{"id":10462,"date":"2026-04-10T09:00:00","date_gmt":"2026-04-10T07:00:00","guid":{"rendered":"https:\/\/tps-elektronik.com\/?p=10462"},"modified":"2026-04-08T10:59:23","modified_gmt":"2026-04-08T08:59:23","slug":"autoranging-programmable-power-supply-ate","status":"publish","type":"post","link":"https:\/\/tps-elektronik.com\/en\/autoranging-programmable-power-supply-ate\/","title":{"rendered":"What is an autoranging programmable power supply and why does it matter for your test system?"},"content":{"rendered":"<article class=\"product-blog\" lang=\"en\"><header>\n<p>For system integrators, panel builders, and electrical engineers, designing an Automated Test Equipment (ATE) system or a production line test rig involves strict space, power, and budget constraints.<\/p>\n<p>Selecting the right power source is critical. Traditional rectangular power supplies often force engineers to over-specify wattage just to hit a specific voltage or current peak. This leads to wasted rack space, excess heat, and inflated costs.<\/p>\n<p>The solution lies in the <strong>autoranging programmable power supply<\/strong>. Units like the EA-PS 9080-50 1U offer a flexible power stage that automatically adjusts voltage and current to maintain maximum power output across a wider operating range. This article explores why an autoranging <strong>programmable dc power supply<\/strong> is essential for modern test systems and how it streamlines system integration.<\/p>\n<\/header><nav class=\"toc\" aria-label=\"Table of Contents\">\n<h2 id=\"toc-en\">Table of Contents<\/h2>\n<ol>\n<li><a href=\"#en-what-is-autoranging\">What is Autoranging in a Power Supply?<\/a><\/li>\n<li><a href=\"#en-ea-ps-9080\">The EA-PS 9080-50 1U: A High Power Density Supply<\/a><\/li>\n<li><a href=\"#en-electrical-performance\">Electrical Performance &amp; Precision<\/a><\/li>\n<li><a href=\"#en-system-integration\">System Integration: Interfaces &amp; Control<\/a><\/li>\n<li><a href=\"#en-applications\">Key Applications for ATE and Production<\/a><\/li>\n<li><a href=\"#en-rfq-checklist\">RFQ Checklist for Procurement<\/a><\/li>\n<li><a href=\"#en-faq\">Frequently Asked Questions (FAQ)<\/a><\/li>\n<\/ol>\n<\/nav>\n<section>\n<h2 id=\"en-what-is-autoranging\">What is Autoranging in a Power Supply?<\/h2>\n<p>In a conventional (rectangular) power supply, maximum power is only available at one specific operating point\u2014maximum voltage and maximum current. If your test requires high voltage but low current, or high current but low voltage, you are only utilizing a fraction of the unit&#8217;s total power capacity.<\/p>\n<p>An <strong>autoranging programmable power supply<\/strong> changes this dynamic. It features a power stage that automatically adjusts the available current based on the requested voltage (and vice versa) to maintain the maximum rated power (e.g., 1500W) over a wide continuous range. This hyperbolic power curve means a single autoranging unit can replace multiple conventional supplies. Which making it the ultimate <strong>system integration power supply<\/strong>.<\/p>\n<p>For engineers, this translates to significant cost savings and reduced rack space, as one versatile unit can test a diverse portfolio of devices under test (DUTs).<\/p>\n<p><!-- Image 1 Placeholder --><\/p>\n<figure><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-10489\" src=\"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/04\/1U-Rack-Mount-Programmable-DC-Power-Supply-1-1.jpg\" alt=\"1U Rack Mount Programmable DC Power Supply 1HE Rack Mount Programmierbares DC Netzteil\" width=\"1803\" height=\"576\" \/><br \/>\n<figcaption>A 1U rack mount power supply saves critical cabinet space in high-density ATE systems.<\/figcaption>\n<\/figure>\n<\/section>\n<section>\n<h2 id=\"en-ea-ps-9080\">The EA-PS 9080-50 1U: A High Power Density Supply<\/h2>\n<p>The EA-PS 9080-50 1U is a microprocessor-controlled unit from the EA-PS 9000 1U series, engineered specifically for R&amp;D, electronic testing, and prototype validation. As a 1500W model, it delivers an impressive 0-80V adjustable voltage and 0-50A variable current.<\/p>\n<p>Space is a premium in industrial cabinets. This unit is a true <strong>high power density supply<\/strong>, packed into a compact <strong>rack mount power supply<\/strong> format (19\u201cx1Ux500mm). This 1U form factor allows panel builders to stack multiple units or leave room for other critical instrumentation. For setups requiring different form factors, TPS also offers <a href=\"https:\/\/www.shop-tps.com\/shop\/category\/programmable-power-2u-programmable-dc-power-187\" target=\"_blank\" rel=\"noopener noreferrer nofollow\">2U programmable DC power supplies<\/a> and <a href=\"https:\/\/www.shop-tps.com\/shop\/category\/programmable-power-3u-programmable-dc-power-188\" target=\"_blank\" rel=\"noopener noreferrer nofollow\">3U programmable DC power supplies<\/a>.<\/p>\n<p>The front control panel is designed for intuitive operation, featuring rotary knobs, pushbuttons, and a clear blue LCD that displays values, status, and alarms. Crucially for production environments, it includes a panel lock feature to prevent unintentional misuse by operators.<\/p>\n<\/section>\n<section>\n<h2 id=\"en-electrical-performance\">Electrical Performance &amp; Precision<\/h2>\n<p>When acting as an <strong>ATE power supply<\/strong>, precision and stability are non-negotiable. The EA-PS 9080-50 1U excels in electrical performance:<\/p>\n<ul>\n<li><strong>Efficiency &amp; PFC:<\/strong> It achieves up to 91% efficiency, drastically cutting energy loss and thermal dissipation. The active Power Factor Correction (PF=0.99) ensures compatibility with 100&#8230;264V AC grids (45&#8230;65Hz). Note that the unit derates to 1000W at &lt;150V AC input.<\/li>\n<li><strong>Accuracy:<\/strong> Voltage accuracy is &lt;0.1% of the rated value, with load regulation at &lt;0.05%. Current accuracy is &lt;0.2%, with load regulation at &lt;0.15%.<\/li>\n<li><strong>Low Ripple:<\/strong> To ensure stability for sensitive electronics, it boasts a low voltage ripple of 100 mV PP (HF) \/ 5.2 mV RMS (LF), and a current ripple of just 4 mA RMS.<\/li>\n<\/ul>\n<p>Comprehensive safety features, including Overvoltage Protection (OVP), Overcurrent Protection (OCP), Overpower Protection (OPP), and Overtemperature Protection (OTP), automatically shut off the DC output upon detecting anomalies. Temperature-controlled fans ensure optimal cooling without excessive acoustic noise.<\/p>\n<p><!-- Image 2 Placeholder --><\/p>\n<figure><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-10497\" src=\"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/04\/Autoranging-Programmable-Power-Supply-Curve-2-1.jpg\" alt=\"Autoranging Programmable Power Supply Curve Autoranging Programmierbares Netzteil Kurve\" width=\"1803\" height=\"576\" \/><br \/>\n<figcaption>The autoranging capability allows a single power supply to cover a wide range of voltage and current combinations at full power.<\/figcaption>\n<\/figure>\n<\/section>\n<section>\n<h2 id=\"en-system-integration\">System Integration: Interfaces &amp; Control<\/h2>\n<p>A modern <strong>production line power supply<\/strong> must communicate seamlessly with the central test sequencer. The EA-PS 9080-50 1U provides galvanically isolated interfaces to ensure reliable, noise-free control.<\/p>\n<p>It functions as a highly capable <strong>dc power supply with ethernet<\/strong> and USB digital interfaces, supporting industry-standard SCPI and ModBus RTU protocols. For legacy or specialized setups, it also features an analog interface (15-pole D-Sub, 0&#8230;5V\/0&#8230;10V signals for setting and monitoring). While USB and Ethernet are standard, environments requiring a <strong>GPIB programmable power supply<\/strong> can often integrate optional interface modules.<\/p>\n<p>Furthermore, it is fully compatible with LabView VIs for custom applications and includes &#8220;EA Power Control&#8221; software for Windows, enabling multi-unit management. For scaling power, it supports remote sensing and parallel operation via a Share Bus.<\/p>\n<p>Explore our full range of <a href=\"https:\/\/www.shop-tps.com\/shop\/category\/programmable-power-14\" target=\"_blank\" rel=\"noopener noreferrer nofollow\">programmable power supplies<\/a> to find the exact interface options your system requires.<\/p>\n<\/section>\n<section>\n<h2 id=\"en-applications\">Key Applications for ATE and Production<\/h2>\n<p>The versatility of the EA-PS 9080-50 1U makes it suitable for various stages of the product lifecycle:<\/p>\n<ul>\n<li><strong>Automated Test Equipment (ATE):<\/strong> Its 1U size and SCPI compatibility make it the perfect <strong>ATE power supply<\/strong> for testing automotive components, aerospace electronics, and semiconductor devices.<\/li>\n<li><strong>R&amp;D and Prototyping:<\/strong> While rack-mountable, its precise control and clear LCD make it an excellent high-power <strong>benchtop dc power supply<\/strong> for laboratory validation. For dedicated desktop models, consider the <a href=\"https:\/\/tps-elektronik.com\/en\/ea-psi-9000-dt-desktop-programmable-dc-power-supply\/\">EA-PSI 9000 DT series<\/a>.<\/li>\n<li><strong>Production Lines:<\/strong> The panel lock feature, combined with robust OVP\/OCP protections and high efficiency, ensures reliable 24\/7 operation as a <strong>production line power supply<\/strong>.<\/li>\n<\/ul>\n<p><!-- Image 3 Placeholder --><\/p>\n<figure><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-10493\" src=\"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/04\/DC-Power-Supply-with-Ethernet-Interfaces-3-1.jpg\" alt=\"DC Power Supply with Ethernet Interfaces DC Netzteil mit Ethernet Schnittstellen\" width=\"1803\" height=\"576\" \/><br \/>\n<figcaption>Galvanically isolated analog and digital interfaces (USB\/Ethernet) ensure seamless and safe system integration.<\/figcaption>\n<\/figure>\n<\/section>\n<section>\n<h2 id=\"en-rfq-checklist\">RFQ Checklist for Procurement<\/h2>\n<p>When sourcing a <strong>programmable power supply<\/strong> for your facility, procurement teams and engineers should align on the following checklist to ensure a smooth RFQ process:<\/p>\n<ul>\n<li><strong>Voltage &amp; Current Range:<\/strong> Does the autoranging profile cover all your DUT requirements?<\/li>\n<li><strong>Form Factor:<\/strong> Do you need a <a href=\"https:\/\/www.shop-tps.com\/shop\/category\/programmable-power-1u-programmable-dc-power-186\" target=\"_blank\" rel=\"noopener noreferrer nofollow\">1U rack mount<\/a>, or a larger <a href=\"https:\/\/www.shop-tps.com\/shop\/category\/programmable-power-4u-programmable-dc-power-189\" target=\"_blank\" rel=\"noopener noreferrer nofollow\">4U programmable DC power supply<\/a> for higher power?<\/li>\n<li><strong>Grid Compatibility:<\/strong> Verify your AC input. Remember the EA-PS 9080-50 derates to 1000W below 150V AC.<\/li>\n<li><strong>Control Interfaces:<\/strong> Specify if you need Ethernet, USB, Analog, or a specific <strong>GPIB programmable power supply<\/strong> module.<\/li>\n<li><strong>Compliance:<\/strong> Ensure the unit meets your regional standards. The EA-PS 9080-50 meets <a href=\"https:\/\/webstore.iec.ch\/publication\/4304\" target=\"_blank\" rel=\"nofollow noopener\">EN 60950<\/a>, EN 61326, and EN 55022 Class B.<\/li>\n<\/ul>\n<\/section>\n<section>\n<h2 id=\"en-faq\">Frequently Asked Questions (FAQ)<\/h2>\n<p><strong>1. What is the main advantage of an autoranging power supply?<\/strong><br \/>Autoranging allows the power supply to deliver full output power across a wide range of voltage and current combinations, unlike rectangular supplies that only deliver full power at maximum voltage and current. This reduces the need for multiple power supplies.<\/p>\n<p><strong>2. Can the EA-PS 9080-50 1U be controlled via a network?<\/strong><br \/>Yes, it is a <strong>dc power supply with ethernet<\/strong> and USB interfaces, supporting SCPI and ModBus RTU protocols for easy integration into networked ATE systems.<\/p>\n<p><strong>3. Is this unit suitable for 110V AC grids?<\/strong><br \/>Yes, it features active PFC and works with 100&#8230;264V AC grids. However, please note that the output power derates from 1500W to 1000W when the AC input is below 150V.<\/p>\n<p><strong>4. How does the unit protect sensitive Devices Under Test (DUTs)?<\/strong><br \/>It includes comprehensive, galvanically isolated protection features including Overvoltage Protection (OVP), Overcurrent Protection (OCP), Overpower Protection (OPP), and Overtemperature Protection (OTP), which immediately shut off the DC output if thresholds are exceeded.<\/p>\n<p><strong>5. Can I use this as a benchtop unit?<\/strong><br \/>While optimized as a <strong>rack mount power supply<\/strong>, its clear LCD, rotary knobs, and precise manual control make it perfectly viable for benchtop R&amp;D use. For dedicated desktop designs, explore our <a href=\"https:\/\/www.shop-tps.com\/shop\/category\/programmable-power-desktop-programmable-dc-power-192\" target=\"_blank\" rel=\"noopener noreferrer nofollow\">desktop programmable DC power supplies<\/a>.<\/p>\n<\/section>\n<footer style=\"background: #2d5797; padding: 30px; border-radius: 14px; margin-top: 40px;\">\n<p style=\"color: #ffffff; font-size: 16px; line-height: 1.6; margin: 0;\"><strong>Ready to upgrade your test system?<\/strong> Discover how our high power density, autoranging solutions can optimize your ATE rack space and budget. <a style=\"color: #ffffff; font-weight: 600; text-decoration: underline;\" href=\"https:\/\/www.shop-tps.com\/shop\/category\/programmable-power-14\" target=\"_blank\" rel=\"noopener noreferrer nofollow\">Explore Programmable Power Supplies at TPS \u2192<\/a><\/p>\n<\/footer><\/article>\n\n<style id=\"wpforms-css-vars-4659-block-ea140d16-3d12-4b85-ab23-6e4433a22144\">\n\t\t\t\t#wpforms-4659.wpforms-block-ea140d16-3d12-4b85-ab23-6e4433a22144 {\n\t\t\t\t--wpforms-field-size-input-height: 43px;\n--wpforms-field-size-input-spacing: 15px;\n--wpforms-field-size-font-size: 16px;\n--wpforms-field-size-line-height: 19px;\n--wpforms-field-size-padding-h: 14px;\n--wpforms-field-size-checkbox-size: 16px;\n--wpforms-field-size-sublabel-spacing: 5px;\n--wpforms-field-size-icon-size: 1;\n--wpforms-label-size-font-size: 16px;\n--wpforms-label-size-line-height: 19px;\n--wpforms-label-size-sublabel-font-size: 14px;\n--wpforms-label-size-sublabel-line-height: 17px;\n--wpforms-button-size-font-size: 17px;\n--wpforms-button-size-height: 41px;\n--wpforms-button-size-padding-h: 15px;\n--wpforms-button-size-margin-top: 10px;\n\t\t\t}\n\t\t\t<\/style><div class=\"wpforms-container wpforms-container-full wpforms-block wpforms-block-ea140d16-3d12-4b85-ab23-6e4433a22144 wpforms-render-modern\" id=\"wpforms-4659\"><form id=\"wpforms-form-4659\" class=\"wpforms-validate wpforms-form wpforms-ajax-form\" data-formid=\"4659\" method=\"post\" enctype=\"multipart\/form-data\" action=\"\/en\/wp-json\/wp\/v2\/posts\/10462\" data-token=\"c3b8c2316c74e61ba3598ec1cd68130f\" data-token-time=\"1775826833\"><noscript class=\"wpforms-error-noscript\">Please enable JavaScript in your browser to complete this form.<\/noscript><div id=\"wpforms-error-noscript\" style=\"display: none;\">Please enable JavaScript in your browser to complete this form.<\/div><div class=\"wpforms-field-container\"><div id=\"wpforms-4659-field_1-container\" class=\"wpforms-field wpforms-field-name\" data-field-id=\"1\"><fieldset><legend class=\"wpforms-field-label\">Name <span class=\"wpforms-required-label\" aria-hidden=\"true\">*<\/span><\/legend><div class=\"wpforms-field-row wpforms-field-large\"><div class=\"wpforms-field-row-block wpforms-first wpforms-one-half\"><input type=\"text\" id=\"wpforms-4659-field_1\" class=\"wpforms-field-name-first wpforms-field-required\" name=\"wpforms[fields][1][first]\" aria-errormessage=\"wpforms-4659-field_1-error\" required><label for=\"wpforms-4659-field_1\" class=\"wpforms-field-sublabel after\">First<\/label><\/div><div class=\"wpforms-field-row-block wpforms-one-half\"><input type=\"text\" id=\"wpforms-4659-field_1-last\" class=\"wpforms-field-name-last wpforms-field-required\" name=\"wpforms[fields][1][last]\" aria-errormessage=\"wpforms-4659-field_1-last-error\" required><label for=\"wpforms-4659-field_1-last\" class=\"wpforms-field-sublabel after\">Last<\/label><\/div><\/div><\/fieldset><\/div><div id=\"wpforms-4659-field_4-container\" class=\"wpforms-field wpforms-field-text\" data-field-id=\"4\"><label class=\"wpforms-field-label\" for=\"wpforms-4659-field_4\">Company <span class=\"wpforms-required-label\" aria-hidden=\"true\">*<\/span><\/label><input type=\"text\" id=\"wpforms-4659-field_4\" class=\"wpforms-field-large wpforms-field-required\" name=\"wpforms[fields][4]\" aria-errormessage=\"wpforms-4659-field_4-error\" required><\/div><div id=\"wpforms-4659-field_2-container\" class=\"wpforms-field wpforms-field-email\" data-field-id=\"2\"><label class=\"wpforms-field-label\" for=\"wpforms-4659-field_2\">Email <span class=\"wpforms-required-label\" aria-hidden=\"true\">*<\/span><\/label><input type=\"email\" id=\"wpforms-4659-field_2\" class=\"wpforms-field-large wpforms-field-required\" name=\"wpforms[fields][2]\" spellcheck=\"false\" aria-errormessage=\"wpforms-4659-field_2-error\" required><\/div>\t\t<div id=\"wpforms-4659-field_5-container\"\n\t\t\tclass=\"wpforms-field wpforms-field-text\"\n\t\t\tdata-field-type=\"text\"\n\t\t\tdata-field-id=\"5\"\n\t\t\t>\n\t\t\t<label class=\"wpforms-field-label\" for=\"wpforms-4659-field_5\" >Company Name or<\/label>\n\t\t\t<input type=\"text\" id=\"wpforms-4659-field_5\" class=\"wpforms-field-medium\" name=\"wpforms[fields][5]\" >\n\t\t<\/div>\n\t\t<div id=\"wpforms-4659-field_3-container\" class=\"wpforms-field wpforms-field-textarea\" data-field-id=\"3\"><label class=\"wpforms-field-label\" for=\"wpforms-4659-field_3\">Comment or Message<\/label><textarea id=\"wpforms-4659-field_3\" class=\"wpforms-field-medium\" name=\"wpforms[fields][3]\" aria-errormessage=\"wpforms-4659-field_3-error\" ><\/textarea><\/div><div id=\"wpforms-4659-field_6-container\" class=\"wpforms-field wpforms-field-checkbox\" data-field-id=\"6\"><fieldset><legend class=\"wpforms-field-label wpforms-label-hide\" aria-hidden=\"false\">Checkbox <span class=\"wpforms-required-label\" aria-hidden=\"true\">*<\/span><\/legend><ul id=\"wpforms-4659-field_6\" class=\"wpforms-field-required\"><li class=\"choice-1 depth-1 wpforms-selected\"><input type=\"checkbox\" id=\"wpforms-4659-field_6_1\" name=\"wpforms[fields][6][]\" value=\"I agree to the processing of my information for the purpose of creating a quote.\" aria-errormessage=\"wpforms-4659-field_6_1-error\" aria-describedby=\"wpforms-4659-field_6-description\" required  checked='checked'><label class=\"wpforms-field-label-inline\" for=\"wpforms-4659-field_6_1\">I agree to the processing of my information for the purpose of creating a quote.<\/label><\/li><\/ul><div id=\"wpforms-4659-field_6-description\" class=\"wpforms-field-description\">For information see Privacy.<\/div><\/fieldset><\/div><script>\n\t\t\t\t( function() {\n\t\t\t\t\tconst style = document.createElement( 'style' );\n\t\t\t\t\tstyle.appendChild( document.createTextNode( '#wpforms-4659-field_5-container { position: absolute !important; overflow: hidden !important; display: inline !important; height: 1px !important; width: 1px !important; z-index: -1000 !important; padding: 0 !important; } #wpforms-4659-field_5-container input { visibility: hidden; } #wpforms-conversational-form-page #wpforms-4659-field_5-container label { counter-increment: none; }' ) );\n\t\t\t\t\tdocument.head.appendChild( style );\n\t\t\t\t\tdocument.currentScript?.remove();\n\t\t\t\t} )();\n\t\t\t<\/script><\/div><!-- .wpforms-field-container --><div class=\"wpforms-submit-container\" ><input type=\"hidden\" name=\"wpforms[id]\" value=\"4659\"><input type=\"hidden\" name=\"page_title\" value=\"\"><input type=\"hidden\" name=\"page_url\" value=\"https:\/\/tps-elektronik.com\/en\/wp-json\/wp\/v2\/posts\/10462\"><input type=\"hidden\" name=\"url_referer\" value=\"\"><button type=\"submit\" name=\"wpforms[submit]\" id=\"wpforms-submit-4659\" class=\"wpforms-submit\" data-alt-text=\"Sending...\" data-submit-text=\"Submit\" aria-live=\"assertive\" value=\"wpforms-submit\">Submit<\/button><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/tps-elektronik.com\/wp-content\/plugins\/wpforms-lite\/assets\/images\/submit-spin.svg\" class=\"wpforms-submit-spinner\" style=\"display: none;\" width=\"26\" height=\"26\" alt=\"Loading\"><\/div><\/form><\/div>  <!-- .wpforms-container -->","protected":false},"excerpt":{"rendered":"<p>For system integrators, panel builders, and electrical engineers, designing an Automated Test Equipment (ATE) system or a production line test rig involves strict space, power, and budget constraints. Selecting the right power source is critical. Traditional rectangular power supplies often force engineers to over-specify wattage just to hit a specific voltage or current peak. This\u2026 <a href=\"https:\/\/tps-elektronik.com\/en\/autoranging-programmable-power-supply-ate\/\">Read More &raquo;<\/a><\/p>\n","protected":false},"author":9,"featured_media":10489,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[53],"tags":[],"class_list":["post-10462","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-production"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>What is an autoranging programmable power supply and why does it matter for your test system? - TPS<\/title>\n<meta name=\"description\" content=\"Optimize your test system with an autoranging programmable power supply. Explore our 1U rack mount solutions for industrial ATE.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/tps-elektronik.com\/en\/autoranging-programmable-power-supply-ate\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"What is an autoranging programmable power supply and why does it matter for your test system? - TPS\" \/>\n<meta property=\"og:description\" content=\"Optimize your test system with an autoranging programmable power supply. Explore our 1U rack mount solutions for industrial ATE.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/tps-elektronik.com\/en\/autoranging-programmable-power-supply-ate\/\" \/>\n<meta property=\"og:site_name\" content=\"TPS\" \/>\n<meta property=\"article:published_time\" content=\"2026-04-10T07:00:00+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/04\/1U-Rack-Mount-Programmable-DC-Power-Supply-1-1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1803\" \/>\n\t<meta property=\"og:image:height\" content=\"576\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Tang Marcus\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Tang Marcus\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"7 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/autoranging-programmable-power-supply-ate\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/autoranging-programmable-power-supply-ate\\\/\"},\"author\":{\"name\":\"Tang Marcus\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/#\\\/schema\\\/person\\\/2c19fd053095d0c1ae253e8e62427b8c\"},\"headline\":\"What is an autoranging programmable power supply and why does it matter for your test system?\",\"datePublished\":\"2026-04-10T07:00:00+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/autoranging-programmable-power-supply-ate\\\/\"},\"wordCount\":1292,\"image\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/autoranging-programmable-power-supply-ate\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/tps-elektronik.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/1U-Rack-Mount-Programmable-DC-Power-Supply-1-1.jpg\",\"articleSection\":[\"Product\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/autoranging-programmable-power-supply-ate\\\/\",\"url\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/autoranging-programmable-power-supply-ate\\\/\",\"name\":\"What is an autoranging programmable power supply and why does it matter for your test system? - TPS\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/autoranging-programmable-power-supply-ate\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/autoranging-programmable-power-supply-ate\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/tps-elektronik.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/1U-Rack-Mount-Programmable-DC-Power-Supply-1-1.jpg\",\"datePublished\":\"2026-04-10T07:00:00+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/#\\\/schema\\\/person\\\/2c19fd053095d0c1ae253e8e62427b8c\"},\"description\":\"Optimize your test system with an autoranging programmable power supply. Explore our 1U rack mount solutions for industrial ATE.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/autoranging-programmable-power-supply-ate\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/autoranging-programmable-power-supply-ate\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/autoranging-programmable-power-supply-ate\\\/#primaryimage\",\"url\":\"https:\\\/\\\/tps-elektronik.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/1U-Rack-Mount-Programmable-DC-Power-Supply-1-1.jpg\",\"contentUrl\":\"https:\\\/\\\/tps-elektronik.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/1U-Rack-Mount-Programmable-DC-Power-Supply-1-1.jpg\",\"width\":1803,\"height\":576,\"caption\":\"1U Rack Mount Programmable DC Power Supply 1HE Rack Mount Programmierbares DC Netzteil\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/autoranging-programmable-power-supply-ate\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Startseite\",\"item\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"What is an autoranging programmable power supply and why does it matter for your test system?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/\",\"name\":\"TPS\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/#\\\/schema\\\/person\\\/2c19fd053095d0c1ae253e8e62427b8c\",\"name\":\"Tang Marcus\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"What is an autoranging programmable power supply and why does it matter for your test system? - TPS","description":"Optimize your test system with an autoranging programmable power supply. Explore our 1U rack mount solutions for industrial ATE.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/tps-elektronik.com\/en\/autoranging-programmable-power-supply-ate\/","og_locale":"en_US","og_type":"article","og_title":"What is an autoranging programmable power supply and why does it matter for your test system? - TPS","og_description":"Optimize your test system with an autoranging programmable power supply. Explore our 1U rack mount solutions for industrial ATE.","og_url":"https:\/\/tps-elektronik.com\/en\/autoranging-programmable-power-supply-ate\/","og_site_name":"TPS","article_published_time":"2026-04-10T07:00:00+00:00","og_image":[{"width":1803,"height":576,"url":"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/04\/1U-Rack-Mount-Programmable-DC-Power-Supply-1-1.jpg","type":"image\/jpeg"}],"author":"Tang Marcus","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Tang Marcus","Est. reading time":"7 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/tps-elektronik.com\/en\/autoranging-programmable-power-supply-ate\/#article","isPartOf":{"@id":"https:\/\/tps-elektronik.com\/en\/autoranging-programmable-power-supply-ate\/"},"author":{"name":"Tang Marcus","@id":"https:\/\/tps-elektronik.com\/en\/#\/schema\/person\/2c19fd053095d0c1ae253e8e62427b8c"},"headline":"What is an autoranging programmable power supply and why does it matter for your test system?","datePublished":"2026-04-10T07:00:00+00:00","mainEntityOfPage":{"@id":"https:\/\/tps-elektronik.com\/en\/autoranging-programmable-power-supply-ate\/"},"wordCount":1292,"image":{"@id":"https:\/\/tps-elektronik.com\/en\/autoranging-programmable-power-supply-ate\/#primaryimage"},"thumbnailUrl":"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/04\/1U-Rack-Mount-Programmable-DC-Power-Supply-1-1.jpg","articleSection":["Product"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/tps-elektronik.com\/en\/autoranging-programmable-power-supply-ate\/","url":"https:\/\/tps-elektronik.com\/en\/autoranging-programmable-power-supply-ate\/","name":"What is an autoranging programmable power supply and why does it matter for your test system? - TPS","isPartOf":{"@id":"https:\/\/tps-elektronik.com\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/tps-elektronik.com\/en\/autoranging-programmable-power-supply-ate\/#primaryimage"},"image":{"@id":"https:\/\/tps-elektronik.com\/en\/autoranging-programmable-power-supply-ate\/#primaryimage"},"thumbnailUrl":"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/04\/1U-Rack-Mount-Programmable-DC-Power-Supply-1-1.jpg","datePublished":"2026-04-10T07:00:00+00:00","author":{"@id":"https:\/\/tps-elektronik.com\/en\/#\/schema\/person\/2c19fd053095d0c1ae253e8e62427b8c"},"description":"Optimize your test system with an autoranging programmable power supply. Explore our 1U rack mount solutions for industrial ATE.","breadcrumb":{"@id":"https:\/\/tps-elektronik.com\/en\/autoranging-programmable-power-supply-ate\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/tps-elektronik.com\/en\/autoranging-programmable-power-supply-ate\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/tps-elektronik.com\/en\/autoranging-programmable-power-supply-ate\/#primaryimage","url":"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/04\/1U-Rack-Mount-Programmable-DC-Power-Supply-1-1.jpg","contentUrl":"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/04\/1U-Rack-Mount-Programmable-DC-Power-Supply-1-1.jpg","width":1803,"height":576,"caption":"1U Rack Mount Programmable DC Power Supply 1HE Rack Mount Programmierbares DC Netzteil"},{"@type":"BreadcrumbList","@id":"https:\/\/tps-elektronik.com\/en\/autoranging-programmable-power-supply-ate\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Startseite","item":"https:\/\/tps-elektronik.com\/en\/"},{"@type":"ListItem","position":2,"name":"What is an autoranging programmable power supply and why does it matter for your test system?"}]},{"@type":"WebSite","@id":"https:\/\/tps-elektronik.com\/en\/#website","url":"https:\/\/tps-elektronik.com\/en\/","name":"TPS","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/tps-elektronik.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/tps-elektronik.com\/en\/#\/schema\/person\/2c19fd053095d0c1ae253e8e62427b8c","name":"Tang Marcus"}]}},"_links":{"self":[{"href":"https:\/\/tps-elektronik.com\/en\/wp-json\/wp\/v2\/posts\/10462","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/tps-elektronik.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/tps-elektronik.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/tps-elektronik.com\/en\/wp-json\/wp\/v2\/users\/9"}],"replies":[{"embeddable":true,"href":"https:\/\/tps-elektronik.com\/en\/wp-json\/wp\/v2\/comments?post=10462"}],"version-history":[{"count":2,"href":"https:\/\/tps-elektronik.com\/en\/wp-json\/wp\/v2\/posts\/10462\/revisions"}],"predecessor-version":[{"id":10501,"href":"https:\/\/tps-elektronik.com\/en\/wp-json\/wp\/v2\/posts\/10462\/revisions\/10501"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/tps-elektronik.com\/en\/wp-json\/wp\/v2\/media\/10489"}],"wp:attachment":[{"href":"https:\/\/tps-elektronik.com\/en\/wp-json\/wp\/v2\/media?parent=10462"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/tps-elektronik.com\/en\/wp-json\/wp\/v2\/categories?post=10462"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/tps-elektronik.com\/en\/wp-json\/wp\/v2\/tags?post=10462"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}