{"id":18942,"date":"2026-11-02T09:00:00","date_gmt":"2026-11-02T08:00:00","guid":{"rendered":"https:\/\/tps-elektronik.com\/?p=18942"},"modified":"2026-10-20T07:33:48","modified_gmt":"2026-10-20T05:33:48","slug":"how-to-achieve-low-leakage-inductance-in-dc-dc-converter-transformers-with-tps-custom-electromagnetic-coils-for-small-power-modules","status":"publish","type":"post","link":"https:\/\/tps-elektronik.com\/ar\/how-to-achieve-low-leakage-inductance-in-dc-dc-converter-transformers-with-tps-custom-electromagnetic-coils-for-small-power-modules\/","title":{"rendered":"Wie l\u00e4sst sich bei Transformatoren f\u00fcr DC-DC-Wandler \u2013 etwa f\u00fcr kompakte Leistungsmodule \u2013 eine geringe Streuinduktivit\u00e4t durch kundenspezifische elektromagnetische Spulen von TPS erzielen?"},"content":{"rendered":"<article class=\"blog-post\" lang=\"de\"><header>\n<p>Systemintegratoren, Schaltschrankbauer und Beschaffungsteams in der Leistungselektronik scheitern selten, weil ihnen ein Transformatordesign fehlt. Sie verlieren Zeit\u2014und Marge\u2014wenn die Streuinduktivit\u00e4t in einem kleinen DC-DC-Transformator Spannungsspitzen am Schaltknoten, Klingeln und gestrahlte St\u00f6raussendungen erzeugt, die erst bei Volllast oder w\u00e4hrend der EMV-Pr\u00fcfung sichtbar werden.<br \/>Die custom electromagnetic coils\u00a0von TPS Elektronik sind darauf ausgelegt, dieses Risiko zu reduzieren: verschachtelte Wicklungsarchitekturen, kontrollierte Zwischenwicklungsabst\u00e4nde und gemessene Streuinduktivit\u00e4t vom Prototyp bis zur Serienproduktion.<\/p>\n<p><a class=\"cta-primary\" href=\"https:\/\/tps-elektronik.com\/services\/ems\/wickelgueter\/\">Besprechen Sie Ihre Anforderungen an streuarme Transformatoren mit TPS \u2192<\/a><\/p>\n<\/header><nav class=\"toc\" aria-label=\"Inhaltsverzeichnis\">\n<h2 id=\"toc\">Inhaltsverzeichnis<\/h2>\n<ol>\n<li><a href=\"#was-ist-streuung\">Was Streuinduktivit\u00e4t in einem DC-DC-Transformator bedeutet<\/a>\n<ol>\n<li><a href=\"#streufluss-ursprung\">Woher der Streufluss kommt<\/a><\/li>\n<li><a href=\"#kleinmodul-empfindlichkeit\">Warum kleine Leistungsmodule empfindlicher sind<\/a><\/li>\n<\/ol>\n<\/li>\n<li><a href=\"#wicklungsarchitekturen\">Wicklungsarchitekturen zur Reduzierung der Streuinduktivit\u00e4t<\/a>\n<ol>\n<li><a href=\"#verschachtelung\">Verschachtelte und Sandwich-Wicklungen<\/a><\/li>\n<li><a href=\"#geometrie\">Kern-, Spulenk\u00f6rper- und Leitergeometrie<\/a><\/li>\n<li><a href=\"#kompromiss\">Der Kompromiss mit der Wicklungskapazit\u00e4t<\/a><\/li>\n<\/ol>\n<\/li>\n<li><a href=\"#tps-ansatz\">Wie custom electromagnetic coils von TPS niedrige Streuung in der Serie liefern<\/a>\n<ol>\n<li><a href=\"#design-review\">Wicklungsgerechte Designpr\u00fcfung<\/a><\/li>\n<li><a href=\"#messung\">Messung und Validierung<\/a><\/li>\n<li><a href=\"#serie\">Vom Prototyp zur Serie<\/a><\/li>\n<\/ol>\n<\/li>\n<li><a href=\"#rfq-checkliste\">RFQ-Checkliste f\u00fcr streuarme DC-DC-Transformatoren<\/a><\/li>\n<li><a href=\"#faq\">FAQ<\/a><\/li>\n<\/ol>\n<\/nav>\n<section id=\"was-ist-streuung\">\n<h2>1. Was Streuinduktivit\u00e4t in einem DC-DC-Transformator bedeutet<\/h2>\n<p>In einem idealen Transformator verkn\u00fcpft der gesamte vom Prim\u00e4rwicklung erzeugte magnetische Fluss die Sekund\u00e4rwicklung. In einem realen Transformator schlie\u00dft ein Teil des Flusses \u00fcber Luft, Spulenk\u00f6rper und Isolierung zwischen den Wicklungen, statt beide Wicklungen zu verketten. Die in diesem Streufeld gespeicherte Energie erscheint als Serieninduktivit\u00e4t im Prim\u00e4rkreis\u2014die <strong>Streuinduktivit\u00e4t<\/strong>.<\/p>\n<p>F\u00fcr einen DC-DC-Wandler ist die Streuinduktivit\u00e4t kein vernachl\u00e4ssigbarer Parasit. Sie bestimmt den Spannungs\u00fcberschwinger am Schaltknoten beim Abschalten, die Klingelfrequenz nach jedem Schalt\u00fcbergang, den Tastgradverlust in Durchfluss- und Sperrwandler-Topologien und den Hochfrequenzgehalt, der gefiltert werden muss, um CISPR-11- oder CISPR-32-Grenzwerte einzuhalten. In einem kleinen Leistungsmodul dominieren diese Effekte, weil der Wandler mit hoher Schaltfrequenz arbeitet und der Transformator nur einen kleinen Teil der Boardfl\u00e4che einnimmt.<\/p>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-18988\" src=\"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/10\/Low-Leakage-Transformer-Interleaved-Winding-Cross-Section-1.jpg\" alt=\"Low Leakage Transformer Interleaved Winding Cross Section\" width=\"1920\" height=\"1079\" \/><\/p>\n<h3 id=\"streufluss-ursprung\">1.1 Woher der Streufluss kommt<\/h3>\n<p>Streufluss entsteht \u00fcberall dort, wo die magnetomotorische Kraft der Wicklungen nicht vollst\u00e4ndig ausgeglichen ist. In kleinen Transformatoren dominieren drei Faktoren: der physische Abstand zwischen Prim\u00e4r- und Sekund\u00e4rwicklung, die Wicklungsfensterh\u00f6he, die nicht mit Kupfer gef\u00fcllt ist, und der Streufluss um den Kernspalt bei gespalteten Kernen.<\/p>\n<p>Der Abstandsterm ist am besten kontrollierbar. Jeder Millimeter Isolierung, Kriechstrecke und Spulenk\u00f6rperwand zwischen Prim\u00e4r und Sekund\u00e4r schafft einen Pfad f\u00fcr Streufluss. Sicherheitsnormen wie <a href=\"https:\/\/webstore.iec.ch\/en\/publication\/27753\" rel=\"nofollow noopener\" target=\"_blank\">IEC 61558-1<\/a> definieren Mindestisolationsabst\u00e4nde; die Designaufgabe besteht darin, diese Abst\u00e4nde einzuhalten und gleichzeitig den nicht sicherheitsbedingten Wicklungsabstand zu minimieren.<\/p>\n<h3 id=\"kleinmodul-empfindlichkeit\">1.2 Warum kleine Leistungsmodule empfindlicher sind<\/h3>\n<p>Die Streuinduktivit\u00e4t skaliert mit der Wicklungsgeometrie, aber sie skaliert nicht so schnell herunter wie die Magnetisierungsinduktivit\u00e4t des Transformators. In einem kleinen Modul ist die Windungszahl niedrig, das Wicklungsfenster klein, und die Isolierdicke wird ein gro\u00dfer Anteil des gesamten Wicklungsaufbaus. Das Ergebnis ist eine Streuinduktivit\u00e4t, die 5\u201315% der Magnetisierungsinduktivit\u00e4t erreichen kann\u2014genug, um bei wenigen Ampere Laststrom einen \u00dcberschwinger von mehreren zehn Volt am Schaltknoten zu erzeugen.<\/p>\n<p>Gleichzeitig ist die Schaltfrequenz in kleinen Modulen hoch, sodass die Stromkommutierungsrate di\/dt gro\u00df ist. Die durch die Streuinduktivit\u00e4t erzeugte Spannungsspitze ist V = L<sub>k<\/sub> \u00d7 di\/dt; eine Streuinduktivit\u00e4t, die bei 100 kHz akzeptabel w\u00e4re, wird bei 500 kHz zum Problem.<\/p>\n<p><a class=\"cta-primary\" href=\"https:\/\/tps-elektronik.com\/services\/ems\/wickelgueter\/\">TPS-Wickelgut-Services erkunden \u2192<\/a><\/p>\n<\/section>\n<section id=\"wicklungsarchitekturen\">\n<h2>2. Wicklungsarchitekturen zur Reduzierung der Streuinduktivit\u00e4t<\/h2>\n<p>Die Reduzierung der Streuinduktivit\u00e4t ist zuerst ein Wicklungsgeometrie-Problem und erst danach ein Bauteilauswahl-Problem. Das Ziel ist, die magnetische Kopplung zwischen Prim\u00e4r und Sekund\u00e4r zu maximieren und gleichzeitig die von der Sicherheitsnorm geforderten Isolationsabst\u00e4nde und die f\u00fcr die Serienfertigung erforderliche Herstellbarkeit einzuhalten.<\/p>\n<h3 id=\"verschachtelung\">2.1 Verschachtelte und Sandwich-Wicklungen<\/h3>\n<p>Die wirksamste Einzelma\u00dfnahme ist, die Prim\u00e4rwicklung in zwei H\u00e4lften zu teilen und die Sekund\u00e4rwicklung dazwischen zu platzieren\u2014das klassische <strong>P-S-P-Sandwich<\/strong>. Jede Prim\u00e4rh\u00e4lfte liegt n\u00e4her an der Sekund\u00e4rwicklung, der Streuflusspfad wird verk\u00fcrzt und die gespeicherte Streuenergie sinkt. In kleinen Transformatoren kann ein sauber ausgef\u00fchrtes Sandwich die Streuinduktivit\u00e4t um 40\u201370% gegen\u00fcber einer konventionellen Prim\u00e4r-dann-Sekund\u00e4r-Anordnung reduzieren.<\/p>\n<p>Weitere Verschachtelung, etwa P-S-P-S oder mehrere parallele Sekund\u00e4rlagen, reduziert die Streuinduktivit\u00e4t weiter, erh\u00f6ht aber die Wicklungskomplexit\u00e4t und die Zwischenwicklungskapazit\u00e4t. Das Optimum h\u00e4ngt von der Wandler-Topologie, der Schaltfrequenz und dem akzeptablen Gleichtakt-St\u00f6rniveau ab.<\/p>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-18983\" src=\"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/10\/Leakage-Inductance-Measurement-Short-Circuit-Test-Transformer-2-1.jpg\" alt=\"Leakage Inductance Measurement Short Circuit Test Transformer\" width=\"1920\" height=\"1079\" \/><\/p>\n<h3 id=\"geometrie\">2.2 Kern-, Spulenk\u00f6rper- und Leitergeometrie<\/h3>\n<p>Die Kernform bestimmt, wie viel Wicklungsfenster f\u00fcr Kupfer verf\u00fcgbar ist. Topfkerne, RM-Kerne, EP-Kerne und planare ER-Kerne konzentrieren die Wicklung um den Mittelschenkel und reduzieren die mittlere Windungsl\u00e4nge, was sowohl Kupferverluste als auch Streuinduktivit\u00e4t senkt. Planare Wicklungen auf einer Mehrlagenplatine bieten eine sehr enge Kopplung und eine reproduzierbare Geometrie; deshalb sind sie in kleinen Leistungsmodulen \u00fcber 200 kHz verbreitet.<\/p>\n<p>Auch der Leiter z\u00e4hlt. Folienwicklungen f\u00fcr hochstromf\u00fchrende Sekund\u00e4rwindungen maximieren die Kupferf\u00fcllung des Fensters und reduzieren den Abstand zwischen den Prim\u00e4r- und Sekund\u00e4rstromschichten. Litze reduziert Skin- und Proximity-Verluste, senkt aber nicht allein die Streuinduktivit\u00e4t\u2014sie muss mit einem verschachtelten Layout kombiniert werden.<\/p>\n<p>F\u00fcr Designs, in denen eine Ringkerngeometrie bevorzugt wird, liefert die verteilte Wicklung inh\u00e4rent niedrige Streuung, aber Wickelkosten und Reproduzierbarkeit m\u00fcssen gegen die Anwendung bewertet werden. Die <a href=\"https:\/\/tps-elektronik.com\/ar\/ems-wicklungsprodukte-ringkernspulen-dv-dt-drosseln-serienreife-transformatoren\/\">Ressource zu Ringkernspulen und serienreifen Transformatoren<\/a> von TPS behandelt diese Abw\u00e4gung ausf\u00fchrlicher.<\/p>\n<h3 id=\"kompromiss\">2.3 Der Kompromiss mit der Wicklungskapazit\u00e4t<\/h3>\n<p>Jede Reduzierung der Streuinduktivit\u00e4t durch engere Kopplung erh\u00f6ht die Zwischenwicklungskapazit\u00e4t. Diese Kapazit\u00e4t bildet einen Pfad f\u00fcr Gleichtaktstr\u00f6me von der Prim\u00e4r- zur Sekund\u00e4rseite und kann die leitungsgebundenen St\u00f6raussendungen bei der Schaltfrequenz und ihren Harmonischen erh\u00f6hen. Das Designziel ist deshalb nicht \u201eminimale Streuinduktivit\u00e4t\u201c, sondern ein ausgewogener Satz aus Streuinduktivit\u00e4t, Zwischenwicklungskapazit\u00e4t und Isolationsabstand, der die elektrischen und EMV-Anforderungen des Wandlers erf\u00fcllt.<\/p>\n<p>Deshalb behandelt TPS den Transformator als Teil des Wandlerdesigns und nicht als eigenst\u00e4ndiges Bauteil. Der <a href=\"https:\/\/tps-elektronik.com\/ar\/drahtisolierung-materialien-typen-anwendungen\/\">Leitfaden zu Drahtisolierungsmaterialien<\/a> dokumentiert die Isolierungsoptionen, die sowohl den Sicherheitsabstand als auch den Wicklungsaufbau beeinflussen.<\/p>\n<\/section>\n<section id=\"tps-ansatz\">\n<h2>3. Wie custom electromagnetic coils von TPS niedrige Streuung in der Serie liefern<\/h2>\n<p>TPS Elektronik fertigt <strong>custom electromagnetic coils<\/strong>\u00a0und Wickelg\u00fcter als Teil seines EMS-Portfolios, einschlie\u00dflich Hochfrequenztransformatoren, Ringkernspulen und DV\/DT-Drosseln. F\u00fcr kleine DC-DC-Leistungsmodule ist der Workflow in drei Stufen gegliedert: Designpr\u00fcfung, Messung und Serien\u00fcbertragung.<\/p>\n<h3 id=\"design-review\">3.1 Wicklungsgerechte Designpr\u00fcfung<\/h3>\n<p>Die Pr\u00fcfung beginnt mit den Wandleranforderungen: Eingangs- und Ausgangsspannung, Schaltfrequenz, Ziel-Streuinduktivit\u00e4t, Isolationsklasse und verf\u00fcgbare Grundfl\u00e4che. TPS-Ingenieure bewerten dann die Wicklungsanordnung, die Kern- und Spulenk\u00f6rperwahl, den Leitertyp und das Verschachtelungsschema gegen die Herstellbarkeitsgrenzen der Wickelmaschine.<\/p>\n<p>Das Ergebnis ist eine Wicklungsspezifikation, die Lagenreihenfolge, Windungszahl pro Lage, Isolierung zwischen den Lagen, Anschlussmethode und Ziel-Streuinduktivit\u00e4t mit Toleranzband definiert. F\u00fcr medizinische und Hochfrequenzanwendungen beschreibt die <a href=\"https:\/\/tps-elektronik.com\/ar\/ems-wickelwaren-medizinische-hochfrequenztransformatoren-spulenwicklungen\/\">Ressource zu medizinischen Hochfrequenztransformatoren und Spulenwicklungen<\/a> die zus\u00e4tzlichen Dokumentations- und Prozesskontrollanforderungen.<\/p>\n<h3 id=\"messung\">3.2 Messung und Validierung<\/h3>\n<p>Die Streuinduktivit\u00e4t wird gemessen, indem die Sekund\u00e4rwicklung kurzgeschlossen und ein LCR-Meter oder Impedanzanalysator an die Prim\u00e4rwicklung angeschlossen wird. Die Messung muss bei der Schaltfrequenz des Wandlers erfolgen, nicht bei 1 kHz, weil die Streuinduktivit\u00e4t aufgrund von Skin- und Proximity-Effekten in den Wicklungen frequenzabh\u00e4ngig ist. TPS misst bei der Anwendungsfrequenz und dokumentiert das Ergebnis im Wicklungsdatenblatt.<\/p>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-18978\" src=\"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/10\/Sandwich-Winding-vs-Conventional-Winding-Low-Leakage-3.jpg\" alt=\"Sandwich Winding vs Conventional Winding Low Leakage\" width=\"1920\" height=\"1079\" \/><\/p>\n<p>Der Validierungssatz umfasst au\u00dferdem \u00dcbersetzungsverh\u00e4ltnis, Magnetisierungsinduktivit\u00e4t, Zwischenwicklungskapazit\u00e4t, Hipot-Pr\u00fcfspannung und Isolationswiderstand. Bei Hochfrequenzdesigns wird der Wicklungsverlust mit einem Impedanzanalysator-Sweep bewertet, um zu best\u00e4tigen, dass der Wechselstromwiderstand im thermischen Budget bleibt.<\/p>\n<h3 id=\"serie\">3.3 Vom Prototyp zur Serie<\/h3>\n<p>Sobald die Prototypwicklung die elektrischen und thermischen Ziele erf\u00fcllt, \u00fcbertr\u00e4gt TPS das Design auf programmierbare Wickelmaschinen mit Zugkraftregelung, Windungsz\u00e4hlung und Lagenisolationsplatzierung. Die kritischen Parameter f\u00fcr die Reproduzierbarkeit sind Drahtzugkraft, Wickelgeschwindigkeit und die Position der Verschachtelungslagen\u2014alle werden durch das Maschinenprogramm gesteuert und durch die Erstmusterpr\u00fcfung verifiziert.<\/p>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-18973\" src=\"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/10\/Custom-Electromagnetic-Coils-Winding-Production-TPS-4-1.jpg\" alt=\"Custom Electromagnetic Coils Winding Production TPS\" width=\"1920\" height=\"1079\" \/><\/p>\n<p>Die Serienproduktion umfasst 100% Hipot- und \u00dcbersetzungsverh\u00e4ltnispr\u00fcfung, wobei die Streuinduktivit\u00e4t stichprobenartig oder bei kritischen Anwendungen an jedem St\u00fcck gemessen wird. Die <a href=\"https:\/\/tps-elektronik.com\/ar\/ems-wickelgueter-spulenwicklung\/\">Service-Seite zur Spulenwicklung<\/a> beschreibt den Produktionsumfang, und der <a href=\"https:\/\/tps-elektronik.com\/ar\/helmholtz-spule-magnetfeld-ratgeber\/\">Helmholtz-Spulen-Leitfaden<\/a> liefert Hintergrund zu den Magnetfeldprinzipien, die dem Wicklungsdesign zugrunde liegen.<\/p>\n<p><a class=\"cta-primary\" href=\"https:\/\/tps-elektronik.com\/services\/ems\/wickelgueter\/\">Angebot f\u00fcr streuarme Transformatoren anfordern \u2192<\/a><\/p>\n<\/section>\n<section id=\"rfq-checkliste\">\n<h2>4. RFQ-Checkliste f\u00fcr streuarme DC-DC-Transformatoren<\/h2>\n<p>Um Angebotserstellung und Bewertung zu beschleunigen, geben Sie bei der Anforderung eines <strong>streuarmen Transformators<\/strong> f\u00fcr ein kleines Leistungsmodul die folgenden Informationen an:<\/p>\n<ul>\n<li><strong>Elektrische Spezifikation<\/strong>: Eingangs- und Ausgangsspannung, Ausgangsleistung, Schaltfrequenz und Topologie (Sperrwandler, Durchflusswandler, Gegentakt, LLC)<\/li>\n<li><strong>Ziel-Streuinduktivit\u00e4t<\/strong>: Nennwert, Toleranz sowie Messfrequenz und Messbedingungen<\/li>\n<li><strong>Magnetisierungsinduktivit\u00e4t und \u00dcbersetzungsverh\u00e4ltnis<\/strong>: Mit Toleranzb\u00e4ndern<\/li>\n<li><strong>Isolationsanforderungen<\/strong>: Betriebsspannung, Isolationsklasse, Hipot-Spannung und anzuwendende Sicherheitsnorm (zum Beispiel IEC 61558-1)<\/li>\n<li><strong>Mechanische Randbedingungen<\/strong>: Maximale Grundfl\u00e4che, H\u00f6he, Montageart und Anschlusstyp<\/li>\n<li><strong>Thermische Anforderungen<\/strong>: Umgebungstemperatur, zul\u00e4ssige Erw\u00e4rmung und K\u00fchlmethode<\/li>\n<li><strong>Produktionsvolumen<\/strong>: Prototypenmenge, Jahresvolumen und erwartete Lebensdauer<\/li>\n<li><strong>Dokumentation<\/strong>: Wicklungsdatenblatt, Erstmusterpr\u00fcfbericht, Hipot-Pr\u00fcfprotokoll und Materialerkl\u00e4rungen<\/li>\n<\/ul>\n<p>Die Angabe dieser Details reduziert Kl\u00e4rungszyklen. Das Engineering-Team von TPS kann die Auswahl der Wicklungsarchitektur und die Definition der Ziel-Streuinduktivit\u00e4t als Teil des RFQ-Prozesses unterst\u00fctzen.<\/p>\n<\/section>\n<section id=\"faq\">\n<h2>5. FAQ<\/h2>\n<div>\n<h3>Welcher Streuinduktivit\u00e4tswert ist f\u00fcr einen kleinen DC-DC-Transformator typisch?<\/h3>\n<div>\n<div>Der akzeptable Wert h\u00e4ngt von Topologie, Schaltfrequenz und Spannungsfestigkeit des Schalters ab. Als Arbeitsregel wird die Streuinduktivit\u00e4t f\u00fcr Sperr- und Durchflusswandler oft auf 1\u20135% der Magnetisierungsinduktivit\u00e4t ausgelegt, bei hochfrequenten Resonanztopologien niedriger. Die entscheidende Pr\u00fcfung ist der Spannungs\u00fcberschwinger am Schaltknoten bei maximalem Laststrom.<\/div>\n<\/div>\n<h3>Reduziert eine verschachtelte Wicklung immer die Streuinduktivit\u00e4t?<\/h3>\n<div>\n<div>Verschachtelung reduziert die Streuinduktivit\u00e4t, indem sie den Abstand zwischen Prim\u00e4r- und Sekund\u00e4rstromschichten verk\u00fcrzt, erh\u00f6ht aber auch die Zwischenwicklungskapazit\u00e4t. In manchen Wandlern erh\u00f6ht die zus\u00e4tzliche Kapazit\u00e4t die Gleichtakt-Emissionen st\u00e4rker, als die reduzierte Streuinduktivit\u00e4t hilft. Die Wicklungsanordnung muss deshalb f\u00fcr den gesamten Wandler optimiert werden, nicht nur f\u00fcr die Streuinduktivit\u00e4t.<\/div>\n<\/div>\n<h3>Bei welcher Frequenz sollte die Streuinduktivit\u00e4t gemessen werden?<\/h3>\n<div>\n<div>Die Streuinduktivit\u00e4t sollte bei oder nahe der Schaltfrequenz des Wandlers gemessen werden, weil Skin- und Proximity-Effekte die effektive Induktivit\u00e4t bei hoher Frequenz ver\u00e4ndern. Eine Messung bei 1 kHz kann deutlich vom Wert abweichen, den der Wandler bei 300\u2013500 kHz sieht. TPS dokumentiert die Messfrequenz im Wicklungsdatenblatt.<\/div>\n<\/div>\n<h3>Kann TPS streuarme Transformatoren in Serienst\u00fcckzahlen fertigen?<\/h3>\n<div>\n<div>Ja. TPS \u00fcbertr\u00e4gt validierte Wicklungsdesigns auf programmierbare Wickelmaschinen mit Zugkraftregelung und Windungsz\u00e4hlung und f\u00fchrt in der Serienproduktion 100% Hipot- und \u00dcbersetzungsverh\u00e4ltnispr\u00fcfungen durch. Die Streuinduktivit\u00e4t wird stichprobenartig oder bei kritischen Anwendungen an jedem St\u00fcck gemessen. Details zum Umfang finden Sie auf der <a href=\"https:\/\/tps-elektronik.com\/services\/ems\/wickelgueter\/\">Service-Seite f\u00fcr Wickelg\u00fcter<\/a>.<\/div>\n<\/div>\n<h3>Welche Sicherheitsnorm gilt f\u00fcr die Transformatorisolierung?<\/h3>\n<div>\n<div>F\u00fcr kleine Leistungstransformatoren definiert IEC 61558-1 (und der relevante Teil 2 f\u00fcr die Anwendung) die Anforderungen an Isolierung, Kriechstrecken und Luftabst\u00e4nde. Das Transformatordesign muss diese Abst\u00e4nde einhalten und gleichzeitig den nicht sicherheitsbedingten Wicklungsabstand minimieren\u2014das ist der zentrale Kompromiss im streuarmen Wicklungsdesign.<\/div>\n<\/div>\n<\/div>\n<\/section>\n<footer style=\"background: #2d5797; padding: 30px; border-radius: 14px; margin-top: 40px;\">\n<p style=\"color: #ffffff; font-size: 16px; line-height: 1.6; margin: 0;\"><strong>Bereit, die Streuinduktivit\u00e4t in Ihrem DC-DC-Leistungsmodul zu reduzieren?<\/strong><br \/>Kontaktieren Sie TPS Elektronik f\u00fcr custom electromagnetic coils, verschachteltes Wicklungsdesign, Streuinduktivit\u00e4tsmessung und Serienfertigung kleiner Hochfrequenztransformatoren.<br \/><a style=\"color: #ffffff; font-weight: 600; text-decoration: underline;\" href=\"https:\/\/tps-elektronik.com\/services\/ems\/wickelgueter\/\">Ihre Wicklungsberatung anfragen \u2192<\/a><\/p>\n<\/footer><\/article>\n\n<style id=\"wpforms-css-vars-4336-block-68910790-c5c8-41aa-986b-446311b7195b\">\n\t\t\t\t#wpforms-4336.wpforms-block-68910790-c5c8-41aa-986b-446311b7195b {\n\t\t\t\t--wpforms-field-size-input-height: 43px;\n--wpforms-field-size-input-spacing: 15px;\n--wpforms-field-size-font-size: 16px;\n--wpforms-field-size-line-height: 19px;\n--wpforms-field-size-padding-h: 14px;\n--wpforms-field-size-checkbox-size: 16px;\n--wpforms-field-size-sublabel-spacing: 5px;\n--wpforms-field-size-icon-size: 1;\n--wpforms-label-size-font-size: 16px;\n--wpforms-label-size-line-height: 19px;\n--wpforms-label-size-sublabel-font-size: 14px;\n--wpforms-label-size-sublabel-line-height: 17px;\n--wpforms-button-size-font-size: 17px;\n--wpforms-button-size-height: 41px;\n--wpforms-button-size-padding-h: 15px;\n--wpforms-button-size-margin-top: 10px;\n\t\t\t}\n\t\t\t<\/style><div class=\"wpforms-container wpforms-container-full wpforms-block wpforms-block-68910790-c5c8-41aa-986b-446311b7195b wpforms-render-modern\" id=\"wpforms-4336\"><form id=\"wpforms-form-4336\" class=\"wpforms-validate wpforms-form wpforms-ajax-form\" data-formid=\"4336\" method=\"post\" enctype=\"multipart\/form-data\" action=\"\/ar\/wp-json\/wp\/v2\/posts\/18942\" data-token=\"aab983725f237df810ab3a9a7a040401\" data-token-time=\"1793925525\"><noscript class=\"wpforms-error-noscript\">Please enable JavaScript in your browser to complete this form.<\/noscript><div id=\"wpforms-error-noscript\" style=\"display: none;\">Please enable JavaScript in your browser to complete this form.<\/div><div class=\"wpforms-field-container\"><div id=\"wpforms-4336-field_1-container\" class=\"wpforms-field wpforms-field-name wpforms-one-half wpforms-first\" data-field-id=\"1\"><label class=\"wpforms-field-label\" for=\"wpforms-4336-field_1\">Name <span class=\"wpforms-required-label\" aria-hidden=\"true\">*<\/span><\/label><input type=\"text\" id=\"wpforms-4336-field_1\" class=\"wpforms-field-large wpforms-field-required\" name=\"wpforms[fields][1]\" aria-errormessage=\"wpforms-4336-field_1-error\" required><\/div><div id=\"wpforms-4336-field_2-container\" class=\"wpforms-field wpforms-field-email\" data-field-id=\"2\"><label class=\"wpforms-field-label\" for=\"wpforms-4336-field_2\">E-Mail <span class=\"wpforms-required-label\" aria-hidden=\"true\">*<\/span><\/label><input type=\"email\" id=\"wpforms-4336-field_2\" class=\"wpforms-field-large wpforms-field-required\" name=\"wpforms[fields][2]\" spellcheck=\"false\" aria-errormessage=\"wpforms-4336-field_2-error\" required><\/div>\t\t<div id=\"wpforms-4336-field_5-container\"\n\t\t\tclass=\"wpforms-field wpforms-field-text\"\n\t\t\tdata-field-type=\"text\"\n\t\t\tdata-field-id=\"5\"\n\t\t\t>\n\t\t\t<label class=\"wpforms-field-label\" for=\"wpforms-4336-field_5\" >Kurzbeschreibung Name E-Mail<\/label>\n\t\t\t<input type=\"text\" id=\"wpforms-4336-field_5\" class=\"wpforms-field-medium\" name=\"wpforms[fields][5]\" >\n\t\t<\/div>\n\t\t<div id=\"wpforms-4336-field_4-container\" class=\"wpforms-field wpforms-field-text\" data-field-id=\"4\"><label class=\"wpforms-field-label\" for=\"wpforms-4336-field_4\"> Firma <span class=\"wpforms-required-label\" aria-hidden=\"true\">*<\/span><\/label><input type=\"text\" id=\"wpforms-4336-field_4\" class=\"wpforms-field-large wpforms-field-required\" name=\"wpforms[fields][4]\" aria-errormessage=\"wpforms-4336-field_4-error\" required><\/div><div id=\"wpforms-4336-field_3-container\" class=\"wpforms-field wpforms-field-textarea\" data-field-id=\"3\"><label class=\"wpforms-field-label\" for=\"wpforms-4336-field_3\">Kurzbeschreibung<\/label><textarea id=\"wpforms-4336-field_3\" class=\"wpforms-field-medium\" name=\"wpforms[fields][3]\" aria-errormessage=\"wpforms-4336-field_3-error\" ><\/textarea><\/div><div id=\"wpforms-4336-field_6-container\" class=\"wpforms-field wpforms-field-checkbox\" data-field-id=\"6\"><fieldset><legend class=\"wpforms-field-label wpforms-label-hide\" aria-hidden=\"false\">Checkboxes <span class=\"wpforms-required-label\" aria-hidden=\"true\">*<\/span><\/legend><ul id=\"wpforms-4336-field_6\" class=\"wpforms-field-required\"><li class=\"choice-1 depth-1\"><input type=\"checkbox\" id=\"wpforms-4336-field_6_1\" name=\"wpforms[fields][6][]\" value=\"Ich stimme der Verarbeitung meiner Angaben zur Angebotserstellung zu.\" aria-errormessage=\"wpforms-4336-field_6_1-error\" aria-describedby=\"wpforms-4336-field_6-description\" required ><label class=\"wpforms-field-label-inline\" for=\"wpforms-4336-field_6_1\">Ich stimme der Verarbeitung meiner Angaben zur Angebotserstellung zu.<\/label><\/li><\/ul><div id=\"wpforms-4336-field_6-description\" class=\"wpforms-field-description\">Hinweise siehe Datenschutz.<\/div><\/fieldset><\/div><script>\n\t\t\t\t( function() {\n\t\t\t\t\tconst style = document.createElement( 'style' );\n\t\t\t\t\tstyle.appendChild( document.createTextNode( '#wpforms-4336-field_5-container { position: absolute !important; overflow: hidden !important; display: inline !important; height: 1px !important; width: 1px !important; z-index: -1000 !important; padding: 0 !important; } #wpforms-4336-field_5-container input { visibility: hidden; } #wpforms-conversational-form-page #wpforms-4336-field_5-container label { counter-increment: none; }' ) );\n\t\t\t\t\tdocument.head.appendChild( style );\n\t\t\t\t\tdocument.currentScript?.remove();\n\t\t\t\t} )();\n\t\t\t<\/script><\/div><!-- .wpforms-field-container --><div class=\"wpforms-recaptcha-container wpforms-is-turnstile\" ><div class=\"wpforms-turnstile\" data-sitekey=\"0x4AAAAAAFUTE-Rr1O4nxKnU\" data-action=\"FormID-4336\"><\/div><input type=\"text\" name=\"g-recaptcha-hidden\" class=\"wpforms-recaptcha-hidden\" style=\"position:absolute!important;clip:rect(0,0,0,0)!important;height:1px!important;width:1px!important;border:0!important;overflow:hidden!important;padding:0!important;margin:0!important;\" data-rule-turnstile=\"1\"><\/div><div class=\"wpforms-submit-container\" ><input type=\"hidden\" name=\"wpforms[id]\" value=\"4336\"><input type=\"hidden\" name=\"wpforms[time_token]\" value=\"1793925525.908e5b70bedd138ead04b68af549991f2f7f2f8fa956c8e49a3048db918edd13\"><input type=\"hidden\" name=\"page_title\" value=\"\"><input type=\"hidden\" name=\"page_url\" value=\"https:\/\/tps-elektronik.com\/ar\/wp-json\/wp\/v2\/posts\/18942\"><input type=\"hidden\" name=\"url_referer\" value=\"\"><button type=\"submit\" name=\"wpforms[submit]\" id=\"wpforms-submit-4336\" class=\"wpforms-submit\" data-alt-text=\"Senden...\" data-submit-text=\"Anfrage senden\" aria-live=\"assertive\" value=\"wpforms-submit\">Anfrage senden<\/button><img decoding=\"async\" src=\"https:\/\/tps-elektronik.com\/wp-content\/plugins\/wpforms-lite\/assets\/images\/submit-spin.svg\" class=\"wpforms-submit-spinner\" style=\"display: none;\" width=\"26\" height=\"26\" alt=\"Loading\"><\/div><\/form><\/div>  <!-- .wpforms-container -->","protected":false},"excerpt":{"rendered":"<p>Systemintegratoren, Schaltschrankbauer und Beschaffungsteams in der Leistungselektronik scheitern selten, weil ihnen ein Transformatordesign fehlt. Sie verlieren Zeit\u2014und Marge\u2014wenn die Streuinduktivit\u00e4t in einem kleinen DC-DC-Transformator Spannungsspitzen am Schaltknoten, Klingeln und gestrahlte St\u00f6raussendungen erzeugt, die erst bei Volllast oder w\u00e4hrend der EMV-Pr\u00fcfung sichtbar werden.Die custom electromagnetic coils\u00a0von TPS Elektronik sind darauf ausgelegt, dieses Risiko zu reduzieren: verschachtelte\u2026 <a href=\"https:\/\/tps-elektronik.com\/ar\/how-to-achieve-low-leakage-inductance-in-dc-dc-converter-transformers-with-tps-custom-electromagnetic-coils-for-small-power-modules\/\">Read More &raquo;<\/a><\/p>\n","protected":false},"author":9,"featured_media":18988,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[59],"tags":[],"class_list":["post-18942","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog-inhalt"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Wie l\u00e4sst sich bei Transformatoren f\u00fcr DC-DC-Wandler \u2013 etwa f\u00fcr kompakte Leistungsmodule \u2013 eine geringe Streuinduktivit\u00e4t durch kundenspezifische elektromagnetische Spulen von TPS erzielen? - TPS<\/title>\n<meta name=\"description\" content=\"Transformatorwicklungen mit geringer Streuinduktivit\u00e4t f\u00fcr DC-DC-Leistungsmodule reduzieren Spannungsspitzen und elektromagnetische St\u00f6rungen (EMI). TPS custom electromagnetic coils \u2013 vom Prototyp bis zur Serienfertigung.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/tps-elektronik.com\/ar\/how-to-achieve-low-leakage-inductance-in-dc-dc-converter-transformers-with-tps-custom-electromagnetic-coils-for-small-power-modules\/\" \/>\n<meta property=\"og:locale\" content=\"ar_AR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Wie l\u00e4sst sich bei Transformatoren f\u00fcr DC-DC-Wandler \u2013 etwa f\u00fcr kompakte Leistungsmodule \u2013 eine geringe Streuinduktivit\u00e4t durch kundenspezifische elektromagnetische Spulen von TPS erzielen? - TPS\" \/>\n<meta property=\"og:description\" content=\"Transformatorwicklungen mit geringer Streuinduktivit\u00e4t f\u00fcr DC-DC-Leistungsmodule reduzieren Spannungsspitzen und elektromagnetische St\u00f6rungen (EMI). TPS custom electromagnetic coils \u2013 vom Prototyp bis zur Serienfertigung.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/tps-elektronik.com\/ar\/how-to-achieve-low-leakage-inductance-in-dc-dc-converter-transformers-with-tps-custom-electromagnetic-coils-for-small-power-modules\/\" \/>\n<meta property=\"og:site_name\" content=\"TPS\" \/>\n<meta property=\"article:published_time\" content=\"2026-11-02T08:00:00+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/10\/Low-Leakage-Transformer-Interleaved-Winding-Cross-Section-1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1920\" \/>\n\t<meta property=\"og:image:height\" content=\"1079\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Tang Marcus\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u0643\u064f\u062a\u0628 \u0628\u0648\u0627\u0633\u0637\u0629\" \/>\n\t<meta name=\"twitter:data1\" content=\"Tang Marcus\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u0648\u0642\u062a \u0627\u0644\u0642\u0631\u0627\u0621\u0629 \u0627\u0644\u0645\u064f\u0642\u062f\u0651\u0631\" \/>\n\t<meta name=\"twitter:data2\" content=\"8 \u062f\u0642\u0627\u0626\u0642\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/ar\\\/how-to-achieve-low-leakage-inductance-in-dc-dc-converter-transformers-with-tps-custom-electromagnetic-coils-for-small-power-modules\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/ar\\\/how-to-achieve-low-leakage-inductance-in-dc-dc-converter-transformers-with-tps-custom-electromagnetic-coils-for-small-power-modules\\\/\"},\"author\":{\"name\":\"Tang Marcus\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/ar\\\/#\\\/schema\\\/person\\\/2c19fd053095d0c1ae253e8e62427b8c\"},\"headline\":\"Wie l\u00e4sst sich bei Transformatoren f\u00fcr DC-DC-Wandler \u2013 etwa f\u00fcr kompakte Leistungsmodule \u2013 eine geringe Streuinduktivit\u00e4t durch kundenspezifische elektromagnetische Spulen von TPS erzielen?\",\"datePublished\":\"2026-11-02T08:00:00+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/ar\\\/how-to-achieve-low-leakage-inductance-in-dc-dc-converter-transformers-with-tps-custom-electromagnetic-coils-for-small-power-modules\\\/\"},\"wordCount\":1745,\"image\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/ar\\\/how-to-achieve-low-leakage-inductance-in-dc-dc-converter-transformers-with-tps-custom-electromagnetic-coils-for-small-power-modules\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/tps-elektronik.com\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/Low-Leakage-Transformer-Interleaved-Winding-Cross-Section-1.jpg\",\"articleSection\":[\"Blog-Inhalt\"],\"inLanguage\":\"ar\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/ar\\\/how-to-achieve-low-leakage-inductance-in-dc-dc-converter-transformers-with-tps-custom-electromagnetic-coils-for-small-power-modules\\\/\",\"url\":\"https:\\\/\\\/tps-elektronik.com\\\/ar\\\/how-to-achieve-low-leakage-inductance-in-dc-dc-converter-transformers-with-tps-custom-electromagnetic-coils-for-small-power-modules\\\/\",\"name\":\"Wie l\u00e4sst sich bei Transformatoren f\u00fcr DC-DC-Wandler \u2013 etwa f\u00fcr kompakte Leistungsmodule \u2013 eine geringe Streuinduktivit\u00e4t durch kundenspezifische elektromagnetische Spulen von TPS erzielen? - TPS\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/ar\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/ar\\\/how-to-achieve-low-leakage-inductance-in-dc-dc-converter-transformers-with-tps-custom-electromagnetic-coils-for-small-power-modules\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/ar\\\/how-to-achieve-low-leakage-inductance-in-dc-dc-converter-transformers-with-tps-custom-electromagnetic-coils-for-small-power-modules\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/tps-elektronik.com\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/Low-Leakage-Transformer-Interleaved-Winding-Cross-Section-1.jpg\",\"datePublished\":\"2026-11-02T08:00:00+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/ar\\\/#\\\/schema\\\/person\\\/2c19fd053095d0c1ae253e8e62427b8c\"},\"description\":\"Transformatorwicklungen mit geringer Streuinduktivit\u00e4t f\u00fcr DC-DC-Leistungsmodule reduzieren Spannungsspitzen und elektromagnetische St\u00f6rungen (EMI). TPS custom electromagnetic coils \u2013 vom Prototyp bis zur Serienfertigung.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/ar\\\/how-to-achieve-low-leakage-inductance-in-dc-dc-converter-transformers-with-tps-custom-electromagnetic-coils-for-small-power-modules\\\/#breadcrumb\"},\"inLanguage\":\"ar\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/tps-elektronik.com\\\/ar\\\/how-to-achieve-low-leakage-inductance-in-dc-dc-converter-transformers-with-tps-custom-electromagnetic-coils-for-small-power-modules\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ar\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/ar\\\/how-to-achieve-low-leakage-inductance-in-dc-dc-converter-transformers-with-tps-custom-electromagnetic-coils-for-small-power-modules\\\/#primaryimage\",\"url\":\"https:\\\/\\\/tps-elektronik.com\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/Low-Leakage-Transformer-Interleaved-Winding-Cross-Section-1.jpg\",\"contentUrl\":\"https:\\\/\\\/tps-elektronik.com\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/Low-Leakage-Transformer-Interleaved-Winding-Cross-Section-1.jpg\",\"width\":1920,\"height\":1079,\"caption\":\"Low Leakage Transformer Interleaved Winding Cross Section\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/ar\\\/how-to-achieve-low-leakage-inductance-in-dc-dc-converter-transformers-with-tps-custom-electromagnetic-coils-for-small-power-modules\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Startseite\",\"item\":\"https:\\\/\\\/tps-elektronik.com\\\/ar\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Wie l\u00e4sst sich bei Transformatoren f\u00fcr DC-DC-Wandler \u2013 etwa f\u00fcr kompakte Leistungsmodule \u2013 eine geringe Streuinduktivit\u00e4t durch kundenspezifische elektromagnetische Spulen von TPS erzielen?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/ar\\\/#website\",\"url\":\"https:\\\/\\\/tps-elektronik.com\\\/ar\\\/\",\"name\":\"TPS\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/tps-elektronik.com\\\/ar\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ar\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/tps-elektronik.com\\\/ar\\\/#\\\/schema\\\/person\\\/2c19fd053095d0c1ae253e8e62427b8c\",\"name\":\"Tang Marcus\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Wie l\u00e4sst sich bei Transformatoren f\u00fcr DC-DC-Wandler \u2013 etwa f\u00fcr kompakte Leistungsmodule \u2013 eine geringe Streuinduktivit\u00e4t durch kundenspezifische elektromagnetische Spulen von TPS erzielen? - TPS","description":"Transformatorwicklungen mit geringer Streuinduktivit\u00e4t f\u00fcr DC-DC-Leistungsmodule reduzieren Spannungsspitzen und elektromagnetische St\u00f6rungen (EMI). TPS custom electromagnetic coils \u2013 vom Prototyp bis zur Serienfertigung.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/tps-elektronik.com\/ar\/how-to-achieve-low-leakage-inductance-in-dc-dc-converter-transformers-with-tps-custom-electromagnetic-coils-for-small-power-modules\/","og_locale":"ar_AR","og_type":"article","og_title":"Wie l\u00e4sst sich bei Transformatoren f\u00fcr DC-DC-Wandler \u2013 etwa f\u00fcr kompakte Leistungsmodule \u2013 eine geringe Streuinduktivit\u00e4t durch kundenspezifische elektromagnetische Spulen von TPS erzielen? - TPS","og_description":"Transformatorwicklungen mit geringer Streuinduktivit\u00e4t f\u00fcr DC-DC-Leistungsmodule reduzieren Spannungsspitzen und elektromagnetische St\u00f6rungen (EMI). TPS custom electromagnetic coils \u2013 vom Prototyp bis zur Serienfertigung.","og_url":"https:\/\/tps-elektronik.com\/ar\/how-to-achieve-low-leakage-inductance-in-dc-dc-converter-transformers-with-tps-custom-electromagnetic-coils-for-small-power-modules\/","og_site_name":"TPS","article_published_time":"2026-11-02T08:00:00+00:00","og_image":[{"width":1920,"height":1079,"url":"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/10\/Low-Leakage-Transformer-Interleaved-Winding-Cross-Section-1.jpg","type":"image\/jpeg"}],"author":"Tang Marcus","twitter_card":"summary_large_image","twitter_misc":{"\u0643\u064f\u062a\u0628 \u0628\u0648\u0627\u0633\u0637\u0629":"Tang Marcus","\u0648\u0642\u062a \u0627\u0644\u0642\u0631\u0627\u0621\u0629 \u0627\u0644\u0645\u064f\u0642\u062f\u0651\u0631":"8 \u062f\u0642\u0627\u0626\u0642"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/tps-elektronik.com\/ar\/how-to-achieve-low-leakage-inductance-in-dc-dc-converter-transformers-with-tps-custom-electromagnetic-coils-for-small-power-modules\/#article","isPartOf":{"@id":"https:\/\/tps-elektronik.com\/ar\/how-to-achieve-low-leakage-inductance-in-dc-dc-converter-transformers-with-tps-custom-electromagnetic-coils-for-small-power-modules\/"},"author":{"name":"Tang Marcus","@id":"https:\/\/tps-elektronik.com\/ar\/#\/schema\/person\/2c19fd053095d0c1ae253e8e62427b8c"},"headline":"Wie l\u00e4sst sich bei Transformatoren f\u00fcr DC-DC-Wandler \u2013 etwa f\u00fcr kompakte Leistungsmodule \u2013 eine geringe Streuinduktivit\u00e4t durch kundenspezifische elektromagnetische Spulen von TPS erzielen?","datePublished":"2026-11-02T08:00:00+00:00","mainEntityOfPage":{"@id":"https:\/\/tps-elektronik.com\/ar\/how-to-achieve-low-leakage-inductance-in-dc-dc-converter-transformers-with-tps-custom-electromagnetic-coils-for-small-power-modules\/"},"wordCount":1745,"image":{"@id":"https:\/\/tps-elektronik.com\/ar\/how-to-achieve-low-leakage-inductance-in-dc-dc-converter-transformers-with-tps-custom-electromagnetic-coils-for-small-power-modules\/#primaryimage"},"thumbnailUrl":"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/10\/Low-Leakage-Transformer-Interleaved-Winding-Cross-Section-1.jpg","articleSection":["Blog-Inhalt"],"inLanguage":"ar"},{"@type":"WebPage","@id":"https:\/\/tps-elektronik.com\/ar\/how-to-achieve-low-leakage-inductance-in-dc-dc-converter-transformers-with-tps-custom-electromagnetic-coils-for-small-power-modules\/","url":"https:\/\/tps-elektronik.com\/ar\/how-to-achieve-low-leakage-inductance-in-dc-dc-converter-transformers-with-tps-custom-electromagnetic-coils-for-small-power-modules\/","name":"Wie l\u00e4sst sich bei Transformatoren f\u00fcr DC-DC-Wandler \u2013 etwa f\u00fcr kompakte Leistungsmodule \u2013 eine geringe Streuinduktivit\u00e4t durch kundenspezifische elektromagnetische Spulen von TPS erzielen? - TPS","isPartOf":{"@id":"https:\/\/tps-elektronik.com\/ar\/#website"},"primaryImageOfPage":{"@id":"https:\/\/tps-elektronik.com\/ar\/how-to-achieve-low-leakage-inductance-in-dc-dc-converter-transformers-with-tps-custom-electromagnetic-coils-for-small-power-modules\/#primaryimage"},"image":{"@id":"https:\/\/tps-elektronik.com\/ar\/how-to-achieve-low-leakage-inductance-in-dc-dc-converter-transformers-with-tps-custom-electromagnetic-coils-for-small-power-modules\/#primaryimage"},"thumbnailUrl":"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/10\/Low-Leakage-Transformer-Interleaved-Winding-Cross-Section-1.jpg","datePublished":"2026-11-02T08:00:00+00:00","author":{"@id":"https:\/\/tps-elektronik.com\/ar\/#\/schema\/person\/2c19fd053095d0c1ae253e8e62427b8c"},"description":"Transformatorwicklungen mit geringer Streuinduktivit\u00e4t f\u00fcr DC-DC-Leistungsmodule reduzieren Spannungsspitzen und elektromagnetische St\u00f6rungen (EMI). TPS custom electromagnetic coils \u2013 vom Prototyp bis zur Serienfertigung.","breadcrumb":{"@id":"https:\/\/tps-elektronik.com\/ar\/how-to-achieve-low-leakage-inductance-in-dc-dc-converter-transformers-with-tps-custom-electromagnetic-coils-for-small-power-modules\/#breadcrumb"},"inLanguage":"ar","potentialAction":[{"@type":"ReadAction","target":["https:\/\/tps-elektronik.com\/ar\/how-to-achieve-low-leakage-inductance-in-dc-dc-converter-transformers-with-tps-custom-electromagnetic-coils-for-small-power-modules\/"]}]},{"@type":"ImageObject","inLanguage":"ar","@id":"https:\/\/tps-elektronik.com\/ar\/how-to-achieve-low-leakage-inductance-in-dc-dc-converter-transformers-with-tps-custom-electromagnetic-coils-for-small-power-modules\/#primaryimage","url":"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/10\/Low-Leakage-Transformer-Interleaved-Winding-Cross-Section-1.jpg","contentUrl":"https:\/\/tps-elektronik.com\/wp-content\/uploads\/2026\/10\/Low-Leakage-Transformer-Interleaved-Winding-Cross-Section-1.jpg","width":1920,"height":1079,"caption":"Low Leakage Transformer Interleaved Winding Cross Section"},{"@type":"BreadcrumbList","@id":"https:\/\/tps-elektronik.com\/ar\/how-to-achieve-low-leakage-inductance-in-dc-dc-converter-transformers-with-tps-custom-electromagnetic-coils-for-small-power-modules\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Startseite","item":"https:\/\/tps-elektronik.com\/ar\/"},{"@type":"ListItem","position":2,"name":"Wie l\u00e4sst sich bei Transformatoren f\u00fcr DC-DC-Wandler \u2013 etwa f\u00fcr kompakte Leistungsmodule \u2013 eine geringe Streuinduktivit\u00e4t durch kundenspezifische elektromagnetische Spulen von TPS erzielen?"}]},{"@type":"WebSite","@id":"https:\/\/tps-elektronik.com\/ar\/#website","url":"https:\/\/tps-elektronik.com\/ar\/","name":"TPS","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/tps-elektronik.com\/ar\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ar"},{"@type":"Person","@id":"https:\/\/tps-elektronik.com\/ar\/#\/schema\/person\/2c19fd053095d0c1ae253e8e62427b8c","name":"Tang Marcus"}]}},"_links":{"self":[{"href":"https:\/\/tps-elektronik.com\/ar\/wp-json\/wp\/v2\/posts\/18942","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/tps-elektronik.com\/ar\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/tps-elektronik.com\/ar\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/tps-elektronik.com\/ar\/wp-json\/wp\/v2\/users\/9"}],"replies":[{"embeddable":true,"href":"https:\/\/tps-elektronik.com\/ar\/wp-json\/wp\/v2\/comments?post=18942"}],"version-history":[{"count":3,"href":"https:\/\/tps-elektronik.com\/ar\/wp-json\/wp\/v2\/posts\/18942\/revisions"}],"predecessor-version":[{"id":18992,"href":"https:\/\/tps-elektronik.com\/ar\/wp-json\/wp\/v2\/posts\/18942\/revisions\/18992"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/tps-elektronik.com\/ar\/wp-json\/wp\/v2\/media\/18988"}],"wp:attachment":[{"href":"https:\/\/tps-elektronik.com\/ar\/wp-json\/wp\/v2\/media?parent=18942"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/tps-elektronik.com\/ar\/wp-json\/wp\/v2\/categories?post=18942"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/tps-elektronik.com\/ar\/wp-json\/wp\/v2\/tags?post=18942"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}