{"id":10178,"date":"2026-04-01T09:55:36","date_gmt":"2026-04-01T07:55:36","guid":{"rendered":"https:\/\/tps-elektronik.com\/?p=10178"},"modified":"2026-05-06T13:57:46","modified_gmt":"2026-05-06T11:57:46","slug":"single-phase-pole-mounted-transformer-10-333kva","status":"publish","type":"post","link":"https:\/\/tps-elektronik.com\/en\/single-phase-pole-mounted-transformer-10-333kva\/","title":{"rendered":"Single-Phase Pole-Mounted Transformer (10\u2013333 kVA) \u2013 ANSI Oil-Immersed Design"},"content":{"rendered":"<article class=\"product-blog\" lang=\"en\"><header><\/header>\n<section>\n<p data-start=\"1035\" data-end=\"1361\">For utility providers, system integrators, and electrical engineering procurement teams, the reliability of overhead power distribution is a key consideration. Selecting a suitable transformer requires evaluating environmental resistance, electrical performance, safety features, and compliance with applicable grid standards.<\/p>\n<p data-start=\"1363\" data-end=\"1685\">The <a href=\"https:\/\/www.shop-tps.com\/shop\/pvl1081-single-phase-pole-mounted-transformer-33951?category=198#attr=\" target=\"_blank\" rel=\"noopener noreferrer nofollow\">single-phase pole-mounted transformer<\/a> from TPS Elektronik is designed in accordance with ANSI\/IEEE standards for overhead distribution systems. With a fully sealed tank and oil-immersed cooling, it supports capacity ratings from 10 kVA to 333 kVA, making it suitable for a range of utility and commercial applications.<\/p>\n<p data-start=\"1687\" data-end=\"1947\">Primary voltages can be configured up to 34.5 kV, with secondary voltages down to 120 V. The design combines copper windings with standard protection features such as lightning arresters and pressure relief valves, supporting operation in outdoor environments.<\/p>\n<h2 data-section-id=\"xzbqu\" data-start=\"1954\" data-end=\"2003\">1. Design Concept: Sealed Tank and Oil Cooling<\/h2>\n<p data-start=\"2005\" data-end=\"2234\">The transformer uses a fully sealed tank design to isolate internal components from ambient air. This helps limit the ingress of moisture, dust, and contaminants, which can affect insulating oil and internal insulation over time.<\/p>\n<p data-start=\"2236\" data-end=\"2501\">As an oil-immersed transformer, it uses insulating oil for both electrical insulation and heat dissipation. The oil transfers heat from the core and windings to the tank surface, where it is released to the surrounding environment under normal operating conditions.<\/p>\n<p data-start=\"2503\" data-end=\"2649\">For applications requiring alternative installation types (e.g., ground-mounted systems), other transformer configurations may also be considered.<\/p>\n<p><!-- Image 1 Insertion --><\/p>\n<figure><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-10194\" src=\"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/03\/Single-Phase-Pole-Mounted-Transformer-Utility-1.jpg\" alt=\"Single Phase Pole Mounted Transformer installed on a utility pole for overhead distribution.\n\" width=\"1344\" height=\"796\" \/><\/figure>\n<\/section>\n<section>\n<h2 data-section-id=\"1nv3bsi\" data-start=\"2656\" data-end=\"2713\">2. Electrical Specifications and Configuration Options<\/h2>\n<p data-start=\"2715\" data-end=\"2792\">The transformer can be configured to match a wide range of grid requirements:<\/p>\n<ul data-start=\"2794\" data-end=\"2952\">\n<li data-section-id=\"j7qwcp\" data-start=\"2794\" data-end=\"2835\"><strong data-start=\"2796\" data-end=\"2815\">Rated capacity:<\/strong> 10 kVA to 333 kVA<\/li>\n<li data-section-id=\"9axveo\" data-start=\"2836\" data-end=\"2895\"><strong data-start=\"2838\" data-end=\"2863\">Primary (HV) voltage:<\/strong> typically 7,200 V to 34,500 V<\/li>\n<li data-section-id=\"1o13xls\" data-start=\"2896\" data-end=\"2952\"><strong data-start=\"2898\" data-end=\"2925\">Secondary (LV) voltage:<\/strong> typically 120 V to 600 V<\/li>\n<\/ul>\n<p data-start=\"2954\" data-end=\"3189\">Copper windings are used as a standard option, supporting efficient current conduction and mechanical stability. The magnetic core is based on silicon steel laminations, commonly used in distribution transformers to reduce core losses.<\/p>\n<p data-start=\"3191\" data-end=\"3299\">Efficiency and loss values depend on the selected rating and configuration. Typical characteristics include:<\/p>\n<ul data-start=\"3301\" data-end=\"3413\">\n<li data-section-id=\"ad1f61\" data-start=\"3301\" data-end=\"3349\"><strong data-start=\"3303\" data-end=\"3322\">No-load losses:<\/strong> vary depending on rating<\/li>\n<li data-section-id=\"945khq\" data-start=\"3350\" data-end=\"3413\"><strong data-start=\"3352\" data-end=\"3368\">Load losses:<\/strong> increase with capacity and load conditions<\/li>\n<\/ul>\n<p data-start=\"3415\" data-end=\"3515\">For applications requiring electrical isolation, dedicated isolation transformers may be considered.<\/p>\n<h2 data-section-id=\"1q0sj63\" data-start=\"3522\" data-end=\"3558\">3. Safety and Protection Features<\/h2>\n<p data-start=\"3560\" data-end=\"3654\">The transformer can be equipped with standard protection components to support safe operation:<\/p>\n<ul data-start=\"3656\" data-end=\"3933\">\n<li data-section-id=\"1g2q3f8\" data-start=\"3656\" data-end=\"3753\"><strong data-start=\"3658\" data-end=\"3693\">Lightning arresters (optional):<\/strong> help limit overvoltage from lightning or switching events<\/li>\n<li data-section-id=\"lpy9g5\" data-start=\"3754\" data-end=\"3845\"><strong data-start=\"3756\" data-end=\"3782\">Pressure relief valve:<\/strong> releases internal pressure in the event of a fault condition<\/li>\n<li data-section-id=\"1gofwum\" data-start=\"3846\" data-end=\"3933\"><strong data-start=\"3848\" data-end=\"3874\">Sealed cover assembly:<\/strong> supports environmental protection of internal components<\/li>\n<\/ul>\n<p data-start=\"3935\" data-end=\"4031\">These features are commonly used in overhead distribution systems to enhance operational safety.<\/p>\n<h2 id=\"en-electrical-specs\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-12983\" src=\"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/05\/Oil-Immersed-Transformer-Copper-Winding-Arrester-2.jpg\" alt=\"Oil-Immersed-Transformer-Copper-Winding-Arrester\" width=\"1180\" height=\"896\" \/><\/h2>\n<\/section>\n<section>\n<h2 data-section-id=\"1cs4m6f\" data-start=\"4038\" data-end=\"4069\">4. Installation and Handling<\/h2>\n<p data-start=\"4071\" data-end=\"4167\">The design includes features intended to support installation and handling by utility personnel:<\/p>\n<ul data-start=\"4169\" data-end=\"4498\">\n<li data-section-id=\"1uyuddt\" data-start=\"4169\" data-end=\"4242\"><strong data-start=\"4171\" data-end=\"4188\">Lifting lugs:<\/strong> positioned for balanced lifting during installation<\/li>\n<li data-section-id=\"evzg0y\" data-start=\"4243\" data-end=\"4333\"><strong data-start=\"4245\" data-end=\"4268\">HV and LV bushings:<\/strong> provide connection points for incoming and outgoing conductors<\/li>\n<li data-section-id=\"1unp3mu\" data-start=\"4334\" data-end=\"4418\"><strong data-start=\"4336\" data-end=\"4361\">Grounding connection:<\/strong> supports integration into the system grounding concept<\/li>\n<li data-section-id=\"1kpzgcr\" data-start=\"4419\" data-end=\"4498\"><strong data-start=\"4421\" data-end=\"4435\">Nameplate:<\/strong> displays key technical data for identification and operation<\/li>\n<\/ul>\n<p data-start=\"4500\" data-end=\"4577\">Actual installation procedures depend on local standards and site conditions.<\/p>\n<h2 data-section-id=\"16qoowd\" data-start=\"4584\" data-end=\"4610\">5. Typical Applications<\/h2>\n<p data-start=\"4612\" data-end=\"4718\">Pole-mounted transformers are commonly used in last-mile power distribution. Typical applications include:<\/p>\n<ul data-start=\"4720\" data-end=\"4978\">\n<li data-section-id=\"1ukhfqq\" data-start=\"4720\" data-end=\"4805\"><strong data-start=\"4722\" data-end=\"4754\">Urban distribution networks:<\/strong> supplying residential and light commercial loads<\/li>\n<li data-section-id=\"dhidi0\" data-start=\"4806\" data-end=\"4898\"><strong data-start=\"4808\" data-end=\"4834\">Rural electrification:<\/strong> supporting overhead line infrastructure over longer distances<\/li>\n<li data-section-id=\"jptl4g\" data-start=\"4899\" data-end=\"4978\"><strong data-start=\"4901\" data-end=\"4928\">Temporary power supply:<\/strong> e.g., construction sites or event installations<\/li>\n<\/ul>\n<p data-start=\"4980\" data-end=\"5142\">The transformer is designed in line with ANSI\/IEEE requirements for overhead-type distribution transformers, supporting compatibility with North American systems<\/p>\n<\/section>\n<section>\n<p><!-- Image 3 Insertion --><\/p>\n<figure><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-10186\" src=\"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/03\/Overhead-Distribution-Transformer-Commercial-Application-3.jpg\" alt=\"10kVA to 333kVA Transformer providing stable single phase power to a commercial construction site.\n\" width=\"1344\" height=\"796\" \/><\/figure>\n<\/section>\n<section><\/section>\n<section>\n<h2 data-section-id=\"16ypmt5\" data-start=\"5149\" data-end=\"5184\">6. RFQ Checklist for Procurement<\/h2>\n<p data-start=\"5186\" data-end=\"5271\">To facilitate the quotation process, the following information is typically required:<\/p>\n<ul data-start=\"5273\" data-end=\"5562\">\n<li data-section-id=\"16tb7ev\" data-start=\"5273\" data-end=\"5301\"><strong data-start=\"5275\" data-end=\"5299\">Rated capacity (kVA)<\/strong><\/li>\n<li data-section-id=\"1yxik90\" data-start=\"5302\" data-end=\"5340\"><strong data-start=\"5304\" data-end=\"5338\">Primary and secondary voltages<\/strong><\/li>\n<li data-section-id=\"1y5l15t\" data-start=\"5341\" data-end=\"5395\"><strong data-start=\"5343\" data-end=\"5393\">Efficiency or loss requirements (if specified)<\/strong><\/li>\n<li data-section-id=\"1jco5ub\" data-start=\"5396\" data-end=\"5442\"><strong data-start=\"5398\" data-end=\"5440\">Winding material (copper or aluminium)<\/strong><\/li>\n<li data-section-id=\"1nce3hn\" data-start=\"5443\" data-end=\"5507\"><strong data-start=\"5445\" data-end=\"5505\">Required accessories (e.g., arresters, bushings, valves)<\/strong><\/li>\n<li data-section-id=\"118hc9q\" data-start=\"5508\" data-end=\"5562\"><strong data-start=\"5510\" data-end=\"5560\">Applicable standards or utility specifications<\/strong><\/li>\n<\/ul>\n<p data-start=\"5564\" data-end=\"5643\">Providing complete data can help streamline technical evaluation and quotation.<\/p>\n<h2 data-section-id=\"11pg4fl\" data-start=\"5650\" data-end=\"5688\">7. Frequently Asked Questions (FAQ)<\/h2>\n<p data-start=\"5690\" data-end=\"5887\"><strong data-start=\"5690\" data-end=\"5755\">Q1: What is the benefit of a fully sealed transformer design?<\/strong><br data-start=\"5755\" data-end=\"5758\" \/>A sealed design helps limit contamination of the insulating oil and internal components, which can support long-term performance.<\/p>\n<p data-start=\"5889\" data-end=\"6084\"><strong data-start=\"5889\" data-end=\"5935\">Q2: Why are copper windings commonly used?<\/strong><br data-start=\"5935\" data-end=\"5938\" \/>Copper offers high electrical conductivity and mechanical strength, which can contribute to reduced losses and durability under electrical stress.<\/p>\n<p data-start=\"6086\" data-end=\"6252\"><strong data-start=\"6086\" data-end=\"6139\">Q3: What is the function of a lightning arrester?<\/strong><br data-start=\"6139\" data-end=\"6142\" \/>A lightning arrester helps divert transient overvoltages to ground, reducing stress on transformer insulation.<\/p>\n<p data-start=\"6254\" data-end=\"6446\"><strong data-start=\"6254\" data-end=\"6325\">Q4: Can the transformer be configured for different voltage levels?<\/strong><br data-start=\"6325\" data-end=\"6328\" \/>Yes, both primary and secondary voltages can be adapted within the specified ranges to match application requirements.<\/p>\n<p data-start=\"6448\" data-end=\"6680\"><strong data-start=\"6448\" data-end=\"6504\">Q5: Does the transformer follow ANSI\/IEEE standards?<\/strong><br data-start=\"6504\" data-end=\"6507\" \/>The design is based on relevant ANSI\/IEEE standards for overhead distribution transformers. Final compliance depends on the specified configuration and project requirements.<\/p>\n<\/section>\n<footer style=\"background: #2d5797; padding: 30px; border-radius: 14px; margin-top: 40px;\">\n<p style=\"color: #ffffff; font-size: 16px; line-height: 1.6; margin: 0;\"><strong>Ready to upgrade your overhead distribution network?<\/strong> For project-specific configurations or technical clarification, contact the TPS Elektronik team to discuss your application requirements. <a style=\"color: #ffffff; font-weight: 600; text-decoration: underline;\" href=\"https:\/\/www.shop-tps.com\/shop\/category\/power-distribution-voltage-control-transformers-198\" target=\"_blank\" rel=\"noopener noreferrer nofollow\">Request a Quote \/ View Power Solutions \u2192<\/a><\/p>\n<\/footer><\/article>\n\n<style id=\"wpforms-css-vars-4659-block-6fd052d9-295c-414e-be9f-7fd8b95f25ba\">\n\t\t\t\t#wpforms-4659.wpforms-block-6fd052d9-295c-414e-be9f-7fd8b95f25ba {\n\t\t\t\t--wpforms-field-size-input-height: 43px;\n--wpforms-field-size-input-spacing: 15px;\n--wpforms-field-size-font-size: 16px;\n--wpforms-field-size-line-height: 19px;\n--wpforms-field-size-padding-h: 14px;\n--wpforms-field-size-checkbox-size: 16px;\n--wpforms-field-size-sublabel-spacing: 5px;\n--wpforms-field-size-icon-size: 1;\n--wpforms-label-size-font-size: 16px;\n--wpforms-label-size-line-height: 19px;\n--wpforms-label-size-sublabel-font-size: 14px;\n--wpforms-label-size-sublabel-line-height: 17px;\n--wpforms-button-size-font-size: 17px;\n--wpforms-button-size-height: 41px;\n--wpforms-button-size-padding-h: 15px;\n--wpforms-button-size-margin-top: 10px;\n\t\t\t}\n\t\t\t<\/style><div class=\"wpforms-container wpforms-container-full wpforms-block wpforms-block-6fd052d9-295c-414e-be9f-7fd8b95f25ba wpforms-render-modern\" id=\"wpforms-4659\"><form id=\"wpforms-form-4659\" class=\"wpforms-validate wpforms-form wpforms-ajax-form\" data-formid=\"4659\" method=\"post\" enctype=\"multipart\/form-data\" action=\"\/en\/wp-json\/wp\/v2\/posts\/10178\" data-token=\"876ea4898e6acde728ffe51ed4cae11c\" data-token-time=\"1778549579\"><noscript class=\"wpforms-error-noscript\">Please enable JavaScript in your browser to complete this form.<\/noscript><div id=\"wpforms-error-noscript\" style=\"display: none;\">Please enable JavaScript in your browser to complete this form.<\/div><div class=\"wpforms-field-container\"><div id=\"wpforms-4659-field_1-container\" class=\"wpforms-field wpforms-field-name\" data-field-id=\"1\"><fieldset><legend class=\"wpforms-field-label\">Name <span class=\"wpforms-required-label\" aria-hidden=\"true\">*<\/span><\/legend><div class=\"wpforms-field-row wpforms-field-large\"><div class=\"wpforms-field-row-block wpforms-first wpforms-one-half\"><input type=\"text\" id=\"wpforms-4659-field_1\" class=\"wpforms-field-name-first wpforms-field-required\" name=\"wpforms[fields][1][first]\" aria-errormessage=\"wpforms-4659-field_1-error\" required><label for=\"wpforms-4659-field_1\" class=\"wpforms-field-sublabel after\">First<\/label><\/div><div class=\"wpforms-field-row-block wpforms-one-half\"><input type=\"text\" id=\"wpforms-4659-field_1-last\" class=\"wpforms-field-name-last wpforms-field-required\" name=\"wpforms[fields][1][last]\" aria-errormessage=\"wpforms-4659-field_1-last-error\" required><label for=\"wpforms-4659-field_1-last\" class=\"wpforms-field-sublabel after\">Last<\/label><\/div><\/div><\/fieldset><\/div><div id=\"wpforms-4659-field_4-container\" class=\"wpforms-field wpforms-field-text\" data-field-id=\"4\"><label class=\"wpforms-field-label\" for=\"wpforms-4659-field_4\">Company <span class=\"wpforms-required-label\" aria-hidden=\"true\">*<\/span><\/label><input type=\"text\" id=\"wpforms-4659-field_4\" class=\"wpforms-field-large wpforms-field-required\" name=\"wpforms[fields][4]\" aria-errormessage=\"wpforms-4659-field_4-error\" required><\/div><div id=\"wpforms-4659-field_2-container\" class=\"wpforms-field wpforms-field-email\" data-field-id=\"2\"><label class=\"wpforms-field-label\" for=\"wpforms-4659-field_2\">Email <span class=\"wpforms-required-label\" aria-hidden=\"true\">*<\/span><\/label><input type=\"email\" id=\"wpforms-4659-field_2\" class=\"wpforms-field-large wpforms-field-required\" name=\"wpforms[fields][2]\" spellcheck=\"false\" aria-errormessage=\"wpforms-4659-field_2-error\" required><\/div>\t\t<div id=\"wpforms-4659-field_5-container\"\n\t\t\tclass=\"wpforms-field wpforms-field-text\"\n\t\t\tdata-field-type=\"text\"\n\t\t\tdata-field-id=\"5\"\n\t\t\t>\n\t\t\t<label class=\"wpforms-field-label\" for=\"wpforms-4659-field_5\" >or Email Company<\/label>\n\t\t\t<input type=\"text\" id=\"wpforms-4659-field_5\" class=\"wpforms-field-medium\" name=\"wpforms[fields][5]\" >\n\t\t<\/div>\n\t\t<div id=\"wpforms-4659-field_3-container\" class=\"wpforms-field wpforms-field-textarea\" data-field-id=\"3\"><label class=\"wpforms-field-label\" for=\"wpforms-4659-field_3\">Comment or Message<\/label><textarea id=\"wpforms-4659-field_3\" class=\"wpforms-field-medium\" name=\"wpforms[fields][3]\" aria-errormessage=\"wpforms-4659-field_3-error\" ><\/textarea><\/div><div id=\"wpforms-4659-field_6-container\" class=\"wpforms-field wpforms-field-checkbox\" data-field-id=\"6\"><fieldset><legend class=\"wpforms-field-label wpforms-label-hide\" aria-hidden=\"false\">Checkbox <span class=\"wpforms-required-label\" aria-hidden=\"true\">*<\/span><\/legend><ul id=\"wpforms-4659-field_6\" class=\"wpforms-field-required\"><li class=\"choice-1 depth-1 wpforms-selected\"><input type=\"checkbox\" id=\"wpforms-4659-field_6_1\" name=\"wpforms[fields][6][]\" value=\"I agree to the processing of my information for the purpose of creating a quote.\" aria-errormessage=\"wpforms-4659-field_6_1-error\" aria-describedby=\"wpforms-4659-field_6-description\" required  checked='checked'><label class=\"wpforms-field-label-inline\" for=\"wpforms-4659-field_6_1\">I agree to the processing of my information for the purpose of creating a quote.<\/label><\/li><\/ul><div id=\"wpforms-4659-field_6-description\" class=\"wpforms-field-description\">For information see Privacy.<\/div><\/fieldset><\/div><script>\n\t\t\t\t( function() {\n\t\t\t\t\tconst style = document.createElement( 'style' );\n\t\t\t\t\tstyle.appendChild( document.createTextNode( '#wpforms-4659-field_5-container { position: absolute !important; overflow: hidden !important; display: inline !important; height: 1px !important; width: 1px !important; z-index: -1000 !important; padding: 0 !important; } #wpforms-4659-field_5-container input { visibility: hidden; } #wpforms-conversational-form-page #wpforms-4659-field_5-container label { counter-increment: none; }' ) );\n\t\t\t\t\tdocument.head.appendChild( style );\n\t\t\t\t\tdocument.currentScript?.remove();\n\t\t\t\t} )();\n\t\t\t<\/script><\/div><!-- .wpforms-field-container --><div class=\"wpforms-submit-container\" ><input type=\"hidden\" name=\"wpforms[id]\" value=\"4659\"><input type=\"hidden\" name=\"page_title\" value=\"\"><input type=\"hidden\" name=\"page_url\" value=\"https:\/\/tps-elektronik.com\/en\/wp-json\/wp\/v2\/posts\/10178\"><input type=\"hidden\" name=\"url_referer\" value=\"\"><button type=\"submit\" name=\"wpforms[submit]\" id=\"wpforms-submit-4659\" class=\"wpforms-submit\" data-alt-text=\"Sending...\" data-submit-text=\"Submit\" aria-live=\"assertive\" value=\"wpforms-submit\">Submit<\/button><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/tps-elektronik.com\/wp-content\/plugins\/wpforms-lite\/assets\/images\/submit-spin.svg\" class=\"wpforms-submit-spinner\" style=\"display: none;\" width=\"26\" height=\"26\" alt=\"Loading\"><\/div><\/form><\/div>  <!-- .wpforms-container -->","protected":false},"excerpt":{"rendered":"<p>Single-phase pole-mounted transformer (10\u2013333 kVA) designed for overhead distribution. Oil-immersed, ANSI-based design with configurable voltage options for utility and commercial use.<\/p>\n","protected":false},"author":9,"featured_media":10194,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[53],"tags":[],"class_list":["post-10178","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-production"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.5 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Single-Phase Pole-Mounted Transformer (10\u2013333 kVA) | ANSI Oil-Immersed<\/title>\n<meta name=\"description\" content=\"ANSI single-phase pole-mounted transformer (10\u2013333 kVA) for overhead distribution. Oil-immersed design, configurable voltages, suitable for utility and commercial applications.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/tps-elektronik.com\/en\/single-phase-pole-mounted-transformer-10-333kva\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Single-Phase Pole-Mounted Transformer (10\u2013333 kVA) | ANSI Oil-Immersed\" \/>\n<meta property=\"og:description\" content=\"ANSI single-phase pole-mounted transformer (10\u2013333 kVA) for overhead distribution. Oil-immersed design, configurable voltages, suitable for utility and commercial applications.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/tps-elektronik.com\/en\/single-phase-pole-mounted-transformer-10-333kva\/\" \/>\n<meta property=\"og:site_name\" content=\"TPS\" \/>\n<meta property=\"article:published_time\" content=\"2026-04-01T07:55:36+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-05-06T11:57:46+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/03\/Single-Phase-Pole-Mounted-Transformer-Utility-1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1344\" \/>\n\t<meta property=\"og:image:height\" content=\"796\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Tang Marcus\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Tang Marcus\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/single-phase-pole-mounted-transformer-10-333kva\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/single-phase-pole-mounted-transformer-10-333kva\\\/\"},\"author\":{\"name\":\"Tang Marcus\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/#\\\/schema\\\/person\\\/2c19fd053095d0c1ae253e8e62427b8c\"},\"headline\":\"Single-Phase Pole-Mounted Transformer (10\u2013333 kVA) \u2013 ANSI Oil-Immersed Design\",\"datePublished\":\"2026-04-01T07:55:36+00:00\",\"dateModified\":\"2026-05-06T11:57:46+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/single-phase-pole-mounted-transformer-10-333kva\\\/\"},\"wordCount\":748,\"image\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/single-phase-pole-mounted-transformer-10-333kva\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/tps-elektronik.com\\\/wp-content\\\/uploads\\\/2026\\\/03\\\/Single-Phase-Pole-Mounted-Transformer-Utility-1.jpg\",\"articleSection\":[\"Product\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/single-phase-pole-mounted-transformer-10-333kva\\\/\",\"url\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/single-phase-pole-mounted-transformer-10-333kva\\\/\",\"name\":\"Single-Phase Pole-Mounted Transformer (10\u2013333 kVA) | ANSI Oil-Immersed\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/single-phase-pole-mounted-transformer-10-333kva\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/single-phase-pole-mounted-transformer-10-333kva\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/tps-elektronik.com\\\/wp-content\\\/uploads\\\/2026\\\/03\\\/Single-Phase-Pole-Mounted-Transformer-Utility-1.jpg\",\"datePublished\":\"2026-04-01T07:55:36+00:00\",\"dateModified\":\"2026-05-06T11:57:46+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/#\\\/schema\\\/person\\\/2c19fd053095d0c1ae253e8e62427b8c\"},\"description\":\"ANSI single-phase pole-mounted transformer (10\u2013333 kVA) for overhead distribution. Oil-immersed design, configurable voltages, suitable for utility and commercial applications.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/single-phase-pole-mounted-transformer-10-333kva\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/single-phase-pole-mounted-transformer-10-333kva\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/single-phase-pole-mounted-transformer-10-333kva\\\/#primaryimage\",\"url\":\"https:\\\/\\\/tps-elektronik.com\\\/wp-content\\\/uploads\\\/2026\\\/03\\\/Single-Phase-Pole-Mounted-Transformer-Utility-1.jpg\",\"contentUrl\":\"https:\\\/\\\/tps-elektronik.com\\\/wp-content\\\/uploads\\\/2026\\\/03\\\/Single-Phase-Pole-Mounted-Transformer-Utility-1.jpg\",\"width\":1344,\"height\":796,\"caption\":\"Single Phase Pole Mounted Transformer installed on a utility pole for overhead distribution.\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/single-phase-pole-mounted-transformer-10-333kva\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Startseite\",\"item\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Single-Phase Pole-Mounted Transformer (10\u2013333 kVA) \u2013 ANSI Oil-Immersed Design\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/\",\"name\":\"TPS\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/en\\\/#\\\/schema\\\/person\\\/2c19fd053095d0c1ae253e8e62427b8c\",\"name\":\"Tang Marcus\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Single-Phase Pole-Mounted Transformer (10\u2013333 kVA) | ANSI Oil-Immersed","description":"ANSI single-phase pole-mounted transformer (10\u2013333 kVA) for overhead distribution. Oil-immersed design, configurable voltages, suitable for utility and commercial applications.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/tps-elektronik.com\/en\/single-phase-pole-mounted-transformer-10-333kva\/","og_locale":"en_US","og_type":"article","og_title":"Single-Phase Pole-Mounted Transformer (10\u2013333 kVA) | ANSI Oil-Immersed","og_description":"ANSI single-phase pole-mounted transformer (10\u2013333 kVA) for overhead distribution. Oil-immersed design, configurable voltages, suitable for utility and commercial applications.","og_url":"https:\/\/tps-elektronik.com\/en\/single-phase-pole-mounted-transformer-10-333kva\/","og_site_name":"TPS","article_published_time":"2026-04-01T07:55:36+00:00","article_modified_time":"2026-05-06T11:57:46+00:00","og_image":[{"width":1344,"height":796,"url":"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/03\/Single-Phase-Pole-Mounted-Transformer-Utility-1.jpg","type":"image\/jpeg"}],"author":"Tang Marcus","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Tang Marcus","Est. reading time":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/tps-elektronik.com\/en\/single-phase-pole-mounted-transformer-10-333kva\/#article","isPartOf":{"@id":"https:\/\/tps-elektronik.com\/en\/single-phase-pole-mounted-transformer-10-333kva\/"},"author":{"name":"Tang Marcus","@id":"https:\/\/tps-elektronik.com\/en\/#\/schema\/person\/2c19fd053095d0c1ae253e8e62427b8c"},"headline":"Single-Phase Pole-Mounted Transformer (10\u2013333 kVA) \u2013 ANSI Oil-Immersed Design","datePublished":"2026-04-01T07:55:36+00:00","dateModified":"2026-05-06T11:57:46+00:00","mainEntityOfPage":{"@id":"https:\/\/tps-elektronik.com\/en\/single-phase-pole-mounted-transformer-10-333kva\/"},"wordCount":748,"image":{"@id":"https:\/\/tps-elektronik.com\/en\/single-phase-pole-mounted-transformer-10-333kva\/#primaryimage"},"thumbnailUrl":"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/03\/Single-Phase-Pole-Mounted-Transformer-Utility-1.jpg","articleSection":["Product"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/tps-elektronik.com\/en\/single-phase-pole-mounted-transformer-10-333kva\/","url":"https:\/\/tps-elektronik.com\/en\/single-phase-pole-mounted-transformer-10-333kva\/","name":"Single-Phase Pole-Mounted Transformer (10\u2013333 kVA) | ANSI Oil-Immersed","isPartOf":{"@id":"https:\/\/tps-elektronik.com\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/tps-elektronik.com\/en\/single-phase-pole-mounted-transformer-10-333kva\/#primaryimage"},"image":{"@id":"https:\/\/tps-elektronik.com\/en\/single-phase-pole-mounted-transformer-10-333kva\/#primaryimage"},"thumbnailUrl":"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/03\/Single-Phase-Pole-Mounted-Transformer-Utility-1.jpg","datePublished":"2026-04-01T07:55:36+00:00","dateModified":"2026-05-06T11:57:46+00:00","author":{"@id":"https:\/\/tps-elektronik.com\/en\/#\/schema\/person\/2c19fd053095d0c1ae253e8e62427b8c"},"description":"ANSI single-phase pole-mounted transformer (10\u2013333 kVA) for overhead distribution. Oil-immersed design, configurable voltages, suitable for utility and commercial applications.","breadcrumb":{"@id":"https:\/\/tps-elektronik.com\/en\/single-phase-pole-mounted-transformer-10-333kva\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/tps-elektronik.com\/en\/single-phase-pole-mounted-transformer-10-333kva\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/tps-elektronik.com\/en\/single-phase-pole-mounted-transformer-10-333kva\/#primaryimage","url":"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/03\/Single-Phase-Pole-Mounted-Transformer-Utility-1.jpg","contentUrl":"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/03\/Single-Phase-Pole-Mounted-Transformer-Utility-1.jpg","width":1344,"height":796,"caption":"Single Phase Pole Mounted Transformer installed on a utility pole for overhead distribution."},{"@type":"BreadcrumbList","@id":"https:\/\/tps-elektronik.com\/en\/single-phase-pole-mounted-transformer-10-333kva\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Startseite","item":"https:\/\/tps-elektronik.com\/en\/"},{"@type":"ListItem","position":2,"name":"Single-Phase Pole-Mounted Transformer (10\u2013333 kVA) \u2013 ANSI Oil-Immersed Design"}]},{"@type":"WebSite","@id":"https:\/\/tps-elektronik.com\/en\/#website","url":"https:\/\/tps-elektronik.com\/en\/","name":"TPS","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/tps-elektronik.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/tps-elektronik.com\/en\/#\/schema\/person\/2c19fd053095d0c1ae253e8e62427b8c","name":"Tang Marcus"}]}},"_links":{"self":[{"href":"https:\/\/tps-elektronik.com\/en\/wp-json\/wp\/v2\/posts\/10178","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/tps-elektronik.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/tps-elektronik.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/tps-elektronik.com\/en\/wp-json\/wp\/v2\/users\/9"}],"replies":[{"embeddable":true,"href":"https:\/\/tps-elektronik.com\/en\/wp-json\/wp\/v2\/comments?post=10178"}],"version-history":[{"count":3,"href":"https:\/\/tps-elektronik.com\/en\/wp-json\/wp\/v2\/posts\/10178\/revisions"}],"predecessor-version":[{"id":12986,"href":"https:\/\/tps-elektronik.com\/en\/wp-json\/wp\/v2\/posts\/10178\/revisions\/12986"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/tps-elektronik.com\/en\/wp-json\/wp\/v2\/media\/10194"}],"wp:attachment":[{"href":"https:\/\/tps-elektronik.com\/en\/wp-json\/wp\/v2\/media?parent=10178"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/tps-elektronik.com\/en\/wp-json\/wp\/v2\/categories?post=10178"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/tps-elektronik.com\/en\/wp-json\/wp\/v2\/tags?post=10178"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}