{"id":19181,"date":"2026-11-09T09:00:00","date_gmt":"2026-11-09T08:00:00","guid":{"rendered":"https:\/\/tps-elektronik.com\/?p=19181"},"modified":"2026-10-26T09:37:06","modified_gmt":"2026-10-26T08:37:06","slug":"how-to-pass-emc-surge-%c2%b14kv-and-esd-%c2%b115kv-requirements-in-servo-drive-pcba-with-tps-industrial-control-pcba-services","status":"publish","type":"post","link":"https:\/\/tps-elektronik.com\/ar\/how-to-pass-emc-surge-%c2%b14kv-and-esd-%c2%b115kv-requirements-in-servo-drive-pcba-with-tps-industrial-control-pcba-services\/","title":{"rendered":"Wie lassen sich die EMV-Anforderungen f\u00fcr Sto\u00dfspannungen (Surge) von \u00b14 kV sowie f\u00fcr elektrostatische Entladungen (ESD) von \u00b115 kV bei Leiterplatten f\u00fcr Servoantriebe mithilfe der Dienstleistungen von TPS f\u00fcr industrielle Steuerungs-Leiterplatten erf\u00fcllen?"},"content":{"rendered":"<article class=\"blog-post\" lang=\"de\"><header>\n<p>Systemintegratoren, Schaltschrankbauer und Beschaffungsteams in der Bewegungssteuerung verlieren selten Zeit, weil der Servo-Algorithmus falsch ist. Sie verlieren sie, wenn ein Antrieb w\u00e4hrend eines ESD-Ereignisses am Encoder-Stecker zur\u00fccksetzt, wenn ein Surge auf der 24V-Hilfsschiene den Schnittstellen-Transceiver zerst\u00f6rt, oder wenn das Ger\u00e4t den Funktionstest auf dem Pr\u00fcfplatz besteht und die St\u00f6rfestigkeit im akkreditierten Labor nicht besteht\u2014was ein PCBA-Redesign, einen neuen Layout-Spin und einen verz\u00f6gerten Maschinenstart erzwingt.<\/p>\n<p>Die <a href=\"https:\/\/tps-elektronik.com\/services\/ems\/pcb-bestueckung\/\">Industrial-Control-PCBA-Services<\/a> von TPS Elektronik sind darauf ausgelegt, dieses Risiko zu reduzieren: Schutzstufenintegration am Stecker, Massepartitionierung vor Layout-Freigabe und EMC-orientierte Montage und Inspektion vom Prototyp bis zur Serienproduktion.<\/p>\n<p><a class=\"cta-primary\" href=\"https:\/\/tps-elektronik.com\/services\/ems\/pcb-bestueckung\/\">Besprechen Sie Ihre Servoantrieb-PCBA-EMC-Anforderungen mit TPS \u2192<\/a><\/p>\n<\/header><nav class=\"toc\" aria-label=\"Inhaltsverzeichnis\">\n<h2 id=\"toc\">Inhaltsverzeichnis<\/h2>\n<ol>\n<li><a href=\"#was-die-anforderungen-bedeuten\">Was \u00b14kV Surge und \u00b115kV ESD f\u00fcr eine Servoantrieb-PCBA tats\u00e4chlich bedeuten<\/a>\n<ol>\n<li><a href=\"#esd-pegel\">IEC 61000-4-2 ESD: Kontakt- vs. Luftentladung<\/a><\/li>\n<li><a href=\"#surge-pegel\">IEC 61000-4-5 Surge: Kombinationswelle und Quellimpedanz<\/a><\/li>\n<li><a href=\"#produktnorm\">IEC 61800-3: die Produktnorm, die beides verbindet<\/a><\/li>\n<\/ol>\n<\/li>\n<li><a href=\"#ausfallmechanismen\">Warum Servoantrieb-PCBAs diese Tests nicht bestehen<\/a>\n<ol>\n<li><a href=\"#stecker-eintritt\">Der Stecker ist der Eintrittspunkt<\/a><\/li>\n<li><a href=\"#masse-verschmutzung\">Masseverschmutzung zwischen Leistungs-, Digital- und Analogsbereich<\/a><\/li>\n<\/ol>\n<\/li>\n<li><a href=\"#pcba-design\">PCBA-Ma\u00dfnahmen, die den Unterschied machen<\/a>\n<ol>\n<li><a href=\"#schutzstufe\">Platzierung der Schutzstufe und Komponentenauswahl<\/a><\/li>\n<li><a href=\"#layout-regeln\">Layout- und Erdungsregeln<\/a><\/li>\n<li><a href=\"#isolation\">Isolationskoordination<\/a><\/li>\n<\/ol>\n<\/li>\n<li><a href=\"#tps-rolle\">Wie TPS Industrial-Control-PCBA-Services EMC-first-Fertigung unterst\u00fctzen<\/a>\n<ol>\n<li><a href=\"#dfm-review\">DFM-Pr\u00fcfung mit Fokus auf EMC-Risiko<\/a><\/li>\n<li><a href=\"#montage\">Montage, Inspektion und Schutzintegrit\u00e4t<\/a><\/li>\n<li><a href=\"#dokumentation\">Dokumentation f\u00fcr die Zertifizierungsakte<\/a><\/li>\n<\/ol>\n<\/li>\n<li><a href=\"#rfq-checkliste\">RFQ-Checkliste f\u00fcr EMC-kritische Servoantrieb-PCBA<\/a><\/li>\n<li><a href=\"#faq\">FAQ<\/a><\/li>\n<\/ol>\n<\/nav>\n<section id=\"was-die-anforderungen-bedeuten\">\n<h2>1. Was \u00b14kV Surge und \u00b115kV ESD f\u00fcr eine Servoantrieb-PCBA tats\u00e4chlich bedeuten<\/h2>\n<p>Die Zahlen \u00b14kV und \u00b115kV sind nicht willk\u00fcrlich. Sie stammen aus den grundlegenden St\u00f6rfestigkeitsnormen, auf die die Servoantrieb-Produktnorm verweist, und sie werden auf bestimmte Ports des Antriebs angewendet, nicht auf die PCBA als Ganzes.<\/p>\n<h3 id=\"esd-pegel\">1.1 IEC 61000-4-2 ESD: Kontakt- vs. Luftentladung<\/h3>\n<p>IEC 61000-4-2 definiert vier Testpegel. Pegel 4 entspricht <strong>8kV Kontaktentladung und 15kV Luftentladung<\/strong>. In der Servoantrieb-Praxis wird die Kontaktentladung auf zug\u00e4ngliche leitf\u00e4hige Teile angewendet\u2014Steckergeh\u00e4use, Montageschrauben, Chassis\u2014w\u00e4hrend die Luftentladung auf isolierte Oberfl\u00e4chen und Schlitze angewendet wird. Eine Servoantrieb-Spezifikation von \u201e\u00b115kV\u201c bezieht sich typischerweise auf den Luftentladungspegel, mit Kontaktentladung auf einem niedrigeren, aber immer noch strengen Pegel (oft \u00b14kV oder \u00b18kV) je nach zug\u00e4nglichem Metall.<\/p>\n<p>Die Wellenform ist das Human-Body-Modell: Ein 150pF-Kondensator entl\u00e4dt sich \u00fcber einen 330\u03a9-Widerstand. Die Anstiegszeit liegt unter 1ns, und der Spitzenstrom bei 8kV Kontakt kann 30A \u00fcberschreiten. Dieser Strom muss einen niederimpedanten Pfad zur Chassis-Masse finden, ohne die empfindliche Steuerelektronik zu durchqueren.<\/p>\n<h3 id=\"surge-pegel\">1.2 IEC 61000-4-5 Surge: Kombinationswelle und Quellimpedanz<\/h3>\n<p>IEC 61000-4-5 verwendet eine <strong>1,2\/50\u00b5s Leerlaufspannungs-Wellenform und eine 8\/20\u00b5s Kurzschlussstrom-Wellenform<\/strong>, erzeugt von einem Kombinationswellengenerator mit definierter Quellimpedanz. F\u00fcr AC-Netzports betr\u00e4gt die effektive Ausgangsimpedanz 2\u03a9; f\u00fcr einige DC- und Signalports 42\u03a9.<\/p>\n<p>Ein \u00b14kV Surge bei 2\u03a9 repr\u00e4sentiert einen Spitzenstrom von bis zu 2kA, mit einer Kurzschlussenergie, die einen ungesch\u00fctzten TVS oder einen kleinen Gleichrichter zerst\u00f6ren kann. Der PCBA-Designer muss daher Schutzkomponenten mit einer Surge-Bemessung \u00fcber dem Testpegel ausw\u00e4hlen und sicherstellen, dass der Surge-Strompfad kein Kupfer mit der Steuermasse teilt.<\/p>\n<h3 id=\"produktnorm\">1.3 IEC 61800-3: die Produktnorm, die beides verbindet<\/h3>\n<p>F\u00fcr drehzahlver\u00e4nderbare Antriebe ist <strong>IEC 61800-3<\/strong> die EMC-Produktnorm. Sie spezifiziert St\u00f6rfestigkeitsanforderungen und Abnahmekriterien und verweist f\u00fcr die Testmethoden auf die IEC 61000-4-x-Serie. Die praktische Konsequenz f\u00fcr Beschaffung und Engineering ist, dass die PCBA nicht isoliert \u201eESD-bestehen\u201c kann; sie muss so ausgelegt sein, dass der komplette Antrieb die St\u00f6rfestigkeitsanforderungen an den Ports erf\u00fcllt, die IEC 61800-3 identifiziert\u2014Netz, Motorausgang, Encoder-Feedback, Kommunikation und E\/A.<\/p>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-19318\" src=\"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/10\/Industrial-Control-PCBA-Servo-Drive-EMC-Test-1-1.jpg\" alt=\"Industrial Control PCBA Servo Drive EMC Test\" width=\"1920\" height=\"1079\" \/><\/p>\n<p><a class=\"cta-primary\" href=\"https:\/\/tps-elektronik.com\/services\/ems\/pcb-bestueckung\/\">TPS PCBA-Montagef\u00e4higkeiten erkunden \u2192<\/a><\/p>\n<\/section>\n<section id=\"ausfallmechanismen\">\n<h2>2. Warum Servoantrieb-PCBAs diese Tests nicht bestehen<\/h2>\n<p>Die meisten ESD- und Surge-Ausf\u00e4lle auf Servoantrieb-PCBAs werden nicht durch eine fehlende Schutzkomponente verursacht. Sie werden durch den Platz der Schutzvorrichtung, den Stromfluss und die Massepartitionierung verursacht.<\/p>\n<h3 id=\"stecker-eintritt\">2.1 Der Stecker ist der Eintrittspunkt<\/h3>\n<p>ESD und Surge treten durch Stecker ein: Encoder-Feedback (oft ein geschirmter Mehrpolstecker), Kommunikationsports (RS-485, CAN, Ethernet), digitale E\/A und die DC-Hilfsversorgung. Wenn die Schutzvorrichtung nach einer langen Leiterbahn vom Stecker platziert wird, erh\u00f6ht die Leiterbahninduktivit\u00e4t die Klemmspannung am IC, und der IC sieht einen Transienten, den der TVS entfernen sollte.<\/p>\n<p>Feldpraxis und ver\u00f6ffentlichte Designhinweise laufen auf dieselbe Regel hinaus: Die Schutzvorrichtung muss <strong>so nah wie m\u00f6glich am Stecker<\/strong> platziert werden, mit kurzer und direkter Leiterbahn vom Stecker zur Schutzvorrichtung. Die gesch\u00fctzte Leiterbahn f\u00fchrt dann zum Transceiver.<\/p>\n<h3 id=\"masse-verschmutzung\">2.2 Masseverschmutzung zwischen Leistungs-, Digital- und Analogsbereich<\/h3>\n<p>Eine Servoantrieb-PCBA enth\u00e4lt mindestens drei Massebereiche: Leistungsmasse, die die IGBT\/MOSFET-Schaltstr\u00f6me f\u00fchrt, Digitalmasse f\u00fcr DSP\/MCU und Kommunikation, und Analogmasse f\u00fcr Strommessung und Encoder-Signalaufbereitung. Wenn diese eine gemeinsame Kupferfl\u00e4che teilen, entwickelt das Schalt-di\/dt eine Spannungsdifferenz \u00fcber die Massefl\u00e4che, und diese Differenz erscheint als Gleichtaktrauschen am Analog-Frontend.<\/p>\n<p>Der Korrekturansatz ist physische Partitionierung: getrennte Kupferfl\u00e4chen f\u00fcr Leistungs-, Digital- und Analogmasse, an einem einzigen Punkt verbunden\u2014typischerweise nahe dem DC-Eingang oder der Isolationsbarriere\u2014\u00fcber eine Ferritperle oder eine 0\u03a9-Verbindung. Mehrere Durchkontaktierungen zwischen den Bereichen vereiteln den Zweck, weil sie parallele Pfade f\u00fcr das Rauschen schaffen.<\/p>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-19313\" src=\"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/10\/\u00b14kV-Surge-\u00b115kV-ESD-PCBA-Protection-Circuit-2.jpg\" alt=\"\u00b14kV Surge \u00b115kV ESD PCBA Protection Circuit\" width=\"1920\" height=\"1079\" \/><\/p>\n<p><a class=\"cta-primary\" href=\"https:\/\/tps-elektronik.com\/services\/ems\/pcb-bestueckung\/\">PCBA-EMC-Designpr\u00fcfung anfordern \u2192<\/a><\/p>\n<\/section>\n<section id=\"pcba-design\">\n<h2>3. PCBA-Ma\u00dfnahmen, die den Unterschied machen<\/h2>\n<p>Die folgenden Ma\u00dfnahmen sind nicht neu, aber ihre Umsetzung entscheidet dar\u00fcber, ob der Antrieb beim ersten Versuch besteht oder einen Layout-Respin erfordert.<\/p>\n<h3 id=\"schutzstufe\">3.1 Platzierung der Schutzstufe und Komponentenauswahl<\/h3>\n<p>F\u00fcr ESD an Kommunikations- und Encoder-Steckern ist die Standardanordnung ein <strong>Serienwiderstand (22\u2013100\u03a9) gefolgt von einem kapazit\u00e4tsarmen TVS gegen Chassis-Masse<\/strong>, platziert am Stecker. Der Serienwiderstand begrenzt den Strom in den Transceiver; der TVS klemmt die Spannung; die niedrige Kapazit\u00e4t erh\u00e4lt die Signalintegrit\u00e4t bei Encoder-Frequenzen.<\/p>\n<p>F\u00fcr Surge am DC-Hilfseingang und am Netzeingang ist die Schutzstufe typischerweise ein <strong>Varistor oder TVS mit einer Surge-Bemessung \u00fcber dem Testpegel<\/strong>, gefolgt von einer Gleichtaktdrossel und einem Bulk-Kondensator. Die Varistorspannung muss \u00fcber der maximalen Dauerbetriebsspannung, aber niedrig genug gew\u00e4hlt werden, um zu klemmen, bevor die nachgeschalteten Komponenten ihre Bemessung \u00fcberschreiten.<\/p>\n<h3 id=\"layout-regeln\">3.2 Layout- und Erdungsregeln<\/h3>\n<p>Drei Layout-Regeln z\u00e4hlen f\u00fcr ESD und Surge mehr als alle anderen:<\/p>\n<ul>\n<li><strong>Schutz am Port, R\u00fcckf\u00fchrung auf Chassis:<\/strong> Die TVS-R\u00fcckf\u00fchrung muss \u00fcber eine kurze, breite Leiterbahn oder eine dedizierte Massefl\u00e4che mit Chassis-Masse verbunden werden, nicht mit Digitalmasse.<\/li>\n<li><strong>Gesch\u00fctzte Leiterbahn von ungesch\u00fctzter fernhalten:<\/strong> Nach der Schutzvorrichtung darf die Leiterbahn nicht parallel zur ankommenden Leitung verlaufen, sonst koppelt der Transient \u00fcber.<\/li>\n<li><strong>Schirmbondung:<\/strong> Der Steckerschirm muss mit einer niederimpedanten Verbindung (m\u00f6glichst 360\u00b0) auf Chassis gebondet werden. Eine Einzeldraht-\u201ePigtail\u201c-Verbindung macht den Schirm zur Antenne.<\/li>\n<\/ul>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-19308\" src=\"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/10\/Servo-Drive-PCBA-Ground-Partitioning-EMC-Layout-3.jpg\" alt=\"Servo Drive PCBA Ground Partitioning EMC Layout\" width=\"1920\" height=\"1079\" \/><\/p>\n<h3 id=\"isolation\">3.3 Isolationskoordination<\/h3>\n<p>Servoantriebe verwenden verst\u00e4rkte Isolierung zwischen der Hochspannungs-Leistungsstufe und der Niederspannungs-Steuerseite. Die Isolationsbarriere ist auch eine EMC-Grenze: Surge- und ESD-Str\u00f6me d\u00fcrfen sie nicht \u00fcber eine gemeinsame Masse oder eine gemeinsame Schutzr\u00fcckf\u00fchrung \u00fcberbr\u00fccken. Der isolierte Gate-Treiber, die isolierte Encoder-Schnittstelle und der isolierte Kommunikations-Transceiver m\u00fcssen jeweils mit ihrem Schutz auf der korrekten Seite der Barriere referenziert sein.<\/p>\n<p>F\u00fcr die PCBA-Fertigung bedeutet dies, dass die Montagezeichnung die Isolationsbarriere klar spezifizieren muss und die Testvorrichtung die Isolationsfestigkeit nach der Montage verifizieren muss\u2014nicht nur in der Designphase.<\/p>\n<\/section>\n<section id=\"tps-rolle\">\n<h2>4. Wie TPS Industrial-Control-PCBA-Services EMC-first-Fertigung unterst\u00fctzen<\/h2>\n<p>TPS Elektronik ist ein EMS-Anbieter mit einem leistungselektronischen Engineering-Team und 25 Jahren Erfahrung in Leistungswandlung und Steuerungshardware. Der PCBA-Serviceumfang umfasst SMT- und THT-Montage, Inspektion und Test, mit einer Engineering-Schnittstelle, die EMC-Risiken pr\u00fcft, bevor das Layout freigegeben wird.<\/p>\n<h3 id=\"dfm-review\">4.1 DFM-Pr\u00fcfung mit Fokus auf EMC-Risiko<\/h3>\n<p>Die DFM-Pr\u00fcfung ist der erste Kontrollpunkt. TPS-Ingenieure pr\u00fcfen die Platzierung der Schutzstufe, die Massepartitionierung, die Steckerschirmbondung und die Isolationsbarriere gegen Schaltbild und Layout. Das Ergebnis ist eine Liste umsetzbarer \u00c4nderungen vor Werkzeugbau und Montage, nicht nach dem ersten EMC-Fehler.<\/p>\n<h3 id=\"montage\">4.2 Montage, Inspektion und Schutzintegrit\u00e4t<\/h3>\n<p>ESD- und Surge-Leistung h\u00e4ngt von der physischen Integrit\u00e4t der Schutzkomponenten und ihrer L\u00f6tstellen ab. Ein TVS mit einer hohlen L\u00f6tstelle verh\u00e4lt sich wie kein TVS. Die Montage- und Inspektionsprozesse von TPS\u2014einschlie\u00dflich AOI und Funktionstest\u2014sind darauf konfiguriert, zu verifizieren, dass Schutzkomponenten vorhanden, korrekt orientiert und ordnungsgem\u00e4\u00df verl\u00f6tet sind.<\/p>\n<h3 id=\"dokumentation\">4.3 Dokumentation f\u00fcr die Zertifizierungsakte<\/h3>\n<p>F\u00fcr die technische Akte des Antriebs und den EMC-Testbericht sollte die Dokumentation des PCBA-Herstellers die Montagezeichnung mit markierter Schutzstufe, die St\u00fcckliste mit den Surge\/ESD-Bemessungen der Schutzkomponenten und die Inspektionsaufzeichnungen enthalten. TPS stellt diese Dokumentation als Teil der PCBA-Lieferung bereit, sodass der Schaltschrankbauer oder OEM sie w\u00e4hrend der Zertifizierung referenzieren kann.<\/p>\n<p><a class=\"cta-primary\" href=\"https:\/\/tps-elektronik.com\/services\/ems\/pcb-bestueckung\/\">Ihre Servoantrieb-PCBA-RFQ einreichen \u2192<\/a><\/p>\n<\/section>\n<section id=\"rfq-checkliste\">\n<h2>5. RFQ-Checkliste f\u00fcr EMC-kritische Servoantrieb-PCBA<\/h2>\n<p>Um Angebotserstellung und Engineering-Pr\u00fcfung f\u00fcr eine <strong>Industrial Control PCBA<\/strong> mit Surge- und ESD-Anforderungen zu beschleunigen, geben Sie die folgenden Informationen an:<\/p>\n<ul>\n<li><strong>St\u00f6rfestigkeitsziele<\/strong>: ESD-Kontakt- und Luftentladungspegel, Surge-Pegel und Port (Netz, DC-Hilfe, Signal) und die anzuwendende Produktnorm (z. B. IEC 61800-3 Kategorie)<\/li>\n<li><strong>Portliste<\/strong>: Encoder-Feedback, Kommunikation (RS-485\/CAN\/Ethernet), digitale E\/A und DC-Hilfseingang mit Steckertypen<\/li>\n<li><strong>Schutzschaltbild<\/strong>: TVS\/Varistor-Teilenummern und -Bemessungen, Serienwiderst\u00e4nde, Gleichtaktdrosseln und die vorgesehene Massereferenz f\u00fcr jede Schutzvorrichtung<\/li>\n<li><strong>Massepartitionierung<\/strong>: Leistungs-, Digital- und Analogbereich und die vorgesehene Einpunktverbindung<\/li>\n<li><strong>Isolationsbarriere<\/strong>: Spannungsbemessung, Kriech-\/Luftstreckenanforderung und Isolationsnorm<\/li>\n<li><strong>PCB-Stack-up<\/strong>: Lagenzahl, Kupferdicke und impedanzkontrollierte Leiterbahnen<\/li>\n<li><strong>Testanforderungen<\/strong>: Ob der PCBA-Lieferant Funktionstest und Schutzverifikation durchf\u00fchrt und den Testumfang<\/li>\n<li><strong>Dokumentation<\/strong>: Montagezeichnung, St\u00fcckliste mit Schutz-Bemessungen, Inspektionsaufzeichnungen und R\u00fcckverfolgbarkeit<\/li>\n<li><strong>Volumen und Zeitplan<\/strong>: Prototyp-, Pilot- und Serienmengen<\/li>\n<\/ul>\n<p>Die Angabe dieser Details reduziert Kl\u00e4rungszyklen. Das Engineering-Team von TPS kann Schutzstufenpr\u00fcfung, Massepartitionierung und Testumfangsdefinition als Teil des RFQ-Prozesses unterst\u00fctzen.<\/p>\n<\/section>\n<section id=\"faq\">\n<h2>6. FAQ<\/h2>\n<div>\n<h3>Was bedeutet \u00b115kV ESD f\u00fcr eine Servoantrieb-PCBA\u2014Kontakt- oder Luftentladung?<\/h3>\n<div>\n<div>In den meisten Servoantrieb-Spezifikationen bezieht sich \u00b115kV auf den Luftentladungs-Testpegel nach IEC 61000-4-2 Pegel 4. Die Kontaktentladung wird auf einem niedrigeren, aber immer noch strengen Pegel\u2014typischerweise \u00b14kV oder \u00b18kV\u2014auf zug\u00e4ngliche Metallteile wie Steckergeh\u00e4use und Montageschrauben angewendet. Das PCBA-Design muss beides bew\u00e4ltigen: Kontaktentladung belastet den Chassis-Massepfad, Luftentladung belastet die Isolierung und die Steckerschnittstelle.<\/div>\n<\/div>\n<h3>Ist ein \u00b14kV Surge-Test f\u00fcr AC-Netz- und DC-Hilfsports gleich?<\/h3>\n<div>\n<div>Nein. IEC 61000-4-5 spezifiziert unterschiedliche Quellimpedanzen f\u00fcr verschiedene Porttypen. AC-Netzports verwenden eine effektive Quellimpedanz von 2\u03a9, was bei \u00b14kV einen sehr hohen Spitzenstrom erzeugt. Einige DC- und Signalports verwenden eine h\u00f6here Impedanz (z. B. 42\u03a9), was die Stromwellenform und die Energie \u00e4ndert, die die Schutzvorrichtung sieht. Die Schutz-Bemessung muss f\u00fcr die spezifische Portimpedanz und den Testpegel ausgew\u00e4hlt werden.<\/div>\n<\/div>\n<h3>Warum ist Massepartitionierung f\u00fcr ESD und Surge wichtig?<\/h3>\n<div>\n<div>Wenn Leistungs-, Digital- und Analogmasse eine gemeinsame Kupferfl\u00e4che teilen, erzeugen die Schaltstr\u00f6me der Leistungsstufe Spannungsdifferenzen \u00fcber die Massefl\u00e4che. ESD- und Surge-Str\u00f6me addieren sich zu dieser St\u00f6rung und k\u00f6nnen in den Analog- und Digitalbereich einkoppeln. Die Trennung der Massen und ihre Verbindung an einem einzigen Punkt zwingt den Transientenstrom, zu seiner Quelle zur\u00fcckzukehren, ohne die empfindliche Schaltung zu durchqueren.<\/div>\n<\/div>\n<h3>Kann TPS die EMC-Vorpr\u00fcfung f\u00fcr die PCBA durchf\u00fchren?<\/h3>\n<div>\n<div>Der PCBA-Service von TPS konzentriert sich auf Design-for-EMC-Pr\u00fcfung, Montage, Inspektion und Funktionstest. Die EMC-Vorpr\u00fcfung ist ein separater Laborservice. Die von TPS bereitgestellte PCBA-Dokumentation unterst\u00fctzt den anschlie\u00dfenden EMC-Test in einem akkreditierten oder Vorpr\u00fcfungslabor. Kontaktieren Sie TPS \u00fcber die <a href=\"https:\/\/tps-elektronik.com\/services\/ems\/pcb-bestueckung\/\">PCBA-Service-Seite<\/a>, um den Umfang zu definieren.<\/div>\n<\/div>\n<h3>Welche Produktnorm gilt f\u00fcr die EMC-St\u00f6rfestigkeit des Servoantriebs?<\/h3>\n<div>\n<div>IEC 61800-3 ist die EMC-Produktnorm f\u00fcr drehzahlver\u00e4nderbare elektrische Antriebssysteme. Sie spezifiziert die St\u00f6rfestigkeitsanforderungen und Abnahmekriterien und verweist f\u00fcr die Testmethoden auf die IEC 61000-4-x-Serie, einschlie\u00dflich IEC 61000-4-2 f\u00fcr ESD und IEC 61000-4-5 f\u00fcr Surge.<\/div>\n<\/div>\n<\/div>\n<\/section>\n<footer style=\"background: #2d5797; padding: 30px; border-radius: 14px; margin-top: 40px;\">\n<p style=\"color: #ffffff; font-size: 16px; line-height: 1.6; margin: 0;\"><strong>Bereit, eine Servoantrieb-PCBA zu bauen, die \u00b14kV Surge und \u00b115kV ESD \u00fcbersteht?<\/strong><br \/>Kontaktieren Sie TPS Elektronik f\u00fcr EMC-fokussierte DFM-Pr\u00fcfung, Schutzstufenintegration, Massepartitionierung und Montageinspektion\u2014vom Prototyp bis zur Serienproduktion.<br \/><a style=\"color: #ffffff; font-weight: 600; text-decoration: underline;\" href=\"https:\/\/tps-elektronik.com\/services\/ems\/pcb-bestueckung\/\">Ihre PCBA-EMC-Beratung anfragen \u2192<\/a><\/p>\n<\/footer><\/article>\n\n<style id=\"wpforms-css-vars-4336-block-ae8a744d-336c-423f-b2e1-bb1c5b6e1072\">\n\t\t\t\t#wpforms-4336.wpforms-block-ae8a744d-336c-423f-b2e1-bb1c5b6e1072 {\n\t\t\t\t--wpforms-field-size-input-height: 43px;\n--wpforms-field-size-input-spacing: 15px;\n--wpforms-field-size-font-size: 16px;\n--wpforms-field-size-line-height: 19px;\n--wpforms-field-size-padding-h: 14px;\n--wpforms-field-size-checkbox-size: 16px;\n--wpforms-field-size-sublabel-spacing: 5px;\n--wpforms-field-size-icon-size: 1;\n--wpforms-label-size-font-size: 16px;\n--wpforms-label-size-line-height: 19px;\n--wpforms-label-size-sublabel-font-size: 14px;\n--wpforms-label-size-sublabel-line-height: 17px;\n--wpforms-button-size-font-size: 17px;\n--wpforms-button-size-height: 41px;\n--wpforms-button-size-padding-h: 15px;\n--wpforms-button-size-margin-top: 10px;\n\t\t\t}\n\t\t\t<\/style><div class=\"wpforms-container wpforms-container-full wpforms-block wpforms-block-ae8a744d-336c-423f-b2e1-bb1c5b6e1072 wpforms-render-modern\" id=\"wpforms-4336\"><form id=\"wpforms-form-4336\" class=\"wpforms-validate wpforms-form wpforms-ajax-form\" data-formid=\"4336\" method=\"post\" enctype=\"multipart\/form-data\" action=\"\/ar\/wp-json\/wp\/v2\/posts\/19181\" data-token=\"a9e51f98d9e31e22284f5ec986430d6b\" data-token-time=\"1794369838\"><noscript class=\"wpforms-error-noscript\">Please enable JavaScript in your browser to complete this form.<\/noscript><div id=\"wpforms-error-noscript\" style=\"display: none;\">Please enable JavaScript in your browser to complete this form.<\/div><div class=\"wpforms-field-container\"><div id=\"wpforms-4336-field_1-container\" class=\"wpforms-field wpforms-field-name wpforms-one-half wpforms-first\" data-field-id=\"1\"><label class=\"wpforms-field-label\" for=\"wpforms-4336-field_1\">Name <span class=\"wpforms-required-label\" aria-hidden=\"true\">*<\/span><\/label><input type=\"text\" id=\"wpforms-4336-field_1\" class=\"wpforms-field-large wpforms-field-required\" name=\"wpforms[fields][1]\" aria-errormessage=\"wpforms-4336-field_1-error\" required><\/div><div id=\"wpforms-4336-field_2-container\" class=\"wpforms-field wpforms-field-email\" data-field-id=\"2\"><label class=\"wpforms-field-label\" for=\"wpforms-4336-field_2\">E-Mail <span class=\"wpforms-required-label\" aria-hidden=\"true\">*<\/span><\/label><input type=\"email\" id=\"wpforms-4336-field_2\" class=\"wpforms-field-large wpforms-field-required\" name=\"wpforms[fields][2]\" spellcheck=\"false\" aria-errormessage=\"wpforms-4336-field_2-error\" required><\/div><div id=\"wpforms-4336-field_4-container\" class=\"wpforms-field wpforms-field-text\" data-field-id=\"4\"><label class=\"wpforms-field-label\" for=\"wpforms-4336-field_4\"> Firma <span class=\"wpforms-required-label\" aria-hidden=\"true\">*<\/span><\/label><input type=\"text\" id=\"wpforms-4336-field_4\" class=\"wpforms-field-large wpforms-field-required\" name=\"wpforms[fields][4]\" aria-errormessage=\"wpforms-4336-field_4-error\" required><\/div>\t\t<div id=\"wpforms-4336-field_5-container\"\n\t\t\tclass=\"wpforms-field wpforms-field-text\"\n\t\t\tdata-field-type=\"text\"\n\t\t\tdata-field-id=\"5\"\n\t\t\t>\n\t\t\t<label class=\"wpforms-field-label\" for=\"wpforms-4336-field_5\" >Kurzbeschreibung Firma Checkboxes<\/label>\n\t\t\t<input type=\"text\" id=\"wpforms-4336-field_5\" class=\"wpforms-field-medium\" name=\"wpforms[fields][5]\" >\n\t\t<\/div>\n\t\t<div id=\"wpforms-4336-field_3-container\" class=\"wpforms-field wpforms-field-textarea\" data-field-id=\"3\"><label class=\"wpforms-field-label\" for=\"wpforms-4336-field_3\">Kurzbeschreibung<\/label><textarea id=\"wpforms-4336-field_3\" class=\"wpforms-field-medium\" name=\"wpforms[fields][3]\" aria-errormessage=\"wpforms-4336-field_3-error\" ><\/textarea><\/div><div id=\"wpforms-4336-field_6-container\" class=\"wpforms-field wpforms-field-checkbox\" data-field-id=\"6\"><fieldset><legend class=\"wpforms-field-label wpforms-label-hide\" aria-hidden=\"false\">Checkboxes <span class=\"wpforms-required-label\" aria-hidden=\"true\">*<\/span><\/legend><ul id=\"wpforms-4336-field_6\" class=\"wpforms-field-required\"><li class=\"choice-1 depth-1\"><input type=\"checkbox\" id=\"wpforms-4336-field_6_1\" name=\"wpforms[fields][6][]\" value=\"Ich stimme der Verarbeitung meiner Angaben zur Angebotserstellung zu.\" aria-errormessage=\"wpforms-4336-field_6_1-error\" aria-describedby=\"wpforms-4336-field_6-description\" required ><label class=\"wpforms-field-label-inline\" for=\"wpforms-4336-field_6_1\">Ich stimme der Verarbeitung meiner Angaben zur Angebotserstellung zu.<\/label><\/li><\/ul><div id=\"wpforms-4336-field_6-description\" class=\"wpforms-field-description\">Hinweise siehe Datenschutz.<\/div><\/fieldset><\/div><script>\n\t\t\t\t( function() {\n\t\t\t\t\tconst style = document.createElement( 'style' );\n\t\t\t\t\tstyle.appendChild( document.createTextNode( '#wpforms-4336-field_5-container { position: absolute !important; overflow: hidden !important; display: inline !important; height: 1px !important; width: 1px !important; z-index: -1000 !important; padding: 0 !important; } #wpforms-4336-field_5-container input { visibility: hidden; } #wpforms-conversational-form-page #wpforms-4336-field_5-container label { counter-increment: none; }' ) );\n\t\t\t\t\tdocument.head.appendChild( style );\n\t\t\t\t\tdocument.currentScript?.remove();\n\t\t\t\t} )();\n\t\t\t<\/script><\/div><!-- .wpforms-field-container --><div class=\"wpforms-recaptcha-container wpforms-is-turnstile\" ><div class=\"wpforms-turnstile\" data-sitekey=\"0x4AAAAAAFUTE-Rr1O4nxKnU\" data-action=\"FormID-4336\"><\/div><input type=\"text\" name=\"g-recaptcha-hidden\" class=\"wpforms-recaptcha-hidden\" style=\"position:absolute!important;clip:rect(0,0,0,0)!important;height:1px!important;width:1px!important;border:0!important;overflow:hidden!important;padding:0!important;margin:0!important;\" data-rule-turnstile=\"1\"><\/div><div class=\"wpforms-submit-container\" ><input type=\"hidden\" name=\"wpforms[id]\" value=\"4336\"><input type=\"hidden\" name=\"wpforms[time_token]\" value=\"1794369838.61cc580a8f416f9e0331c86142b1a3c99edf86d35e4311770a72b64f37891c1e\"><input type=\"hidden\" name=\"page_title\" value=\"\"><input type=\"hidden\" name=\"page_url\" value=\"https:\/\/tps-elektronik.com\/ar\/wp-json\/wp\/v2\/posts\/19181\"><input type=\"hidden\" name=\"url_referer\" value=\"\"><button type=\"submit\" name=\"wpforms[submit]\" id=\"wpforms-submit-4336\" class=\"wpforms-submit\" data-alt-text=\"Senden...\" data-submit-text=\"Anfrage senden\" aria-live=\"assertive\" value=\"wpforms-submit\">Anfrage senden<\/button><img decoding=\"async\" src=\"https:\/\/tps-elektronik.com\/wp-content\/plugins\/wpforms-lite\/assets\/images\/submit-spin.svg\" class=\"wpforms-submit-spinner\" style=\"display: none;\" width=\"26\" height=\"26\" alt=\"Loading\"><\/div><\/form><\/div>  <!-- .wpforms-container -->","protected":false},"excerpt":{"rendered":"<p>Systemintegratoren, Schaltschrankbauer und Beschaffungsteams in der Bewegungssteuerung verlieren selten Zeit, weil der Servo-Algorithmus falsch ist. Sie verlieren sie, wenn ein Antrieb w\u00e4hrend eines ESD-Ereignisses am Encoder-Stecker zur\u00fccksetzt, wenn ein Surge auf der 24V-Hilfsschiene den Schnittstellen-Transceiver zerst\u00f6rt, oder wenn das Ger\u00e4t den Funktionstest auf dem Pr\u00fcfplatz besteht und die St\u00f6rfestigkeit im akkreditierten Labor nicht besteht\u2014was ein\u2026 <a href=\"https:\/\/tps-elektronik.com\/ar\/how-to-pass-emc-surge-%c2%b14kv-and-esd-%c2%b115kv-requirements-in-servo-drive-pcba-with-tps-industrial-control-pcba-services\/\">Read More &raquo;<\/a><\/p>\n","protected":false},"author":9,"featured_media":19318,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[59],"tags":[],"class_list":["post-19181","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog-inhalt"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Wie lassen sich die EMV-Anforderungen f\u00fcr Sto\u00dfspannungen (Surge) von \u00b14 kV sowie f\u00fcr elektrostatische Entladungen (ESD) von \u00b115 kV bei Leiterplatten f\u00fcr Servoantriebe mithilfe der Dienstleistungen von TPS f\u00fcr industrielle Steuerungs-Leiterplatten erf\u00fcllen? - TPS<\/title>\n<meta name=\"description\" content=\"industrial control pcba f\u00fcr industrielle Servosteuerungen m\u00fcssen Sto\u00dfspannungen von \u00b14 kV sowie ESD-Ereignisse von \u00b115 kV \u00fcberstehen. Die PCBA-Dienstleistungen von TPS umfassen Schutzma\u00dfnahmen, Layout-Design und Tests.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/tps-elektronik.com\/ar\/how-to-pass-emc-surge-%c2%b14kv-and-esd-%c2%b115kv-requirements-in-servo-drive-pcba-with-tps-industrial-control-pcba-services\/\" \/>\n<meta property=\"og:locale\" content=\"ar_AR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Wie lassen sich die EMV-Anforderungen f\u00fcr Sto\u00dfspannungen (Surge) von \u00b14 kV sowie f\u00fcr elektrostatische Entladungen (ESD) von \u00b115 kV bei Leiterplatten f\u00fcr Servoantriebe mithilfe der Dienstleistungen von TPS f\u00fcr industrielle Steuerungs-Leiterplatten erf\u00fcllen? - TPS\" \/>\n<meta property=\"og:description\" content=\"industrial control pcba f\u00fcr industrielle Servosteuerungen m\u00fcssen Sto\u00dfspannungen von \u00b14 kV sowie ESD-Ereignisse von \u00b115 kV \u00fcberstehen. Die PCBA-Dienstleistungen von TPS umfassen Schutzma\u00dfnahmen, Layout-Design und Tests.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/tps-elektronik.com\/ar\/how-to-pass-emc-surge-%c2%b14kv-and-esd-%c2%b115kv-requirements-in-servo-drive-pcba-with-tps-industrial-control-pcba-services\/\" \/>\n<meta property=\"og:site_name\" content=\"TPS\" \/>\n<meta property=\"article:published_time\" content=\"2026-11-09T08:00:00+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/10\/Industrial-Control-PCBA-Servo-Drive-EMC-Test-1-1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1920\" \/>\n\t<meta property=\"og:image:height\" content=\"1079\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Tang Marcus\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u0643\u064f\u062a\u0628 \u0628\u0648\u0627\u0633\u0637\u0629\" \/>\n\t<meta name=\"twitter:data1\" content=\"Tang Marcus\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u0648\u0642\u062a \u0627\u0644\u0642\u0631\u0627\u0621\u0629 \u0627\u0644\u0645\u064f\u0642\u062f\u0651\u0631\" \/>\n\t<meta name=\"twitter:data2\" content=\"9 \u062f\u0642\u0627\u0626\u0642\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/ar\\\/how-to-pass-emc-surge-%c2%b14kv-and-esd-%c2%b115kv-requirements-in-servo-drive-pcba-with-tps-industrial-control-pcba-services\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/ar\\\/how-to-pass-emc-surge-%c2%b14kv-and-esd-%c2%b115kv-requirements-in-servo-drive-pcba-with-tps-industrial-control-pcba-services\\\/\"},\"author\":{\"name\":\"Tang Marcus\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/ar\\\/#\\\/schema\\\/person\\\/2c19fd053095d0c1ae253e8e62427b8c\"},\"headline\":\"Wie lassen sich die EMV-Anforderungen f\u00fcr Sto\u00dfspannungen (Surge) von \u00b14 kV sowie f\u00fcr elektrostatische Entladungen (ESD) von \u00b115 kV bei Leiterplatten f\u00fcr Servoantriebe mithilfe der Dienstleistungen von TPS f\u00fcr industrielle Steuerungs-Leiterplatten erf\u00fcllen?\",\"datePublished\":\"2026-11-09T08:00:00+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/ar\\\/how-to-pass-emc-surge-%c2%b14kv-and-esd-%c2%b115kv-requirements-in-servo-drive-pcba-with-tps-industrial-control-pcba-services\\\/\"},\"wordCount\":1863,\"image\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/ar\\\/how-to-pass-emc-surge-%c2%b14kv-and-esd-%c2%b115kv-requirements-in-servo-drive-pcba-with-tps-industrial-control-pcba-services\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/tps-elektronik.com\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/Industrial-Control-PCBA-Servo-Drive-EMC-Test-1-1.jpg\",\"articleSection\":[\"Blog-Inhalt\"],\"inLanguage\":\"ar\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/ar\\\/how-to-pass-emc-surge-%c2%b14kv-and-esd-%c2%b115kv-requirements-in-servo-drive-pcba-with-tps-industrial-control-pcba-services\\\/\",\"url\":\"https:\\\/\\\/tps-elektronik.com\\\/ar\\\/how-to-pass-emc-surge-%c2%b14kv-and-esd-%c2%b115kv-requirements-in-servo-drive-pcba-with-tps-industrial-control-pcba-services\\\/\",\"name\":\"Wie lassen sich die EMV-Anforderungen f\u00fcr Sto\u00dfspannungen (Surge) von \u00b14 kV sowie f\u00fcr elektrostatische Entladungen (ESD) von \u00b115 kV bei Leiterplatten f\u00fcr Servoantriebe mithilfe der Dienstleistungen von TPS f\u00fcr industrielle Steuerungs-Leiterplatten erf\u00fcllen? - TPS\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/ar\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/ar\\\/how-to-pass-emc-surge-%c2%b14kv-and-esd-%c2%b115kv-requirements-in-servo-drive-pcba-with-tps-industrial-control-pcba-services\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/ar\\\/how-to-pass-emc-surge-%c2%b14kv-and-esd-%c2%b115kv-requirements-in-servo-drive-pcba-with-tps-industrial-control-pcba-services\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/tps-elektronik.com\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/Industrial-Control-PCBA-Servo-Drive-EMC-Test-1-1.jpg\",\"datePublished\":\"2026-11-09T08:00:00+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/ar\\\/#\\\/schema\\\/person\\\/2c19fd053095d0c1ae253e8e62427b8c\"},\"description\":\"industrial control pcba f\u00fcr industrielle Servosteuerungen m\u00fcssen Sto\u00dfspannungen von \u00b14 kV sowie ESD-Ereignisse von \u00b115 kV \u00fcberstehen. Die PCBA-Dienstleistungen von TPS umfassen Schutzma\u00dfnahmen, Layout-Design und Tests.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/ar\\\/how-to-pass-emc-surge-%c2%b14kv-and-esd-%c2%b115kv-requirements-in-servo-drive-pcba-with-tps-industrial-control-pcba-services\\\/#breadcrumb\"},\"inLanguage\":\"ar\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/tps-elektronik.com\\\/ar\\\/how-to-pass-emc-surge-%c2%b14kv-and-esd-%c2%b115kv-requirements-in-servo-drive-pcba-with-tps-industrial-control-pcba-services\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ar\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/ar\\\/how-to-pass-emc-surge-%c2%b14kv-and-esd-%c2%b115kv-requirements-in-servo-drive-pcba-with-tps-industrial-control-pcba-services\\\/#primaryimage\",\"url\":\"https:\\\/\\\/tps-elektronik.com\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/Industrial-Control-PCBA-Servo-Drive-EMC-Test-1-1.jpg\",\"contentUrl\":\"https:\\\/\\\/tps-elektronik.com\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/Industrial-Control-PCBA-Servo-Drive-EMC-Test-1-1.jpg\",\"width\":1920,\"height\":1079,\"caption\":\"Industrial Control PCBA Servo Drive EMC Test\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/ar\\\/how-to-pass-emc-surge-%c2%b14kv-and-esd-%c2%b115kv-requirements-in-servo-drive-pcba-with-tps-industrial-control-pcba-services\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Startseite\",\"item\":\"https:\\\/\\\/tps-elektronik.com\\\/ar\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Wie lassen sich die EMV-Anforderungen f\u00fcr Sto\u00dfspannungen (Surge) von \u00b14 kV sowie f\u00fcr elektrostatische Entladungen (ESD) von \u00b115 kV bei Leiterplatten f\u00fcr Servoantriebe mithilfe der Dienstleistungen von TPS f\u00fcr industrielle Steuerungs-Leiterplatten erf\u00fcllen?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/ar\\\/#website\",\"url\":\"https:\\\/\\\/tps-elektronik.com\\\/ar\\\/\",\"name\":\"TPS\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/tps-elektronik.com\\\/ar\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ar\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/ar\\\/#\\\/schema\\\/person\\\/2c19fd053095d0c1ae253e8e62427b8c\",\"name\":\"Tang Marcus\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Wie lassen sich die EMV-Anforderungen f\u00fcr Sto\u00dfspannungen (Surge) von \u00b14 kV sowie f\u00fcr elektrostatische Entladungen (ESD) von \u00b115 kV bei Leiterplatten f\u00fcr Servoantriebe mithilfe der Dienstleistungen von TPS f\u00fcr industrielle Steuerungs-Leiterplatten erf\u00fcllen? - TPS","description":"industrial control pcba f\u00fcr industrielle Servosteuerungen m\u00fcssen Sto\u00dfspannungen von \u00b14 kV sowie ESD-Ereignisse von \u00b115 kV \u00fcberstehen. Die PCBA-Dienstleistungen von TPS umfassen Schutzma\u00dfnahmen, Layout-Design und Tests.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/tps-elektronik.com\/ar\/how-to-pass-emc-surge-%c2%b14kv-and-esd-%c2%b115kv-requirements-in-servo-drive-pcba-with-tps-industrial-control-pcba-services\/","og_locale":"ar_AR","og_type":"article","og_title":"Wie lassen sich die EMV-Anforderungen f\u00fcr Sto\u00dfspannungen (Surge) von \u00b14 kV sowie f\u00fcr elektrostatische Entladungen (ESD) von \u00b115 kV bei Leiterplatten f\u00fcr Servoantriebe mithilfe der Dienstleistungen von TPS f\u00fcr industrielle Steuerungs-Leiterplatten erf\u00fcllen? - TPS","og_description":"industrial control pcba f\u00fcr industrielle Servosteuerungen m\u00fcssen Sto\u00dfspannungen von \u00b14 kV sowie ESD-Ereignisse von \u00b115 kV \u00fcberstehen. Die PCBA-Dienstleistungen von TPS umfassen Schutzma\u00dfnahmen, Layout-Design und Tests.","og_url":"https:\/\/tps-elektronik.com\/ar\/how-to-pass-emc-surge-%c2%b14kv-and-esd-%c2%b115kv-requirements-in-servo-drive-pcba-with-tps-industrial-control-pcba-services\/","og_site_name":"TPS","article_published_time":"2026-11-09T08:00:00+00:00","og_image":[{"width":1920,"height":1079,"url":"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/10\/Industrial-Control-PCBA-Servo-Drive-EMC-Test-1-1.jpg","type":"image\/jpeg"}],"author":"Tang Marcus","twitter_card":"summary_large_image","twitter_misc":{"\u0643\u064f\u062a\u0628 \u0628\u0648\u0627\u0633\u0637\u0629":"Tang Marcus","\u0648\u0642\u062a \u0627\u0644\u0642\u0631\u0627\u0621\u0629 \u0627\u0644\u0645\u064f\u0642\u062f\u0651\u0631":"9 \u062f\u0642\u0627\u0626\u0642"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/tps-elektronik.com\/ar\/how-to-pass-emc-surge-%c2%b14kv-and-esd-%c2%b115kv-requirements-in-servo-drive-pcba-with-tps-industrial-control-pcba-services\/#article","isPartOf":{"@id":"https:\/\/tps-elektronik.com\/ar\/how-to-pass-emc-surge-%c2%b14kv-and-esd-%c2%b115kv-requirements-in-servo-drive-pcba-with-tps-industrial-control-pcba-services\/"},"author":{"name":"Tang Marcus","@id":"https:\/\/tps-elektronik.com\/ar\/#\/schema\/person\/2c19fd053095d0c1ae253e8e62427b8c"},"headline":"Wie lassen sich die EMV-Anforderungen f\u00fcr Sto\u00dfspannungen (Surge) von \u00b14 kV sowie f\u00fcr elektrostatische Entladungen (ESD) von \u00b115 kV bei Leiterplatten f\u00fcr Servoantriebe mithilfe der Dienstleistungen von TPS f\u00fcr industrielle Steuerungs-Leiterplatten erf\u00fcllen?","datePublished":"2026-11-09T08:00:00+00:00","mainEntityOfPage":{"@id":"https:\/\/tps-elektronik.com\/ar\/how-to-pass-emc-surge-%c2%b14kv-and-esd-%c2%b115kv-requirements-in-servo-drive-pcba-with-tps-industrial-control-pcba-services\/"},"wordCount":1863,"image":{"@id":"https:\/\/tps-elektronik.com\/ar\/how-to-pass-emc-surge-%c2%b14kv-and-esd-%c2%b115kv-requirements-in-servo-drive-pcba-with-tps-industrial-control-pcba-services\/#primaryimage"},"thumbnailUrl":"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/10\/Industrial-Control-PCBA-Servo-Drive-EMC-Test-1-1.jpg","articleSection":["Blog-Inhalt"],"inLanguage":"ar"},{"@type":"WebPage","@id":"https:\/\/tps-elektronik.com\/ar\/how-to-pass-emc-surge-%c2%b14kv-and-esd-%c2%b115kv-requirements-in-servo-drive-pcba-with-tps-industrial-control-pcba-services\/","url":"https:\/\/tps-elektronik.com\/ar\/how-to-pass-emc-surge-%c2%b14kv-and-esd-%c2%b115kv-requirements-in-servo-drive-pcba-with-tps-industrial-control-pcba-services\/","name":"Wie lassen sich die EMV-Anforderungen f\u00fcr Sto\u00dfspannungen (Surge) von \u00b14 kV sowie f\u00fcr elektrostatische Entladungen (ESD) von \u00b115 kV bei Leiterplatten f\u00fcr Servoantriebe mithilfe der Dienstleistungen von TPS f\u00fcr industrielle Steuerungs-Leiterplatten erf\u00fcllen? - TPS","isPartOf":{"@id":"https:\/\/tps-elektronik.com\/ar\/#website"},"primaryImageOfPage":{"@id":"https:\/\/tps-elektronik.com\/ar\/how-to-pass-emc-surge-%c2%b14kv-and-esd-%c2%b115kv-requirements-in-servo-drive-pcba-with-tps-industrial-control-pcba-services\/#primaryimage"},"image":{"@id":"https:\/\/tps-elektronik.com\/ar\/how-to-pass-emc-surge-%c2%b14kv-and-esd-%c2%b115kv-requirements-in-servo-drive-pcba-with-tps-industrial-control-pcba-services\/#primaryimage"},"thumbnailUrl":"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/10\/Industrial-Control-PCBA-Servo-Drive-EMC-Test-1-1.jpg","datePublished":"2026-11-09T08:00:00+00:00","author":{"@id":"https:\/\/tps-elektronik.com\/ar\/#\/schema\/person\/2c19fd053095d0c1ae253e8e62427b8c"},"description":"industrial control pcba f\u00fcr industrielle Servosteuerungen m\u00fcssen Sto\u00dfspannungen von \u00b14 kV sowie ESD-Ereignisse von \u00b115 kV \u00fcberstehen. Die PCBA-Dienstleistungen von TPS umfassen Schutzma\u00dfnahmen, Layout-Design und Tests.","breadcrumb":{"@id":"https:\/\/tps-elektronik.com\/ar\/how-to-pass-emc-surge-%c2%b14kv-and-esd-%c2%b115kv-requirements-in-servo-drive-pcba-with-tps-industrial-control-pcba-services\/#breadcrumb"},"inLanguage":"ar","potentialAction":[{"@type":"ReadAction","target":["https:\/\/tps-elektronik.com\/ar\/how-to-pass-emc-surge-%c2%b14kv-and-esd-%c2%b115kv-requirements-in-servo-drive-pcba-with-tps-industrial-control-pcba-services\/"]}]},{"@type":"ImageObject","inLanguage":"ar","@id":"https:\/\/tps-elektronik.com\/ar\/how-to-pass-emc-surge-%c2%b14kv-and-esd-%c2%b115kv-requirements-in-servo-drive-pcba-with-tps-industrial-control-pcba-services\/#primaryimage","url":"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/10\/Industrial-Control-PCBA-Servo-Drive-EMC-Test-1-1.jpg","contentUrl":"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/10\/Industrial-Control-PCBA-Servo-Drive-EMC-Test-1-1.jpg","width":1920,"height":1079,"caption":"Industrial Control PCBA Servo Drive EMC Test"},{"@type":"BreadcrumbList","@id":"https:\/\/tps-elektronik.com\/ar\/how-to-pass-emc-surge-%c2%b14kv-and-esd-%c2%b115kv-requirements-in-servo-drive-pcba-with-tps-industrial-control-pcba-services\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Startseite","item":"https:\/\/tps-elektronik.com\/ar\/"},{"@type":"ListItem","position":2,"name":"Wie lassen sich die EMV-Anforderungen f\u00fcr Sto\u00dfspannungen (Surge) von \u00b14 kV sowie f\u00fcr elektrostatische Entladungen (ESD) von \u00b115 kV bei Leiterplatten f\u00fcr Servoantriebe mithilfe der Dienstleistungen von TPS f\u00fcr industrielle Steuerungs-Leiterplatten erf\u00fcllen?"}]},{"@type":"WebSite","@id":"https:\/\/tps-elektronik.com\/ar\/#website","url":"https:\/\/tps-elektronik.com\/ar\/","name":"TPS","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/tps-elektronik.com\/ar\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ar"},{"@type":"Person","@id":"https:\/\/tps-elektronik.com\/ar\/#\/schema\/person\/2c19fd053095d0c1ae253e8e62427b8c","name":"Tang Marcus"}]}},"_links":{"self":[{"href":"https:\/\/tps-elektronik.com\/ar\/wp-json\/wp\/v2\/posts\/19181","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/tps-elektronik.com\/ar\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/tps-elektronik.com\/ar\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/tps-elektronik.com\/ar\/wp-json\/wp\/v2\/users\/9"}],"replies":[{"embeddable":true,"href":"https:\/\/tps-elektronik.com\/ar\/wp-json\/wp\/v2\/comments?post=19181"}],"version-history":[{"count":3,"href":"https:\/\/tps-elektronik.com\/ar\/wp-json\/wp\/v2\/posts\/19181\/revisions"}],"predecessor-version":[{"id":19321,"href":"https:\/\/tps-elektronik.com\/ar\/wp-json\/wp\/v2\/posts\/19181\/revisions\/19321"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/tps-elektronik.com\/ar\/wp-json\/wp\/v2\/media\/19318"}],"wp:attachment":[{"href":"https:\/\/tps-elektronik.com\/ar\/wp-json\/wp\/v2\/media?parent=19181"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/tps-elektronik.com\/ar\/wp-json\/wp\/v2\/categories?post=19181"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/tps-elektronik.com\/ar\/wp-json\/wp\/v2\/tags?post=19181"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}