-text\"\n\t\t\tdata-field-type=\"text\"\n\t\t\tdata-field-id=\"5\"\n\t\t\t>\n\t\t\t<label class=\"wpforms-field-label\" for=\"wpforms-4659-field_5\" >Name Message Checkbox<\/label>\n\t\t\t<input type=\"text\" id=\"wpforms-4659-field_5\" class=\"wpforms-field-medium\" name=\"wpforms[fields][5]\" >\n\t\t<\/div>\n\t\t<div id=\"wpforms-4659-field_2-container\" class=\"wpforms-field wpforms-field-email\" data-field-id=\"2\"><label class=\"wpforms-field-label\" for=\"wpforms-4659-field_2\">Email <span class=\"wpforms-required-label\" aria-hidden=\"true\">*<\/span><\/label><input type=\"email\" id=\"wpforms-4659-field_2\" class=\"wpforms-field-large wpforms-field-required\" name=\"wpforms[fields][2]\" spellcheck=\"false\" aria-errormessage=\"wpforms-4659-field_2-error\" required><\/div><div id=\"wpforms-4659-field_3-container\" class=\"wpforms-field wpforms-field-textarea\" data-field-id=\"3\"><label class=\"wpforms-field-label\" for=\"wpforms-4659-field_3\">Comment or Message<\/label><textarea id=\"wpforms-4659-field_3\" class=\"wpforms-field-medium\" name=\"wpforms[fields][3]\" aria-errormessage=\"wpforms-4659-field_3-error\" ><\/textarea><\/div><div id=\"wpforms-4659-field_6-container\" class=\"wpforms-field wpforms-field-checkbox\" data-field-id=\"6\"><fieldset><legend class=\"wpforms-field-label wpforms-label-hide\" aria-hidden=\"false\">Checkbox <span class=\"wpforms-required-label\" aria-hidden=\"true\">*<\/span><\/legend><ul id=\"wpforms-4659-field_6\" class=\"wpforms-field-required\"><li class=\"choice-1 depth-1 wpforms-selected\"><input type=\"checkbox\" id=\"wpforms-4659-field_6_1\" name=\"wpforms[fields][6][]\" value=\"I agree to the processing of my information for the purpose of creating a quote.\" aria-errormessage=\"wpforms-4659-field_6_1-error\" aria-describedby=\"wpforms-4659-field_6-description\" required  checked='checked'><label class=\"wpforms-field-label-inline\" for=\"wpforms-4659-field_6_1\">I agree to the processing of my information for the purpose of creating a quote.<\/label><\/li><\/ul><div id=\"wpforms-4659-field_6-description\" class=\"wpforms-field-description\">For information see Privacy.<\/div><\/fieldset><\/div><script>\n\t\t\t\t( function() {\n\t\t\t\t\tconst style = document.createElement( 'style' );\n\t\t\t\t\tstyle.appendChild( document.createTextNode( '#wpforms-4659-field_5-container { position: absolute !important; overflow: hidden !important; display: inline !important; height: 1px !important; width: 1px !important; z-index: -1000 !important; padding: 0 !important; } #wpforms-4659-field_5-container input { visibility: hidden; } #wpforms-conversational-form-page #wpforms-4659-field_5-container label { counter-increment: none; }' ) );\n\t\t\t\t\tdocument.head.appendChild( style );\n\t\t\t\t\tdocument.currentScript?.remove();\n\t\t\t\t} )();\n\t\t\t<\/script><\/div><!-- .wpforms-field-container --><div class=\"wpforms-submit-container\" ><input type=\"hidden\" name=\"wpforms[id]\" value=\"4659\"><input type=\"hidden\" name=\"page_title\" value=\"\"><input type=\"hidden\" name=\"page_url\" value=\"https:\/\/tps-elektronik.com\/en\/wp-json\/wp\/v2\/posts\/10462\"><input type=\"hidden\" name=\"url_referer\" value=\"\"><button type=\"submit\" name=\"wpforms[submit]\" id=\"wpforms-submit-4659\" class=\"wpforms-submit\" data-alt-text=\"Sending...\" data-submit-text=\"Submit\" aria-live=\"assertive\" value=\"wpforms-submit\">Submit<\/button><img decoding=\"async\" src=\"https:\/\/tps-elektronik.com\/wp-content\/plugins\/wpforms-lite\/assets\/images\/submit-spin.svg\" class=\"wpforms-submit-spinner\" style=\"display: none;\" width=\"26\" height=\"26\" alt=\"Loading\"><\/div><\/form><\/div>  <!-- .wpforms-container -->","protected":false},"excerpt":{"rendered":"<p>Discover how autoranging programmable power supplies help optimize ATE and production test systems by supporting flexible voltage\/current combinations, reducing rack space requirements, and simplifying system integration.<\/p>\n","protected":false},"author":9,"featured_media":10489,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[53],"tags":[],"class_list":["post-10462","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-production"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.6 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Autoranging Programmable Power Supplies for Modern ATE Systems<\/title>\n<meta name=\"description\" content=\"how autoranging programmable power supplies support efficient ATE and production test system design with flexible voltage\/current operation &amp; compact rack integration.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/tps-elektronik.com\/en\/autoranging-programmable-power-supply-ate\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Autoranging Programmable Power Supplies for Modern ATE Systems\" \/>\n<meta property=\"og:description\" content=\"how autoranging programmable power supplies support efficient ATE and production test system design with flexible voltage\/current operation &amp; compact rack integration.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/tps-elektronik.com\/en\/autoranging-programmable-power-supply-ate\/\" \/>\n<meta property=\"og:site_name\" content=\"TPS\" \/>\n<meta property=\"article:published_time\" content=\"2026-04-10T07:00:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-05-11T06:21:23+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/04\/1U-Rack-Mount-Programmable-DC-Power-Supply-1-1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1803\" \/>\n\t<meta property=\"og:image:height\" content=\"576\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Tang Marcus\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Tang Marcus\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"7 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/autoranging-programmable-power-supply-ate\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/autoranging-programmable-power-supply-ate\\\/\"},\"author\":{\"name\":\"Tang Marcus\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/#\\\/schema\\\/person\\\/2c19fd053095d0c1ae253e8e62427b8c\"},\"headline\":\"What Is an Autoranging Programmable Power Supply and Why Does It Matter for Your Test System?\",\"datePublished\":\"2026-04-10T07:00:00+00:00\",\"dateModified\":\"2026-05-11T06:21:23+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/autoranging-programmable-power-supply-ate\\\/\"},\"wordCount\":1259,\"image\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/autoranging-programmable-power-supply-ate\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/tps-elektronik.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/1U-Rack-Mount-Programmable-DC-Power-Supply-1-1.jpg\",\"articleSection\":[\"Product\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/autoranging-programmable-power-supply-ate\\\/\",\"url\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/autoranging-programmable-power-supply-ate\\\/\",\"name\":\"Autoranging Programmable Power Supplies for Modern ATE Systems\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/autoranging-programmable-power-supply-ate\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/autoranging-programmable-power-supply-ate\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/tps-elektronik.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/1U-Rack-Mount-Programmable-DC-Power-Supply-1-1.jpg\",\"datePublished\":\"2026-04-10T07:00:00+00:00\",\"dateModified\":\"2026-05-11T06:21:23+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/#\\\/schema\\\/person\\\/2c19fd053095d0c1ae253e8e62427b8c\"},\"description\":\"how autoranging programmable power supplies support efficient ATE and production test system design with flexible voltage\\\/current operation & compact rack integration.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/autoranging-programmable-power-supply-ate\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/autoranging-programmable-power-supply-ate\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/autoranging-programmable-power-supply-ate\\\/#primaryimage\",\"url\":\"https:\\\/\\\/tps-elektronik.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/1U-Rack-Mount-Programmable-DC-Power-Supply-1-1.jpg\",\"contentUrl\":\"https:\\\/\\\/tps-elektronik.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/1U-Rack-Mount-Programmable-DC-Power-Supply-1-1.jpg\",\"width\":1803,\"height\":576,\"caption\":\"1U Rack Mount Programmable DC Power Supply 1HE Rack Mount Programmierbares DC Netzteil\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/autoranging-programmable-power-supply-ate\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Startseite\",\"item\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"What Is an Autoranging Programmable Power Supply and Why Does It Matter for Your Test System?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/\",\"name\":\"TPS\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/#\\\/schema\\\/person\\\/2c19fd053095d0c1ae253e8e62427b8c\",\"name\":\"Tang Marcus\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Autoranging Programmable Power Supplies for Modern ATE Systems","description":"how autoranging programmable power supplies support efficient ATE and production test system design with flexible voltage\/current operation & compact rack integration.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/tps-elektronik.com\/en\/autoranging-programmable-power-supply-ate\/","og_locale":"en_US","og_type":"article","og_title":"Autoranging Programmable Power Supplies for Modern ATE Systems","og_description":"how autoranging programmable power supplies support efficient ATE and production test system design with flexible voltage\/current operation & compact rack integration.","og_url":"https:\/\/tps-elektronik.com\/en\/autoranging-programmable-power-supply-ate\/","og_site_name":"TPS","article_published_time":"2026-04-10T07:00:00+00:00","article_modified_time":"2026-05-11T06:21:23+00:00","og_image":[{"width":1803,"height":576,"url":"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/04\/1U-Rack-Mount-Programmable-DC-Power-Supply-1-1.jpg","type":"image\/jpeg"}],"author":"Tang Marcus","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Tang Marcus","Est. reading time":"7 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/tps-elektronik.com\/en\/autoranging-programmable-power-supply-ate\/#article","isPartOf":{"@id":"https:\/\/tps-elektronik.com\/en\/autoranging-programmable-power-supply-ate\/"},"author":{"name":"Tang Marcus","@id":"https:\/\/tps-elektronik.com\/en\/#\/schema\/person\/2c19fd053095d0c1ae253e8e62427b8c"},"headline":"What Is an Autoranging Programmable Power Supply and Why Does It Matter for Your Test System?","datePublished":"2026-04-10T07:00:00+00:00","dateModified":"2026-05-11T06:21:23+00:00","mainEntityOfPage":{"@id":"https:\/\/tps-elektronik.com\/en\/autoranging-programmable-power-supply-ate\/"},"wordCount":1259,"image":{"@id":"https:\/\/tps-elektronik.com\/en\/autoranging-programmable-power-supply-ate\/#primaryimage"},"thumbnailUrl":"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/04\/1U-Rack-Mount-Programmable-DC-Power-Supply-1-1.jpg","articleSection":["Product"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/tps-elektronik.com\/en\/autoranging-programmable-power-supply-ate\/","url":"https:\/\/tps-elektronik.com\/en\/autoranging-programmable-power-supply-ate\/","name":"Autoranging Programmable Power Supplies for Modern ATE Systems","isPartOf":{"@id":"https:\/\/tps-elektronik.com\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/tps-elektronik.com\/en\/autoranging-programmable-power-supply-ate\/#primaryimage"},"image":{"@id":"https:\/\/tps-elektronik.com\/en\/autoranging-programmable-power-supply-ate\/#primaryimage"},"thumbnailUrl":"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/04\/1U-Rack-Mount-Programmable-DC-Power-Supply-1-1.jpg","datePublished":"2026-04-10T07:00:00+00:00","dateModified":"2026-05-11T06:21:23+00:00","author":{"@id":"https:\/\/tps-elektronik.com\/en\/#\/schema\/person\/2c19fd053095d0c1ae253e8e62427b8c"},"description":"how autoranging programmable power supplies support efficient ATE and production test system design with flexible voltage\/current operation & compact rack integration.","breadcrumb":{"@id":"https:\/\/tps-elektronik.com\/en\/autoranging-programmable-power-supply-ate\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/tps-elektronik.com\/en\/autoranging-programmable-power-supply-ate\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/tps-elektronik.com\/en\/autoranging-programmable-power-supply-ate\/#primaryimage","url":"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/04\/1U-Rack-Mount-Programmable-DC-Power-Supply-1-1.jpg","contentUrl":"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/04\/1U-Rack-Mount-Programmable-DC-Power-Supply-1-1.jpg","width":1803,"height":576,"caption":"1U Rack Mount Programmable DC Power Supply 1HE Rack Mount Programmierbares DC Netzteil"},{"@type":"BreadcrumbList","@id":"https:\/\/tps-elektronik.com\/en\/autoranging-programmable-power-supply-ate\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Startseite","item":"https:\/\/tps-elektronik.com\/en\/"},{"@type":"ListItem","position":2,"name":"What Is an Autoranging Programmable Power Supply and Why Does It Matter for Your Test System?"}]},{"@type":"WebSite","@id":"https:\/\/tps-elektronik.com\/en\/#website","url":"https:\/\/tps-elektronik.com\/en\/","name":"TPS","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/tps-elektronik.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/tps-elektronik.com\/en\/#\/schema\/person\/2c19fd053095d0c1ae253e8e62427b8c","name":"Tang Marcus"}]}},"_links":{"self":[{"href":"https:\/\/tps-elektronik.com\/en\/wp-json\/wp\/v2\/posts\/10462","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/tps-elektronik.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/tps-elektronik.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/tps-elektronik.com\/en\/wp-json\/wp\/v2\/users\/9"}],"replies":[{"embeddable":true,"href":"https:\/\/tps-elektronik.com\/en\/wp-json\/wp\/v2\/comments?post=10462"}],"version-history":[{"count":2,"href":"https:\/\/tps-elektronik.com\/en\/wp-json\/wp\/v2\/posts\/10462\/revisions"}],"predecessor-version":[{"id":13123,"href":"https:\/\/tps-elektronik.com\/en\/wp-json\/wp\/v2\/posts\/10462\/revisions\/13123"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/tps-elektronik.com\/en\/wp-json\/wp\/v2\/media\/10489"}],"wp:attachment":[{"href":"https:\/\/tps-elektronik.com\/en\/wp-json\/wp\/v2\/media?parent=10462"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/tps-elektronik.com\/en\/wp-json\/wp\/v2\/categories?post=10462"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/tps-elektronik.com\/en\/wp-json\/wp\/v2\/tags?post=10462"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}